Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To Govt. Iti Garnota (Building Additional Accommodation) In Tehsil Bhatiyat By Prov. 11/.4 Kv 400 Kva S/Stn. A/W 11 Kv Ht And Lt Line Section Si, dalhousie-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To Govt. Iti Garnota (Building Additional Accommodation) In Tehsil Bhatiyat By Prov. 11/.4 Kv 400 Kva S/Stn. A/W 11 Kv Ht And Lt Line Section Si. Submission Date for this Tender is 27-03-2023. Overhead Line Tenders in dalhousie Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36919008
Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To Govt. Iti Garnota (Building Additional Accommodation) In Tehsil Bhatiyat By Prov. 11/.4 Kv 400 Kva S/Stn. A/W 11 Kv Ht And Lt Line Section Si
Open Tender
Indian
Himachal Pradesh
dalhousie
27-03-2023

Tender Details

Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To Govt. Iti Garnota ( Building Additional Accommodation ) In Tehsil Bhatiyat By Prov. 11 / .4 Kv 400 Kva S / Stn. A / W 11 Kv Ht And Lt Line Section Sihunta Unde--- 1 Supply part of 11/.4 KV 400 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 400KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 10 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with ACB (630 A, 50 KA, 4P,1 No.) & SFU (100 A 6 No. rewireble) for 400KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-185mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer 35 Prov. Transformer Bed plinth for 400KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 36 Erection part of 11/.4 KV 400 KVA DISTRIBUTION SUB STATION 37 11/.4 KV 400KVA DTR (REC Sep. ord 11/1976 38 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 39 Muff for steel tubular pole with concrete filling 40 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 41 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 42 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 43 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 44 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 45 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 46 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 47 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 48 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 51 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 52 D.O Fuse unit 53 Surge Arrester, 9 kV Station Class 54 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 55 Stay set complete 56 Staywire (7/3.15mm)( 10 Kg per stay set) 57 Pipe earthing with GI,Charcoal & Salt 58 Prov. LT distribution panel with ACB (630 A, 50 KA, 4P,1 No.) & SFU (100 A 6 No. rewireble) for 400KVA Trf. as per specification 59 Half clamp (M.S. Flat 50x6) 60 Full clamps (M.S. Flat 50x6) 61 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 62 Aluminium Thimbles 63 Copper Thimble 64 Danger Plate 65 Barbed wire (REC Sp F 3/1981) 66 LT Cable 3-1/2 core-185mm sq. 67 Alluminium Paint 68 Prov.ACSR, 6/1/3.35 mm 69 prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer 70 Prov. Transformer Bed plinth for 400KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 71 Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.200 KM) 72 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 73 Prov. Steel tubular poles. 10mtrs 74 Muff for steel tubular pole (2000mm long) with concrete filling 75 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 76 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 77 Pole Top Bracket [MSCI:100x50x6mm-100mm] 78 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 79 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 80 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 81 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 82 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 83 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 84 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 85 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 86 HT earthing set complete (REC Constr. Standared J-1) 87 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 88 Eye Hook for earth wire 89 Earth Wire Clamp 90 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 91 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 92 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 93 Danger Plate (250X200X1.6 mm) 94 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 95 Barbed wire (REC Sp F 3/1981) 96 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 97 Alluminium Paint 98 11 KV Isolator Switch (11KV, 630A, 25A w/ES) for 33 KV S/stn at Sihunta 99 Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.200KM) 100 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 101 Prov. Steel tubular poles. 10mtrs 102 Muff for steel tubular pole (2000mm long) with concrete filling 103 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 104 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 105 Pole Top Bracket [MSCI:100x50x6mm-100mm] 106 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 107 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 108 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 109 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 110 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 111 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 112 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 113 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 114 HT earthing set complete (REC Constr. Standared J-1) 115 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 116 Eye Hook for earth wire 117 Earth Wire Clamp 118 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 119 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 120 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 121 Danger Plate (250X200X1.6 mm) 122 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 123 Barbed wire (REC Sp F 3/1981) 124 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 125 Alluminium Paint 126 11 KV Isolator Switch (11KV, 630A, 25A w/ES) for 33 KV S/stn at Sihunta 127 Supply Part of CT/PT Unit 128 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 129 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 130 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 131 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 132 CT-PT Unit Belting and Knee Bracing 133 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 134 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 135 Half clamp (MS Flat 50x6 mm) 136 Full clamp (MS Flat 50x6 mm) 137 Nut & Bolts off size 138 Aluminium Thimble 139 copper Thimble 140 Erection Part of CT/PT Unit 141 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 142 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 143 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 144 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 145 CT-PT Unit Belting and Knee Bracing 146 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 147 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 148 Half clamp (MS Flat 50x6 mm) 149 Full clamp (MS Flat 50x6 mm) 150 Nut & Bolts off size 151 Aluminium Thimble 152 copper Thimble 153 Supply Part of THREE PHASE LT LINE WITH ABCON STEEL POLES(0.330KM) 154 LT AB Cable 3x120+95mm2 PVC (1.1KV, 3+1 C al.) 155 Steel Pole 9 Mtr. Long (1800mm long) 156 Muff for steel tubular pole 157 Suspension Assembly 158 Fecad hook 159 Anchoring Assembly 160 LT Saty Set CompleteREC No 31/1983 161 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 162 Prov. Full clamp 163 Coil Earthing (spec J-1/72) 164 T-Jointing Kit 165 M.S.Nuts & Bolt off Sizes 166 Aluminium paint 167 Erection Part of THREE PHASE LT LINE WITH ABCON STEEL POLES(0.330KM) 168 LT AB Cable 3x120+95mm2 PVC (1.1KV, 3+1 C al.) 169 Steel Pole 9 Mtr. Long (1800mm long) 170 Muff for steel tubular pole 171 Suspension Assembly 172 Fecad hook 173 Anchoring Assembly 174 LT Saty Set CompleteREC No 31/1983 175 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 176 Prov. Full clamp 177 Coil Earthing (spec J-1/72) 178 T-Jointing Kit 179 M.S.Nuts & Bolt off Sizes 180 Aluminium paint

Key Value

Document Fees
INR 1180 /-
EMD
INR 22006.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work: Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Govt. ITI Garnota (Building Additional Accomodation) in Tehsil Bhatiyat by Prov. 11/.4 KV 400 KVA S/Stn.a/w 11 KV HT and LT linesection Sihunta under ESD Sihunta ED Dalhousie ( T.S. No. 111/22-23 )
Sl. No. Item Description
1Supply part of 11/.4 KV 400 KVA DISTRIBUTION SUB STATION
211/.4 KV 400KVA DTR (REC Sep. ord 11/1976
3Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
4Muff for steel tubular pole with concrete filling
5X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
6MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
7X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
8X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
9X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
10MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
11MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
12MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
13MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
14MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
15G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
16G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
17D.O Fuse unit
18Surge Arrester, 9 kV Station Class
19Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
20Stay set complete
21Staywire (7/3.15mm)( 10 Kg per stay set)
22Pipe earthing with GI,Charcoal & Salt
23Prov. LT distribution panel with ACB (630 A, 50 KA, 4P,1 No.) & SFU (100 A 6 No. rewireble) for 400KVA Trf. as per specification
24Half clamp (M.S. Flat 50x6)
25Full clamps (M.S. Flat 50x6)
26M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
27Aluminium Thimbles
28Copper Thimble
29Danger Plate
30Barbed wire (REC Sp F 3/1981)
31LT Cable 3-1/2 core-185mm sq.
32Alluminium Paint
33Prov.ACSR, 6/1/3.35 mm
34prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer
35Prov. Transformer Bed plinth for 400KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
36Erection part of 11/.4 KV 400 KVA DISTRIBUTION SUB STATION
3711/.4 KV 400KVA DTR (REC Sep. ord 11/1976
38Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
39Muff for steel tubular pole with concrete filling
40X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
41MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
42X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
43X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
44X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
45MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
46MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
47MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
48MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
49MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
50G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
51G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
52D.O Fuse unit
53Surge Arrester, 9 kV Station Class
54Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
55Stay set complete
56Staywire (7/3.15mm)( 10 Kg per stay set)
57Pipe earthing with GI,Charcoal & Salt
58Prov. LT distribution panel with ACB (630 A, 50 KA, 4P,1 No.) & SFU (100 A 6 No. rewireble) for 400KVA Trf. as per specification
59Half clamp (M.S. Flat 50x6)
60Full clamps (M.S. Flat 50x6)
61M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
62Aluminium Thimbles
63Copper Thimble
64Danger Plate
65Barbed wire (REC Sp F 3/1981)
66LT Cable 3-1/2 core-185mm sq.
67Alluminium Paint
68Prov.ACSR, 6/1/3.35 mm
69prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer
70Prov. Transformer Bed plinth for 400KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
71Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.200 KM)
72ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
73Prov. Steel tubular poles. 10mtrs
74Muff for steel tubular pole (2000mm long) with concrete filling
75Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
76Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
77Pole Top Bracket [MSCI:100x50x6mm-100mm]
7811 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
79Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
80X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
81X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
82Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
8311 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
84Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
85Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
86HT earthing set complete (REC Constr. Standared J-1)
87Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
88Eye Hook for earth wire
89Earth Wire Clamp
90MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
91Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
92Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
93Danger Plate (250X200X1.6 mm)
94M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
95Barbed wire (REC Sp F 3/1981)
96G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
97Alluminium Paint
9811 KV Isolator Switch (11KV, 630A, 25A w/ES) for 33 KV S/stn at Sihunta
99Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.200KM)
100ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
101Prov. Steel tubular poles. 10mtrs
102Muff for steel tubular pole (2000mm long) with concrete filling
103Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
104Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
105Pole Top Bracket [MSCI:100x50x6mm-100mm]
10611 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
107Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
108X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
109X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
110Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
11111 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
112Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
113Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
114HT earthing set complete (REC Constr. Standared J-1)
115Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
116Eye Hook for earth wire
117Earth Wire Clamp
118MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
119Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
120Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
121Danger Plate (250X200X1.6 mm)
122M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
123Barbed wire (REC Sp F 3/1981)
124G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
125Alluminium Paint
12611 KV Isolator Switch (11KV, 630A, 25A w/ES) for 33 KV S/stn at Sihunta
127Supply Part of CT/PT Unit
128Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S.
129Prov, Energy meter (3 phase, 4 wire) HT CT type for Above
130Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing
131X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit
132CT-PT Unit Belting and Knee Bracing
133MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos.
134MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos.
135Half clamp (MS Flat 50x6 mm)
136Full clamp (MS Flat 50x6 mm)
137Nut & Bolts off size
138Aluminium Thimble
139copper Thimble
140Erection Part of CT/PT Unit
141Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S.
142Prov, Energy meter (3 phase, 4 wire) HT CT type for Above
143Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing
144X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit
145CT-PT Unit Belting and Knee Bracing
146MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos.
147MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos.
148Half clamp (MS Flat 50x6 mm)
149Full clamp (MS Flat 50x6 mm)
150Nut & Bolts off size
151Aluminium Thimble
152copper Thimble
153Supply Part of THREE PHASE LT LINE WITH ABCON STEEL POLES(0.330KM)
154LT AB Cable 3x120+95mm2 PVC (1.1KV, 3+1 C al.)
155Steel Pole 9 Mtr. Long (1800mm long)
156Muff for steel tubular pole
157Suspension Assembly
158Fecad hook
159Anchoring Assembly
160LT Saty Set CompleteREC No 31/1983
161Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
162Prov. Full clamp
163Coil Earthing (spec J-1/72)
164T-Jointing Kit
165M.S.Nuts & Bolt off Sizes
166Aluminium paint
167Erection Part of THREE PHASE LT LINE WITH ABCON STEEL POLES(0.330KM)
168LT AB Cable 3x120+95mm2 PVC (1.1KV, 3+1 C al.)
169Steel Pole 9 Mtr. Long (1800mm long)
170Muff for steel tubular pole
171Suspension Assembly
172Fecad hook
173Anchoring Assembly
174LT Saty Set CompleteREC No 31/1983
175Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
176Prov. Full clamp
177Coil Earthing (spec J-1/72)
178T-Jointing Kit
179M.S.Nuts & Bolt off Sizes
180Aluminium paint
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.