Tender For District Heritage Museum,Malappuram,Electrical Works, Malappuram-Kerala

Department Of Museums-DOM has published Tender For District Heritage Museum,Malappuram,Electrical Works. Submission Date for this Tender is 30-03-2023. Spare Part Tenders in Malappuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

36941617
Tender For District Heritage Museum,Malappuram,Electrical Works
Open Tender
Indian
Kerala
Malappuram
30-03-2023

Tender Details

Tender For District Heritage Museum, Malappuram, Electrical Works- 1 Low Tension Control Panel Boards 2 Od373133 / 2022_2023 : Fabrication Supplyand Installation Of Cubicle Pattern Meter Board Made Out Of 1.63 Mm Crca Sheet With Threecompartment, One For Fixing 3 Phase Energy Meter With Cut Out , Neutral Link, 2Nd Compartment For Fixing , Phase Indication Lamps, Multifunctiion Meter, Control Fuses Etc, And 3Rd Compartment For Fixing 63 A Tpn Sdf , Provision For Vision Panel , Including Supply And Fixing 1 No 63 A Tpn Sdf, 3 Nos Led Phase Indication Lamps Controlled By 20 A Hrc Fuse Unit With 2 A Hrc Fuse Link, 1 No Led Multifunction Meter Rs485 Cl 0.5 Etc.The Board Shall Be Painted As Per Standards And Fixing The Same On Wall, Making Good The Surface Of Wall Colour Washing Etc As Required<Br> 3 Distribution Boards 4 2.5.5 : Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without McbS And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 8 Way ( 4 + 24 ) , Double Door 5 2.4.4 : Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 4 Way ( 4+12 ) , Double Door 6 2.3.8 : Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator2+12 Way, Double Door 7 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 8 2.10.4 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole 9 Od373174 / 2022_2023 : 40A Fp Mcb Isolator With Ip 65 Enclosure<Br> 10 Od373175 / 2022_2023 : 32A Dp 30Ma Rcbo<Br> 11 Od373176 / 2022_2023 : 63A Fp 30Ma / 100Ma Rcbo<Br> 12 2.13.2 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 13 Low Tension Cabling 14 90.12.2.1 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) 2 Core 4 Sq Mm 15 90.12.2.2 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) 2 Core 6 Sq Mm 16 90.12.2.40 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) 4 Core 10 Sq Mm 17 90.12.2.41 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) 4 Core 16 Sq Mm 18 90.12.2.42 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) 4 Core 25 Sq Mm 19 9.1.1 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm ( 19Mm ) 20 9.1.32 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) 21 9.1.33 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) 22 9.1.34 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 25 Sq. Mm ( 28Mm ) 23 Earthing 24 5.4 : Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 25 90.16.1.2 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) 26 90.16.1.3 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 27 90.16.1.4 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) 28 90.16.5.2 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) 29 90.16.5.3 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 30 90.16.5.4 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.4.00 Mm ( 8 Swg ) 31 Point Wiring 32 1.10.2 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 33 1.11 : Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 34 1.17.1 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.1 X 1.5 Sq. Mm 35 1.17.3 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 1.5 Sq.Mm 36 1.17.11 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 2.5 Sq. Mm 37 1.17.20 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 4 Sq. Mm 38 1.18.2 : Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pair 39 1.21.1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 40 1.21.2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 41 1.21.3 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.32 Mm 42 1.24.1 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 43 1.24.3 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 44 1.24.4 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 45 1.24.5 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 46 1.24.6 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Telephone Socket Outlet 47 1.24.8 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push 48 1.25 : Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 49 1.26 : Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 50 1.27.1 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 51 1.27.2 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 52 1.27.4 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) 53 1.27.5 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module ( 125Mmx125mm ) 54 1.27.6 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.12 Module ( 200Mmx150mm ) 55 1.31 : Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 56 1.33 : Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 57 1.45 : Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 58 1.47 : Supplying And Fixing Extra Down Rod Of 10 Cm Length G.I. Pipe, 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. ( Note: More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored ) 59 1.53.1 : Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable 60 1.53.2 : Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required2 Run Of Cable 61 1.53.3 : Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required3 Run Of Cable 62 1.55.1 : Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group A 63 1.56 : Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 64 Od373306 / 2022_2023 : Rj 45 Socket<Br> 65 Light Fixtures And Fans 66 Od373310 / 2022_2023 : Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required<Br> 67 90.4.6 : Conveyance, Installation, Testing And Commissioning Of Wall Mounting Fans Of All Types Using Mounting Brackets Supplied Along With The Fan. 68 90.4.8 : Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Colour Washing Etc. As Required. 69 90.4.10 : Conveyance, Installation , Testing And Commissioning Of Exhaust Fans Of Size Up To 450Mmin The Existing Opening, Fixing Necessary Anchor Bolts / Bolt And Nuts Etc., As Required Including Giving Connections With The Supplied Wire Along With The Exhaust Fan. 70 90.5.1.3 : Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650 / 1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell 71 90.10.3.15 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 32A Dp Switch With Indicator 72 Od373317 / 2022_2023 : 1200 Mm Bee ( Bldc ) Hs Ceiling Fan ( Crompton Make Energion Stylus 5 Star ) <Br> 73 Od373318 / 2022_2023 : 400 Mmhs Wall Fan ( Crompton Maketorpedo ) <Br> 74 Od373319 / 2022_2023 : 300 Mm Metal Body Exhaust Fan Reversible Type ( Crompton Maketrans Air ) <Br> 75 32 A Dp Switch With Indicator 76 Od373320 / 2022_2023 : Supply Trackfor Light2metrs. Length<Br> 77 Od373321 / 2022_2023 : Supply Of Trackfor Light1metr. Length<Br> 78 Labour.C For Errection, Testing And Commissionin 79 Od373324 / 2022_2023 : Track Light<Br> 80 Od373325 / 2022_2023 : Hanging Light<Br> 81 Miscellaneous 82 Od373327 / 2022_2023 : Dismantling Of Existing Electrical And Communication Installation, And Removing All The Garbage From The Site Including All The Sundry Expenses<Br> 83 Diesel Generator 84 Od373330 / 2022_2023 : <Br>Diesel Generator Supply Conveyance Installation Testing And Commissioning Of 30 Kva / 24 Kw Primewater Cooled Diesel Generator Set Comprisingthe Following Technical Specifications.Engine:-Cummins / Kirloskar / Cater Pillar / Greaves Engine4 Stroke, 3 Cylinder , Inline Type Arrangementdevelopingbhp 43Or Suiitable Rating @ 1500 Rpm Under Ntp With12v Electric Start Arrangement, With Silencer And Engine Protection Safeties With Solenoid And First Of Lube Oil. Diesel Engine Will Comply With Present Cpcb Norms. Alternator:- Stanford / Kirloskar / :Leroysomer / Crompton Make Self Exited And Self Regulated Screen Protected Drip Proof Alternator Rated 30Kva / 24 Kw Three Phase, 415 V , 0.8 Pf, 50 Hz 1500 Rpm.Under Normal Conditions The Voltage Regulation Will Be + / -1%.The Alternator Shall Be Of Class H Insulation And Designed And Built To Withstand Tropical Conditions And 10% Over Load At One Hour.The Alternator Should Confirm To Is 4722. Routine Tests As Per Relevant Iss Shall Be Conducted And Test Reports Shall Be Furnished At The Time Delivery.Standard Control Panel Complete With All Essentialaccessories. Base Frame With 65 Litres Capacity Fuel Tank And Provision For Lifting Hook For Convenient Lifting Of Complete Set Ie. Along With Canopy, Engine And Alternator. Acoustic Enclosure:-As Per Cpcb / Moef Norms Of 75 Db @ 1M At 75% Load Under Free Field Conditionsdocuments To Be Supplied:- Engine Manuel, Spare Parts Book, Warranty Certificate, , 1 Set Of Control Wiring Drawing, Orginal Manufatures Test Certificate Of Engine And Alternator.Fuel Consumption Test:-Check The Fuel Consumption Of Fuel In Litres / Hour.The Total Tank Capacity Also To Be Verified.Lub Oil Sump Capacity To Be Verified.Load Test:- One Hour 25% Load, One Hour 50% Load, Four Hour Rated Capacity, One Hour 10% Over Load.All Fuel / Lub Oil Expenses Will Be Borne By The Contractor At The Time Of Load Testing At Their Works.Testing And Commissioning:- The Dg Set Shall Be Tested As Per Relevant Is Standards At Factory In The Presence Of The Department Officials.Warranty:-The Dg Set Shall Be Guaranteed For Two Years From The Date Of Commissioning From Any Defects In Manufacturing.Any Of The Spares / Components Which Are Found To Be Defective During The Period Shall Be Replaced Immediately Free Of Cost. 85 Od373333 / 2022_2023 : Supply And Providing 100 Mm Dia Or Nearest Size &Apos;B Class Ms Pipe For Extending Exhaust Piping Including Providing Necessary Clamps, Fabricationworks Etc. Including Painting And Cladding As Per Standards.<Br> 86 Od373334 / 2022_2023 : Supply Conveyance Installation Testing Commissioning Of Wall Or Floor Mounting Type Cubicle Pattern 63 A 4 Pole Auto Transfer Switch ( Ats ) Complete With All Accessories Siuitable For 30 Kva Dg Set And Giving Connections Ets As Required<Br> 87 Electrical Works For Dg Set 88 9.1.33 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) 89 5.4 : Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 90 90.12.41.3 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 10 Sq Mm With Factory Made Clamp 91 90.16.1.5 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.75 Mm Copper Conductor ( 6 Swg ) 92 90.16.2.2 : Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.20 Mm Dia. G.I Pipe ( Medium Class ) 93 90.16.2.3 : Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.32 Mm Dia G.I Pipe ( Medium Class ) 94 90.16.2.4 : Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.40 Mm Dia G.I. Pipe ( Medium Class ) 95 90.16.5.5 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.4.75 Mm ( 6 Swg ) 96 Od373436 / 2022_2023 : Supplyand Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of<Br>Following Size In The Existing Rcc / Hume / Metal Pipe As Required.<Br> 97 Od373437 / 2022_2023 : Charges For Preparation Of Necessary Plan, Scheme And Other Related Papers For Submission To Electrical Inspectorate<Br> 98 Od373438 / 2022_2023 : Fee To Be Paid To Electrical Inspectorate Towards Scruitiny And Inspection ( Actual Amount Will Be Reimbursed On Production Of Orginal Documents ) <Br> 99 Civil Work 100 Od373461 / 2022_2023 : Civil Works<Br> 101 Ups And Av Equipment 102 Od373484 / 2022_2023 : Ups And Av Equipments

Key Value

Document Fees
INR 2760 /-
EMD
INR 49006.0 /-
Tender Value
INR 19.60 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail