Tender For Repair And Renovation Of Room Geology Lab In Applied Sciences Department
Tender Value
11.03 Lakhs
Estimated cost
Bid Submission
29 Mar 2023
0 days left
EMD
22071
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Renovation Of Room Geology Lab In Applied Sciences Department
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 3 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 5 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 6 | 200x10 mm |
| 7 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 8 | 125 mm |
| 9 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special sectionpowerpressed/rollformG.I.sheetwithzinccoatingof 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, includingjointing andfinishingtoaflush finishwith recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete. |
| 10 | 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 11 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 12 | Glazed vitrified floor tiles polished finish of size |
| 13 | Size of Tile600 x 1200 mm |
| 14 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 15 | Size of Tile 800x800 mm |
| 16 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 17 | Size of Tile 800x800 mm |
| 18 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 19 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 20 | 12 mm cement plaster of mix : |
| 21 | 1:6 (1 cement: 6 coarse sand) |
| 22 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
| 24 | New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 26 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 27 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 28 | In cement mortar |
| 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 30 | For fixed portion |
| 31 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 32 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 33 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 34 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 35 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 36 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 37 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter- locking metal powder coatedT-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-Trunners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- Tof size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 38 | With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 39 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 40 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 41 | Providing and fixing zebra blind in front of windows of good quality as per the requirement of site and approved by the engineer in charge |
| 42 | Providing and filling 50 mm thick rockwool of 48 kg /cum in between gypsum partition for sound proofing with appropriate SR complete in all respect as per the direction of engineer in charge. |
| 43 | Electrical Work |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 45 | Group B |
| 46 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 1No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 47 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. |
| 48 | 3 x 1.5 sq. mm |
| 49 | 3 x 2.5 sq. mm |
| 50 | 3 x 4 sq. mm |
| 51 | Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 52 | 2 Pair |
| 53 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 54 | 20 mm |
| 55 | 25 mm |
| 56 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 57 | 5/6 A switch |
| 58 | 15/16 A switch |
| 59 | 3 pin 5/6 A socket outlet |
| 60 | 6 pin 15/16 A socket outlet |
| 61 | Telephone socket outlet |
| 62 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
| 63 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 64 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
| 65 | 1 or 2 Module (75mmX75mm) |
| 66 | 3 Module (100mmX75mm) |
| 67 | 4 Module (125mmX75mm) |
| 68 | 6 Module (200mmX75mm) |
| 69 | 8 Module (125mmX125mm) |
| 70 | 12 Module (200mmX150nnm) |
| 71 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6Amodularsocketoutlet and 5/6Amodularswitch, connections etc. as required. |
| 72 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 73 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 74 | Supplyinganddrawingof UTP 4pair CAT 6LANCableinthe existing surface/ recessed Steel/ PVC conduit as required. |
| 75 | 1 run of cable |
| 76 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 77 | Group C |
| 78 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 79 | 100A,30KA,FPMCCB |
| 80 | Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 81 | 8 way (4 + 24), Double door |
| 82 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 83 | Single pole |
| 84 | Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. |
| 85 | Supply, installation , testing and commissioning of 1200mm sweep BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, clas of insulation :B, 3 nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10% remote or electronic regulator unit fo speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.) inulation resistance more than 2 mega ohm, suitable for 23 V, 50Hz, single phase AC supply, earthing etc complete as required |
| 86 | Suppply and erection of AC ceiling fans with copper winding but without regulator complete with MS blades, plastic canopies 2 nos double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps erc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5mm2 single core copper consuctor cable and 3mm thick white BL sheet cover for fan box of suitable size. The sample of fans shall be got approved from the SDE in charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge.Makes Havells-Velocity/Orient-New Breeze/Crompton-High Speed/ Usha-Strikers/Bajaj- Speedster only |
| 87 | Size 56\" (1400mm) |
| 88 | Supply ,installation, testing and commissioning of recessed type LED panel 2\"x 2\",having CRCA housing duly painted with diffuser, minimum 3600 lumens and 50000 burning hours of make Philips RC 380-B LED 36S-6500-G6/ Wipro CRCO10R036HP57MO / Havells PLUTO NEO 2X2 PLR 34W LED 857S.The job inculdes the cost of testing, commisisoning and making connection with 3*1.5 sq mm copper wire from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge. |
| 89 | Supply and erection of recessed round down lighter 12 watt 5700/6500K CDL (Cool day Light) made of pressuredia-cast aluminium, heat sink and high quality PC diffuser, in white powder coated finish with integral electronic low THD (10%) LED Driver. The fixture should have a minimum system efficancy of 110 lumens/watt with CRI > 80, surge protection-2.5 KV, life 50000 hours, desgin ambient temp 45 degree celcius. The job includes cutting of false ceiling, fixing down ligher and connection to adjacent light point complete in all respect. Make- Philips-Model Green peform sleek DH296BLED-12S-6500PSEWHS1/Panasonic-Model-ARUMI-PDLM26128/WIPRO-LD06-151-LD06-XXX-57-XX |
| 90 | Supply and erection of Modular typeDP switch 32 Amp 250 Volt along with modular box, modular base and cover plat 2 module complete in all respect.Make Legrand (Lyncus)/ABB (Tvisha/ Gold Medal(GIFA) Crabtree (Athena) |
| 91 | Supply and installation of sheet steel enclosure for TP/FPMCCB up to 100amp with neutral link on existing board/recessed in wall with all petty material and labour required to complete the job in all respect. Make Havells/ABB/L&T/Schnieder |
| 92 | Supplying & installation Split A.C. 2.0 (+/- 10%) tonne capacity 2 star rating or as per OEM with refrigent R-410A/-R-32 gas of nominal cooling capacity shall not be less than 6200 k.cal/hr with IS EER in range 3.50 -3.99& Indoor noise level not to exceed 50 dB and Copper condenser.The A.C. shall be suitable for 230 Volts (+) (-)10% valts, 50 HZ single phase & shall be capable of performing following function:- (i) Cooling (ii) Dihumidifying(iii) Air circulation (iv) Filtering. including installation charges complete in all respect to the entire satisfactionof EIC. Make Carrier/Daikin/ Hitachi/ Mitshubishi /Toshiba. |
| 93 | Providingand Fixing of Voltage Stabilizers of (3 stage) with Copper winding Input range 160 to 280 Volts, Nominal output-230 Volts±10%Including cost of copper wire from stabilizer to AC unit and power plug to stabilizer upto 6m each with M.S. body of 22 gauge sheet (powder coated), complete in all respects Make Deol or Jewel Volts, V-guard. |
| 94 | 5 KVA capacity |
| 95 | Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge. |
| 96 | Providing and Fixing of PVC Rigid drain Pipe surface/recess with reporting to the original complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾”including specials Diplast Or Equalivent. |
| 97 | Providing and Fixing of 22 gauge softcopper pipingof size 3/8” & 5/8” or as per original manufacturer of A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition.The rate per meter includes cost of 1 meter each of both 3/8” & 5/8” with insulation. Make Rajco., Mandev, Totaline. |
| 98 | Providing & fixing of 3 core2.5 sqmm flexible copper.Wire as per specifications Makes Havell, Polycabs or Finolex complete as per site |
| 99 | Supply and erection of \"D\" Hook hanger duly galavnised (Make National) size 50mmx32mm for erection of ceiling fan fixed in RCC slab with two number metal fastners 75mm long of suitable dia complete in all respect.. |
| 100 | Supplyand erection of fan rod 48\" length made of seemless MS pipe dia duly powder coated complete in all respect. Make National |
AI Tender Summary
Tender Timeline
Mar 22, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMar 29, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 29, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender