Power Government Departments Closing in 0 days TDR #36918991

Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To D.R.D.A. For Fish Feed Unit At Maredi By Prov. 11/.4 Kv 25 Kva S/Stn. A/W 11 Kv Ht Line Section Maredi Under Esd Chamba-Ii Ed Chamba

Issued by Government Departments · dalhousie, Himachal Pradesh
Tender Value
5.07 Lakhs
Estimated cost
Bid Submission
27 Mar 2023
0 days left
EMD
5072
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dalhousie → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To D.R.D.A. For Fish Feed Unit At Maredi By Prov. 11 / .4 Kv 25 Kva S / Stn. A / W 11 Kv Ht Line Section Maredi Under Esd Chamba-Ii Ed Chamba--- 1 Supply part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 25KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 10 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-185mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 35 Erection part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION 36 11/.4 KV 25KVA DTR (REC Sep. ord 11/1976 37 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 38 Muff for steel tubular pole with concrete filling 39 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 40 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 41 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 42 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 43 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 44 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 45 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 46 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 47 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 48 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 51 D.O Fuse unit 52 Surge Arrester, 9 kV Station Class 53 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 54 Stay set complete 55 Staywire (7/3.15mm)( 10 Kg per stay set) 56 Pipe earthing with GI,Charcoal & Salt 57 Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification 58 Half clamp (M.S. Flat 50x6) 59 Full clamps (M.S. Flat 50x6) 60 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed wire (REC Sp F 3/1981) 65 LT Cable 3-1/2 core-185mm sq. 66 Alluminium Paint 67 Prov.ACSR, 6/1/3.35 mm 68 Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 69 Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES 0.150 KM) 70 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 71 Prov. Steel tubular poles. 9mtrs 72 Prov. Steel tubular poles. 8mtrs 73 Muff for steel tubular pole (2000mm long) with concrete filling 74 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 75 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 76 Pole Top Bracket [MSCI:100x50x6mm-100mm] 77 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 78 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 79 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 80 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 81 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 82 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 83 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 84 Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set) 85 HT earthing set complete (REC Constr. Standared J-1) 86 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 87 Eye Hook for earth wire 88 Earth Wire Clamp 89 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 90 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 91 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 92 Danger Plate (250X200X1.6 mm) 93 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 94 Barbed wire (REC Sp F 3/1981) 95 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 96 Alluminium Paint 97 Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.150 KM) 98 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 99 Prov. Steel tubular poles. 9mtrs 100 Prov. Steel tubular poles. 8mtrs 101 Muff for steel tubular pole (2000mm long) with concrete filling 102 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 103 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 104 Pole Top Bracket [MSCI:100x50x6mm-100mm] 105 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 106 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 107 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 108 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 109 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 110 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 111 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 112 Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set) 113 HT earthing set complete (REC Constr. Standared J-1) 114 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 115 Eye Hook for earth wire 116 Earth Wire Clamp 117 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 118 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 119 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 120 Danger Plate (250X200X1.6 mm) 121 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 122 Barbed wire (REC Sp F 3/1981) 123 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 124 Alluminium Paint

BOQ

Name of Work:Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to D.R.D.A. for fish feed unit at Marediby Prov. 11/.4 KV 25 KVA S/Stn.a/w 11 KV HTlinesection Maredi under ESD Chamba-II ED Chamba ( T.S. No. 130/22-23 )
Sl. No. Item Description
1Supply part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION
211/.4 KV 25KVA DTR (REC Sep. ord 11/1976
3Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
4Muff for steel tubular pole with concrete filling
5X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
6MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA\"s )
7X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
8X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
9X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
10MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
11MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
12MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
13MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
14MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
15G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
16G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
17D.O Fuse unit
18Surge Arrester, 9 kV Station Class
19Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
20Stay set complete
21Staywire (7/3.15mm)( 10 Kg per stay set)
22Pipe earthing with GI,Charcoal & Salt
23Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification
24Half clamp (M.S. Flat 50x6)
25Full clamps (M.S. Flat 50x6)
26M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
27Aluminium Thimbles
28Copper Thimble
29Danger Plate
30Barbed wire (REC Sp F 3/1981)
31LT Cable 3-1/2 core-185mm sq.
32Alluminium Paint
33Prov.ACSR, 6/1/3.35 mm
34Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
35Erection part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION
3611/.4 KV 25KVA DTR (REC Sep. ord 11/1976
37Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
38Muff for steel tubular pole with concrete filling
39X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
40MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA\"s )
41X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
42X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
43X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
44MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
45MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
46MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
47MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
48MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
49G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
50G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
51D.O Fuse unit
52Surge Arrester, 9 kV Station Class
53Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
54Stay set complete
55Staywire (7/3.15mm)( 10 Kg per stay set)
56Pipe earthing with GI,Charcoal & Salt
57Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification
58Half clamp (M.S. Flat 50x6)
59Full clamps (M.S. Flat 50x6)
60M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
61Aluminium Thimbles
62Copper Thimble
63Danger Plate
64Barbed wire (REC Sp F 3/1981)
65LT Cable 3-1/2 core-185mm sq.
66Alluminium Paint
67Prov.ACSR, 6/1/3.35 mm
68Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
69Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES 0.150 KM)
70ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
71Prov. Steel tubular poles. 9mtrs
72Prov. Steel tubular poles. 8mtrs
73Muff for steel tubular pole (2000mm long) with concrete filling
74Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
75Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
76Pole Top Bracket [MSCI:100x50x6mm-100mm]
7711 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
78Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
79X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
80X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
81Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
8211 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
83Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
84Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set)
85HT earthing set complete (REC Constr. Standared J-1)
86Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
87Eye Hook for earth wire
88Earth Wire Clamp
89MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
90Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
91Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
92Danger Plate (250X200X1.6 mm)
93M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
94Barbed wire (REC Sp F 3/1981)
95G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
96Alluminium Paint
97Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.150 KM)
98ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
99Prov. Steel tubular poles. 9mtrs
100Prov. Steel tubular poles. 8mtrs
101Muff for steel tubular pole (2000mm long) with concrete filling
102Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
103Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
104Pole Top Bracket [MSCI:100x50x6mm-100mm]
10511 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
106Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
107X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
108X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
109Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
11011 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
111Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
112Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set)
113HT earthing set complete (REC Constr. Standared J-1)
114Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
115Eye Hook for earth wire
116Earth Wire Clamp
117MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
118Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
119Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
120Danger Plate (250X200X1.6 mm)
121M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
122Barbed wire (REC Sp F 3/1981)
123G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
124Alluminium Paint

AI Tender Summary

OUR REF NO 36918991
AUTHORITY Government Departments
TENDER VALUE 5.07 Lakhs
LAST DATE 27-03-2023
Authority
Authority Name Himachal Pradesh State Electricity Board
Work Description Tender For Supply Of Equipment / Material , Design, Erection, Testing Commissioning For Sop To D.R.D.A. For Fish Feed Unit At Maredi By Prov. 11 / .4 Kv 25 Kva S / Stn. A / W 11 Kv Ht Line Section Maredi Under Esd Chamba-Ii Ed Chamba--- 1 Supply part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 25KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 10 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-185mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 35 Erection part of 11/.4 KV 25 KVA DISTRIBUTION SUB STATION 36 11/.4 KV 25KVA DTR (REC Sep. ord 11/1976 37 Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs 38 Muff for steel tubular pole with concrete filling 39 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 40 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 41 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 42 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 43 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 44 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 45 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 46 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 47 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 48 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 51 D.O Fuse unit 52 Surge Arrester, 9 kV Station Class 53 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 54 Stay set complete 55 Staywire (7/3.15mm)( 10 Kg per stay set) 56 Pipe earthing with GI,Charcoal & Salt 57 Prov. LT distribution panel with MCCB (10 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification 58 Half clamp (M.S. Flat 50x6) 59 Full clamps (M.S. Flat 50x6) 60 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed wire (REC Sp F 3/1981) 65 LT Cable 3-1/2 core-185mm sq. 66 Alluminium Paint 67 Prov.ACSR, 6/1/3.35 mm 68 Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 69 Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES 0.150 KM) 70 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 71 Prov. Steel tubular poles. 9mtrs 72 Prov. Steel tubular poles. 8mtrs 73 Muff for steel tubular pole (2000mm long) with concrete filling 74 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 75 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 76 Pole Top Bracket [MSCI:100x50x6mm-100mm] 77 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 78 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 79 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 80 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 81 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 82 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 83 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 84 Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set) 85 HT earthing set complete (REC Constr. Standared J-1) 86 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 87 Eye Hook for earth wire 88 Earth Wire Clamp 89 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 90 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 91 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 92 Danger Plate (250X200X1.6 mm) 93 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 94 Barbed wire (REC Sp F 3/1981) 95 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 96 Alluminium Paint 97 Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.150 KM) 98 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 99 Prov. Steel tubular poles. 9mtrs 100 Prov. Steel tubular poles. 8mtrs 101 Muff for steel tubular pole (2000mm long) with concrete filling 102 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 103 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 104 Pole Top Bracket [MSCI:100x50x6mm-100mm] 105 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 106 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 107 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 108 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 109 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 110 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 111 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 112 Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set) 113 HT earthing set complete (REC Constr. Standared J-1) 114 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 115 Eye Hook for earth wire 116 Earth Wire Clamp 117 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 118 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 119 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 120 Danger Plate (250X200X1.6 mm) 121 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 122 Barbed wire (REC Sp F 3/1981) 123 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 124 Alluminium Paint
Basic Detail
Tender No OCD/DB/Bid-57/2022-23
Bidding Type Tender
Location
City dalhousie
State Himachal Pradesh
Key Dates
Publish Date 21 Mar 2023
Submission Date 27 Mar 2023
Open Date 28 Mar 2023
Finance
Tender Value 5.07 Lakhs
Tender Fee 590
EMD 5072
Exemption Not Available
Document List
c7cca1da-b014-446b-a887-99509e3613af.html
Biddoc57.rar
BOQ_107385.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 21, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 27, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 28, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c7cca1da-b014-446b-a887-99509e3613af.html

rar

Biddoc57.rar

xls

BOQ_107385.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender