Public Administrative Department Local Bodies Closing in 0 days TDR #36913620

Tender For Improvements Of Water Supply Scheme To Uthamapalayam Town Panchayat, Theni District Under Amrut 2.0 Scheme

Issued by Local Bodies · uthamapalayam, Tamil Nadu
Tender Value
28.28 Crore
Estimated cost
Bid Submission
12 Apr 2023
0 days left
EMD
28.28 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
uthamapalayam → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Improvements Of Water Supply Scheme To Uthamapalayam Town Panchayat, Theni District Under Amrut 2.0 Scheme

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Apr-2023 Change of Bid Document Technical Bid 12-Apr-2023

BOQ

Name of Work: Improvements of Water Supply Scheme toUthamapalayamTown Panchayat, Theni District under AMRUT 2.0 Scheme
Sl. No. Item Description
11. Earthwork excavating and depositing on bank with an initial lead of 10m & initial lift of 2m in sand silt other loose soil, wet sand or silt not water,Light black cotton soil, sandy loam, hard stiff clay, stiff black cotton, hard red earth shales, muram, graverl stoney earth & earth mixed with small size boulders & hard gravelly soil as perS.S 20B
2Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in Soft disintegrated rock, Laterite, Soft rock or Kankar, not requiring blasting etc.
32m-4m depth
44m-6m depth
5Cutting Open roads
6Labour for cutting open road for laying water mains or sewer
7i) B.T. Roads (or) Maccadam road
8ii) Concrete Roads
9Earth work excavation for water supply work- Ordinary Soil - such as Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small boulders and hard gravelly soil etc.,
10110 mm HDPE PN 10
11160 mm HDPE PN 10
12200 mm HDPE PN 10
13250 mm DI K7
14350 mm DI K7
15400 mm DI K7
16HDPE Pipes of 90 mm diameter
17HDPE Pipes of 110 mm diameter
18HDPE Pipes of 140 mm diameter
19HDPE Pipes of 160 mm diameter
20HDPE Pipes of 180 mm diameter
21HDPE Pipes of 200 mm diameter
22HDPE Pipes of 250 mm diameter
23DI K9 Pipes of 400 mm diameter
24Plain Cement Concrete 1:4:8 Mix (one part cement, four part sand and Eight part of aggrigate) using 40 mm size ISS HBG metal from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing. Laying and curing etc., complete as per TNDSS NO : 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge.
25Plain Cement Concrete 1:2:4 Mix (one part cement, two part sand and four part of aggrigate) using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour
269. Provding and laying in position, Standardised concrete Mix M-25 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite water cement ratio of 0.50, including admixture (plasticiser/ super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricatingcharges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, during, etc. complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements os IS Standards (No separate payment will be made by the Department for the excess usage of materials).
271.5 m to 4.5 m below G.L
28UPTO G.L
29Above G.L upto 4.50m height
30Above 4.50m to 7.32m ht., from G.L
31Above 7.32m to 10.98m ht., from G.L
32Above 10.98m to 14.64 ht., from G.L
33Above 14.64m to 18.30 ht., from G.L
3414. Providing and laying in position Standardised concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ration of 0.45, including admixture (plasticiser/ super plasticiser) in recommended proportins as per IS:9103 to acceierate, retard setting of concrete, improve workanility without impairing strength and durability with about (5.0cu.m) 7730kg of 20mm machine crushed stone jelly and with about (3.3 cum ) 5156kg of 10-12 mm machine crushed stone jelly and with about (4.79 cu.m) 7670kg of sent, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering fixtures lide fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate Payment will be made by the Department for the excess usage of materials)
351.5 m to 4.5 m below G.L
360-1.5m Below GL
370 to 4.5m above GL
384.50m - 7.32m
397.32m - 10.98m
4010.98m - 14.64m
4114.64m - 18.30m
4218.30m - 21.96m
4315. Provding and laying in position, Standardised concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite water cement ratio of 0.55, including admixture (plasticiser/ super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricatingcharges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, during, etc. complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements os IS Standards (No separate payment will be made by the Department for the excess usage of materials).
44Centering for sides and soffits of R.C.C slab of plane surfacefor R.C.C floor slab including strutting upto 3.3 mt height using MS sheets of size 90cmx60cm and stiffend with welded MS angle of size 25mmx25mmx3mm laid over silver oak (country wood) joist
45Plane Surface
460-3.30 M
473.30 - 4.30M above GL
484.3M to 5.30m above GL
495.30m- 6.30m above GL
506.30m- 7.30m above GL
517.30m- 8.30m above GL
529.30m -10.30 above GL
5310.30 - 11.30M above GL
5411.30 - 12.30M above GL
5514.30 - 15.30M above GL
5615.30 - 16.30M above GL
57Square Column
580-3.30 M
593.30 - 4.30M above GL
604.30 - 5.30M above GL
615.30 - 6.30M above GL
626.30 - 7.30M above GL
637.30 - 8.30M above GL
648.30 - 9.30M above GL
659.30 - 10.30M above GL
6610.30 - 11.30M above GL
6711.30 - 12.30M above GL
6812.30 - 13.30M above GL
6913.30 - 14.30M above GL
7014.30 - 15.30M above GL
7115.30 - 16.30M above GL
72Curved Surface
730-3.3m
743.30 - 4.30 m
754.30m - 5.30m
765.30m- 6.30m
776.30m - 7.30m
787.30m - 8.30m
798.30m - 9.30m
809.30m - 10.30m
8114.30m - 15.30m
8215.30m - 16.30m
8316.30m - 17.30m
84Circular Column
850-3.30 M
863.30 - 4.30M above GL
874.30 - 5.30M above GL
885.30 - 6.30M above GL
896.30 - 7.30M above GL
907.30 - 8.30M above GL
918.30 - 9.30M above GL
929.30 - 10.30M above GL
9310.30 - 11.30M above GL
9411.30 - 12.30M above GL
9512.30 - 13.30M above GL
9613.30 - 14.30M above GL
9714.30 - 15.30M above GL
9815.30 - 16.30M above GL
99Brick Work
100Brick Work in Cement Mortar 1:5 Mix (one cement, five sand) using new best II Class Ground Mould chamber Bricks of size ( 9” x 4 3/8” x 23/4 “ )from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.
101First Floor
102SecondFloor
103Plastering
104Plastering with CM 1:5(one cement and three sand) 20mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed byDepartmental Officers
105Plastering with CM 1:3(one cement and three sand) 10mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed byDepartmental Officers
106B) Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications.
107Painting
108Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specificationsfor 10 sqm
109Painting Two Coats on new Iron works with best synthetic enamel paint of approved colour and quality – 10m2.
110Steel Reinforcement
111Supplying fabricating and placing in position of RTS road at all heights for reinforcement including cost of steel for all works and labour charges including cost of binding wire etc., complete for all RCC works and as directed byDepartmental Officers
112Supply and fixing of M.S Grill Gate with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
113Rolling Shutter
114Supply and fixing of Rolling shutter of Size 2.5m *2.5m Manually operated with necessary appliances and as directed by Departmental Officers
115Window
116Supply and Delivery Fabrication of MS doors and windows with outer frame andshutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gaugeincluding ventilating arrangements using20mm square MS rods with lockingarrangements including two coats ofapproved enamel paint over coat of redoxide including cost of angles, plates,sheets, fabrication charges, cost of holdfast and transportation charges etc.,complete.
117Ventilator
118Supply and Fixing of Steel galzed ventilators of the N type of Size 0.45 m x 0.60 m fabricated with 35*20*4.0m Ms Flats wherever necessary includings all fixtures and appliances as per Standard Specification and as directed by departmental officers
119MS ladder 12m Stagging height
120Manhole
121Supplying and fixing in position C.I. Manhole covers (light or heavy duty) of 600mm X 600mm sizes of best approved quality and as per standard specifications etc., complete.
122CI Steps
123Provision for CI Steps to be placed in Staggered manner including fixing etc complete and as directed by departemental officers
124Crane
1252T capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 Mtrs.including gear type chain pulley block with GI chain and geared Travelling trolley complete with allac
126Lock & key
127Provision for Shell with lock and Key arrangements to Keep the log Book Tools etc and as directed by Departmental officers
128RCC Inside Ladder
129Providing and fixing of RCC inner ladder in RCC 1:1.5:3 (one cement, one and half sand, three aggregates) using 20mm HBG stones for OHT including grill in position, centering, shuttering charges, mixing concrete curing etc. to required height and clear wi
130Cut Stones
131Providing cut stone set in CM 1:3 (one cement and three sand) using well dressed cut stone supporting inlet pipe of size 0.30 x 0.30 x 0.15m for service reservoir etc., complete as per standard specifications and as directed by Engineer-in-charge.TWAD SOR
132OHT Ventilator
133AC Cylindrical Cowl
134Forming Ring Bund
135Forming Ring bund using sand bags filled with filling sand stiching the bags with jute coir conveing the stiched sand bags to preached site and forming the ring bund by placing the stiched sand bags in proper position , packing tightly and blocking the joints with clay and straw leaves to arrest the leakage as stated by departmental officers including the cost of empty cement bags, sand, jute coir complete for 2.83 cum.
136Flooring
137Providing Granolythic floor finish of the 25mm thickness with PCC 1:2:4 using 10 to 12mm hard broken stone jelly etc.- 1 Sqm
138WTP - Flooring
139Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured ceme
140WTP - Dadoing
141Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
142Water Level indicator
143Supply, delivery and fixing in position of water level indicator with float of approved pattern for inner and outer compartments including cost of materials etc. and as directed by the Dept. officers.
144Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail,Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
145Barricading Work
146Barricading work (Where the lines are in narrow width of municipality area,busy streets like Market, Bus-stand and in the Highways etc.) for laying ofpipe line using casurina poles at 1.50m center to center (8cm to 10cm dia.and 1.80m height) vertical with horizontal poles in two rows, painting thevertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing75mm dia. reflectors including earth work excavation for fixing verticalposts and finally removing and stacking the materials safely for further useetc., complete and as directed by TWAD Board officers.
147Traffic
148Non Traffic
149Lowering DI Pipes
150Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers.
151250 mm DI K7
152350 mm DI K7
153400 mm DI K7
154DI K9 Pipes of 400 mm diameter
155100 mm DI K7
156250 mm DI K7
157Lowering HDPE Pipes
158Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer.
159110 mm HDPE PN 10
160160 mm HDPE PN 10
161200 mm HDPE PN 10
162HDPE Pipes of 90 mm diameter
163HDPE Pipes of 110 mm diameter
164HDPE Pipes of 140 mm diameter
165HDPE Pipes of 160 mm diameter
166HDPE Pipes of 180 mm diameter
167HDPE Pipes of 200 mm diameter
168HDPE Pipes of 250 mm diameter
169HDPE 50 mm PN6
170Jointing Di pipes
171Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing material
172250 mm DI K7
173350 mm DI K7
174400 mm DI K7
175100 mm DI K7
176250 mm DI K7
177250 mm DI K7
178350 mm DI K7
179400 mm DI K7
180100 mm DI K7
181250 mm DI K7
182400 mm DI K7
183Jointing HDPE Pipes
184Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc.
185110 mm HDPE PN 10
186160 mm HDPE PN 10
187200 mm HDPE PN 10
18890 mm diameter (50.0m length for 1 Nos of Joints )
189110 mm diameter (50.0m length for 1 Nos of Joints )
190140 mm diameter (6.0m length for 1 Nos of Joints )
191160 mm diameter (6.0m length for 1 Nos of Joints )
192180 mm diameter (6.0m length for 1 Nos of Joints )
193200 mm diameter (6.0m length for 1 Nos of Joints )
194250 mm diameter (6.0m length for 1 Nos of Joints )
195HDPE 50 mm PN6
196Testing pipes
197Testing of D.I/HDPE pipes for water supply with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, ex
198110 mm HDPE PN 10
199160 mm HDPE PN 10
200200 mm HDPE PN 10
201250 mm DI K7
202350 mm DI K7
203400 mm DI K7
204HDPE Pipes of 90 mm diameter
205HDPE Pipes of 110 mm diameter
206HDPE Pipes of 140 mm diameter
207HDPE Pipes of 160 mm diameter
208HDPE Pipes of 180 mm diameter
209HDPE Pipes of 200 mm diameter
210HDPE Pipes of 250 mm diameter
211DI K9 Pipes of 400 mm diameter
212100 mm DI K7
213250 mm DI K7
214HDPE 50 mm PN6
215Refilling Trenches
216Refilling or backfilling trenches with excavated soil after pipe laying in layers not exceeding 20 cm in depth, ramming and consolidation of each layer, watering etc. all complete as per standard specifications and as directed by the Departmental Engineer
217110 mm HDPE PN 10
218160 mm HDPE PN 10
219200 mm HDPE PN 10
220250 mm DI K7
221350 mm DI K7
222400 mm DI K7
223HDPE Pipes of 90 mm diameter
224HDPE Pipes of 110 mm diameter
225HDPE Pipes of 140 mm diameter
226HDPE Pipes of 160 mm diameter
227HDPE Pipes of 180 mm diameter
228HDPE Pipes of 200 mm diameter
229HDPE Pipes of 250 mm diameter
230DI K9 Pipes of 400 mm diameter
231Construction of Brick work valve Chamber with M20 Grade concrete . The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of the pit, PCC M10 for Blinding Concrete, Brick work in CM 1:5 and plastering with CM 1:5 - 12mm thick, cost of steel reinforcement fabrication charges, Cover slab with manhole cover etc., and fixing the valves in position inside the pit including laying, jointing of valves, HDPE pipes and specials includingthe cost of jointing materials such as bolts and nuts RI sheets washers etc., complete and as directed by the Departmental Engineer.
232Construction of RCC spiral staircase in RCC M25 (one cement, one and half sand, three aggregates) using 20mm HBGS of 1.80m diameter of required height for approach to the roof of service Reservoir with RCC handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer, The staircase shall be braced to the column of service reservoir at suitable interval. (in the BOQ, quantity column the exact height to be mentioned from GL to roof slab bottom to get total value of work to be done.
233DI Pipes
234Supplying of K9 DI Pipe of dia following dia, conforming to IS 8329-2000 including all local and central taxes , transportation, freight charges, loading and unloading, conveyance to site and stacking the same, cost of all labour, material & etc complete.
235100 Mm DI K7
236250 Mm DI K7
237250 mm DI K7
238350 mm DI K7
239400 mm DI K7
240HDPE Pipes
241Supplying of HDPE pipe of PE 100 grade, PN -6 class conforming to IS 4984 including all local and central taxes , transportation, freight charges, loading and unloading, conveyance to site and stacking the same, cost of all labour, material & etc complete
242110 mm HDPE PN10
243160 mm HDPEPN 10
244Pipe
245HDPE Pipes of 50 mm diameter PN-10
246HDPE Pipes of 90 mm diameter
247HDPE Pipes of 110 mm diameter
248HDPE Pipes of 140 mm diameter
249HDPE Pipes of 160 mm diameter
250HDPE Pipes of 180 mm diameter
251HDPE Pipes of 20 mm diameter
252HDPE Pipes of 250 mm diameter
253DiK7pipe of 40mm diameter
254DI Specials
255Supply & Delivery to site ofall types of specials such as Tees, Tapers. Bends, endcaps etc as per specification.
256DI Specials 100- 200 mm dia
257HDPE Specials
258Supply & Delivery to site ofall types of specials such as Tees, Tapers. Bends, endcaps etc as per specification.
25990 mm
260HDPE bends
261HDPE Tees
262110 mm
263HDPE bends
264HDPE Tees
265140 mm
266HDPE bends
267HDPE Tees
268160 mm
269HDPE bends
270HDPE Tees
271180 mm
272HDPE bends
273HDPE Tees
274200 mm
275HDPE bends
276HDPE Tees
277250 mm
278HDPE bends
279HDPE Tees
280DI Valves
281Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16
282100 mmDI Sluice Valve
283150 mmDI Sluice Valve
284200 mmDI Sluice Valve
285250 mm DI Sluice valve
286300 mmDI Sluice Valve
287350 mm DI Sluice valve
288400 mm DI Sluice Valve
289100 mmDI Scour Valve
290150 mmDI Scour Valve
291200 mmDI ScourValve
292250 mmDI ScourValve
293350 mm DI Scour Valve
294150 mmDI NRV
295300 mmDI NRV
29650 mm Air valve
297100 mm Flow Control Valve
298150 mm Flow Control Valve
299200 mm Flow Control Valve
300250 mm Flow Control Valve
301100 mm CI Butterfly Valve
302250mm CI Butterfly valve
303450 mm CI Butterfly valve
30415 mm CI Ball Valve
305Flow Meter
306Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessorbased signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure,manufactured to highest standard available for mag-meters, equipped with minimum six digitdigital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and beconstructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and useclass PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall bewelded to the flow tube. The internal and external of the meter tube shall be blasted to nearwhite and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tubeshall have a constant nominal inside diameter offering no obstruction to the flow. The accuracyshould be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. CoilHousing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel withanticorriosive paint for corrosion resistance and welded to the tube providing a completely sealedenvironment for all coils, electrode connections and wiring harness capable of submerged orburied operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation typewith auto zeroing. The signal converter shall be remotely mounted away from the meter. Theconverter shall indicate direction of flow and provide a flow rate indication and a total of flowvolume for both forward and reverse directions. The converter shall provide an isolated 4-20 mAoutput into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and ascaled pulse output. The microprocessor based signal converter shall have a self-diagnostic testmode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”.Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipezero return. The signal converter housing should be die-cast aluminum with glass window. Theconverter cum transmitter should be fully programmable from the front facia. The programmingshould be user friendly, self-prompting menu driven. Flow meter test calibration certificate fromFCRI, flow test lab / NABL accredited lab to be furnished.
307100 mm DI Flow Control Valve
308150mmDI Flow Control Valve
309200mmDI Flow Control Valve
310250mmDI Flow Control Valve
311OHT Pipe Connection
312Supply and delivery of 150mm diaC.ID/F Pipe The rate shall inclusive of all charges such as materials and loading, unloading, transportation charges and all taxes etc, complete as per standard specification.
313150 mm CI Pipe
314250 mm CI Pipe
315Intake Well Pipe
316Supply, delivery & fixing of CI Pipes & Specials for the Drawl of Water into the well including labour Charges etc.,
317300 mm dia DI Pipes 2.00m Length
318300 mm Valve Specials
319300 mm dia DI Bend
320Supply, Delivery & Fixing of the Following size of Sluices Values manually operated with gear arrangements including all allied works
321300 mm DI Sluices values
322Provision for Wire Mesh to Prevent entry of Silt
323Supply, of following electromechanical items required for 2.5 MLD water treatment plant including the cost of transportation, installing and commissioning.
324Flash Mixer
325Intake Screen
326Flash Mixer Drive + Motor
327Flash Mixer Mechanism
328Flocculator
329Flocculator Drive + Motor
330Flocculator walkway - Common for Flash Mixer and Flocculator
331chlorination Dosing Pump
332Dosing pump
333Agitator for DosingTank
334DosingTank
335Alum Dosing Pump
336Dosing pump
337Agitator for DosingTank
338DosingTank
339Clarifier
340Clarifier Drive + Motor
341Clarifier Mechanism
342Sludge Transfer Pump
343Sludge Transfer Pump - Semi Open Impeller
344Filtration System
345Filtration Nozzles
346Filtration Underdrain System
347Gravel
348Sand
349Air Blower
350Air Blower Drive Motor
351Base Frame and Accessories including fasters
352Acoustic Hood
353Filter Press
354Filter Press
3553T capacity hand operated over head Travelling(HOT) crane suitable for a span upto 6 Mtrs, andtravel length upto 10 Mtrs. with clear lift upto 6 Mincluding gear type chain pulley block and gearedTravelling trolley complete with all accessoriesincluding girder
356Supply, of following Laboratoty instruments, Glass Wares and Chemicalsrequired for 2.5 MLD water treatment plant including the cost of transportation, installing and commissioning.
357Level Indicator Transmitter
358pH Indicator
359Flow Transmitter - Inlet Pump
360Flow Transmitter - Backwash Line
361Flow Transmitter - Product Water Line
362Turbidity Analyzer and Indicator
363Supply, of following Laboratoty instruments, Glass Wares and Chemicalsrequired for 2.5 MLD water treatment plant including the cost of transportation, installing and commissioning.
364Laboratory Instruments
365pH/ ORP Meter
366pH Solution - 4
367pH Solution -7
368pH Solution -10
369Cleaning Solution for General Purpose 500 ml
370Electrode storage solution 500 ml bottle
371ORP test solution @ 200/ 275 mV
372ORP test solution @ 240 mV
373ORP test solution @ 470 mV
374Portable EC/Resistivity/ TDS/NaCl Auto Ranging Meter
3751413 microsiemens EC Value
376Multiparameter Photometer with digital pH
377CalCheck Cuvette Kit
378Total HardnessPhotometer: Range LR: 0 to 250 mg/l
379CalCheck standard for Hardness
380Water Proof Portable DO, 230 V
381Zero Oxygen Solution - 500 ml
382DO probe electrolyte solution 500 ml
383Precision Turbidity and Free/ Total Chlorine Meter
384Muffle Furnace ( 200 x 200 x 300 mm)
385Vaccum Pump
386Hot Air Oven(355 x 355 x 355 mm)
387Magnetic Stirrer
388Centrifuge - Laboratory
389Vortex Mixer
390Round Hot Plate
391TKN Digester with Condenser
392Heating Mantle
393Microprocessor programme Temp controller
394Glasswares
395Bottle Reagent - 2 Liter
396Volumetric Flask - 250 ml
397Volumetric Flask - 500 ml
398Volumetric Flask - 1000 ml
399Filter Paper - 42
400Desicattors 3082
401Desicattor Plain with Knobbed
402Desicattor with Plastic 3082
403Measuring Cylinder - 500 ml
404Measuring Cylinder - 250 ml
405Burette 2122 - 50 x 0.1 Class B
406Pipette 7060 Mohr type 25 x 0.2 ml - Class B
407Pipette 7060 Mohr type 10 x 0.1 ml - Class B
408Pipette 7060 Mohr type 5 x 0.1 ml - Class B
409Pipette 7060 Mohr type 2 x 0.1 ml - Class B
410Bottle Reagent - 250 ml
411Bottle Reagent - 500 ml
412Bottle Reagent -1 liter
413Bottle Reagent -2 liter
414Bottle Reagent - 500 ml
415Gloves
416Tongs
417Bottle Reagent - 500 ml
418Silver Sulphate - 25 g
419Sulphuric Acid - 500 ml
420Hydrochloric Acid - 500 ml
421Sodium Hydroxide Pellet - 500 g
422Potassium Dichromate - 500 g
423Oxalic Acid - 500 g
424Earthling as per ISI Specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoal, common salt, G.I.reducer, check nuts etc.,and masonry work and providing RCC cover slab 38mm thick for the Brick masonry including cost of steel and fabrication of reinforcement etc., complete in all respects as directed by the departmental officers. (SD 233)
425Supplying and run off 8 SWG copper wire on walls or below ground level with necessary \"U\" nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75)
426Supplying and Fixing of 3 Phase DB with MCB 12 way TPMCB sheet steel distribution boards (flush type/surface type) fitted with bus bars and neutral links with three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pile incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD (totally 8 ways in one segment) (3 x 4 ways in each segment) and separate provisions for MCB / Isolator (totally 12 Nos.) for sub incomers in 3 segments with label holder etc.complete in all respects as directed by the departmental officers
427Supply and run off 2 of 2.50sqm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continuousearth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departmental officers. (derived from SD 55)
428Supply and run off 2 of 1.5 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 54)
429Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1\" x 1/8\" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1\" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 127)
430Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23
431Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38
43218 W 4 feet LED fitting wioth LED Single side PWD SOR Pg no
433Supply and fixing of 1200mm (48\") sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp (SD111)
434Supplying and fixing 12\" (30cm dia) light duty Exhaust fan including cost of all materials,labour, lead, lift, etc complete SD 114
435HT Service connection:
436DP Structure
437Supply, delivery of 6 pole structure materials with suitable Size RSJ along with all structure materials are as under for 22 KV Substation.
438Chain link fencing with gate including the TNEB2 poles Spreading of materials as per CEIG requirements
439Transformer yard earthing using copper flat and TWIN earthing as per IS(Above 250 KVA Transformer sub station)
440Transformer sub station erection charges
441Distribution transformer - 11 kV/433V, DyN11, 250 KVA
442On Load Tap Changer (OLTC) for transformer with Remote Tab Changer Control Panel
443Supply and delivery of 4 Runs X 3 1/2 core 150 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between Transformer secondary to PCC Panel
444Cable lugs for 150 sq.mm
445Cable laying
446Construction of transformer plinth
447Civil works in DP Yard: Supply, levelling of 38mm blue granite jelly ( Depth-6\") over layer of sand & Fencing Support works
448Safety items for Substation & WTP
449LT Electrical gloves
450Electrical gloves tested to 11 KV /22 KV with wooden box dusted with french chalk powder
451Electrical quality 6mm thick rubber mat
452Fire Bucket-3 Nos Hooked to MS stand
4535 kg capacity ISI marked Dry chemical powder fire extinguisher
454Laminated shock treatment chart
455Wooden First Aid Box
456Three wire discharge rod
457Wooden ladder for HT Supply (5 Mtr)
458LED Rechargeable Emergency lamp for industrial use
459Statutory Charges for TANGEDCO
460Development charges (Over head)
461Earnest Money deposit
462Security deposit
463Meter caution deposit, 22kV - Meter plus Metering set with Panel
464Registration charges
465Designing and preparation of CEIG drawings, obtaining Approval and safety certificate including submission of Completion report and rectification report for substation and related works.
466PMCC Panel
467Fabrication & Supply of M V Cubical Panel board vermin proof box of CRCA sheet 16 SWG powder coated, door with 180 degree opening, poly urethane/rubber gaskets as per IE rules - 1m2, Mechanical interlock for PCC with DP structurePanel type: CompartmentalizedBusbar: AluminumQuantity of Incomer feeders with metering chamber:(i) EB Incomer:1 No. of 1250 Amps, 4 Pole ACB, EDO typeQuantity of Outgoing feeders:(i) 63 Amps SFU with HRC Fuselink-2 Nos.(ii) 250 Amps SFU with HRC Fuse link - 6 Nos. ( 1No. for existing 6.5 MLD WTP)(iii) 400 Amps SFU with HRC Fuse link - 2 Nos. ( 1No. for existing 6.5 MLD WTP)
468Panel incomers with metering chamber
4691250 Amps, 4 Pole, EDO type Air Circuit Breaker with Microprocessor based Trip unit (O/C, E/F, S/C)
4702 lock with 1keyMechanical Interlocking System forM V Panel Board
471Digital Multifunction meter- Three Phase Class 1-AC
472Digital Voltmeter- Three Phase Class 1-AC
47396 mm X 96 mm Three Phase Digital Ammeter Class 1-5A
474LED indication lamp for R,Y,B phase identification, ACB-ON/OFF, Circuit healthy, TRIP indication lamp
475Trip and Close Switch
476Closing Coil
477Current Transformer for Metering & Protection
478Cable duct, DIN tail, Auxiliary block for power contactor, Power & Control terminal block, end plate and end clamp and necessary accessories
479Aluminium flat for Horizontal Main bus & Vertical bus@ 0.7 Amps / sq.mm & Earth flat
480Bus bar support, Base frame, supporting angle / channel, Panel internal wiring for entire panel
481Outgoing Feeders of PMCC Panel
48263 Amps TPN, SFU with HRC fuse Link for LDB & PDB panel - Each 1 No.
483250 Amps TPN, SFU with HRC fuse Link (i) Existing Raw water pump room, MCC panel for new WTP, APFCR Panel, Spare - Each 1 No.)(ii) Proposed Clear water pump - 2 Nos.
484400 Amps TPN, SFU with HRC fuse Link - Proposed Clear water pump - 2 Nos.
485Soft starter with Bye pass contactor in Standalone panel
486Supply and delivery of floor mounted type soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including MCCB with Microprocessor based Trip unit, Semiconductor fuse, Bye pass contactors suitable for 29 KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button.
487MCC Panel
488Fabrication & Supply of M V Cubical Panel board vermin proof box of CRCA sheet 16 SWG powder coated, door with 180 degree opening, poly urethane/rubber gaskets as per IE rules - 1m2, Panel type: CompartmentalizedBusbar: 250 Amps Aluminum with designing of 0.7 Amps / Sq.mm Busbar, Quantity of Incomer feeders with metering chamber:Incomer:1 No. of 250 Amps, 3 Pole MCCBQuantity of Outgoing feeders:(i) DOL feeder upto 5.5kW : 10 Nos.(ii) Star-Delta feeder: 25 kW : 2 Nos.,40 kW : 2 Nos, (iii) 32 Amps SFU with HRC Fuse link - 7 Nos.(iv) Empty feeder suitable for 63 Amps SFU - 2 Nos for future use.
489Panel incomers with metering chamber
490250 Amps, 3 Pole, MCCB with Microprocessor base Trip Unit ( Over current, Earth fault, Short Circuit), Extended rotary Handle, Phase Barrier, Spreader Terminal with all accessories
491Digital Multifunction Meter, Three Phase Class 1-AC
492LED indication lamp for R,Y,B phase identification, MCCB Trip indication
493Current Transformer for Metering & Protection (250/5A)
494MCB, 2Pole/3Pole
495Control transformer, Resin Cast, Moulded type (440/110V AC) with selector switch
496Cable duct, DIN tail, Auxiliary block for power contactor, Power & Control terminal block, end plate and end clamp and necessary accessories
497Size of Aluminium flat shall be designed with Current carrying: 0.7 Amps/ q.mm and both Horizontal Main bus & Vertical bus with equal rating of panel incomer,& 50 X 6 mm Aluminium Earth flat.
498Control busbar
499Bus bar support, Base frame, supporting angle / channel, Panel internal wiring for entire panel
500Feeder for Raw Water Pump; Rating: 25 KW; Type: Star-Delta Starter Quantity -Nos.2
501100 Amps TPN Switch fuse Unit with 80 Amps Fuse link
50245 Amps, 3Pole Power Contactor
503Bimetallic Thermal overload relay ( 30-50 Amps)
504Star -Delta Timer
505LED indication lamp for ON, OFF, Trip, indication lamp
506\"ON\" Pushbutton and Emergency STOP Push button, Mushroom type Actuator, Push to Close and Turn to Release
50796 mm X 96 mm Three Phase Digital Ammeter Class 1-5A
508Current Transformer for Metering
509Auxiliary contactor for ON,OFF & Trip
5106 Amps, 2Pole Control MCB
511Auxiliary block for power contactor, Power & Control terminal block, end plate and end clamp and necessary accessories
512Feeder for Backwash blower ; Rating: 24KW; Type: Star-Delta Starter Quantity - 2 Nos.
51363 Amps TPN Switch fuse Unit with 32 Amps Fuse link
51418 Amps, 3Pole, Power Contactor
515Bimetallic Thermal overload relay ( 9-15Amps)
516Star -Delta Timer
517LED indication lamp for ON, OFF, Trip, indication lamp
518\"ON\" Pushbutton and Emergency STOP Push button, Mushroom type Actuator, Push to Close and Turn to Release
51996 mm X 96 mm Three Phase Digital Ammeter Class 1-5A
520Current Transformer for Metering
5216 Amps, 2Pole Control MCB
522Auxiliary block for power contactor, Power & Control terminal block, end plate and end clamp and necessary accessories
523Outgoing feeders
52463/32 Amps TPN Switch fuse Unit with Fuse link for LCP of filter press, Clarifier, Chlorination & Control transformer
525Panel utility
526Thermostat with space heater, 6 Amps, 2 Pole MCB, Door switch with CFL lamp
527Erection, testing commissioning charges
528APFCR panel
529Fabrication & Supply of M V Cubical Panel board vermin proof box of CRCA sheet 16 SWG powder coated, door with 180 degree opening, poly urethane/rubber gaskets as per IE rules - 1m2.Panel type: Non -CompartmentalizedBusbar: AluminumQuantity of Incomer feeders with metering chamber:(i) Incomer:1 No. of 250 Amps, 3 Pole MCCBQuantity of Outgoing feeders:(i) 25 kVAR Capacitor : 3 Nos.(ii) 10 kVAR Capacitor : 1 No.(iii) 5 kVAR Capacitor : 2 Nos.(iv) 2 kVAR Capacitor : 2 Nos.(v) 1 kVAR Capacitor : 1 Nos.
530250 Amps, 3 Pole, MCCB with Microprocessor base Trip Unit ( Over current, Earth fault, Short Circuit), Extended rotary Handle, Phase Barrier, Spreader Terminal with all accessories
531APFCR relay with 8 Stage output
532Digital VAF- Three Phase Class 1-AC
533LED indication lamp for R,Y,B phase identification, Capacitor-ON indication
534Current Transformer (250/5A)
535Cable duct, DIN tail, Terminal block, end plate and end clamp and necessary accessories
536Base frame, supporting angle / channel, Panel internal wiring, earthing for entire panel
537Power capacitor for power factor improvement with oil filled with discharge resistance Heavy Duty, 3 phase 525 Volts 50 HZ conforming to ISS:2834 with ISI marking
538MCCB, Heavy duty Capacitor duty contactor, Illuminated ON/OFF push button for each rating
539MCCB, Heavy duty Capacitor duty contactor, Illuminated ON/OFF push button for each rating
540Erection, testing commissioning charges
541Power & Control Cable
542Supply and delivery of 1Run X 3.5 core 185 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to existing Raw water Pump room
543Supply and delivery of 1Run X 31/2 core 240 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to existing Clear water Pump room
544Supply and delivery of 1Run X 31/2 core 185 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to MCC panel of New WTP.
545Supply and delivery of 31/2 core 185 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to 105 kVAR Panel.
546Supply and delivery of 4 core 6 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to LDB Panel
547Supply and delivery of 4 core 6 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between PMCC to PDB Panel
548Supply and delivery of 2Runs X 3 core X 16 sq.mm. 1100V AC, PVC Aluminium Armoured UG Cable with ISI MARKCable distance between MCC to Raw water pump of New WTP.
549Supply and delivery of 1Run x 3 core X 2.5 sq.mm, Copper conductor, armoured, XLPE insulated ,UG Cable with ISI MARK for the Sub Light distribution Boards
550Supply and delivery of 1Run x 3 core X 2.5 sq.mm, Copper conductor, armoured, XLPE insulated ,UG Cable with ISI MARK for the following equipments.
551Cable distance from MCC panel to Flash mixer - 2 Nos.
552Cable distance from MCC panel to Flocculator - 2 Nos.
553Cable distance from MCC panel to FeCl3 Agitator - 2 Nos.
554Cable distance from MCC panel to Poly agitator - 2 Nos.
555Cable distance from MCC panel to Alum dosing pump - 2 Nos.
556Cable distance from MCC panel to poly dosing pump - 2 Nos.
557Cable distance from MCC panel toVaccum pump - 2 Nos.
558Cable distance from MCC panel to Filter press
559Cable distance from MCC panel to Clarifier mechanism
560Supply and delivery of 5 core, 1.5 sq.mm, 1100V AC, XLPE Copper Armoured UG Cable with ISI MARK Cable distance between MCC panel to Individual equipments
561Supply and delivery of 19 core, 1.5 sq.mm, 1100V AC, XLPE Copper Armoured UG Cable with ISI MARK Cable distance between Transformer marshalling to RTCC panel
562Supply & termination of cable lugs and excavation, refilling, laying of cable
563Lighting fixtures
5647 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm)114.30mm OD x 5.40mm Thick x 4000mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.1mm OD x 3.25mm Thick x 1500mm Length
565Main Light distribution board: Industrial type 12 Ways Three Phase DB with IP54 Protection with MCB and ELCB
566Light distribution board: Industrial type 12 Ways Single Phase DB with IP54 Protection.
56710 Amps 30mA TP ELCB
568Double Pole 6A to 32A, 10KA
569Switch board with 6A switch
5706/16A Socket - 3 Module
57130W LED Street Light Fitting for Walkway platform & storage TankMake: Philips / Havells
572120W LED Street Light Fitting with LED
57320W 4 Feet LED fixtures
574AC Ceiling Fan 1200 mm
575AC Exhaust Fan 300 mm (12”) sweep(Lightduty)
576MS/Fibre Louvers shutters arrangements for 300mm AC Exhaust Fan
577Supply, wiring for indoor & outdoor light fittings with conduits.1.5 sq.mm for indoor wiring and 2.5 sq.mm for street fitting
578Street light junction box
579Erection and commissioning charges
580Local Push button Stations with Supports
581Supply & erection of Local ON/OFF push button station near the Pumps.(a ) Enclosure shall be Thermoplastic and suitable for 5 Core X 1.5 Sq.mm, Bottom entry, 3/4\" 2 Way cable entry, double compression gland.(b) 1 No. of Non illuminated \"ON\" Green Colour Push button with 2 NO + 2 NC contact.and1 No. of Emergency Stay put Red Colour Mushroom actuator, Press to Lock & Turn to release \"OFF\" push button with 2 NO + 2 NC contact without key type.(C) Supply of accessories including Name plate, SS fasteners, Neoprene endless moulded gasket, 2 Nos. of Earthing, Screw type terminal blocks with Spare.(d) Fabrication & supply of ISMC 100 Channel supports for fixing the Push button station at 1.2 m Height from ground level, one coat of primer & painting along with all necessary accessories & hardwares
582Earthing arrangements
583Twin CI Earthing as per IS 3043/1987 and Latest amendments upto 150 HP
584Supply, laying, termination of earth flat for the following items:(i) 2 Runs X 65 mm X 10 mm GI earth flat for Panel (ii) 2 Runs X 25 mm X 3 mm GI earth flat for11 Kw and 30 kW.(iii) 2 Runs X 50 mm X 6 mm GI earth flat above37 kW
5852 Runs X 8 SWG green colour sleeved copper wire for street light & Local push button station
586Cable tray
587GI Hot dip/ Powder coated 16 SWG Cable tray with 50/100/150/200/300mm width and 50mm height
588Chequered Plate, MS Channel & supports
589Fabrication & erection charges
590Electrical safety certificate
591Designing and preparation of CEIG drawings, obtaining Approval and safety certificate including submission of Completion report and rectification report for WTP equipments.
592Supply and delivery of clear water vertical wet type submersible pump suitable for 100mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due toall causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two polesuitable wet type vertical squirrel cage induction motor as per IS9283 /1995 and asamended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50HZ +/- 5 %
593Duty 1000 lpm and 60 m head
594Duty 800 lpm and 40 m head
595Vertical turbinepump
596Supply and delivery of Vertical water/Oil lubricated statically, dynamically, hydraulically balanced Turbine pump capable of dischargingthe followingduty condition as given belowdue to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessoriesas per IS 5120/1977 ( Reaffirmed 2011 ) and as amended thereafter to suit the site condition.The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 rpm. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete (Rates given are with suspension length of 7m, bronze impeller, SS 401 shaft, MS column pipe,discharge case & CI bell mouth.)
597Duty 4000 lpm and 30 m head
598Horizontal Split Casting Centrifugal pump
599Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing andsplit glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, doubleflap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable foroperation in AC three phase, 415 V, 50 Hz, 1500 RPM.
600Duty 4000 lpm and 55 m head
601Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and asamended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with undervoltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale,Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, ThermalOverload relay, Air Break contactors suitable for next Standard higher KW rating,Single phasing preventor, dry running preventor and On/Off Push button switches,wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated verminproof box, including the capacitor (the cost of capacitor is to be taken separately).
60215 Hp
603Soft Starter
604Supply and delivery of suitable KW indoor automatic air cooled dust and vermin proof FLEX COMPENSATED MAGNETIC AMPLIFIERSoft Starter for the operation in 3.3 KV three Phase 50 HZ, AC supply termination with phase segregated neutral terminal box of the motor , housed in 14 SWG sheet steel enclosure, painted with epoxy or polyurethene , 230V AC 10 Amps control supply , Class B insulation, 300 mm height fabricated pedastal (to prevent water ingress for starter panel) and condensation heater with switch with thermostat, interlocking with running motor with built in facility for run mode/by pass etc. complete. The starter may be provided with contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6 Nos, LED ON/OFF typeand Start /Stop push button. SUITABLE FORH.T. SQUIRREL CAGE MOTOR
605FCMA SOFT STARTER-38 HP
606labour Charges
607Labour charges for the erection of submersible pumpsetin borewell/openwell including fixing and jointingsubmersible cable with proper clamps upto the starter torequired depth and also fixing of riser pipes to therequired depth valves erection clamps, pressure gaugesupto the exterior wall of pump room and erection ofpanel board consisting of TPICN switches starter,Voltmeter, Ammeter, three pilot (indicating) lampscapacitor single phasing preventor, water level guard andlaying and jointing the cables and twin earthing as per IErules etc., complete and testing the pumpset and trailrun for 10 days.
60810-20 hp
609Horizontal Split Casting Centrifugal pump & Vertical Turbine Pump
610Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities.
611Providing TWIN Earthing to all starters
612Upto 25 HP
613Above 25 upto 60 HP
614Cable:supply and fixing of 4 sq mm PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER .
615Supply and delivery of brand new approved make 1.1 KV grade armoured aluminium conductor cable confirming to ISS 1554 part I with ISI marking includingloading, freight, transit insurance, incidental charges, packing, taxes and unloading, stacking at site in good condition including excise duty etc., complete as directed by the TWAD Board officers.
6163.5 C x50 Sqmm (Aluminium) (From pole toMV panl)
6173 C x 35 Sqmm (Aluminium) (From MDB panel to Pumpset through starter
6183 C x 10 Sqmm (Aluminium) (To capacitor)
6194 Cx 4 Sqmm (Aluminium) (To lighting)
6203C x 2.5 sq.mm Copper cable for control system
621Laying of 1.1 KV class UG cable in trench / GI pipe /on pole as required.and as directed by Engineer incharge.
6223.5 C x50 Sqmm (Aluminium) (From pole toMV panl)
6233 C x 35 Sqmm (Aluminium) (From MDB panel to Pumpset through starter
6243 C x 10 Sqmm (Aluminium) (To capacitor)
6254 Cx 4 Sqmm (Aluminium) (To lighting)
6263C x 2.5 sq.mm Copper cable for control system
627JOINTING OF L.T.CABLES 3,3.5,4CORE 1.1KV GRADE ARMOURED ALUMINIUM CONDUCTOR CABLE CONFIRMING TO IS1554 AND AS AMENDED THERE AFTER PARTI WITH ISI MARKING
6283.5 C x50 Sqmm (Aluminium) (From pole toMV panl)
6293 C x 35 Sqmm (Aluminium) (From MDB panel to Pumpset through starter
6303 C x 10 Sqmm (Aluminium) (To capacitor)
6314 Cx 4 Sqmm (Aluminium) (To lighting)
6323C x 2.5 sq.mm Copper cable for control system
633Supply and delivery of 150mm dia Bourden tube type pressure gauge (glycerin filled)with concentric scale suitable for pumpsets in item I duly mounted on a teak wood Board to be fixed on well of the pump house with required copper tube connection with brase stop cock etc.The gauge should conform to relevant I.S. 3624
634Supply and delivery of following safety appliances includingloading, freight, transit insurance, incidental charges, packing, taxes and unloading, stacking at site in good condition including excise duty etc., complete as directed by the TWAD Board
635Electrical gloves tested to 11 KV / 22 KV with wooden box dusted with french chalk powder
636Supply and fixing of Electrical quality 6mm thick rubber mat
637Supply and fixing of 5 Kg capacity ISI marked Dry chemical powder fire extinguisher
638Supply and fixing of fire bucket - 3 Nos. hooked to MS stand
639Supply and fixing of laminated shock treatment chart
640Supply and fixing of wooden first aid box
641Supply and fixing of Rechargeable Emergency lamp (600mm Fluoracent lamp)
642Supply and Delivery of Tools required for Pumproom
643Provision for DI Pipe connection
644Electro Magnetic Flow Meter-300 mm
645300 mm DI PN10 Flanged pipes (2m length pipes) - Intake Well
646HSC Connection - 20 mm - Providing House service connection with MDPE 20mm pipe (supply, lowering, jointing & testing), electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304,Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threadedto suit the corresponding bore sizes of 15mm dia size ( 1/2\", ),Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 , Poly propylene 90 Degree Compression elbow with compression joint at both ends, Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 and protection box of size 20cm x 30cm for fixing of Water Meter all as per standard including road cutting, replacement of utilities providing house service connection, refilling, retoration of roads/drains testing etc complete with materials and specification as instructed by department officers.
647Providing & fixing PVC RAIN WATER DOWN FALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes, Bemds, other clamps, screws nails etc., complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm](D)
648Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitaryfittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.(D)
649110mm dia pipe
650Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
651Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work.
652Gun Metal Gate Valve
65332mm Gun metal Gate Valve
65440mm Gun metal Gate Valve
655Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
656SD Tap
657Pillar Tap
658Internal Water Supply Arrangements using PVC pipes and PVC specials
659Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.
660Coupler
66125mm Pipe
66232mm Pipe
663Elbow
66425mm Pipe
66532mm Pipe
666BEND
66725mm Pipe
66832mm Pipe
669Tee
67025mm Pipe
67132mm Pipe
672End Cap
67325mm Pipe
67432mm Pipe
675Reducer
67625 mm x 20 mm
67732 mm x 25 mm
678Reducer Tee
67925 mm x 20 mm
68032 mm x 25 mm
681Reducer Elbow
68225 mm x 20 mm
68332 mm x 25 mm
684Jet Nipple
68525mm Pipe
68632mm Pipe
687Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthenware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylon connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
688White Wash Hand Basin With Pedestal
689Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440mm White/Color glazed earthen ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works).
690Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....
691White EWC
692Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)

AI Tender Summary

OUR REF NO 36913620
AUTHORITY Local Bodies
TENDER VALUE 28.28 Crore
LAST DATE 12-04-2023
Authority
Authority Name Town Panchayats
Work Description Improvements Of Water Supply Scheme To Uthamapalayam Town Panchayat, Theni District Under Amrut 2.0 Scheme
Basic Detail
Tender No 226/2022
Bidding Type Tender
Location
City uthamapalayam
State Tamil Nadu
Key Dates
Publish Date 06 Apr 2023
Submission Date 12 Apr 2023
Open Date 12 Apr 2023
Finance
Tender Value 28.28 Crore
Tender Fee Ref. Documents
EMD 28.28 Lakhs
Exemption Not Available
Document List
BOQ_351734.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
54d03b72-3f95-42b3-ac6f-400df730d996.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 06, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 12, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 12, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 12, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_351734.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

html

54d03b72-3f95-42b3-ac6f-400df730d996.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail