Military Engineer Services-MES has published Tender For Repair And Maint Of Dg Set And Servo Stabilizer Etc At Haft Chinar And Tattoo Grd Under Ge 970 Ews. Submission Date for this Tender is 11-04-2023. Bath and Body Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Apr-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-04-2023 |
Sl. No. | Item Description |
1 | Disconnecting the engine from base & alternater, and dismantling the top section for top overhauling including replacement of worn out parts,reassembling, connecting with alternator includingtesting for satisfactory running to entire satisfaction of Engr-in-charge, complete all as specified and directed for 100KVA capacity DG set of any make. SM/MES No : 02H/6058/DG/04 (100 KVA Tattoo Ground) |
2 | All as per item No. 1 above but for 62.5 KVA capacity -ditto- SM/MES No : 02H/6056/DG/2013 (62.5 KVATattoo Ground) MAKE-CUMMINS |
3 | All as per item No. 1 above but for 10KVA to 32.5KVA capacity-ditto- SM/MES No : 02H/6046-DG/06,02H/6026-DG/01,02H/6027-DG/01,02H/6030-DG/03,02H/6031-DG/03,02H/6032-DG/03,02H/6033-DG/03, 02H/6028-DG/03,02H/6029-DG/03,02H/6031-DG/04-05 (Haft Chinar) SM/MES No : 02H/6056/DG/01(Tattoo ground) Notes for item Nos 1 to 3 :- 1. Spare parts shall be measured and paid for seperately under respective item of schedule of work. 2. Fixing of spare parts shall deemed to be include in the unit rate quoted by the contractor. |
4 | Supply only cylinder liner with liner ring for DG set of100 KVA capacity SM/MES No. : 02H/6086/DG-10, 02H/6084/DG/10, 02H/6082/DG/10(Tattoo ground) |
5 | All as per item No. 4 above but62.5 KVA capacity |
6 | All as per item No. 4 above but for 10 KVA to 32.5 KVAcapacity |
7 | Supply onlypiston ring set for DG set of100 KVA capacity |
8 | All as per item No. 7 above but62.5 KVA capacity |
9 | All as per item No. 7 above but for 10 KVA to 32.5 KVAcapacity |
10 | Supply onlygasket set with ‘O’ ring set for200KVA/ 125 KVA / 100 KVA capacity of DG Set |
11 | All as per item No. 10 above but62.5 KVA capacity |
12 | All as per item No. 10 above but for10 KVA to 32.5 KVA capacity |
13 | Supply onlyinlet/exhaust valve pair for 100 KVA capacity of DG Set |
14 | All as per item No. 13 above but62.5 KVA capacity |
15 | All as per item No. 13 above but for 10 KVA to 32.5 KVAcapacity |
16 | Supply onlymain bearing set for DG Set of100 KVA capacity |
17 | All as per item No. 16 above but62.5 KVA capacity |
18 | All as per item No. 16 above but for 10 KVA to 32.5 KVAcapacity |
19 | Supply onlymain oil seal (Rear & Front) for DG Set of 100 KVA/62.5 KVA capacity |
20 | All as per item No. 19 above but for 10 KVA to 32.5 KVA capacity |
21 | Supply only flexible coupling for DG set of100 KVAcapacity |
22 | All as per item No. 21 above but62.5 KVA capacity |
23 | All as per item No. 21 above but for 10 KVA to 32.5 KVA capacity |
24 | Supplyonly lub oil filter for DG Set of100 KVA capacity |
25 | All as per item No. 24 above but 62.5 KVA capacity |
26 | All as per item No. 24 above but for 10 KVA to 32.5 KVA capacity |
27 | Supplyonly fuel filter for DG Set of100 KVA capacity |
28 | All as per item No. 27 above but 62.5 KVA capacity |
29 | All as per item No. 27 above but 10KVA to 32.5 KVAcapacity |
30 | Supply only fan belt for DG Set of100 KVA capacity |
31 | All as per item No. 30 above but62.5 KVA capacity |
32 | All as per item No. 30 above but for 10KVA to 32.5 KVA capacity. |
33 | Supply only crank shaft as required 100 KVA DG set of any make and model including testing complete all as specified and directed. |
34 | All as per item No. 33 above but62.5 KVA capacity |
35 | All as per item No. 33 above but10 KVA to 32.5 KVA capacity |
36 | Supplyonly cam shaft as required 100 KVA DG set of any make and model including testing complete all as specified and directed. |
37 | All as per item No. 36 above but62.5 KVA capacity |
38 | Supply only connector rod as required 100 KVA DG set of any make and model complete all as specified and directed. |
39 | All as per item No. 38 above but62.5 KVA capacity |
40 | All as per item No.38 above but for10 KVA to 32.5 KVA capacity. |
41 | Supply onlyhead gasket with ‘O’ ring for 100 KVA capacity of DG Set |
42 | All as per item No. 41 above but 62.5 KVA capacity |
43 | All as per item No. 41 above but for 15 KVA to 32.5 KVA capacity |
44 | Supply only began for200 KVA / 100 KVA capacity of DG Set |
45 | All as per item No. 44 above but82.5/ 62.5 KVA capacity |
46 | All as per item No. 44 above but for 10 KVA to 32.5 KVA capacity |
