Tender For Construction Of G Plus 1 Building For Central Instrumentation Facility At Gauhati University, Kamrup Metro-Assam

University Gauhati University-UGU has published Tender For Construction Of G Plus 1 Building For Central Instrumentation Facility At Gauhati University. Submission Date for this Tender is 10-04-2023. Building Work Tenders in Kamrup Metro Assam. Bidders can get complete Tender details and download the document.




Tender Notice

36959131
Tender For Construction Of G Plus 1 Building For Central Instrumentation Facility At Gauhati University
Open Tender
Indian
Assam
Kamrup Metro
10-04-2023

Tender Details

Construction Of G Plus 1 Building For Central Instrumentation Facility At Gauhati University

Key Value

Document Fees
INR 10000 /-
EMD
INR 1240000.0 /-
Tender Value
INR 6.20 Crore /-

BOQ Items

Name of Work: Construction of G+1 building for Central Instrumentation Facility at Gauhati University
Sl. No. Item Description
1CIVIL WORK
2EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : Ordinary rock
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil.
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
7Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
8Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
9Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
10Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
11CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
12Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
13REINFORCEDCEMENT CONCRETE Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
14Columns, Pillars, Piers, Abutments, Posts and Struts, beams
15Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
16Suspended floors, roofs, landings, balconies and access platform
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeabove plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
19Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost ofentering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
20All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
21Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
22BRICKWORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) Cement mortar 1:4 (1 cement : 6 coarse sand)
24Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
25STEEL WORK Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. :Hot finished welded type tubes
26Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. Tube
27Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc
28DOOR WINDOW Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)
29Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm).
30Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
31For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
32Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
33Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood with duco paint on both faces of shutters. (including of allhardware like s. s tower bolt , mortice lock , s.s handle door stopperwith paint /polish . 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
3435 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge NoN Decorative finish (matt finish)
35Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer"s specification and direction of Engineer-in-charge
36Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete 250x10 mm
37Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
38Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
39Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
40Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
41Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopperetc.to be paid separately
42Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately)
43Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
44Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete
45FLOORING Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
46Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
47Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
48Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
49Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete Granite stone slab all colour and texture except black, Cherry/ Ruby red Area of slab over 0.50 sqm
50Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
51Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
52Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete Granite of any colour and shade Area of slab upto 0.50 sqm
53Area of slab over 0.50 sqm
54FINISHING WORK 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
5512 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
566 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
57Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
58Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
59Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
60Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
61Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
62Plinth Protection All charges for making plinth protection 50mm thick of cement concrete 1:3:6(1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth complete in all respect as directed.
63WATER PROOFING Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (Contd.....)
64(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
65Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
66Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
67Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
68Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
69ROOFING SHEET & ACCESSORIES Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
70Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
71Barge board (Upto 300 mm)
72AREA DEVELOPMENT Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
73Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin- Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 200 mm thick
74Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification layer including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. Total 200mm thick to be done 2 layers of 100mm & 100mm
75Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
76Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
77SANITARY & WATER SUPPLY WORKS
78SANITARY INSTALLATIONS Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
79Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
80Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
81Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
82Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
83Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
84Providing and fixing toilet paper holder : C.P. brass
85Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
86Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe
87Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe
88For 75 mm dia pipe
89Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729
9075 mm dia Sand cast iron S&S as per IS - 1729
91Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS - 1729
9275 mm dia Sand cast iron S&S as per IS - 1729
93Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 1729
9475 mm Sand cast iron S&S as per IS - 1729
95Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia
96Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
9740 mm dia
98Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming ro IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter.
99Providing and fixing wall faced unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving10mm gap for thermal expansion. Bend 87.5° 110mm bend.
100Shoe (Plain) 110mm Shoe.
101Providing and fixing unplasticised PVC pipe clip of approved design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required lingth, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm.
102Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
103Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
104Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
105Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
106WATER SUPPLY C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
10740 mm nominal outer dia Pipes
10850 mm nominal outer dia Pipes
109Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
11020 mm nominal outer dia Pipes
11132 mm nominal outer dia Pipes
112BRASS FITTINGS Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
113Providing and fixing brass stop cock of approved quality 20 mm nominal bore
114Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
11550 mm nominal bore.
116Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
117Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
118Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia with 25 mm waste hole
119Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
120DRAINAGE Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
121Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
122Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
123Providing, fixing, testing and commissioning of uPVC SWR pipe confirming to IS-13592, Type-B cut to required lengths including all necessary fittings and special such as bends, junctions offset, access pieces (plain or door), Tees, bends, reducers, flanges, plugs unions and clamps Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated including chasing, cutting and making good the walls / floor etc. whereverrequired a)110 mmO.D type "B"
124Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams.
125Providing and fixing uPVC cowl complete including cutting and making good the walls and floors wherever required. a) 110 OD
126ELECTRICAL WORK
127WIRING Copper wiring in PVC Conduit : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
128Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
129Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1302 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1312 X 4 sq. mm + 1 X 4 sq. mm earth wire
1322 X 6 sq. mm + 1 X 6 sq. mm earth wire
1332 X 10 sq. mm + 1 X 10 sq. mm earth wire
1344 X 10 sq. mm + 2 X 10 sq. mm earth wire
135Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as requir 1 pair
1362 pair
137Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required
138Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
139Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
14025 mm
141Supplying and fixing metal box of following sizes (normal) on surface or recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm x 100 mm x 60 mm deep
142180 mm x 100 mm x 60 mm deep
143Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
1443 pin 5/6 A socket outlet
145Telephone socket outlet
146TV antenna socket outlet
147Bell push
148Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
149Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
150Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
151Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
1523 Module
153Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
154Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
155Supplying and fixing call bell / buzzer suitable for DC/AC single phase, 230 volts complete as required.
156Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
157Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
158MCCB, MCB & DB"S Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 30/25KA, FP MCCB
159Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
160Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCB/MCCBs (but without MCCB/MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
161Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
162Triple pole
163Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
164Supplying and Fixing Singe Pole Blanking Plate in the existing MCB DB complete etc. as required.
165Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
166Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
167Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 4 way, Double door TPN MCBDB
168For 6 way, Double door TPN MCBDB
169Providing and fixing M.V.danger notice plate of 200 mmx 150 mm,made of mild steel at least 2 mm thick and vitreous enamelled white on both side and with inscription in single red colour on front side as required.
170CABLE TRAYS Hot Dipped Galvanized Iron Cable Tray Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
171Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
172Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
173EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
174Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Metre long etc. with charcoal/ coke and salt as required.
175Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
176Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
177Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
178Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
179Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
180Providing and fixing 4mm dia.copper wire on surface or in recess for loop earthing as required.
181LIGHTNING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
182Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
183Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
184Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
185Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as required.
186MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm)
187MAIN LT PANEL Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Incommer: a) 800 A ,4P, MCCB, 50 KA - 2 Nos. b)800 A, 4P, on-load Changeover switch - 1 No c)Digital Ammeter - 2 Nos d)Digital Voltmeter -2 Nos e)CT 800/5 -2 Sets f)Switch Fuse Unit - 6 Nos (Contd.....)
188g)Selector Switch - 4 Nos h) Indicating Lamp 2 Sets i) Bus-Bars: 1440 A TPN electrolytic AL. Bus Bar of uniform cross-section (2nos.X60mmx10mm) – 1 set Outgoing: j) 400 A 4P MCCB 36 KA – 3 Nos. k) 250A 4P MCCB 25 KA –1 No. l) 100A 4P MCCB 25 KA –1 No. m) 40 A 4P MCCB 25 KA –1 No. n) 40A 4P MCB - 6 Nos
189SUB MAIN LT PANEL-[GROUND FLOOR ] Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Incommer: a) 400 A 4P MCCB 36 KA – 1 No. b) Digital Ammeter - 1 No (Contd......)
190c) Digital Voltmeter -1 No d) CT 400/5 -1 Set e) Switch Fuse Unit - 3 Nos f) Selector Switch - 2 Nos g) Indicating Lamp -1 Set h) Bus-Bars: 720 A TPN electrolytic AL. Bus Bar of uniform cross-section (60mmx10mm) – 1 set Outgoing: i) 100A 4P MCCB 25 KA –6 Nos. j) 63A 4P MCCB 25 KA –1 No. k) 40A 4P MCB - 2 Nos l) 40A DP MCB - 9 Nos
191SUB MAIN LT PANEL-[FIRST FLOOR] Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Incommer: a) 400 A 4P MCCB 36 KA – 1 No. b) Digital Ammeter - 1 No c) Digital Voltmeter -1 No (contd....)
192d) CT 400/5 -1 Set e) Switch Fuse Unit - 3 Nos f) Selector Switch - 2 Nos g) Indicating Lamp -1 Set h) Bus-Bars: 720 A TPN electrolytic AL. Bus Bar of uniform cross-section (60mmx10mm) – 1 set Outgoing: i) 100A 4P MCCB 25 KA –7 Nos. j) 63A4P MCCB 25 KA –1 No. k) 40A 4P MCB - 2 Nos l) 40A DP MCB - 9 Nos
193SUB MAIN LT PANEL-[SECOND FLOOR] Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Incommer: a) 250 A 4P MCCB 36 KA – 1 No. b) Digital Ammeter - 1 No c) Digital Voltmeter -1 No (Contd....)
194d) CT 200/5 -1 Set e) Switch Fuse Unit - 3 Nos f) Selector Switch - 2 Nos g) Indicating Lamp -1 Set h) Bus-Bars: 360 A TPN electrolytic AL. Bus Bar of uniform cross-section (30mmx10mm) – 1 set Outgoing: i) 100A 4P MCCB 25 KA –2 Nos. j) 40A 4P MCB - 3 Nos k) 40A DP MCB - 6 Nos
195CABLE Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . a) 70.00 mm² 3½ core U.G. Cable
196b) 120.00 mm² 3½ core U.G. Cable
197Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
198LIGHTING FITTING & FIXURES Supplying of pre-wired fluorescent lighting fixure (BAJAJ / CROMPTON/PHILIPS make) complete with Fourescent Tubes/CFL lamps etc. as required complete Superior finish extruded LED Batten white powder coated pressure die cast aluminium body with High transmitivity, non Yellowing PMMA diffuser with driver and accessories pre-wired upto terminal block assembly. LED Luminaires of make PHILIPS Cat No. BN021C LED20S PSU CDL G LED 18W or equivalent inlcuding lamps etc. complete [TL]
199Supplying, installation, testing and Commission of the following indoor Decorative Recess mountedLEDdown lighter luminaries of model no-DN 393 B LED 12 S-6500 PSU WH / D01257R000 / D01240R000 /D01230R000/ CRDL11R017HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar/ LT / Wipro make). [DL]
200Supplying, installation, testing and Commission of the following indoor Decorative Recessed mounted 2" x 2" LEDdown lighter luminaries of Make:- PHILIPS model no- RC380 B LED 36S-6500 G4 L60 PSD OD WH OC /RC380 B LED 36S-6500 G4 L60 PSD OD WH OC / LCTRS-36-TL / LCTRS-36-CDL / IO2830RP00 / IO2840RP00 / IO2850RP00complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Crompton / LT make). [CLS]
201Supplying, installation, testing and Commission of the following indoor Decorative Square Type Surface mounted LEDdown lighter luminaries of Make:- PHILIPS model no-SM251C LED 16S -6500PSU WH complete with all accessories such as ballast, starter etc. In the ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department (Jaquar / Wipro make). [CLT]
202Supplying, installation, testing and Commission of the following indoor Decorative Ceiling Hanging Pendant mountedLEDluminaries with spun aluminium reflector and high performance is suitable for accent and functional lightingof Make WIPRO model no-LH13-301-060-57-XX 32Watt complete with all accessories such as ballast, starter etc. In the ceilingor similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Wipro make). [CH]
203Supplying with fitting and fixing of Single Phase Modular Motor Starter switch Range 16 - 25 Amps in 3 ModuleMODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
204Supplying of 1200 mm sweep Ceiling fan of make HAVELLS Cat/Brand Cat/PACER Ceiling Fan of colour White, Brown or Bianco complete with down rod or equivalent etc. [F]
205Supplying and fixing of 400 mm sweep Wall fan of make HAVELLS Cat/Brand SwingWall Fan of colour White, Brown or Bianco complete with down rod or equivalent etc. [WF]
206Supplying of 300 mm sweep exhaust fan of make HAVELLS Cat/Brand VENTIL AIR -DS complete with all accessories complete or equivalent. [EF]
207MCB Supplying and fixing following rating, Double pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps
208Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps
209Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps
210Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB enclosure incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.(Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) a) 2 way single door
211b) 4 way single door
212Supplying with fitting and fixing of CAT 6 RJ-45 Computer jack in one module MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
213Wiring to a secondary point Wiring for secondary light point with 1.5 sq mm insulated (ISI or equivalent) HFFR Copper Conductor Cable in recessed P.V.C. conduit of as required with ceiling rose as directed by the department.
214Computer Point Power wiring Wiring for Modular type Socket points with Modular type Switch including supply of the switch and socket in PVC conduit of IS specificationof proper size with 3 nos of 2.5 sqmm single core PVC insulated stranded copper wire 1.1 KV grade and with all material supply installation and commissioning complete from MCB Distribution Board. The wiring shall be carried out on surface above false ceiling by chiselling the existing surface and plastering the existing surface and plastering the same with cement etc. after fixing the conduit with all accessories like saddles, screws, bends T joints etc. 2 coat of painting matching to the surface including supply installing, testing and commissioning of modular plate type switch and socket for computer terminal on sheet steel enclosure (cadmium plated), duly fitted with screw to the steel conduit and fixed to the wall partition furniture with all interconnection and proper earthing. All the opening shall be covered with blank plate and be sealed to make the box vermin proof. With 3 nos of2/3 pin combined 6A socket with single 6 A switch. [SOC]
215Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
216INVERTER/ UPS Supplying including installation of Inverter (NUMERIC/ Microtech/ V-Guard/ Luminous) with Battery and its case as per direction and specified by the Deptt. 7.5 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology230V AC Input (160V – 280V A 1 Ph input- 1 Ph outputWith Isolation Transformer6KW output with 0.8 output PF30 min backup using SMF battery
217Supplying including installation of Inverter (NUMERIC/ Microtech/ V-Guard/ Luminous) with Battery and its case as per direction and specified by the Deptt. 15 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology360V AC Input (300V – 470V A 3 Ph input- 1 Ph outputWith Isolation Transformer12KW output with 0.8 output PF30 min backup using SMF battery
218DATA CABLING AND FIXURES Patch Cord Cat 6 UTP Gray 1m - Moulded SCHNEIDER/ LEGRAND or equivalent
219Patch Cord Cat 6 UTP Gray 2m - Moulded SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt..
220Patch Panel Cat 6 UTP Keystone -24 Port- Loaded SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt..
221Patch Panel Cat 6A UTP Keystone -12 Port- Loaded SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt..
222APW Flexi box Wall mount Rack 12U 600 X 550mmD Networking Wall mount Rack with Front Tinted Glass Door with Lock "PDU 6*5A - 01 Nos.Fan 90 cfm 230V - 01 Nos. Mounting Hardware (Set of 10) - 1 Set 19"" 1U Cable Manager - 1 Nos."
223APW Cyber Rack Server Rack 42U APW President Enclosure, 600mm W CYBERACK 42U / 1000mm D (CRCA Steel Frame with Aluminium Profiles & 2 Nos. of Removable Side Panels with following items: - Top cover with cable entry -1no. - Bottom cover with cable entry -1no. - 19” Mounting Angles – 2 pairs. ,Finish :  Powder coated to 80 microns; Matt  finish. colour : BLACK with , Load rating capacity -- 500 kgs., Front side vented glass door and rear full perforated steel door with locks. "PDU 10*5/15A - 01 NosFan Housing Unit with 4 Fans - 01 SetMounting Hardware (Set of 20) - 1 SetCastor with Brake - 2 Nos.Castor without Brake - 2 Nos.Earthing Kit - 01 Set"
224Supplying ,installation, testing & commissioning of Distribution Box 20 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)
225Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
226Supply, Fitting Fixing of Shock Treatment Chart
227External Electrical Works EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
228Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Metre long etc. with charcoal/ coke and salt as required.
229Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
230Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
231Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
232Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
233Providing and fixing 4mm dia.copper wire on surface or in recess for loop earthing as required.
234Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
235MCCB, MCB & DB"S Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
236MV CABLE LAYING Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
237MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 16 sq. mm (19mm)
2383½ X 25 sq. mm (28mm)
2393½ X 185 sq. mm (70mm)
2403½ X 300 sq. mm (70mm)
241Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 300 sq. mm
242Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in ground/partially in air (10% of cable length) including excavation of cable trench upto depth of 75cm. Refilling, protective brick covering, sand cushioning etc. complete handling of surplus soil, debries etc. to proper place as speciefied and directed by the deptt. a) 4.00 mm2 3core U.G. Cable
243b) 6.00 mm2 2core U.G. Cable
244c) 25.00 mm² 3½ core U.G. Cable
245e) 300.00 sqmm 31/2 core UG cable
246f) 6.00 Sq. mm.4 Core armoured U.G. cable
247Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in pucca flooring road crossing, drain crossing and partially in air through GI pipe (Tata/Nezone make) with necy. bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the Deptt. a) 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
248b) 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
249c) 25.00 mm² 3½ core U.G. Cable in 40mm dia medium quality G.!. Pipe
250e) 300.00 Sq.mm 3&1/2 Core U.G. cable in 100mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
251f) 66.00 Sq.mm 4 Core U.G. cable in 32mm dia medium duty G.I. pipe
252Feeder Pillar - STL Design, Manufacture, Supplying, Fixing in position,Testing & Commissioning of floor mounted Feeder Pillar including all components housed in 16 SWG cubicle type sheet steel floor mounting, outdoor type as required with dust proof, hinged and lockable doors complete with inter-connections with copper wires, taps, bonding to earth & painting in line with specification, complete with neutral, earth strips of adequate size & drawings. a) Incoming : 40 Amps 4P 25KA MCCB b) Astronomical timer switch – 1 no. c) Busbar: 100 Amps TPN Copper Busbar Outgoings: d) 16 amps DP MCB –12 nos e) 16 amps switch and socket – 1 no. f) 24" tube light with switch inside feeder pillar – 1 no.
253FLOOD / STREET LIGHTING POLE & LUMINIARIES Supplying, installation, testing and commissioning of the following of the street light luminairies of the following specification "Die Cast Aluminum housing acting as Heat Sink for reliable performance. ü Prismatic Diffuser to ensure Road Light Distribution Operating Voltage 220 – 240V /50 Hz AC ü Luminaire Efficacy of >60 lm/W ü CRI : 75 ü Ingress Protection : IP 65ü Suitable for side entry with pole diameter of 28mm to 40mm conforms to IEC598 Section 5 part 1, conforms to IEC598 Section 4 part 1, has lifetime of 50000 Hours with constant lumen output. ü Output luminaous flux of luminaire - 5700 Lumens (a) WIPRO make Cat No.LR02-102-XXX-57-XX90W LED
254Supplying including installation of the Octagonal poles shall be designed to withstand themaximumwind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflectionof the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuouslytapered with single longitudinal welding. There shall not be any circumferentialwelding of the pole shaft. The welding of the pole shaft shall be done bySubmerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The baseplate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approvedby Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezonemake) Pole Type BOP or equivalent-9030 Height 9m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- (Contd......)
255The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening:- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. :- (A/ 70, Bottom Dia.:- (A/ 155 , Sheet Thickness :- 3mm , Base Plate Dimensions :- (L x B x 260 x 260 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- (PC 250 Bolt Length:- 750, Projected Bolt Length :-125 Anchor plate thickness :- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work 2.04 cubic Meters.RCC 1:1.5 : 3 proportion 0.65 cubic metres. Steel 22.43 Kg. Shuttering 4.32 square metres. = 22.43 Kg.
256Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries.Header with top cap 300 mm long pipeof thickness 3 with arrangementto fix on pole top with 3 Nos. of bolts. iArmed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezonemake) Stiffener plate from arm of the following types :Single arm bracket 1000mm long for 3m to 10 metre. Poles.
257Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items. a) 12mm x 2mm x 15cm long 2 strip copper Bus Bar - 1 set b) 6-32 Amp "L" series DP MCB - 1 No. c) 6 amp "L" series SP MCB as outgoing - 2 Nos.
258Fabrication, supply and erection of 4.5 Mtr. Long 75mm dia MS pole with MS base plate of 300x300x10mm thickness at the bottom of the pole with fixing arrangement for post top lantern and to accomodate a junction box. The foundation is of cement concrete of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate) size 0.8 x 0.8 x .35 m with collar of size 0.4m dia x 0.5m height to accomodate the looping type cable end box including excavation and refilling etc. as required. The pole shall be painted with one coat of red oxide primer and two coats of aluminium paint.
259Supplying, installation, testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection with build in LED of the following landscape luminarie ( POST TOP ) suitable for 38mm dia post top mounting applications including connections with2.50 sq.mm 3coremultistrandP.V.C. insulated round copper cable as required and directed by the department. CROMPTON MAPLE CAT REF: CAT REF: LPTH-20-CDL. [PTL]
260Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 5 HP STAGE 14 to 50 with MCB controlled Submersible motor pump setcontrol panel.
261Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. 3 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guardmake)2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemensmake) .
262Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
263Supply, Fitting Fixing of Shock Treatment Chart
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail