Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-2 Aligarh, aligarh-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-2 Aligarh. Submission Date for this Tender is 27-03-2023. Soldering and Welding Machinery Tenders in aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36927983
Corrigendum : Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-2 Aligarh
Open Tender
Indian
Uttar Pradesh
aligarh
27-03-2023

Tender Details

Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-2 Aligarh-2 Supply Of 11 Mtrs. Long St Pole Is 410 Sp-55 3 Supply Of 11 Mtrs. Long Double Pole Is 410 Sp-55 4 Supply Of 8.5 Mtrs. Long Pcc Pole 5 Supply Of Stone Pad 6 Supply Of Abc Connector 7 Supply Of Suspension Clamp With Eye Hook 8 Supply Of Dead End Clamp With Eye 9 Supply Of Distritbution Box 10 Supply Of Earthing Complete For St Pole 11 Supply Of Stay Complete ( Gi Stay Rod 16X1800mm, 5 Kgs. Stay Wire 7 / 8, Stay Clamps, Bolts, Nuts & Washers ) 12 Supply Of 11 Kv Xlpe Cable Size 3*120 Sq.Mm. 13 Supply Of 33 Kv Xlpe Cable Size 3*300 Sq.Mm. 14 Supply Of Acsr Dog Conductor 15 Supply Of Heat Shrinkable Jointing Kit For 11 Kv Xlpe 3X120 Sq.Mm. Cable Outdoor Type 16 Supply Of Heat Shrinkable Jointing Kit For 33 Kv Xlpe 3X300 Sq.Mm. Cable Outdoor Type 17 Supply Of L.T. Aeirel Bunch Cable Size 3X120+1X95+1X16 Sq.Mm. 18 Supply Of 63 Kv Distribuition Transoformer 19 Supply Of 100 Kva Distribuition Transoformer 20 Supply Of 250 Kva Distribuition Transoformer 21 Supply Of 400 Kva Distribuition Transoformer 22 Supply Of 11 Kv D.O. Fuse Set 23 Supply Of 11 Kv Tpmo 24 Supply Of Al. Lugs 240Sq.Mm. 25 Supply Of 11 Kv Pin Insulator With Pin 26 Supply Of 11 Kv Disc Insulator With Fitting 27 Supply Of M.S. Top Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 28 Supply Of M.S. Dropper Channel Size 100X50x2028 Mm. 29 Supply Of M.S. Base Angle Size 75X75x6mm., 2028 Mm. Long With Clamp For T / F Base 30 Supply Of M.S. T-Off Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 31 Supply Of F-Braket With Clamp 32 Supply Of Clamps For Pole 33 Supply Danger Board With Clamp 34 Supply Of Nut, Bolts & Washer 35 Supply Of Barbed Wire 36 Supply Of L.T. Pvc Cable 3.5X150 Sq.Mm. 37 Supply Of L.T. Pvc Cable 3.5X400 Sq.Mm. 38 Supply Of L.T. Incoming Panel With Metering Equipment 39 Supply Of 33 Kv Lightening Arrestor 40 Supply Of11 Kv Type Cross Arm 41 Supply Ofnumber Plate 42 Supply Ofgaurding Angle 43 Supply Ofgi Wire 6Swg 44 Supply Ofgi Wire 8Swg 45 Erection 46 Erection Of Single Support By 11 Mtrs. St Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 47 Erection Of Single Support By 8.5 Mtrs. Pcc Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 48 Erection Of Double Pole Structure By 11 Mtrs. St Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 49 Laying Of 33 Kv Xlpe Cable 3X300 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 50 Laying Of 11 Kv Xlpe Cable 3X120 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 51 Laying Spreading, Lifting And Final Sagging Of Aerial Bunched Cable Size 3X120+1X95+1X16 Sq.Mm. Including Fixing Of All Accessories As Per Resspo Manual And As Per Direction Of Supervising Engineer, Including The Cost Of Arrangement Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. : 52 Laying Of Lt Pvc Cable 3.5X150 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 53 Laying Of Lt Pvc Cable 3.5X400 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 54 Laying Sagging Stringing And Jumpering Of Acsr Dog Conductor On The Newly Erected Pole As Per Respo Manual And As Per Direction Of Supervising Engineer, Including The Cost Of Arrangement Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. 55 Fixing & Connecting Of Earthing Rods As Per Resspo Manual Including The Cost Of Labour, T&P Etc. Required For Proper Completion Of Work. 56 Erection And Grouting Of Stay Set Including The Work Of Nozzling Etc. As Per Respo Manual And Also Including The Cost Of Arrangement Of All Grouting Material, Labour, T&P Etc. Required For Proper Completion Of Work As Per Resspo Manual. 57 Filling Of Heat Shrinkable Jointing Kit For 33 Kv Xlpe 3X300 Sq.Mm. Cable Indoor / Outdoor Type As Per Resspo Norms. 58 Filling Of Heat Shrinkable Jointing Kit For 11 Kv Xlpe 3X120 Sq.Mm. Cable Indoor / Outdoor Type As Per Resspo Norms. 59 Painting Of Double Pole Structure Of St Pole In Two Coats Of Red Oxide And Two Coats Of Silver Paint With Bottom 6 Feet By Fluorescent Paint In Strips. 60 Painting Of Single Pole Structure Of St Pole In Two Coats Of Red Oxide And Two Coats Of Silver Paint With Bottom 6 Feet By Fluorescent Paint In Strips. 61 Erection Of Pin Insulator With Pin & Nuts, 11 Kv 62 Erection Of Disc Insulator With Fittings, 11 Kv 63 Erection Of Danger Board With Nuts & Bolts And Clamps 64 Erection Of M.S. Top Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 65 Erection Of M.S. Dropper Channel Size 100X50x2028 Mm. 66 Erection Of M.S. Base Angle Size 75X75x6mm., 2028 Mm. Long With Clamp For T / F Base 67 Erection Of M.S. T-Off Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 68 Erection Of F-Braket With Clamp 69 Plinth 250, 400 Kva 70 Fancing 250, 400Kva 71 Neutral & Body Earthing Of 11 / 0.4 Kv Sub-Stations Installed By Digging Of Pit Upto Water Level Depth ( Approx. 125 Feet ) And Then Inserting 1-¼” Dia Gi Pipe Of ‘A’ Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 40X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer. It Includes The Cost Of All Material Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. The Aforesaid Work Shall Be Carried Out As Per Resspo Norms. 72 Erection Of Stone Pad 73 Erection Of Peircing Connector 74 Erection Of H.T. / L.T. Clamps With Nuts & Bolts 75 Erection Of Eye-Hook With Suspension Clamps 76 Erection Of 11 Kv Tpmo 77 Erection Of 11 Kv Do Fuse Set 78 Laying Of Barbed Wire 79 Installation Of L.T. Incoming Panel With Metering Equipment 80 Installation Of 33 Kv Lightening Arrestor 81 Fixing Of Lt Distribution Box Including Making Connections Of Distribution Box With Lt Mains By Piercing Clamps For Aerial Bunched Cable.The Work Will Also Include The Opening Of The Service Connection Of The Consumer And Its Connecting In Distribution Box. 82 Mounting Of 63 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 83 Mounting Of 100 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 84 Mounting Of 250 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 85 Mounting Of 400 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 86 After Opening Of Ht & Lt Connections, Dismantalling Of 25 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Other Placeincluding Loading & Unloading At The Respective Ends And Mounting On Double Pole / Placement On The Plinth Including Proper Jumpering From 11 Kv Tpmo To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 87 After Opening Of Ht & Lt Connections, Dismantalling Of63 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Other Placeincluding Loading & Unloading At The Respective Ends And Mounting On Double Pole / Placement On The Plinth Including Proper Jumpering From 11 Kv Tpmo To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 88 After Opening Of Ht & Lt Connections, Dismantalling Of 100, 160 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Other Placeincluding Loading & Unloading At The Respective Ends And Mounting On Double Pole Including Proper Jumpering From 11 Kv Tpmo To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 89 After Opening Of Ht & Lt Connections, Dismantalling Of 250 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Other Placeincluding Loading & Unloading At The Respective Ends And Mounting On Double Pole Including Proper Jumpering From 11 Kv Tpmo To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 90 Dismantling Ofold & Used Ms Scrap Form Existing Line And Its Safe Carriage From Site To Store As Per Resspo Norms. 91 Dismantling Ofold & Used St Poles 11 Mts. And Its Safe Carriage From Site To Store As Per Resspo Norms. 92 Dismantling Ofold & Used Abc Scrap Form Existing Line And Its Safe Carriage From Site To Store As Per Resspo Norms.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Mar-2023 NEW TENDER DOCUMENTS Other 27-03-2023
2 25-Mar-2023 Revised Tender document, plz fill revise tender document Other 27-03-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 700000.0 /-
Tender Value
INR 6.50 Crore /-

BOQ Items

Name of Work:
Sl. No. Item Description
1SUPPLY
2Supply of 11 Mtrs. Long ST Pole IS 410 SP-55
3Supply of 11 Mtrs. Long Double Pole IS 410 SP-55
4Supply of 8.5 Mtrs. Long PCC Pole
5Supply of Stone Pad
6Supply of ABC connector
7Supply of suspension clamp with eye hook
8Supply of Dead End Clamp with eye
9Supply of Distritbution Box
10Supply of Earthing Complete for ST Pole
11Supply of Stay complete (GI Stay Rod 16x1800mm, 5 Kgs. Stay wire 7/8, Stay clamps, Bolts, Nuts & Washers)
12Supply of 11 KV XLPE Cable size 3*120 Sq.mm.
13Supply of 33 KV XLPE Cable size 3*300 Sq.mm.
14Supply of ACSR Dog Conductor
15Supply of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x120 Sq.mm. Cable Outdoor Type
16Supply of Heat Shrinkable Jointing Kit for 33 KV XLPE 3x300 Sq.mm. Cable Outdoor Type
17Supply of L.T. Aeirel Bunch Cable size 3x120+1x95+1x16 sq.mm.
18Supply of 63 KV Distribuition Transoformer
19Supply of 100 KVA Distribuition Transoformer
20Supply of 250 KVA Distribuition Transoformer
21Supply of 400 KVA Distribuition Transoformer
22Supply of 11 KV D.O. Fuse Set
23Supply of 11 KV TPMO
24Supply of Al. Lugs 240Sq.mm.
25Supply of 11 KV Pin Insulator with pin
26Supply of 11 KV Disc Insulator with fitting
27Supply of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp
28Supply of M.S. Dropper Channel size 100x50x2028 mm.
29Supply of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base
30Supply of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp
31Supply of F-Braket with clamp
32Supply of Clamps for Pole
33Supply Danger Board with clamp
34Supply of Nut, Bolts & washer
35Supply of Barbed Wire
36Supply of L.T. PVC cable 3.5x150 Sq.mm.
37Supply of L.T. PVC cable 3.5x400 Sq.mm.
38Supply of L.T. Incoming Panel with metering equipment
39Supply of 33 KV Lightening Arrestor
40Supply of11 KV Type Cross Arm
41Supply ofNumber Plate
42Supply ofGaurding Angle
43Supply ofGI wire 6swg
44Supply ofGI wire 8swg
45ERECTION
46Erection of Single Support by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
47Erection of Single Support by 8.5 Mtrs. PCC pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
48Erection of Double Pole Structure by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
49Laying of 33 KV XLPE Cable 3x300 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
50Laying of 11 KV XLPE Cable 3x120 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
51Laying spreading, lifting and final sagging of Aerial Bunched Cable size 3x120+1x95+1x16 sq.mm. including fixing of all accessories as per RESSPO Manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work. :
52Laying of LT PVC Cable 3.5x150 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
53Laying of LT PVC Cable 3.5x400 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
54Laying sagging stringing and jumpering of ACSR Dog Conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work.
55Fixing & connecting of earthing rods as per RESSPO Manual including the cost of labour, T&P etc. required for proper completion of work.
56Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work as per RESSPO Manual.
57Filling of Heat Shrinkable Jointing Kit for 33 KV XLPE 3x300 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms.
58Filling of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x120 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms.
59Painting of Double Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips.
60Painting of Single Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips.
61Erection of Pin Insulator with Pin & Nuts, 11 KV
62Erection of Disc Insulator with fittings, 11 KV
63Erection of Danger board with Nuts & bolts and clamps
64Erection of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp
65Erection of M.S. Dropper Channel size 100x50x2028 mm.
66Erection of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base
67Erection of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp
68Erection of F-Braket with clamp
69Plinth 250,400 KVA
70Fancing 250, 400KVA
71Neutral & body earthing of 11/0.4 KV Sub-stations installed by digging of pit upto water level depth (approx. 125 feet) and then inserting 1-¼” dia GI pipe of ‘A’ grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 40x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer. It includes the cost of all material labour, T&P, carrier etc. required for proper completion of work. The aforesaid work shall be carried out as per RESSPO norms.
72Erection of Stone Pad
73Erection of Peircing Connector
74Erection of H.T./L.T. Clamps with Nuts & Bolts
75Erection of Eye-hook with suspension clamps
76Erection of 11 KV TPMO
77Erection of 11 KV DO Fuse Set
78Laying of Barbed wire
79Installation of L.T. Incoming Panel with metering equipment
80Installation of 33 KV Lightening Arrestor
81Fixing of LT Distribution box including making connections of distribution box with LT mains by piercing clamps for Aerial Bunched Cable.The work will also include the opening of the service connection of the consumer and its connecting in distribution box.
82Mounting of 63 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
83Mounting of 100 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
84Mounting of 250 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
85Mounting of 400 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
86After opening of HT & LT Connections, dismantalling of 25 KVA Distribution Transformer from double pole and its safe carriage from respective site to other placeincluding loading & unloading at the respective ends and mounting on double pole / placement on the Plinth including proper jumpering from 11 KV TPMO to the transformer and also connecting the LT site cables as per RESSPO Manual.
87After opening of HT & LT Connections, dismantalling of63 KVA Distribution Transformer from double pole and its safe carriage from respective site to other placeincluding loading & unloading at the respective ends and mounting on double pole / placement on the Plinth including proper jumpering from 11 KV TPMO to the transformer and also connecting the LT site cables as per RESSPO Manual.
88After opening of HT & LT Connections, dismantalling of 100, 160 KVA Distribution Transformer from double pole and its safe carriage from respective site to other placeincluding loading & unloading at the respective ends and mounting on double pole including proper jumpering from 11 KV TPMO to the transformer and also connecting the LT site cables as per RESSPO Manual.
89After opening of HT & LT Connections, dismantalling of 250 KVA Distribution Transformer from double pole and its safe carriage from respective site to other placeincluding loading & unloading at the respective ends and mounting on double pole including proper jumpering from 11 KV TPMO to the transformer and also connecting the LT site cables as per RESSPO Manual.
90Dismantling ofold & used MS Scrap form existing line and its safe carriage from site to store as per RESSPO Norms.
91Dismantling ofold & used ST Poles 11 Mts. and its safe carriage from site to store as per RESSPO Norms.
92Dismantling ofold & used ABC Scrap form existing line and its safe carriage from site to store as per RESSPO Norms.