Tender For Repair And Maint Of Distribution Transformer Switchgear, Apfc Panel And Connected Works In The Area Of Age E/M Ext (Elect) Under Ge E/M Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair And Maint Of Distribution Transformer Switchgear, Apfc Panel And Connected Works In The Area Of Age E/M Ext (Elect) Under Ge E/M Lucknow. Submission Date for this Tender is 19-04-2023. Switch Gear Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36973338
Corrigendum : Tender For Repair And Maint Of Distribution Transformer Switchgear, Apfc Panel And Connected Works In The Area Of Age E/M Ext (Elect) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
19-04-2023

Tender Details

Repair And Maintenance Of Distribution Transformer Switchgear, Apfc Panel And Connected Works In The Area Of Age E / M Ext ( Elect ) Under Ge E / M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Apr-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-04-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF DISTRIBUTION TRANSFORMER SWITCHGEAR, APFC PANEL AND CONNECTED WORKS IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Supplying /fabrication and fixingin replacement LT panel door made of CRCA MS sheet having thickness 3.15 mm powder coated finish over one coat of red oxideincluding all fixing acessories i.e. suitable size of hinges, nuts, bolts, washers, siliding bolt ,cutting and welding works etc complete all as specified and directed.
2Cleaning the existing painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
3S&F in replacement ACB 3 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type manual, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection, complete all as specified and directed.
4Supply, fixing, connecting andtestingin replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz with spreader including taking down old unserviceable MCCB from LT panel complete as specified and directed.
5Supply, fixing, connecting andtesting in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz with spreaderincluding taking down old unserviceable MCCB from LT panel complete as specified and directed.
6Supply, fixing, connecting andtesting in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz with spreader including taking down old unserviceable MCCB from LT panel complete as specified and directed.
7Supply, fixing, connecting andtesting in replacementMCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz with spreader including taking down old unserviceable MCCB from LT panel complete as specified and directed.
8Supply, fixing, connecting andtestingin replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz with spreader including taking down old unserviceable MCCB from LT panel complete as specified and directed.
9Supply, fixing, connecting andtestingin replacement MCCB 400 Amp 4 pole 36KA 415 volts 50 Hz with spreader including taking down old unserviceable MCCB from LT panel complete as specified and directed.
10S&F in replacementon load change over switch open execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as specified and directed.
11Supply and fixing in replacementDigital VAF+PF meter with RS 485 CL1 in LT panel including taking out old existing unserviceable meter from panels etc complete all as specified and directed.
12Supply and fixingof LED indication lampincluding taking down old unserviceable LED indication lamp from LT panel complete all as specified and directed.
13Supply, installing, testing and commissioning in replacementfactory made , tested , CPRI approvedpowder coatedLT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proofIP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:- (a) Incoming :- (i) ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type ,manualfront operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 800/5 A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i)MCCB 4 pole , 250Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 04 Nos (ii)MCCB 4 pole ,200Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 02 Nos (iii) MCCB 4 pole ,160Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB /ACB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
14All as per item No 13 above but comprising with following:- (a) Incoming :- (i)MCCB 4 pole , 160Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 01 Nos (ii)Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 200/5 A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 250 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i)MCCB 4 pole , 125Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 01 Nos (ii)MCCB 4 pole ,100Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 01 Nos
15All as per item No13 above but comprising with following:- (a) Incoming :- (i)ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type manual front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii)Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 800/ A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i)MCCB 4 pole , 250Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 0 Nos (ii) MCCB 4 pole ,200Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 02 Nos (iii)MCCB 4 pole , 160Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 02 Nos (v) MCCB 4 pole , 125Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 02 Nos
16All as per item No13 above but comprising with following:- (a) Incoming :- (i)MCCB 4 pole , 250Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii)Digital VAF+PF meter with RS 485 CL1 -01No (iii) Ammeter digital type-01No (iv) CTsratio 250/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 200Amps,50 Hz,415 Volts, 36KA thermal magnetic release- 01 Nos (ii) MCCB 4 pole , 100Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 02 Nos
17All as per item No 13 above but comprising with following:- (a) Incoming :- (i)MCCB 4 pole , 400Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 400/5 A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 250Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 01 Nos (ii) MCCB 4 pole , 200Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 02 Nos
18All as per item No13 above but comprising with following:- (a) Incoming :- (i)MCCB 4 pole , 400Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii)On load changeover switch 400 A, 4P, 50 Hz-01 Nos (iii)Digital VAF+PF meter with RS 485 CL1 -01No (iv) CTsratio 400/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 250Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 01 Nos (ii) MCCB 4 pole , 200Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 01 Nos (iii) MCCB 4 pole , 160Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 01 Nos (iv) MCCB 4 pole , 125Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 01 Nos
19All as per item No13 above but comprising with following:- (a) Incoming :- (i)ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type, manualfront operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii)Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 800/5 A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i)MCCB 4 pole , 250Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 03 Nos (ii)MCCB 4 pole , 200Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 02 Nos (iii) MCCB 4 pole , 125Amps,50 Hz,415 Volts, 25 KA thermal magnetic release- 01 Nos
20Supply, install,testingand commissioning in replacementof Indoor type100 kVAr Automatic power factor correction(APFC) Panel. APFC panel with metalised polypropylene capacitor Bank, MPP heavy Duty of capacity 100 KVAR (20x4+10x1+5x1+3x1+2x1) with over current with stand capacity of 3.0I and step banking as per load requirement with minimum 08 steps relay controller microprocessorbased with minimum operating current 11 mA) 3-phase 3-CT operated having provision of multifunctional display, setoptimizing control of capability with having facility of display system voltage, current, active power,apparent power, reactive power, cos phi, power factor (COS, P.F, V, I, KW, KVA, KVAR, THD I % and THD V%upto 33rd level) with alarm output including alarm system and front panel programming including connection with PVC copper cable of suitable size, housed in powder coated PBI sheet housing with hinged door, dust proof and connection with main etc all as directed with following components (all components &capacitors bank shall be housed inenclouser factory made, made out of16SWGMS sheet, indoor in installation dust andvermin proof with suitable ventilating shutters (louvers), powder coatedsheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement with MCCB TP, 160 Amp (25 Ka with TM Release) 01 no. Set of CT,s, Contactor Capacitor duty TP 415 volt with AC Coil including MCBs indicating lamps and bypass system, alarm bell 240v, 50 Hz – 01 No etc complete to achieve point 0.99/1.00 near to unity. Capacitors, switchgears and panel should be manufactured completely in- house and from the same make including copper bus bars of suitablesize, 3 phase system complete all as specified and directed. Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level.
21M&L for making earthing high conductive, non corosive maintenance free, non fluctuation of ohmic value 80 mmX3000mm (inner strip-3000x50x6mm, connection terminal 100x50x6mm, therminal hole 16mm, Inner filling CCM lectrode pipe-B class) GI pipe in pipe filled with super conductive crysteline with earth plus 50 kg containing mixture of graphite, Sulfate, , Silica,ALumina , Iron Oxide, Titanium oxide, calcium oxide , Magnesium oxide , Sodium oxide , Zink oxide etc) back fill compound should be ROHS including heavy duty polymer Earth pit chember with coverand S&F of GI strip 32x6 mmrequired at site for connection of earthing with any type equipmentcomplete all accesories for design modification to achieve the earth terminal rod resistance value below 1 ohm complete all as specified and directed.
Disclaimer :