Tender For Construction Of Lora Svs Solar Based Rural Pipe Water Supply Scheme (Jjm) Under Dandai Block For The Year, garhwa-Jharkhand

Drinking Water And Sanitation Department has published Tender For Construction Of Lora Svs Solar Based Rural Pipe Water Supply Scheme (Jjm) Under Dandai Block For The Year. Submission Date for this Tender is 28-03-2023. Solar Power Plants Tenders in garhwa Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

36901051
Tender For Construction Of Lora Svs Solar Based Rural Pipe Water Supply Scheme (Jjm) Under Dandai Block For The Year
Open Tender
Indian
Jharkhand
garhwa
28-03-2023

Tender Details

Construction Of Lora Svs Solar Based Rural Pipe Water Supply Scheme ( Jjm ) Under Dandai Block For The Year 2022-23 ( Group No. 10 ) ( 1St Call )

Key Value

Document Fees
INR 5000 /-
EMD
INR 63000.0 /-
Tender Value
INR 31.44 Lakhs /-

BOQ Items

Name of Work :-Construction of Rural Pipe Water Supply Scheme, Lora , SVS (JJM) under Dandai Block through DT/HYDT/GPT (Solar based) 01/2.0 H.P. DC Motor pump complete set for different tolas of concern villages which is not included/included in MVS and has no electricity or less electricity to supply water 2000 LPH maximum at least 15/30 year for 24x7 supply with 100% coverage by Tap water Facility under (JJM) For the year 2022-23
Sl. No. Item Description
1MODEL-1B WITH SOURCE- 4 No of Scheme
2(Drilled T/W 125/115dia mm, 60M Deep)Tube Well
3Drilling Portion
4Construction for 115/125 mm dia drilled Tube-Well for drilling in all kinds of soil rock for installation of hand pump with D.T.H Rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant for making 125/115 mm dia boring etcand cost of transporting rig machine and other vehicle up to site workas per specification and direction of Engineer-in-charge.
5(a) Up to 30mtr. Depth bellow G.L. in Rural Areas
6(b) Beyond 30mtr.In Rural Areas
7Providing all equipments and labour for lowering 125mm dia blue UPVC Casing pipe as casing for protecting the side from falling during the process of drilling all complete job including carriage of material to work site.
8Supplying labour cement and calcium chloride or bentonite solution and equipments for Grouting to Casing Pipe all complete job including carriage of material to work site as per specification & direction of E/I
9Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction E/I.
10Supplying all materials labours and equipment including 125 mm dia GI/CI cap 125 mm dia T/W properly all complete and taking it out as per specification & direction of E/I. (the cap will be property of department)
11Supplyingmaterials and labours for constructing bore well chamber of 75 B designation brick masonry chamber 600 mm x 450 mm and 750 mm deep internal dimension having 250mm thickness in cement mortar 1:6 including 12mm cement plaster 1:6 with 600 mm x 475 mm RCC cover with earth work in excavation and 75 mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
12RCC Foundation for Steel structurestaging& Solar panel
13Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I(vide classification of soil item -B)
14Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I
15Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I
16Providing nominal mix PCC of (1:4:8) in foundationwith approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I
17Providing RCC M-20 in nominal mix of (1:1.5:3) in columnswith approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.
18(a)Foundation for Steel structure staging
19Footing and Vertical Pedestal Raft
20Column
21Tie Beam
22Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.
23(a) Foundation for Steel structure staging
24Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
25Cement Lead 10 Km (avg.)
26Sand Lead 36 Km (avg.)
27Stone Chips Lead 11 Km (avg.)
28Steel Reinforcement Lead 10 Km (avg.)
29Bricks Lead 06 Km (avg.)
30Galvanized tubular Steel structure staging forHDPE water storage Tank& Solar Panel
31Providing structural steel galvanisedsqure pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.
32Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete
33Installation of 5000 liters Capacity Water Storage Tank
34Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 5000.00 litres Capacity Water storage Tank
35Transportation Charge
36Lifting of 5000 Litrs Capacity Tank up to 4.00m height with lifting tools with rope and labour
37Making hole in Tank
38Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.
39Rising and Distribution Network with House Connection up to 20 Nos. including Platform & Stand post
40Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
41Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete
42Providing PCCM-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion
43Rising Main
44Manufacture, supply and Delivery offollowing Nominal dia UPVC column pipes including PVC socket (Coupler),
4565mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:74.5 to 75.2mm wall Thickness End:9mm to 10.7mm, Barrel 9mm to 10.7 mm, Length: 3Mtrs.Rising main
4650 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe
47Distribution
48Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074materials rates are Ex-factory excluding transportation, taxes and duties.
4963 mm HDPE Pipe
5050 mm HDPE Pipe
5132 mm HDPE Pipe
5220 mm HDPE Pipe
53Providing and supplying High Density Polyethylene(HDPE )fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074materials rates are Ex-factory excluding transportation, taxes and duties.
54Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.
55For Rising
5650 mm HDPE Pipe
5765 mm HDPE Pipe
58Distribution
5965 mm HDPE Pipe
6050 mm HDPE Pipe
6132 mm HDPE Pipe
6220 mm HDPE Pipe
63Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.
64Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.
65Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.
66Elbow 15 mm dia.
67Reducer Socket 20x15 mm dia.
68Nipple 15 mm dia.
69Plain Socket 15 mm dia.
70Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.
71Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.
7265 mm dia Full way valve
7350 mm dia and weight not less than 1.5 Kg.
74Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socketall complete as per specification and direction of E/I.
7515 dia and weight not less than 400 Gm
76Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. Full way valve chamber
77Supplying materials , labours and equipment"s for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surfaceall complete job, as per approved design, specification and direction of E/I.
78Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.
79Providing fitting & fixing 32 mm to 50 mm service HDPE saddleall complete job, as per approved design, specification and direction of E/I.
80Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
81Cement Lead 10 Km (avg.)
82Sand Lead 36 Km (avg.)
83Stone Chips Lead 11 Km (avg.)
84Steel ReinforCement Lead 10 Km (avg.)
85Bricks Lead 06 Km (avg.)
86Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump
87Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
88SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PVmodules should be minimum 200 watt peak.
89i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
90ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
91iii) The PV modules shouldbe mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
92iv) The module mounting structure should be hot dip galvanized according to IS 4759.
93v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
94vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
95vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
96viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
97ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
98x) The motor pump set should have a 5 years warranty.
99xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
100xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
101xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
102xiv) With third party inspection before dispatch.
103xv) Provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs.
104The following details should be marked indelibly on the motor pump set
105a) Name of the Manufacturer or Distinctive Logo.
106b) Model Number.
107c) Serial Number.
108Solar submersible motor pump (SPV DC Type)
109i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)
110Provision of solar night lamp.
111Annual Operation & Maintenance cost based on Existing D/T Well with solarmotor pump for 5 years
112O & M Cost for 1st year (Excluding Repair Charges)
113O & M Cost for 2nd year with Annual Repair Charges
114O & M cost for 3rd Year
115O & M cost for 4th Year
116O & M cost for 5th Year
117Provision of one no SIM card & its recharging cost for RMC
118Add 18% GST
119Add 1% Labour Cess
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail