Tender For Supply Of Equipment / Material , Design, Erection, Testing , Commissioning For Sop To Hrtc Chamba For Proposed Newly Constructed Building Of Bus Stand At Bhanjraru By Prov. 11/.4 Kv 250 Kva S/Stn. At Bhanjraru Bus Stand A/W 11 K, dalhousie-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Of Equipment / Material , Design, Erection, Testing , Commissioning For Sop To Hrtc Chamba For Proposed Newly Constructed Building Of Bus Stand At Bhanjraru By Prov. 11/.4 Kv 250 Kva S/Stn. At Bhanjraru Bus Stand A/W 11 K. Submission Date for this Tender is 27-03-2023. Overhead Line Tenders in dalhousie Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36918977
Tender For Supply Of Equipment / Material , Design, Erection, Testing , Commissioning For Sop To Hrtc Chamba For Proposed Newly Constructed Building Of Bus Stand At Bhanjraru By Prov. 11/.4 Kv 250 Kva S/Stn. At Bhanjraru Bus Stand A/W 11 K
Open Tender
Indian
Himachal Pradesh
dalhousie
27-03-2023

Tender Details

Tender For Supply Of Equipment / Material , Design, Erection, Testing , Commissioning For Sop To Hrtc Chamba For Proposed Newly Constructed Building Of Bus Stand At Bhanjraru By Prov. 11/.4 Kv 250 Kva S/Stn. At Bhanjraru Bus Stand A/W 11 Kv Ht And Lt-- 1 Supply part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 250KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 10 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-185mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer 35 Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 36 Erection part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION 37 11/.4 KV 250KVA DTR (REC Sep. ord 11/1976 38 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 39 Muff for steel tubular pole with concrete filling 40 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 41 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 42 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 43 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 44 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 45 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 46 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 47 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 48 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 51 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 52 D.O Fuse unit 53 Surge Arrester, 9 kV Station Class 54 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 55 Stay set complete 56 Staywire (7/3.15mm)( 10 Kg per stay set) 57 Pipe earthing with GI,Charcoal & Salt 58 Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification 59 Half clamp (M.S. Flat 50x6) 60 Full clamps (M.S. Flat 50x6) 61 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 62 Aluminium Thimbles 63 Copper Thimble 64 Danger Plate 65 Barbed wire (REC Sp F 3/1981) 66 LT Cable 3-1/2 core-185mm sq. 67 Alluminium Paint 68 Prov.ACSR, 6/1/3.35 mm 69 prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer 70 Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 71 Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.370 KM) 72 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 73 Prov. Steel tubular poles. 9mtrs 74 Muff for steel tubular pole (2000mm long) with concrete filling 75 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 76 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 77 Pole Top Bracket [MSCI:100x50x6mm-100mm] 78 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 79 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 80 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 81 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 82 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 83 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 84 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 85 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 86 HT earthing set complete (REC Constr. Standared J-1) 87 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 88 Eye Hook for earth wire 89 Earth Wire Clamp 90 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 91 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 92 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 93 Danger Plate (250X200X1.6 mm) 94 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 95 Barbed wire (REC Sp F 3/1981) 96 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 97 Alluminium Paint 98 Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.370 KM) 99 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 100 Prov. Steel tubular poles. 9mtrs 101 Muff for steel tubular pole (2000mm long) with concrete filling 102 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 103 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 104 Pole Top Bracket [MSCI:100x50x6mm-100mm] 105 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 106 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 107 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 108 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 109 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 110 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 111 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 112 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 113 HT earthing set complete (REC Constr. Standared J-1) 114 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 115 Eye Hook for earth wire 116 Earth Wire Clamp 117 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 118 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 119 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 120 Danger Plate (250X200X1.6 mm) 121 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 122 Barbed wire (REC Sp F 3/1981) 123 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 124 Alluminium Paint 125 Supply Part of CT/PT Unit 126 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 127 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 128 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 129 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 130 CT-PT Unit Belting and Knee Bracing 131 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 132 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 133 Half clamp (MS Flat 50x6 mm) 134 Full clamp (MS Flat 50x6 mm) 135 Nut & Bolts off size 136 Aluminium Thimble 137 copper Thimble 138 Erection Part of CT/PT Unit 139 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 140 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 141 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 142 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 143 CT-PT Unit Belting and Knee Bracing 144 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 145 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 146 Half clamp (MS Flat 50x6 mm) 147 Full clamp (MS Flat 50x6 mm) 148 Nut & Bolts off size 149 Aluminium Thimble 150 copper Thimble 151 Supply Part of THREE PHASE LT LINE WITH ACSR 6/1/2.59 mm sq. ON STEEL POLES(0.390KM) 152 ACSR 6/1/2.59 mm sq. 153 Steel Pole 9 Mtr. Long (1800mm long) 154 Prov. Steel tubular poles. 2mtrs 155 Muff for steel tubular pole 156 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 157 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 158 Earth Knob 159 LT Saty Set CompleteREC No 31/1983 160 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 161 Prov. Full clamp 162 Coil Earthing (spec J-1/72) 163 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 164 Spool Tie 165 M.S.Nuts & Bolt off Sizes 166 A.I. 75x75x6mm (Length 1.5+0.2Mtr.) 167 Aluminium paint 168 Erection Part of THREE PHASE LT LINE WITH ACSR 6/1/2.59 mm sq. ON STEEL POLES(0.390KM) 169 ACSR 6/1/2.59 mm sq. 170 Steel Pole 9 Mtr. Long (1800mm long) 171 Prov. Steel tubular poles. 2mtrs 172 Muff for steel tubular pole 173 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 174 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 175 Earth Knob 176 LT Saty Set CompleteREC No 31/1983 177 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 178 Prov. Full clamp 179 Coil Earthing (spec J-1/72) 180 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 181 Spool Tie 182 M.S.Nuts & Bolt off Sizes 183 A.I. 75x75x6mm (Length 1.5+0.2Mtr.) 184 Aluminium paint

