Military Engineer Services-MES has published Tender For Repair/Maint Of Dg Set, Amf Panel, Street Light And Allied Works In Zone B At Kwc Rnd Delhi And Internal Wiring, Distrubution Boards, Electric Fittings/Fixtures And Other Connected Works At Drde Gwalior Under Ge I Rnd Delhi. Submission Date for this Tender is 13-05-2023. Electrification Work Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36896089
Corrigendum : Tender For Repair/Maint Of Dg Set, Amf Panel, Street Light And Allied Works In Zone B At Kwc Rnd Delhi And Internal Wiring, Distrubution Boards, Electric Fittings/Fixtures And Other Connected Works At Drde Gwalior Under Ge I Rnd Delhi
Open Tender
Indian
Delhi
delhi
13-05-2023

Tender Details

Repair / Maintenance Of Dg Set, Amf Panel, Street Light And Allied Works In Zone B At Kwc Rnd Delhi And Internal Wiring, Distrubution Boards, Electric Fittings / Fixtures And Other Connected Works At Drde Gwalior Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Apr-2023 Corrigendum01 Date 17-04-2023
2 10-Apr-2023 Corrigendum02 Date 24-04-2023
3 18-Apr-2023 Corrigendum03 Date 01-05-2023
4 25-Apr-2023 Corrigendum04 Date 06-05-2023
5 27-Apr-2023 Corrigendum05 BOQ 06-05-2023
6 06-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 73700.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/MAINT OF DG SET, AMF PANEL, STREET LIGHT AND ALLIED WORKS IN ZONE B AT KWC RND DELHI AND INTERNAL WIRING, DISTRUBUTION BOARDS, ELECTRIC FITTINGS/FIXTURES AND OTHER CONNECTED WORKS AT DRDE GWALIOR UNDER GE I RND DELHI
Sl. No. Item Description
1M&L for general servicing by authorised rep of manufacturer of DG set 15 KVA to 20 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters etc complete all as specified and directed.
2M&l for general servicing by authorised rep of manufacturer of DG set 30 KVA to62.5 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
3M&L for for general servicing by authorised rep of manufacturer of DG set 160 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
4M&L for general servicing by authorised rep of manufacturer of DG set 320 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
5M&L for general servicing by authorised rep of manufacturer of DG set 437.5 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed. Note: 1. All worn out parts from item No 1 to 6 and oil shall be measured and paid separately under respective items. 2. The quoted Rate is inclusive of all required tools and plants to carry out the work/Job.
6M&L in repair of self starter 12 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 15 KVA to 20 KVA complete all as specified and directed.
7M&L in repair for self starter 12 V including rewinding of armature with super enameled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 62.5 to 100 KVA complete all as specified and directed.
8M&L in repair self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 160 KVA complete all as specified and directed.
9S&F in replacement automatic battery charger with auto cut OFF suitable for charging of 2X12V, 180AH batteries complete with all required necessary wiring complete all as specified and directed.
10M&L in repair AMF panel DG set 15 KVA to 62.5 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
11M&L in repair AMF panel of DG set 70 KVA to 160 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
12M&L in repair AMF panel of DG set 200 KVA to 450 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
13S&F in replacement self starter 24 volts suitable for upto 160 KVA DG sets complete all as specified and directed.
14S&F in replacement self starter 24 volts suitable for upto 320 KVA DG sets complete all as specified and directed.
15S&F in replacement battery brass terminals heavy duty suitable upto12V, 180 AH battery with minimum 2 RM Battery Lead of copper Cable single core complete all as specified and directed.
16S&Fin replacement relay, 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed.
17S&F in replacementengine starting relay suitable for DG set of capacity 15 KVA to 20 KVA as per matching to existing complete all as specified and directed.
18S&F in replacementengine starting relay suitable for DG set of capacity 62.5 KVA to 100 KVA as per matching to existing complete all as specified and directed.
19S&F in replacementengine starting relay suitable for DG set of capacity 160 KVA as per matching to existing complete all as specified and directed.
20S&F in replacement Electronic timer suitable for AMF panel of DG set 62.5 KVA to 100 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
21S&F in replacement Electronic timer suitable for AMF panel of DG set 160 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
22S&F in replacement Electronic timer suitable for AMF panel of DG set 320 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
23S&F in replacement Electronic timer suitable for AMF panel of DG set 437.5 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
24S&F in replacement Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
25S&F in replacement Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
26S&F in replacementAmmeter analog type for current range of (0-24Amps) as per matching to existing with all accessories and wiring complete all as specified and directed.
27S&F in replacementAmmeter analog type for current range of (0-1000Amps) as per matching to existing with all accessories and wiring complete all as specified and directed.
28S&F in replacement power contactor 400 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
29S&F in replacement selector switch suitable for voltmeter and Ammeter complete all as specified and directed.
30S&F in replacement of under voltage relay suitable for DG set of capacity 62.5 KVA to 100 KVA complete all as specified and directed
31S&F in replacement of under voltage relay suitable for DG set of capacity 320 KVA complete all as specified and directed
32S&Fin replacement complete wiring with single core multistranded copper cable with flexible 20mm PVC conduit for DG set of various capacities complete all as specified and directed.
33Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
34M&L for Earth continuity conductor or main earthing lead 25x4 mm galvanised iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required complete all as specified and directed.
35Material and Labour for earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper strip of 20x3 mmby means of copper nuts, bolts and washers.Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)Copper strip of size 20mm x 3mm. (b) Watering pipe GI light grade 25mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
36S&F of copper strip of size 20x3 mm including all connected accessories complete all as specified and directed.
37Supply, fixing and testing Electronic Governor Controller for 320 KVA DG Set including taking down old unserviceable Governor Controller complete all as specified and directed.
38S&F new actuator for 320 KVA DG Set complete including taking down old unserviceable actuator complete all as specified and directed.
39Opening the DG set of 320 KVA including cleaning of radiator fins/tubes, repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line, belts & Bearings including re-assembling the complete parts and testing complete all as specified and directed. Note:- Spare parts required for replacement shall be measured and paid separately under respective items.
40S&F Piston ring and liner for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
41Supply only Head valve, Head Guide, Head sheet & Head seal for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
42Supply only Injector sleeves & Head gasket for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
43Supply only Packing Kit for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
44M&L in repair for head and fuel injector assembly complete all as specified and directed.
45M&L in repair for Turbo assembly complete all as specified and directed.
46M&L for Opening the DG set of 160 KVAincluding cleaning of radiator fins/tubes, repair to any leakage in radiator, replacement of lubricating oil, fuel filters, oil filters, coolant and Air Filter (inner & outer), super bypass filter complete with oiling, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line ,belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note:- Spare parts required for replacement shall be measured and paid separately under respective items.
47M&L for Opening the Piston ring and liner for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
48Supply only valve, Head Guide, Head sheet & Head seal for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
49Supply only Injector sleeves & Head gasket for 160KVA DG Setas per existing make & OEM complete.
50Supply only Packing Kit for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
51M&L in repair for head and fuel injector assembly complete all as specified and directed.
52M&L in repair for turbo assembly complete all as specified and directed.
53M&L for Checking the tappet clearancae and adjustment of valve including replacement of tappet gasket forDG Set 15 to 62.5 KVA complete all as specified and directed.
54M&L for Checking the tappet clearancae and adjustment of valve including replacement of tappet gasket forDG Set 70 to 160 KVA complete all as specified and directed.
55M&L for Checking the tappet clearancae andadjustment of valve including replacement of tappet gasket forDG Set 200 to 450 KVA complete all as specified and directed.
56Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 15 to 62.5 KVA complete all as specified and directed.
57Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 70 to 160 KVA complete all as specified and directed.
58Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 200 to 320 KVA complete all as specified and directed.
59Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 437.5 KVA complete all as specified and directed.
60Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold forfor DG sets 15 to 62.5 KVA including removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
61Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold forfor DG sets 70 to 160 KVA including removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
62Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets 200 to 320 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
63Dismantling the fuel pump from the engine of capacity 15 to 20 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
64Dismantling the fuel pump from the engine of capacity 62.5 to 100 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
65Dismantling the fuel pump from the engine of capacity 160 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
66Dismantling the fuel pump from the Engine of capacity 320 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
67Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 15 to 20 KVA complete all as specified and directed.
68Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 62.5 to 100 KVA complete all as specified and directed.
69Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 160 KVA complete all as specified and directed.
70Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 320 KVA complete all as specified and directed.
71Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 437.5 KVA complete all as specified and directed.
72Taking downradiator from DG set of Capacity 15 to 20 KVA and servicing, cleaning of with suitable reagent, washing throughly, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant required will be measured and paid seperately
73Taking downradiator from DG set of Capacity 62.5 to 100 KVA and servicing, cleaning of with suitable reagent, washing throughly, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant required will be measured and paid seperately
74Taking downradiator from DG set of Capacity 160 KVA and servicing, cleaning of with suitable reagent, washing throughly, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant required will be measured and paid seperately
75Taking downradiator from DG set of Capacity 320 KVA and servicing, cleaning of with suitable reagent, washing throughly, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant required will be measured and paid seperately
76Taking downradiator from DG set of Capacity 437.5 KVA and servicing, cleaning of with suitable reagent, washing throughly, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant required will be measured and paid seperately
77S&F lead acid battery of size 1X 12 Volt , 180 AH of reputed make including charging and taking out old unserviceable complete all as specified and directed.
78Cutting and removal old unserviceable steel sections and sheets metals and fixing of new sheet and steel sections of existing size and shape by necessary gas/arc welding, fixing by nut bolts rivets etc complete all as specified and directed.
79Removing old unserviceable insulating material and fixing of new insulating material of existing size and shape complete all as specified and directed.
80M&L for Spray painting of diesel generating setof capacity 15 to 20 KVA. with one coat of synthetic enamel paint including preparation of old painted surfaces complete all as specified and directed. Note :- Body colour shall be apple green, black for foundation base frame, red for all guards.
81M&L for Spray painting of diesel generating set of capacity 62.5 to 100 KVA with accostic enclosure one coat of synthetic enamel paint including preparation of old painted surfaces complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards
82M&L for Spray painting of diesel generating set of capacity 160 KVA with accostic enclosure one coat of synthetic enamel paint including preparation of old painted surfaces complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards
83M&L for Spray painting of diesel generating set of capacity 320 KVA with accostic enclosure one coat of synthetic enamel paint including preparation of old painted surfaces complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards
84M&L for Spray painting of diesel generating set of capacity 437.5 KVA with accostic enclosure one coat of synthetic enamel paint including preparation of old painted surfaces complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards.
85S&F in replacment AVR system for DG set of capacity 62.5 to 100 KVA as per existing sample complete all as specified and directed.
86S&F in replacment AVR system for DG set of capacity 160 KVA as per existing sample complete all as specified and directed.
87S&F in replacment AVR system for DG set of capacity 320 KVA as per existing sample complete all as specified and directed.
88S&F in replacement turbo chargers repairs kit suitable for DG set 62.5 to 100 KVA complete all as specified and directed.
89S&F in replacement turbo chargers repairs kit suitable for DG set 160 KVA complete all as specified and directed.
90S&F in replacement turbo chargers repairs kit suitable for DG set 200 to 450 KVA complete all as specified and directed.
91S&F in replacement of 3 Pole MCCB, 250 Amp, 50 Hz 415 V with rupturing capacity 36 KA, fixed type complete all as specified and directed.
92S&F in replacement of 3 Pole MCCB, 400 Amp, 50 Hz 415 V with rupturing capacity 36 KA, fixed type complete all as specified and directed.
93S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz 415 V with rupturing capacity 50 KA, fixed type complete all as specified and directed.
94S&F in replacement of 4 Pole MCCB, 250 Amp, 50 Hz 415 V with rupturing capacity 36 KA, fixed type complete all as specified and directed.
95S&F in replacement of 4 Pole MCCB, 400 Amp, 50 Hz 415 V with rupturing capacity 36 KA, fixed type complete all as specified and directed.
96S&F in replacement of 4 Pole MCCB, 630 Amp, 50 Hz 415 V with rupturing capacity 50 KA, fixed type complete all as specified and directed.
97S&F in replacement MCB SP 6 to 32 Amps 10 KA "C" Series,240 V complete all as specified and directed.
98S&F in replacement MCB SPN 40 to 63 Amps 10 KA , "C" Series 240 V complete all as specified and directed.
99S&F in replacement MCB TPN 63 to 100 Amps 10 KA "C" Series 415 Volts complete all as specified and directed.
100S&F in replacementMCCB 3 pole , 125 Amps, 415 Volts, 16 KA breaking capacity and connections including spreader terminals complete all as specified and directed.
101S&Fin in replacement MCCB, 3 Pole ,415 V , 160 Amp with breaking capacity 36 KA including connected accessories, spreader terminals complete all as specified and directed.
102S&F in replacement MCCB, 3 Pole ,415 V , 250 Amp with breaking capacity 36 KA including connected accessories, spreader terminals complete all as specified and directed.
103S&F in replacement MCCB, 3 Pole ,415 V , 350 Amp with breaking capacity 36 KA including connected accessories, spreader terminals complete all as specified and directed.
104Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 400 Sqmm 3.5 core complete all as specified and directed.
105Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
106Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
107Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.
108Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
109Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
110Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
111Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 Sqmm 4 core complete all as specified and directed.
112Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and directed.
113Returning, filling in including spreading,leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
114Removing surplus excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
115Supply and laying burnt brick sub class "B" standard size for cable protection keeping width of the brick parallel to the length of the cable in trenches complete all as specified and directed.
116Supply & spreading clean, dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
117S&F ACP retro sign board of size 1.5x1.1 Meter using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT sub-station details and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on sheet tublar poles 10 ft height of 50 mm dia including PCC 1:2:4 type B-1 for foundation including earth work in any types of soil and fixing of clamps, nuts, bolts, washer etc complete all as specified and directed.
118M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 437.5 KVA, including replacement of oil filter, fuel filter, air filter after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment re-fixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as speciied and directed. Note-Engine oil will be paid separately.
119M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 320 KVA, including replacement of oil filter, fuel filter, air filter after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment re-fixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as speciied and directed. Note-Engine oil will be paid separately.
120M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 160 KVA, including replacement of oil filter, fuel filter, air filter after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment re-fixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as speciied and directed. Note-Engine oil will be paid separately.
121M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 62.5 KVA, including replacement of oil filter, fuel filter, air filter after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment re-fixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as speciied and directed. Note-Engine oil will be paid separately.
122S&F of coolant as per site requirement complete all as specified and directed.
123S&F of engine oil 20 W 40 complete all as specified and directed.
124S&F of sound proof canopy for 437.5 KVA generator with the following acessories :- (a) Platform (frame) size channel 5"x5"2", Length height 20", upper height 8"3" and board 8" - 1 No. (b) Residence silencer. (c) Lock (left-3 & Right-3) - 6 Nos. (d) Paint green. (e) Door right - 3 (both open), back - 1 & front - 1 door. (f) Heinze sudheer type (male/female) - 12 Nos. (g) Rock Bul 96x50. (h) Motor 1.5 HP III Phase (for cooling) - 2 Nos. (i) XL Fan -24" - 2 Nos. (j) CRC sheet (k) Door bidding. (l) Thickness 4 inch. (m) Radiator partition. (n) Jali 4mm.
125S&F in Replacement LED Bollard light 9 Wand 1 mtr long including nesessory excavation and PCC work for fixing complete all as specified and directed.
126S&F in replacement Powder coated pressure die cast aluminium SMD LED street light with heat resistant, toughened glass of capacity 90 Watt complete all as specified and directed.
127S&F in replacement Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 120 Watt complete all as specified and directed.
128S&F in replacement Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 70 Watt complete all as specified and directed.
129S&F in replacement LED flood light with pressure die cast aluminium housing 80 Watt Orion 3.0 Seris completed with connection complete all as specified and directed.
130S&F in replacement LED flood light with pressure die cast aluminium housing 120Watt Orion 3.0 Seris completed with connection complete all as specified and directed.
131M&L for pole painting 9.0 mtr long with a coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from coping to upto height 1.5 mtr of pole alternative way including necessary MES & Pole number to be wriiten in the circular yellow batch on the pole complete all as specified and directed.
132Taking down copper/aluminium point wiring (light, fan, socket or power ) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditionss separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
133M&L for point wiring with 1.5 Sqmm multi stranded PVC insulated unseathed copper conductor cable FRLSin and including PVC concealed conduit of size 20 mm dia for one light point or fan point or bell point controlled by one way switch on plastic laminated sheet 3mm thick using existing MS/CI sunken boxincluding PVC insulated unsheathed 1.5 Sqmm copper conductor FRLS continuous earth wire and connecting with earth dollyincluding necessary cutting chasing for concealing of conduit and making good the distrubed surfaces matching with existing specifications complete all as specified and directed.
134M&L for point wiring with 1.5 Sqmm multi stranded PVC FRLS insulated unseathed copper conductor cable FRLS in and including PVC Casing & caping ofsize 25 mm width for one light point or fan point or bell point controlled by one switchon plastic laminated sheet 3mm thick using existing MS/CI sunken box including PVC insulated unsheathed 1.5 Sqmm copper conductor FRLS continuous earth wire and connecting with earth dolly and making good the distrubed surfaces matching with existing specifications complete all as specified and directed.
135M&L for point wiring for 3 pin socket outlet, 5 amps, independent,with 2.5 Sqmm multi stranded PVC insulated unsheathed copper conductor FRLS cable in and including PVCconduit of size 20 mm dia plasitc laminated sheet 3mm thick using existing MS/CI sunken boxincluding PVC insulated unsheathed 2.5 Sqmm copper FRLSconductor continuous earth wire and connecting withearth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surfaces matching with existing specification complete all as specified and directed.
136M&L for point wiring for 3 pin socket outlet, 5 amps, independent, but below the switch boarch of light points in the same vertical plane with 2.5 Sqmm multi stranded PVC insulated unsheathed copper conductor FRLS cable in and including PVCconduit of size 20 mm dia plasitc laminated sheet 3mm thick using existing MS/CI sunken box including PVC insulated unsheathed 2.5 Sqmm copper FRLSconductor continuous earth wire and connecting withearth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surfaces matching with existing specification complete all as specified and directed.
137M&L in repair sub main wiringwith two single core PVC FRLSinsulated cable 4 Sqmm (Nominal dia) copper conductor multistrand and drawn in and including PVC concealed conduit 20 mm dia ISI marked, 1X4 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note : 3 run of 4 Sqmm cable and one run of PVC conduit shall be measured as one unit (RM).
138M&L in repair sub main wiringwith two single core PVC FRLSinsulated cable 6 Sqmm (Nominal dia) copper conductor multistrand and drawn and including PVC casing/caping 25 mm width ISI marked, 1X6 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note : 3 run of 6 Sqmm cable and one run of casing/caping shall be measured as one unit (RM).
139M&L in repair sub main wiringwith 4 single core PVC FRLSinsulated cable 10 Sqmm (Nominal dia) copper conductor multistrand and drawn and including S&F PVC conduit 40 mm dia ISI marked, 2X 10 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note : 6 run of 10 Sqmm cable and one run of PVC conduit shall be measured as one unit (RM).
140S&F in replacement switch pianotype 6 Amp one way AC 230 volts complete all as specified and directed.
141S&F in replacement switch pianotype 6 Amp two way AC 230 volts complete all as specified and directed.
142S&F in replacementof socket outlet 2in - 1, 6 Amp 5 pin AC 230 volt complete all as specified and directed.
143S&F in replacement switch socket outlet 2in - 1, 6 Amp 5 pin AC 230 volt complete all as specified and directed.
144S&F in replacement switch socketoutlet 2 in 1, 5 pin 5 Amp and 15 Amp multi purpose socket outletAC 230 volt complete all as specified and directed.
145S&F ceiling rose of size 65 x 50mm 3 terminal AC 230 volt complete all as specified and directed.
146S&F in replacement lamp holder angle/ batten holder back light type with base plate suittable for 230 volt complete all as specified and directed.
147S&F in replacement door bell AC 230 voltding dong single phase complete all as specified and directed.
148S&F in repair metal clad socket ,two pin and earth , 20 Amps, 250 Volts suitable for metal clad sheet enclosures complete all as specified and directed.
149S&F in repair metal plug top,two pin and earth , 20 Amps, 250 Volts suitable for metal cladsheet enclosures complete allas specified and directed.
150S&Fin repairof sheet metal enclosures Single pole and neutralwith two pin earth plug and socketwith plug top including single poleMCB 20 Amps complete all as specified and directed.
151S&Fin repairof sheet metal enclosures Triple pole and earth enclosurewith three pin & earth plug with socketcomplete includingtriple poleMCB 32 Amps complete all as specified and directed.
152S&F in repair sheet metal MCCBenclosures for TP/FP MCCBs with inbuilt neutral link for TPN system, IP 30 Protected complete all as specified and directed.
153S&F in repairsof sheet metal enclosures for DBs when MCB to used SPN 8 way double door powder coated factory made with separate neutral and earth links with IP 43 protection, fixed on wall /metal board/wooden board including making all incomming and outgoing connections with suitable copper lugs including disconnecting & taking out old existing enclosure complete all as specified and directed.
154All as per item Ser No 153.00 above but SPN 12 way.
155All as per item Ser No 153.00 above but TPN 4 way.
156All as per item Ser No 153.00 above but TPN 8 way.
157S&F in repair sheet metal enclosure TPNDBs 4 Way 415 Volts, vertical double door type powder coated with busbar neutral link earth rail & din rail, IP-42 Protected, ISI marked for incorporation ofDPX 160MCCB/ ISOLATOR/ RCB etc fixing testing & commissioning complete all as specified and directed.
158Re-fixing of MCB/MCCB any type/any make retrieved from ser Item No. 153.00 to 157.00 complete all as specified and directed.
159S&F decorative recess mounted 35/36 watt, 220 V AC LED luminaire 600 x 600 mm, full output luminaire for modern offices with CRCA powder coated body and new generation high effciency PMMA diffuser to provide soft glare free light complete with driver, holders & LED Lamps suitable formodular / POP/ Gypsum ceiling including disconnecting and taking out old unserviceable light fittings complete all as specified and directed.
160S&F Round shaped recess mounted 15 watt, 220 V AC LED luminaire, full output luminaire for modern offices with CRCA powder coated body and new generation high effciency PMMA diffuser to provide soft glare free light complete with driver, holders & LED Lamps suitable formodular / POP/ Gypsum ceiling including disconnecting and taking out old unserviceable light fittings complete all as specified and directed.
161S&F in replacement LED tubelightrod20 watt240 volts complete all as specified and directed.
162S&F in replacement surface and wall mounted 20 Watt Inverter LEDtube light fittingwith lithium Ion battery with backup time upto 4 hours, driver, holder with extruded aluminium housingwith polycarbonate diffuser input voltage AC 230 V, 50 HZcomplete all as specified and directed.
163S&F ofbulk head luminarie with LED 10 watt lamps Hexagonal shaped with engineering plastic housing and frame with opal PMMA deffuser complete including disconnecting and taking out old unserviceable light fittings complete all as specified and directed.
164S&F in replacement energy saving decorative wall mounting LED Lighting fixtures as mirror light made out of poly corbonate with high output diffuser, 2 feet , 10 watt LED and making connections complete all as specified and directed.
165S&F in repair energy saving decorative wall mounting LED lamp fitting made out of poly corbonate including 1x9/10 watt LED bulb and making connections complete all as specified and directed.
166S&F in repklacement plastic laminated bakelite hylem sheet of size 12 cmx 12 cm , 3mm thick, cut to required sizes and shapes including making holes and necessary cuttings for fitting of switches/ sockets/ regulators complete all as specified and directed.
167All as per Item Ser No. 166.00 above but ofsize 12cm x 20cm.
168All as per Item Ser No. 166.00 above but ofsize 20cm x 25cm
169S&F in repairs PVC Rectangular block for mounting switches, sockets, regulators etc with 3 mm thick plastic laminates sheet cover of size 100x100x50 mm deep complete all as specified and directed.
170All as per Item Ser No. 169.00 above but ofsize 200x150x50 mm.
171S&F in repairsof Modular switch 1 Way 6 Amp, 1 ModuleAC 230 volt complete all as specified and directed.
172S&F in repairsofModular switch 1 Way 16 Amp, 1 ModuleAC 230 volt complete all as specified and directed.
173S&F in repairsofModular socket, 6 A-2/3 pin combined, 2 ModuleAC 230 volt complete all as specified and directed.
174S&F in repairsofModular socket, 6 A/16 Amp -2/3 pin combined, 2 ModuleAC 230 volt complete all as specified and directed.
175S&F in repairsof Modular white cover plate with frame including metal flush box but 4 module complete all as specified and directed.
176S&F in repairsofModular white cover plate with frame including metal flush box but 8module complete all as specified and directed.
177S&F in repairsofModular white cover plate with frame including metal flush box but 12module complete all as specified and directed.
178S&F in repairs forLED domestic bulb 9 Watttype 240 volts complete all as specified and directed.
179Dismantling and strip opening Water Heater 230 volts 25/35/50 Liters capacity 1500 / 2000 watt rating, taking out geyzer assembly elements and other connected accessories, descaling, cleaning of water tank, tubes assembly after repair reassembling ,Electric supply lead 3 core, flexible, PVC insulated and sheathed stranded copper conductor, 1100 Volts grade, size 2.5 Sqmm (nominal area), replacement of unserviceable 3 pin top 15 amp, reinstallation and connecting testing after satisfactorily serving and repairs complete all as specified and directed. Note :- Electric cable 3 core 2.5 Sqmm, Syphon assembly for item No 180.00 will be measured and paid separately under respective item of schedule.
180S&F in repairs of Syphon assembly complete suitable for 25/35 litres water heater ISI marked complete all as specified and directed.
181S&F in repairsof Syphon assembly complete suitable for 50litres water heater ISI marked complete all as specified and directed.
182S&F in repairsof PVC connection heat resistant24"" long ISI marked complete all as specified and directed.
183S&F in repairs of sheet metal bottom cover having two halves circle complete all as specified and directed.
184S&F in repairs of Thermostat 35º C to 75º C of ISI marked complete all as specified and directed.
185S&F in repairs of Indicating lamp (LED ) red or green any shape and size matching to existing geyser complete all as specified and directed.
186S&F in repairs of Heating Element required size and shape, 2000 watt ISI marked, suitable to 25/35/50 litre water heater complete all as specified and directed.
187S&F in repair gasket packing set suitable for 25/35/50 litres water heater complete all as specified and directed.
188S&F in repairsof glass wool superior quality for geyser including removing inner tank and refixing properly complete all as specified and directed.
189S&F 3 core, flexible, PVC insulated and round sheathed stranded copper conductor, 1100 Volts grade, size 2.5 Sqmm (nominal area) ISI marked complete all as specified and directed.
190M&L in repairs of PVC insulated twin core flexible copper cable of size 40/76 Guage complete all as specified and directed.
191S&F installation, testing and commissioning in repair of pressure die-cast aluminiumhousing with high power LED building security light fitting with IP-66 , 1x 25 Watt , fixed in position with and including 40 mm dia light grade GI Pipe made to shape not less then 1.2 Mtr long for mounting fitting with and including suitable size duly painted MS FI 40 x6mm clamps with nut and bolts, washers making electrical connection with and including three core 16/0.20 mm copper conductor flexible cable from connector to fitting complete all as specified and directed.
192M&L in replacement for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron wire 4 mm diaby means of Copper nuts, bolts and washers.GI wire shall be laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor)with following complete all as specified shown in electrical plate No 3 of SSR Part-I & testing on completion of the following:- (a)GI wire of size 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick reinforced with 8 mm dia TMT bars 75 mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.