| 1 | PART-ISupplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in Existing/Fresh / recessedPVC conduit/casingas required forlight points and circuits.(Excluding cost of conduiting/casing). |
| 2 | 3 x 1.5 sq. mm |
| 3 | P/f ofPhenolic Laminated Sheet 3 mm thick of differents sizes 6\"X9\", 5\"X5\", 10\"X8\",12\"10\" with cutting of space for fixing of switches, socket outlet 5/6 A and for 15/16A switch and socket with screws & roval plugs etc. (2 no 15A socket & switch & 02 no 5A socket & switch below mentioned in item no 04 to be fixed in one plate in ICU = 8 nos for medical equiements). Excluding the cost of Switch sockets. |
| 4 | P/F of piano type switch F/T 15/16 A |
| 5 | P/F of piano type socket F/T6 pin 15/16 A |
| 6 | P/F of piano type switch F/T 5/6 A |
| 7 | P/F of piano type 3 pin socket F/T 5/6 A |
| 8 | P/F ofpiano type 3 Pin Top 15/16A |
| 9 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in fresh/ existing recessed/surfacePVC conduit /casing as required. For light point circuits and15/16 A power points and Sub Mains..(Excluding cost of conduiting/casing). |
| 10 | 3 X 2.5 sq. mmmm(for 15/16 A power points & Circuit wire for light points. |
| 11 | 3 X 4 sq. mm for (15/16 A power points) |
| 12 | 3 X 6 sq. mm as main |
| 13 | Supplying and fixing of 25 mm size of double locked channel for light points, power points and circuit wires. Whereever necessary. |
| 14 | Supplying and fixing of 25 mm sizes of medium class PVC conduit alongwithaccessoriesin surface as required For 15/16A Socket out let and circuit wires where ever necessary for a bove mentioned Light points and circuits. |
| 15 | Supplying and fixing of 25 mm sizes of medium class PVC conduit alongwithaccessoriesin recessed as required manner For 15/16A Socket out let and circuit wires where ever necessary for a bove mentioned Light points and circuits. The job includes cost of cheasingrough plastering complete as required. |
| 16 | P/F ofLED4feet long batten 6000/6500k Light having extruded aluminium body with anti-glare diffuser with energy efficient electronic driverCRI =80 with minimum sytem lumens 2000 and maximum wattage 20 , IP 20 , surge proctection 2KV or more including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours greater than 50000 Hours. |
| 17 | P/F of LED4 feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driverCRI = 80 with minimum sytem lumens 4000 and maximum wattage 40 , IP 20 , surge protection 2KV or moreincluding connection with multistrand copper conductor 3core cable etc as required at site with burning hours greater than 50000 Hours. |
| 18 | P/F of Recessed type LED lumanaries circular type slim decorated aluminium casted and separate electronic driver with system temeprature 6000/6500 K and robust construction in combination with flat diffuser minimum system lumens 1000 with burning hours grater than 40000. |
| 19 | P/F of Surface type LED lumanaries circular type slim decorated aluminium casted and separate electronic driver with system temeprature 6000/6500 K and robust construction in combination with flat diffuser minimum system lumens 1000 with burning hours grater than 40000. |
| 20 | Supply installation testing and commissioning of matalic type300 mm dia Exhaust fan along with bird guard to protect fan,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM, voltage -220 to 240 Volts Air delivery 1600 Mhr/min |
| 21 | P/F ofplastic bodyExhaust Fan along withShutter type 250mm dia. |
| 22 | P/F of wooden frame fabricated from12mm thick plyboard siutable for above mentioned exhaust fan. Completein all respects. |
| 23 | Supplying and fixing Single pole 5 A to 32 Arating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of singlepoles in the existing/ newMCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Supplying and fixing Doublepole rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of singlepoles in the existing/ newMCB DB complete with connections, testing and commissioning etc. as required. |
| 25 | 32 A |
| 26 | 40 A |
| 27 | Supplying and fixing of 16 wayDouble door, single poleand neutral, sheet steel, MCB disreibution board, 240V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB). |
| 28 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod with fan hook etc. 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.The job includes the cost of dismantling of existing non functional ceiling fans wherever necessary. |
| 29 | PART -II |
| 30 | Supply, mechanical and manual transportation and Erection of11 meters ST Pole(ST 410 SP 56 ) complete with Base Plate and top Cap Confirming to IS 2713 with upto date ammendments complete with red oxide coat and Aluminium PaintCoat. The job includes cost of Stone Pad along with cement concrete 1:2:4(1 cement : 2coarse sand : 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required as per REC Stardard 0.6 cum for 11 mtr. The job includes cost of 3 mtr long 40mm dia GIpipeand G I Strip of Size 25 x3 mm for pole earthing. |
| 31 | Painting of 10 No. S.Tpoles with Red oxide and aluminium paint(two coats pf each red oxide and aluminium paint with the help of brush and proper sand papering of each pole etc.) |
| 32 | Fabrication ,Supply and Erection of G.I. RingBracketwith dia 1200 mm on top of 11 Mtr S.T. Polesmade out of G.I Pipehaving thickness of 2mm, 40mm dia along with suitable arrangement formounting ofbelow mentioned LED Flood lights on the same. Complete as required at site |
| 33 | Supplying and embedding 40 mm G.I Pipe having Dia 40mm in pole collar foundation (during casting) for cable entry including bending the pipe to required shapecomplete as required. |
| 34 | Supply, installation, testing and commisioning of LED flood light luminariesin place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V 2.Lumens : Min 10500 3. Power factor : >0.90 4. Life expecting : more than 40,000 hours5. No of hours usage / day : 10 to 12 hours/day6. Rated watt : 110-120W7. Luminous flux : 10500 to 12000 lumens 8. Colour Temperature : 5,500 to 6,500 K with test certificate9. Ingress protection : IP 65/IP 66 as per IS/IEC60529-2001 with test certificate.10. Total harmonic distortion (THD): <15% with test certificate11. Colour rendering index : Ra > 8012. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture. |
| 35 | Providing, installation, testing and commissioning of LED Street lightluminaireas per following specification:- 1. Input voltage : 150 V to 270 V2. LDE lamp efficiency : Min 95 to 110 lumens/watt3. Power factor : >0.904. Life expecting : 50,000 hours5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 %15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 36 | Supplying and drawing 3x1.5 mm sq. sizes of FRLS PVC insulatedcopper conductor, single core cablethrough in street light poleas required. |
| 37 | P/F of looping box (sheet steel) complete with lockable, hinged type door, gas kitted, clips, nuts and bolts, MCB strip neautral connection, earthing nut bolt for above street lighting |
| 38 | Supplying and fixing 5 A or 10 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Providing and laying of spans of 10 sq mm 2 core XLPE Al. cable Armoredfresh ones. 1.1KV for above street lights. The job includes the cost of excavation , refilling the trench complete as required. |
| 40 | Supplying and fixing Cable Collars/ Wall Clamps of G.I Flat size 300x100 x6 mm with 04 no fasters on eachfor fixing 400 mm2 and 300 mm2olong the boundary wall From Entrance upto JK Bank ATM insdie MCH Bemina. |
| 41 | Dis connecting , Dismantling, cutting and shiftingof existing 11 mtr S.T Pole along with existing flood lights. The job includes the cost ofRe- Erection of high mask bracket ring alongwith 04 No flood lightson existing9 meter ST pole. |