Key Value

Document Fees
INR 590 /-
EMD
INR 15204.0 /-
Tender Value
INR 15.20 Lakhs /-

BOQ Items

Name of Work: Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to HRTC Chamba for proposed Newly constructed building of Bus Stand at Bhanjraru by Prov. 11/.4 KV 250 KVA S/Stn. at Bhanjraru Bus stand a/w 11 KV HT and LT linesection Tissa-1stunder ESD Tissa ED Chamba ( T.S. No. 141/22-23 )
Sl. No. Item Description
1Supply part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION
211/.4 KV 250KVA DTR (REC Sep. ord 11/1976
3Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs
4Muff for steel tubular pole with concrete filling
5X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
6MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
7X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
8X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
9X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
10MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
11MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
12MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
13MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
14MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
15G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
16G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
17D.O Fuse unit
18Surge Arrester, 9 kV Station Class
19Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
20Stay set complete
21Staywire (7/3.15mm)( 10 Kg per stay set)
22Pipe earthing with GI,Charcoal & Salt
23Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification
24Half clamp (M.S. Flat 50x6)
25Full clamps (M.S. Flat 50x6)
26M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
27Aluminium Thimbles
28Copper Thimble
29Danger Plate
30Barbed wire (REC Sp F 3/1981)
31LT Cable 3-1/2 core-185mm sq.
32Alluminium Paint
33Prov.ACSR, 6/1/3.35 mm
34prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer
35Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
36Erection part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION
3711/.4 KV 250KVA DTR (REC Sep. ord 11/1976
38Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs
39Muff for steel tubular pole with concrete filling
40X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
41MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
42X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
43X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
44X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
45MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
46MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
47MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
48MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
49MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
50G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
51G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
52D.O Fuse unit
53Surge Arrester, 9 kV Station Class
54Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
55Stay set complete
56Staywire (7/3.15mm)( 10 Kg per stay set)
57Pipe earthing with GI,Charcoal & Salt
58Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification
59Half clamp (M.S. Flat 50x6)
60Full clamps (M.S. Flat 50x6)
61M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
62Aluminium Thimbles
63Copper Thimble
64Danger Plate
65Barbed wire (REC Sp F 3/1981)
66LT Cable 3-1/2 core-185mm sq.
67Alluminium Paint
68Prov.ACSR, 6/1/3.35 mm
69prov. HP make AIQ Desktop Model HP 200 G4 with intell core 3-10110U-10 Gen.processor, 8GB DDR4 RAM expenditure upto 16 GB, ITB, HDO (T2QORPM)2st antiglare LED desplay withFHD (1920x1060) integrated HD Graphics & Webcam, 2xUSB, 3.0 2xUSB, 2.0 Cardreacer. Audio part VGNHDMI/DP Port, 10x100, 1000Mcomdliant LAN USB key board & mouse internalspl. connectivity BO2 11 b/g/n/ac PL windows etc. with three years on site warranty. (II) 650VA offline UPS system with12Vx7AHx2Nos: 158VAH/SMF batteryto povide20 Min. battery back upwith three year warrantyon UPS &battery from delivery with printer
70Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
71Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.370 KM)
72ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
73Prov. Steel tubular poles. 9mtrs
74Muff for steel tubular pole (2000mm long) with concrete filling
75Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
76Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
77Pole Top Bracket [MSCI:100x50x6mm-100mm]
7811 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
79Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
80X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
81X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
82Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
8311 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
84Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
85Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
86HT earthing set complete (REC Constr. Standared J-1)
87Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
88Eye Hook for earth wire
89Earth Wire Clamp
90MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
91Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
92Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
93Danger Plate (250X200X1.6 mm)
94M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
95Barbed wire (REC Sp F 3/1981)
96G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
97Alluminium Paint
98Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.370 KM)
99ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
100Prov. Steel tubular poles. 9mtrs
101Muff for steel tubular pole (2000mm long) with concrete filling
102Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
103Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
104Pole Top Bracket [MSCI:100x50x6mm-100mm]
10511 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
106Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
107X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
108X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
109Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
11011 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
111Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
112Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
113HT earthing set complete (REC Constr. Standared J-1)
114Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
115Eye Hook for earth wire
116Earth Wire Clamp
117MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
118Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
119Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
120Danger Plate (250X200X1.6 mm)
121M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
122Barbed wire (REC Sp F 3/1981)
123G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
124Alluminium Paint
125Supply Part of CT/PT Unit
126Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S.
127Prov, Energy meter (3 phase, 4 wire) HT CT type for Above
128Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing
129X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit
130CT-PT Unit Belting and Knee Bracing
131MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos.
132MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos.
133Half clamp (MS Flat 50x6 mm)
134Full clamp (MS Flat 50x6 mm)
135Nut & Bolts off size
136Aluminium Thimble
137copper Thimble
138Erection Part of CT/PT Unit
139Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S.
140Prov, Energy meter (3 phase, 4 wire) HT CT type for Above
141Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing
142X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit
143CT-PT Unit Belting and Knee Bracing
144MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos.
145MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos.
146Half clamp (MS Flat 50x6 mm)
147Full clamp (MS Flat 50x6 mm)
148Nut & Bolts off size
149Aluminium Thimble
150copper Thimble
151Supply Part of THREE PHASE LT LINE WITH ACSR 6/1/2.59 mm sq. ON STEEL POLES(0.390KM)
152ACSR 6/1/2.59 mm sq.
153Steel Pole 9 Mtr. Long (1800mm long)
154Prov. Steel tubular poles. 2mtrs
155Muff for steel tubular pole
156Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977)
157D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975)
158Earth Knob
159LT Saty Set CompleteREC No 31/1983
160Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
161Prov. Full clamp
162Coil Earthing (spec J-1/72)
163G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable
164Spool Tie
165M.S.Nuts & Bolt off Sizes
166A.I. 75x75x6mm (Length 1.5+0.2Mtr.)
167Aluminium paint
168Erection Part of THREE PHASE LT LINE WITH ACSR 6/1/2.59 mm sq. ON STEEL POLES(0.390KM)
169ACSR 6/1/2.59 mm sq.
170Steel Pole 9 Mtr. Long (1800mm long)
171Prov. Steel tubular poles. 2mtrs
172Muff for steel tubular pole
173Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977)
174D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975)
175Earth Knob
176LT Saty Set CompleteREC No 31/1983
177Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
178Prov. Full clamp
179Coil Earthing (spec J-1/72)
180G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable
181Spool Tie
182M.S.Nuts & Bolt off Sizes
183A.I. 75x75x6mm (Length 1.5+0.2Mtr.)
184Aluminium paint
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail