| 1 | Taking out and servicing of window/split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oiland other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete allas specified and as directed . |
| 2 | M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -410/R-22 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for folowing capacity split type air conditioner complete all as specified and as directed. |
| 3 | 1.5 Ton Capacity |
| 4 | 2.0 Ton Capacity |
| 5 | S & F in replacement of following itemsfor window/ Split AC of followingcapacity: |
| 6 | Compressor forAC Capacity- 1.5 Tonfor window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh |
| 7 | Compressor forAC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh |
| 8 | Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make. |
| 9 | Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make. |
| 10 | Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make. |
| 11 | Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make. |
| 12 | Thermostatic switch suitable forwindow/split type AC 1.5/2.0 Ton capacity of existing make. |
| 13 | Fan motor with fan blade unit suitable for 1.5/2.0 Ton capacity window /split type air conditioner of existing make. |
| 14 | Condenser\"s fan motor with blade suitable for split type air conditioner |
| 15 | Electronic panel board / PCB with display of non inverted Airconditioner cap- 1.5TR/2TR . |
| 16 | Electronic panel board / PCB with display of inverted Airconditioner cap- 1.5TR/2TR . |
| 17 | Plastic water drain hose pipe, 15mm diafor spit type AC . |
| 18 | Remote control operating device for Window/Split type AC of 1.5/2.0 Ton with 02 Nos of pencil battery of existing make. |
| 19 | Pencil batteries for remote of split/window AC. |
| 20 | Copper tubes of size 4/8, 1/2 inch with aerofoam NBR rubber insulation tube . |
| 21 | Copper tubes of size 3/8,5/8, 1/4 inch with aerofoam NBR rubber insulation tube . |
| 22 | stand for outdoor unit of existing size complete all as specified and directed. |
| 23 | S & F in repair indoor unit complete of existing make and size for split AC 1.5 TRcomplete all as specified and directed by Engr-in-charge |
| 24 | S & F in repair outdoor unit complete of existing make and sizefor split AC 1.5 TRcomplete all as specified and directed. by Engr-in-charge |
| 25 | M&L for shifting of AC of any type of AC capacity 1.5/2.0 Ton complete in & out door unit including taking out brackets, pipe line and fixing insulating pipelines includingbrazing of copper tubes, testing/commissioning complete incl shifting of service connection and voltage stabilizer to the new location complete allas specified and as directed. |
| 26 | Taking out and servicing of electric driven single phase water cooler ofany capincluiding cleaning/removing all dust/mud, oiland other foreign particle with compressed air/water jetusing detergent solution or chemical solution ,leakage testing of refrigerant,storage tank leakage testing complete allas specified anddirected . |
| 27 | M&L for painting of water coolers of Cap - 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc before applying two coats of synthetic enamel paintby using spray painting technique to match with existing colourat existing location complete all as specified and directed by Engr in charge. |
| 28 | Ditto all as per Srl Item No 8 here in abovebut of Water cooler capacity 80/40 Ltrs. |
| 29 | M & Lfor flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134a at apprporiate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site forwater cooler of cap150/150 ltrs of Make : Bluestar/Usha/Voltas complete all as specified and directed by Engr in charge. |
| 30 | All as per serial item No-10 above but of Water cooler capacity 80/40 Ltrs. |
| 31 | S & F in replacement of following itemsfor water cooler of any capacity: |
| 32 | Compressor unit for water cooler 150/150 Ltrs of existing make or any othermake as specified in Appx \"B\" |
| 33 | Compressor unit for water cooler 80/40Ltrs of existing make or any other make as specified in Appx \"B\" |
| 34 | Condenser fan motor with fan blade for water cooler of anyCap of existing make or any other make apporved by GE mentioned in Appx\"B\" |
| 35 | Capacitor 25/35 MFD, ISI marked. |
| 36 | Thermostat with knob as per existing size and make. |
| 37 | Relay with overload protection assembly |
| 38 | Magnetic rubber gasket of top cover as per existing size and make |
| 39 | Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make |
| 40 | Pencil type strainer alongwith capillary tube suitable as per existing size and make. |
| 41 | Float valve PVC 15mm bore, heavy duty. |
| 42 | chromium plated brass push cock size 15 mm suitable |
| 43 | PVCflexible pipe size 40 mm dia with necessary clamping with jubli clipsfor drain water tray |
| 44 | PVC connection of size 15 mm dia 450mm long with PTMT nuts |
| 45 | Repair of storage tank leakage of water cooler of any cappacity through brazzing/welding/silicon gel filling complete all as specified and directed. |
| 46 | Taking out and servicing of electric driven single phase refrigerators and deep freezer, ofany cap,incluiding cleaning/removing all dust/mud, oiland other foreign particle with compressed air/water jetusing detergent solution or chemical solution ,leakage testing of refrigerant,freezer storage leakage testing complete allas specified and as directed . |
| 47 | M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -22/R-134a (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for Refrigerator/deep freezer of Cap - 170/190 Ltrs complete all as specified and as directed. |
| 48 | All as per serial item No. 15 here –in beforebut of capacity 265/280Ltrs |
| 49 | All as per serial item No. 15 here –in beforebut of capacity 300-400Ltrs |
| 50 | S & F in replacement of following itemsfor refrigerator/deep freezer of any capacity: |
| 51 | Compressor unit for Refrigerator of cap 165-195Ltrs of existing make or any othermake as specified in Appx \"B\" |
| 52 | Compressor unit for Refrigerator of cap 200-320Ltrs |
| 53 | Compressor unit for Refrigerator/Deep freezer of cap 200-400Ltrs |
| 54 | Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make as specified . |
| 55 | Thermostatic switch auto defrost type with knob suitable for existing refrigerator |
| 56 | Bulb inside the refrigerator suitable for existing refrigerator |
| 57 | Magnetic rubber door gasket suitable for existing refrigerator |
| 58 | Push type door switch suitable for existing refrigerator |
| 59 | Door lock with two keys suitable for existing refrigerator |
| 60 | Overload protectorsuitable for refrigerator .Make: INDFOSS/DANFOSS or equivalentmake as specified. |
| 61 | Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity |
| 62 | Electronic PCB for 260-400 Ltr refrigerator /Deep freezer |
| 63 | Taking out and servicing of desert coolerof any capacity i.e. checking ofdesert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc complete all as specified anddirected . |
| 64 | M&L for cutting of burnt winding of fan motor of size upto 450mm sweepand rewinding with super enamelled copper winding wire and replacing gun metal bush shaft. complete all as specified anddirected. |
| 65 | M&L for painting of desert cooler inner and outer surfaceusing one coat of red oxide and two coat of anti corrosive synthetic enamal paint of approved brandwith spray gun complete all as specified anddirected. |
| 66 | S & F ofFan Motor copper wound 16/18\" sweep, 3 Speed single phase 230V AC supply complete with Blade complete all as specified and directed. (Make: Khaitan /Crompton Greaves/Bajaj) |
| 67 | M & L for MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model complete all as specified and directed |
| 68 | S & F of PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler complete all as specified and directed. Make: Khaitan/Crompton Greaves/ Bajaj |
| 69 | S & F of PVC front grill of any size as per existing including nuts, bolts & washers complete all as specified and directed |
| 70 | M & L for Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted complete all as specified and directed |
| 71 | M & L for Bottom tank made out of 20 SWG GI sheet as per existing unserviceable tank complete all as specified and directed |
| 72 | M & L for Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing complete all as specified and directed. |
| 73 | S & F of Selector switchdimmer for desert cooler 1000 watt complete all as specified and directed. |
| 74 | S & F of PVC water distribution cup with PVC elbow and pipe for any size of cooler complete all as specified and directed |
| 75 | S & F of Capacitor cap- 4/6 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan |
| 76 | S & F of Piano switch 5 amps one way complete all as specified and directed. |
| 77 | S & F of 3 pin plug top 5 Amp complete all as specified and directed. |
| 78 | M & L for twin core 1.5 Sqmm copper conductor wire for internal wiringcomplete all as specified and directed. |
| 79 | S & F of Float valve PVC 15mm bore, heavy duty complete all as specified and directed. |
| 80 | S & F of PVC connection 60 cm long complete all as specified and directed. |
| 81 | M & L for Wooden chips pad of suitale size for 03 side shutters of desert cooler min 600gm in weight. |
| 82 | M & L for PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm complete all as specified and directed. . |
| 83 | S & F of 3 pin plug top 15 Amp complete all as specified and directed. . |
| 84 | S & F of brass stop cock,cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete all as specified and directed. |
| 85 | S & F ofbrass stop cock, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete all as specified and directed. |
| 86 | Supply & Fixing plywood 6mm thickduly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified and directed by Engr in Charge. |
| 87 | Supply, fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section as per site requirement and as directed by Engr-in-charge complete with two coats of synthetic enamel black paint over a coat of red oxide primer all as specified and directed by Engr in Charge. |
| 88 | S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections all as specified and directed by Engr in charge. |
| 89 | Ditto all as per Srl Item No 22 here in beforebut of 20mm bore |
| 90 | M&L for servicing of exsting servo voltage stabilizer three phase upto 10KVA capacity incl minor repair such as internal wiring,indication bulb etc incl disconeection from supply and restore electric supply after minor repair/servicing all as specified and directed by Engr-in-charge. |
| 91 | M&L for Dehydration oftransformer oilfor servo voltage stabilizer after disconnecting all connections and taking down from mounting structure or foundation and placing in a safe and dust free zone as indicated and removing the tank plate cover without damaging anyother parts and drying out the oil and pouring into the dehumidifier aparatus at site in front of Engineer-in-Charge and after dehumidification process, re-filling ofoil into the oil tank , placing at existing position after covering up with sheet cover without making any leakage by providing adequate cork sheet packing etc, testng ofoil and confirming the di-electric strength more than 30 mega Ohm complete all as specified and directed. |
| 92 | M&L for Filling up transformer oil for servo voltage stabilizerfor top up after removing oil tanks cover plate carefully without damaging any kind of parts by arranging all kind of safety measures, testing after filling up and confirming the di-electric strength not less than 60 KV Ohm as per IS Standard complete all as specified and directed. |
| 93 | Material and labour for chemical earthing complete with copper earth plate electrode of size 600mm x 600mm x 3 mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to and including copper earth strip 25 x 3 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG , Crystal salt 200KG , magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350mm above from top edge of plate and balance portion filing with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe up to top of plate, 50mmbore galvanisd iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1for chamber of internal size 300mm x300 x 300mm with 120mm thick wall and 700 mm x 700mm x 150mm thick, bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/sqm), funnel, with wire mesh, complete all as specified and directed. Note:-(i) quoted rate includes the cost of GI pipeupto 7.5 metrefor protection ofearth strip. (ii) quoted rateincludes cost of upto 7.5 metre earth lead strip. |
| 94 | S&F of following items forsingle phase voltage stabilizer cap- 3 to 5 KVA |
| 95 | Replacement of buck boost PCB for voltage connection |
| 96 | Display Unit |
| 97 | Auto Transformer |
| 98 | S&F of following items forsingle phase voltage stabilizer cap- 3 to 5 KVA |
| 99 | Replacement of ball boost PCB for voltage connection |
| 100 | Display Unit |
| 101 | Auto Transformer |
| 102 | S&F online UPS with maintenance free battery of 02X200AHcomplete connect to relay unit of control panel to uninterrupted electric supply to VCB/ office/installation incl battery terminal complete all as specified anddirected by Engr-in-charge. |
| 103 | S&F modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 25 Amps, 240 volts. Make- L&T, Havells, Legrand complete all asspecified and directed by Engr-in-charge. |
| 104 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 105 | 16 Sqmm 4 core |
| 106 | 10 Sqmm 2 core |
| 107 | M&L submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor four runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and directed. |
| 108 | M&L concealed submain wiring complete with 6 Sqmm single core multi strandred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and directed.Note: Two runs of 6 sqmm , one run of 6sqmm earth conductor and PVC conduit pipe shall be measured as one length only. |
| 109 | M&L concealed submain wiring complete with 4 Sqmm single core multi srtandred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and directed.Note: Two runs of 6 sqmm , one run of 6sqmm earth conductor and PVC conduit pipe shall be measured as one length only. |