47 | Supply only main began for 200 KVA/ 100 KVA capacity of DG Set |
48 | All as per item No. 47 above but82.5 KVA / 62.5 KVA capacity |
49 | All as per item No. 47 above but for 10 KVA to 32.5 KVA capacity |
50 | Extracting burnt /unserviceable valve seats of 100 KVA / 200 KVA DG set and re-fixing after cutting grinding and polishing as per new valves including head facing and transporting to and from work shop complete all as specified and directed. |
51 | All as per item No. 50 above but 82.5 KVA / 62.5 KVA capacity -ditto- |
52 | All as per srl item No 50 above but capacity10to 32.5 KVA DG Set -ditto- |
53 | Dismantling and taking down unserviceable fuel injector pump of DG set transporting to work shop for the following repairs and transporting back to site after repair, re-fixing and testing after completion complete all as specified and directed. |
54 | Calibration and complete repair of fuel injector pump of DG set 100 KVA / 200 KVA(Pressure type) on work bench pressure supply of fuel as per standard procedure and testing complete all as specified and directed. |
55 | All as per srl item No 54 here-in-beforebut for 62.5 KVA / 82.5 KVADG set -ditto- |
56 | All as per srl item No 54 here-in-beforebut for capacity 10 KVA to 32.5 KVA DG Set -ditto- |
57 | Dismantling and taking down unserviceable fuel injector nozzle of DG set transporting to work shop for following repairs and transporting back to site re-fixing and testing after completion complete all as specified and directed. |
58 | Overhauling and testing of fuel injector nozzle of DG set of capacity 100 KVA/200 KVA on test bench for fine mist spray including replacement of unserviceable parts complete all as specified and directed. |
59 | All as item no. 58 here-in here-in-beforebut for 62.5 KVA / 82.5 KVADG set -ditto- |
60 | All as item no. 58 here-in here-in-beforebut for 10 KVA to 32.5 KVA DG set -ditto- |
61 | Taking down old unserviceable turbo charger carefully and supply and fixing newturbo charger for DG set of capacity 62.5 to100 KVAcomplete all as specified and directed. |
62 | Taking down radiator complete from its mounting, disludging top and bottom tank, cleaning complete tube by descaling solution and finally re-installing in original position complete all as specified and directed for 15 KVA to 125 KVA |
63 | Preparation and Painting of complete DG set including frameby two coats of enamelled paint as per colour code by spray painting and marking etc complete all as specified and directed for 62.5 KVA to 200KVA. |
64 | Preparation and Painting of completeDG set including frameby two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 10 KVA to 32.5 KVA. |
65 | Dismantling alternator from the engine base for repairing including transporting to workshop and transport back to site after repair, reinstalling, reconnecting with engine including testing on load for 15 KVA to 32.5 KVA DG set complete all as specified and directed. |
66 | All as item no. 65 here-in here-in-beforebut for 62.5 KVA to 125 KVA DG set -ditto- |
67 | Rewinding of armature with super enamelled copper wire of required size including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 100 KVA / 200 KVA complete all as specified and directed. |
68 | All as item no. 67 here-in-beforebut for 62.5 KVA / 82.5 KVADG set -ditto- |
69 | All as per srl item No 67here-in-beforebut for15 KVA to 32.5 KVA DG set -ditto- |
70 | Rewinding of field coils of alternator with super enamelled copper wireincluding varnishingand heating including reassembling and testing for capacity of DG Set 100 KVA/ 200 KVA complete all as specified and directed. |
71 | All as item No 70 here-in-before but for 62.5 KVA / 82.5 KVA DG set -ditto- |
72 | All as item No 70 here-in-before but for 10 KVA to 32.5 KVA DG set -ditto- |
73 | Dismantling and taking down unserviceable self starter transporting to work shop for the repair and transporting back to site after completerepairs re-installation at site and testing after completion complete all as specified and directed. |
74 | Repair to self starter including rewinding the coil winding, bearing pinion bush solenoid switch carbon brush and holder etc and testing after repair complete all as specified and directed of 100 KVA /200 KVAcapacity DG Set. |
75 | All as item No 74 here-in-before, but for 62.5 KVA / 82.5 KVADG set-ditto- |
76 | All as item No 74 here-in-before, but for 15 KVA to 32.5 KVA DG set-ditto- |
77 | Dismantling and taking out olddynamo and transporting to workshop forrepairand transporting back to site after complete repair re-installing at site and testing complete all as specified and directed. |
78 | Repair to Dynamo of DG Set of capacity 100 KVA /200 KVA including rewinding of coil, replacement of GM Bush, housing plate, cutout plate etcand testing after repair complete all as specified and directed. |
79 | All as item No 78 here-in-before, but for 82.5 KVA/ 62.5 KVA DG set -ditto- |
80 | All as item No 78 here-in-before, but for 15KVA to 32 KVA DG set -ditto- |
81 | Supply and fixing in repair 12 V self starter for 62.5 KVA / 82.5 KVADG set. |
82 | Supply and fixing in repair 12 V self starter for 15KVA to 32.5 KVA DG set. |
83 | Supply and fixing in repair 12 V self starter for 100 KVA / 200 KVA DG set. |
84 | Supply and fixing in repair dynamo for 62.5 KVA/ 82.5 KVADG set. |
85 | Supply and fixing in repair dynamo for 15 KVA to 32.5 KVA DG set. |
86 | Supply and filling in replacement of engine oil including cleaning of engine oil chamber and replacement of gasket etc complete all as specified and directed. |
87 | Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity100 KVA to 350 KVA to workshop for repair,strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories, replacement of worn out parts, including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- New parts shall be measured and paid for separately under respective items as supply only) |
88 | Supply only digital voltmeter 0 to 500 volts96x96mm flush type |
89 | Supply only LT current transformer ratio as per existing rating in LT panels |
90 | Supply only Auto/Manual selector switch of voltmeter/ammeter in LT panel boards |
91 | PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity upto 25 KVAas per site requirement for type and make complete all as specified and directed. |
92 | All as per item No 91 here-in before but of capacity 100 KVA to 350 KVA |
93 | Taking down old burnt winding and replacement of Booster coil 100 KVA -03 Nos Dimmer coil 200Ams -03 Nos, carbone brush 200 Ams-03 Nos, Digitalmicro processorcentral card, 10 Kg Togrg RC plate including leathriede paper cotton tape, winding varnishes etc for stabilizeroil immersed type of capacity100KVA to 350 KVA by using suitable gauge super enamelled copper conductor as per existing winding complete all as specified and directed. |
94 | Supply only insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV complete all as specified and directed. |
95 | Dehydration of transformer oil upto BDV not less than 50 KV all as specified and directed. |
96 | Cast iron dimmer gear set for automatic voltage correction capacity 100 KVA to 350 KVA with as per site requirement for type and make complete all as specified and directed. |
97 | Micro limit switch with cam lever complete for servo stabilizer of capacity 100 KVA to 350 KVA as per site requirement for type and make complete all as specified and directed. |
98 | Replacement ofindicator assembly LED type (RYB) for LT panel boards |
99 | Replacement of servo motor synchronous type of torgue capacity30 Kg for automatic voltage correction suitable for servo stabilizer of capacity 100 KVA to 350 KVA as per site requirement for type and make complete all as specified and directed. |
100 | Servo Dimmer 200 Amps/Booster83 KAA coil for automatic voltage correction suitable for servo stabilizer of capacity 100 KVA to 350 KVA as per site requirement for type and make complete all as specified and directed. |
101 | Carbon brush with holder assembly for servo stabilizer of capacity 100 KVA to 350 KVA as per site requirement for type and make complete all as specified and directed. |
102 | Replacement ofdigital Amp meter ofexisting range and size96x96mm flush type in servo stabilizers |
103 | Bush rod brass for servo stabilizer of capacity 100 KVA to 350 KVA as per site requirement for type and make complete all as specified and directed. |
104 | Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 100 KVA to250 kVA complete all as specified and directed. |
105 | Supply only over load relay for 100 to350 KVAvoltage stabilizer. |
106 | Supply only graphite carbon bursh suitable for Servo voltage stabilizer of any capacity complete all as specified and directed. |
107 | Capacitor of capacity 1.42 to 4.0 MF + 5%, 440V, AC 50Hz, complete all as specified and directed. |
108 | Supply only Pinion with gear (Medium) suitable for servo stablizer of any capacity, complete all as specified and directed. |
109 | Supply only Pulsing Transformer heavy duty suiable for servo stablizer of any capacity complete all as specified and directed. |
110 | Supply only Control Transformer heavy duty suiable for servo stablizer of any capacity complete all as specified and directed. |
111 | Material and labour in repair for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size , by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6mm earth lead protected by provision of GI medium grade pipe 40mm bore including porovision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less thanb 4 Kg/Sqm) and frame of angle iron 25x25x3mm with lugs-02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50m long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplys soil to a distance not exceeding 50m, all as per electrical plate No 3 of SSR-2009 Part-I and connection to earth test point all as specified and testing on completion. Note:- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 32x6mm size and protection pipe of 40mm bore GI medium grade. |
112 | Off Load change over switch 200 Amps, 4 Pole madeout of Sheet steel enclosure including replacement of incoming and outgoinglugs and fixing arrangement on panel/wall complete after taking down old one all as specified and directed. Make:- Havells/Standard/HPL/L&T |
113 | All as per srl item No. 112 here-in-before but of 63 Amps capacity -ditto- Make:- Havells/Standard/HPL/L&T |
114 | Copper cable insulated unsheathed multistranded of size 10 Sqmm single core complete all as specified and directed. |
115 | Supply and fixing of moulded case circuit breaker four pole 63 Amps 16 KA capacity 415V 50Hzincl taking out the old unserviceable complete all as specified and directed. Havells cat part No IHLGNF0063 or equivlent in L&T/Schinder/CG |
116 | Supply and fixing of moulded case circuit breaker four pole 100 Amps 25KA capacity 415V 50Hzincl taking out the old unserviceable complete all as specified and directed. Havells cat part No IHLGHDAS0100 or equivlent in L&T/Schinder/CG |
117 | Supply only AVR suitable for DG set of capacity10 KVA to100 KVA. |
118 | Supply only Air filter suitable for DG set of capacity 15KVA to200 KVA |
119 | Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity3 KVA to 5 KVA to workshop for repair,strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories, replacement of worn out parts, including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- New parts shall be measured and paid for separately under respective items as supply only) |
120 | Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity10 KVA to 25 KVA to workshop for repair,strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories, replacement of worn out parts, including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- New parts shall be measured and paid for separately under respective items as supply only) |
121 | Repair to unserviceable/burnt LT stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED"s etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge. |
122 | Repair to unserviceable/burnt LT stabilizer of 10 KVA to 25 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED"s etc. and making fully functionalcomplete all specified and directed by Engr- in-charge. |
123 | Supply only over load relay for 3 to5 KVAvoltage stabilizer. |
124 | Supply only over load relay for 10 to25 KVAvoltage stabilizer. |
125 | Supply and fixing in repair including testing and commissioning of CPRI approved LT panel board, indoor, cubical, dust and vermin proof made out of 2mm thick MS sheet and steel section with back door detachable type fitted with nuts, bolts and washers and frint doors openable type fitted with knobs and hinges CRCA sheet IP-43 grade protcetion and having locking arrangement including individual chamber for MCB and MCCBs having sufficient space for working. LT Panel shall be prewired with suitable size OVC insulated cipper conductor cable. The panel shall be powder coated and shall bemounted on angle iron frame made out of MS angle of size 50x50x6mm of height 30CM from floor level. (Tatto Ground -03 Nos, Haft Chinar- 02) The panel shall be comprising the following items and cost of following items shall deemed to be include in this unit rate :- |
126 | MCCB125 Amps 25 KA, 415volts four pole with adjustable thermal setting - 01 No (Incomer) Make : Indoasian or equivalent in CG/Havells |
127 | MCCB 63 Amps 16 KA, 415volts four pole with adjustable thermal setting - 02Nos Make : Indoasian or equivalent in CG/Havells |
128 | Digital Voltmeter 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No Make : Bajaj or equvalent in CG/Havells |
129 | Digital Ameter with CTs 0-200 Amp range 96x96 Sqmm size with four way selector switch - 01 No Make : Bajaj or equvalent in CG/Havells |
130 | LED Indication Lamp - 03Nos Make : Bajaj or equvalent in CG/Havells |
131 | Aluminium strip bus bar sleeve insulated 300 amps capacity four pole mounted on epoxy insulators - 01 No |
132 | Cable entry with double comprissioning glands and two with provision of two Nos earthing terminals. |
133 | Internal wiring of panel board with single core copper cable PVC insulated of suitable size and control fuses. |
134 | ON Load Changeover switch of 4 pole, 415 volt, 200 Amps capacity - 01 No |
135 | Supply and fixing in repair including testing and commissioning of CPRI approved LT panel board, outdoor, cubical, dust and vermin proof made out of 3.15 mm thick MS sheet and steel section with back door detachable type fitted with nuts, bolts and washers and frint doors openable type fitted with knobs and hinges CRCA sheet IP-43 grade protcetion and having locking arrangement including individual chamber for MCB and MCCBs having sufficient space for working. LT Panel shall be prewired with suitable size OVC insulated cipper conductor cable. The panel shall be powder coated and shall bemounted on angle iron frame made out of MS angle of size 50x50x6mm of height 30CM from floor level.Location :- Tattoo ground- 1, Haft Chinar - 1 The panel shall be comprising the following items and cost of following items shall deemed to be include in this unit rate :- |
136 | MCCB400 Amps 35 KA, 415volts four pole with adjustable thermal setting - 01 No (Incomer) Make : Indoasian or equivalent in CG/Havells |
137 | MCCB 100 Amps 25 KA, 415volts four pole with adjustable thermal setting - 02NosMake : Indoasian or equivalent in CG/Havells |
138 | MCCB 200 Amps 25 KA, 415volts four pole with adjustable thermal setting - 01Nos Make : Indoasian or equivalent in CG/Havells |
139 | Digital Voltmeter 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 NoMake : Bajaj or equvalent in CG/Havells |
140 | Digital Ameter with CTs 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No Make : Bajaj or equvalent in CG/Havells |
141 | LED Indication Lamp - 03Nos Make : Bajaj or equvalent in CG/Havells |
142 | Aluminium strip bus bar sleeve insulated 600 amps capacity four pole mounted on epoxy insulators - 01 No |
143 | Cable entry with double comprissioning glands and two with provision of two Nos earthing terminals. |
144 | Internal wiring of panel board with single core copper cable PVC insulated of suitable size and control fuses. |
145 | Taking out old UNSV and Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes,complete all as specified and directed :- Note :- Excavation, earthwork, sand cushioning and brick protection shall be measured and paid for separately. |
146 | All as item No 145 but XLPE insulated 16 Sqmm 2 Core. |
147 | All as item No 145 but XLPE insulated 25 Sqmm 3.5 Core. |
148 | All as item No 145 but XLPE insulated 35 Sqmm 3.5 Core. |
149 | All as item No 145 but XLPE insulated50 Sqmm 3.5 Core. |
150 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in soft/loose soil complete all as specified and directed |
151 | Returning, filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer complete all as specified and directed |
152 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed |
153 | M&L for filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches complete all as specified and directed |
154 | M/Lfor brickwell burntlocallyavailablesubclass "B" laid over sand cushioningtocableintrencheskeepingwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected. |
155 | S & F inrepair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 45W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed. Make : Havells LHETAXU7PNJ045 or equiavalent in Phiips/ Crompoton. |
156 | S & F in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed. Make : Havells LHETAXU7PNJ090 or equiavalent in Phiips/ Crompoton. |
157 | supply and fixing inrepair of LED based saving & enviorment friendly long life versatile flood light Lumos IP-65of 100 W complete with front glass cover complete as specified. Make Bajaj Cat part No . BJFL 100W LED I WHITE or its equivalent make of philips/CG |
158 | supply and fixing in repair of LED based saving & enviorment friendly long life versatile flood light Lumos IP-65of 120 W complete with front glass cover complete as specified. Make Bajaj Cat part No . BJFL 120W LED I WHITE or its equivalent make of philips/CG |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy