Tender For Supply Installation Testing And Commissioning Of Fixtures, Cabling Work, Bbt Work, Electrical Sub Station And External Lighting Work At Medical College, Karauli, karauli-Rajasthan

Rajasthan State Road Development And Construction Corporation Limited has published Tender For Supply Installation Testing And Commissioning Of Fixtures, Cabling Work, Bbt Work, Electrical Sub Station And External Lighting Work At Medical College, Karauli. Submission Date for this Tender is 04-04-2023. Electrification Work Tenders in karauli Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36893614
Corrigendum : Tender For Supply Installation Testing And Commissioning Of Fixtures, Cabling Work, Bbt Work, Electrical Sub Station And External Lighting Work At Medical College, Karauli
Open Tender
Indian
Rajasthan
karauli
04-04-2023

Tender Details

Tender For Supply Installation Testing And Commissioning Of Fixtures, Cabling Work, Bbt Work, Electrical Sub Station And External Lighting Work At Medical College, Karauli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Apr-2023 Engineers cost 01042023 Other 04-04-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 1598000.0 /-
Tender Value
INR 7.99 Crore /-

BOQ Items

Name of Work : -SITC of Fixtures, Cabling work, BBT Work, Electrical Substation & External Lighting work at Medical College Kaurali
Sl. No. Item Description
1Supply installation testing & Commissioning of Copper wound distribution Transformerof following ratingand % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooledlosses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core designincluding standardaccessories like conservator with prismaticoillevelgauge , silica gel breather,Bucholz relay,pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box,LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ),temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device,Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test inOEM"s own lab shall be witnessed by Department engineer Physically.
2Transformer shall be tested from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in charge. MAKE:- Uttam Bharat / Danish / RTS / United / Voltamp / Intra.
3630 KVA with % Impedance 4.5
41000 KVA with % Impedance 5.0
5SITC of 11 KV, 400/630 A, 20kA / 3 sec, Out door,Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earthing switch, mechanical ON / OFF /Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, Shunt trip coil, Anti reflex operating handle, right angle boots etc. as required.
6SITC of Silent DG Set (As per latest CPCB emissionnorms) complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown). Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding), electronic / Mechanical governor, Manual & electric Start ,Batteries,Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mmCRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with 100mm thick glass wool (96Kg/m3)/Foam. as per IS 8183 the doors of 100 mm thick and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/ opening are sealed with neoprene/EPDN gaskets.
7The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigrade. All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dBA at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :GRP-1
8Radiator Cooled & Turbo Charged /AC
9380 KVA at 0.8 pf 415V 50Hz 3-?
10160 KVA at 0.8 pf 415V 50Hz 3-?
11Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applicationsincludingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool (64 kg/m3 density) & 24 SWG aluminium sheet claddings etc complete as required.
12200 mm dia
13SITC of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter , Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:
14PLC Based:
15320 to 500 KVA
1680 to 160 KVA
17SITC of ceiling suspended / wall mounted Factory fabricated & site assembled sandwich type TPNAluminium bus trunking including the cost of Enclosure ( 1.5 mm thick) , run components, expansion joints, provision for end feed units, tap off box , connection components , end covers , fixing bracket & accessories as required of following rating & specifications: Rated Insulation Voltage: 660V, Rated Frequency:50Hz, Rated Operating Voltage:415 / 440V, Short Time Ratingt: 35 KA for 1 sec, IP classification:IP 54 / 55, two no. GI earthing strip of 50 %ofPhase conductor
18100 Amp. to 400 Amp.
19500 Amp. to 630 Amp.
20Supply & Installation of TAP Off unit enclosure (w/o MCCB / ACB ) of following capacityMCCB / ACB & suitable forsandwich typeAluminiumbus trunkingas required.
21Up to 125 Amp. MCCB
22160 Amp.to 250 Amp. MCCB
23Supply & Installation of End Feed unit enclosure (w/o MCCB / ACB ) of following capacityMCCB / ACB & suitable forsandwich typeAluminiumbus trunkingas required.
24300 Amp.to 400 Amp. MCCB
25500 Amp.to630 Amp. MCCB
26P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. Group -1 Makes : Havell"s / Polycab / KEI / RR Kabel / Gemscab ( Cable to be laid in Existing Pipe/ Masonary Duct / Cable Tray ). Unarmoured
2735.0 Sq.mm x 4 core
28Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
294 x 35.0 sq.mm
30P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size.
313 core 300.0 Sq.mm
32Providing & making heat shrinkable type indoor/outdoor/straight through terminations/joint kit of Group1 and approved make suitable for XLPE insulated 11 KV / 33 KV cable, with required components, prepration of cable ends,testing etc. as required of following sizes .
3311 KV End Termination Kit Indoor type
343 core 240/300 Sq.mm
3511 KV End Termination Kit Outdoor type
363 core 240/300 Sq.mm
3711 KV Straight Through JointKit
383 core 240/300 Sq.mm
39Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
40Electrolytic grade Aluminium bus bar
41SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required .
42from 200 / 5 to 400/5Ratio , 10 VA , class 1 accuracy
43from 500 / 5 to 1600/5 Ratio , 15 VA ,class 1 accuracy
44SF of110/220 V, LED (22.5 mm dia ) Indicatinglamp with integral circuit, terminal block, including connection etc. as required.
45Red/yellow/Green colour
46Blue colour
47SITC of Fixed /Draw out type 4 pole Air Circuit Breaker conforming to IS 60947 P - 2 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault andmicroprocessor based release withseparate LED indication for each type of fault ,LCDdisplay , Thermal memoryat least 4NO & 4NC auxiliary contacts safety shutter and fault position acknowledgement mechanism . type ACB shall have separate indication for service, test, isolation, maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ), Uimp - 12 KV, including making connectionsetc. as required.Make:- ABB/ Legrand /L&T /Schinder
48Draw out type ( Motorised charging type )
491600 A Rating ,50 / 65kA
501250 A Rating ,50kA
51800 A Rating, 50kA
52Draw out type (Manual spring charged)
531250 A Rating ,50kA
54800 A Rating, 50kA
551000 A Rating , 50kA
56SITC of Fixed /Draw out type 3 pole Air Circuit Breaker conforming to IS 60947 P - 2 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault andmicroprocessor based release withseparate LED indication for each type of fault ,LCDdisplay , Thermal memoryat least 4NO & 4NC auxiliary contacts safety shutter and fault position acknowledgement mechanism . type ACB shall have separate indication for service, test, isolation, maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , Uimp - 12 KV, including making connectionsetc. as required.
57Draw out type (Manual spring charged)
58800 A Rating, 50kA
59SITC of quick make and quick break3 pole current limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with frontface and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push( test) to trip, including making connections with lugs & spreaders,etc. as required.
60With Thermal Magnetic release
61630 Amp , 35/50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
62up to 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
63250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
64SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required.
65Heavy duty Three phase 440 V , 50 Hz capacitor (Bank)
66SITC of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR,metering facility as required.
6712 to 14 stage
68sensitivity up to 50 milli Amp
69P & F of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
70up to 6 KVAR
717 to 10 KVAR
7211 to 20 KVAR
7350 KVAR
74P & F of Multy functionmeter with LCD/ LED display capable of measuringelectrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect.
75S & F of Electricalinsulating rubber mattsconfirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required.
7611 KV,2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV
77P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. Group-1.
786.4 mm thick
79P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp-AI
80Single pole MCB
816 A to 32 A rating
82Triple pole MCB
836 A to 32 A rating
8440 A 63 A rating
85Four pole MCB
866 A to 32 A rating
8740 A 63 A rating
88P&F of removable Voltage surge protection device (surge arrester) for protection against transient over voltage (8/20 micro -seconds) and to run current waves to ground, making connection, testing etc. as required. ( Imax=40 kA, Up= 1.2kV, Uc=275 volts )
89Triple pole & neutral
90P & F Cam operated rotary switches on existing panel with 2 way and off position
91Two pole
9216 A
93SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required of group 01.
94With Thermal Magnetic release
95up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
96up to 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
97160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
98200 Amp ,25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
99250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
100With Microprocessor based release
101400 Amp ,35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
102630 Amp , 35/50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
103P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required. Group-1 of size.
1046.0 Sq.mm
1054 core
10616.0 Sq.mm
1074 core
10835.0 Sq.mm
1093.5 core
11070.0 Sq,mm
1113.5 core
112120.0 Sq,mm
1133.5 core
114185.0 Sq,mm
1153.5 core
116240.0 Sq.mm
1173.5 core
118300.0 Sq,mm
1193.5 core
120Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. Group-1 of size.
1214 x 6.0 sq.mm
1224 x 10.0 sq.mm
1233.5 x 35.0 sq.mm
1243.5 x 70.0 sq.mm
1253.5 x 120.0 sq.mm
1263.5 x 185.0 sq.mm
1273.5 x 240.0 sq.mm
1283.5 x 300.0 sq.mm
129Supply and fixing of following accessories for Air circuit breakers. Group 1
130Shunt Trip Release
131Under Voltage Release
132Maintenance free Gel EarthingwithPipe in pipe / Pipein striptechnologyfilled with anti corrosive conductive compound ( CPRI Tested )below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineralfillingcompound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone) and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.
133With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating
134GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip
135GI pipe 3000 mm long, 80 / 40 mm, Terminal 14 mm GI Strip
136S & Laying following size earth wire / stripin horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. Group-1.
13732mm x6mm G.I. ( Hot Dipped) Strip
13850mm x 6mm G.I. ( Hot Dipped) Strip
13950mm x 6mm copper strip
1408 SWG G.I. ( Hot Dipped) Wire
141Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required.
142Making hole in stone masonary/ RCC with core cutter for accomodating cables/earthing strip and making same with cement plasterincludingusing solvent to make water proof
14350mm to 150mm
144Supply and fixing of following accessories for MCCB
145Extended Rotary Handle
146P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
1472.5 Sq.mm
14810 core
149Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.
15050mm x 50mm x 3.15mm
151P & F of 4 star ratedvertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out,Dual indicating lamps for power supply and thermostat,PUF insulation, Pressure relase valve,fusible plug etc. as required held in position with 4 no. rack bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top,including making inlet,outlet heavy gauge C.P./ Flexible alloyconnection,testing etc. as required.
15215 Ltr.
15325 Ltr.
15435 Ltr.
155SITC of self contained drinking water cooler with energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank, stainless steel water tray,minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted platform. Complete in all respect of the following capacity
156Cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
157SITC ofRO water system with Filtration stage = Particulate filter-Membrane life enhancer filter - sediment filter - Pre carbon filter -RO Membrane filter - Post carbon filter,Input power Rating - 230 V AC , 50 HZ, Percentage of Rejection TDS - 90% or better having following Features (a) Double purification by RO with ESS or latest technology with TDS indicator (b).Spin welded RO Membrane Housing to prevent tempering (c). Push fit components for leak proof performance (d). Fully automatic operation with auto start and auto off (e). SS construction for corrosion free lifespan (f). Equally suitable for water from all bore wells,,overhead storage tanks,water tankers and even municipal taps (g) RO Membrane Flushing - Auto Flush @ Every Start , Every Stop and every One Hourof working for one minute. complete in all respect with following capacity. Approved Make:Eureka forbes, Kent, AU Smith, Ion Exchange, pentair.
158Purification capacity- 50 LPH,Duty Cycle 270-500 liters/day,
159P & F of 36Watt IP20 LED 2"X2" fixture, Recessed/Surface type, of thickness not less then 50 mm having efficancy of not lessthan 100 Lumen/watt, made out from CRCA housing and with high purity/transmisvity duffuser for uniform light distribution high efficiency driver electronics and in compliance to IEC standard (integral with light fixtures) life time of more than 50000 burning hours, CCT 6000 K (minimum), CRI> 80, driver maintaining PF >0.90
160P & Fof IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of = 100 lm / watt andlife time of minimum35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K/ 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be of CE complianed.
161Surface Mounting
162LED Downlight 12 W
163LED Downlight 18/20W
164P&F on load change over switch, front handle operated, four pole 415 V conforming to IS:13947 P-III including connections , testing etc. as required in the following rating:
165Open execution type
166125 A
167200 A
168Supply, Fabricating & installing following sizes of powder coatedperforated M.S. cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders, fastners, supports etc. as required.
169300mm x 50mm x 1.6mm
170450mm x 50mm x 2.0mm
171Add extra @15% if GI Cable tray used in place of MS Cable tray
172SITC of high mast lighting system (as per CP3-TR7/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm, mast head frame assembly with full cover, aviation obstructionlights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, outdoor type control panel for auto on / off, reverse / forward motor operationand CC foundationof M - 25 grade complete as required. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. (See table E - 13 for specs.)
17320.0 Mtr Hm (in 2 section)
174P & F ofIP-65 protected high power LED flood light system with Pressure diecast aluminium housing , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED fixturesupplied with pre wired cable of 1 mtr. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards/BIS certified. The System level Luminaire efficacy >=100with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOULmake is to be used . LED Driver Input Voltage AC 110 to 270 V AC with Auto resetting Safety Cut-off. Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% ,Control Gear Integral Design, THD(I) <10%,. Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10KV external in 80W onwards,Humidity 10% to 90% RH Working Temp -20C to 50C . LED Luminaire Specifications: Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintenance.Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed of
175High Power LED Flood Light 150W
176Supply and erection of GI Octagonal / Conical pole of following length and dimension as per table E-10 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.
177Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table E - 10 for specs.)
1787 Mtr.
179Supply, Erection and Fixing of hot dipped galvanised Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles
180Single arm overhang
181P & F of IP 65 protected LED Street Light fixture 70-75 Watt with surge protection device 10KA) applicable for area lighting with extruded pressure diecast aluminium housing, system lumens efficacy of 100 lm/watt minimum, toughened glass with diffuser, suitable lenses on LED, 240V,50 Hz of High Power LED lamps supplied with pre-wired cable of 1 mtr. Integrated Driver shall be high efficiency having efficiency >85% and in compliance to IEC standards System life of 50,000 Burning Hours, CRI >80,PF>0.90 at full load, CCT 5700-6500 I( fas per direction of Engineer incharge]. Fixture shall be CE compliance
182S & F of Street light bracket made out from following size of " B "class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.
18340 mm Dia.
184Providing and fixing of IP 65 protectd Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect.
185125 mm X 200 mm X 122 mm
186P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make.Outer Dia. / Inner dia.
18790 / 76 mm
188120 / 103 mm
189P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required.
1902.5 Sq.mm 3 core flat / Round (Gr - I)
191P & F ofac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required. Group-1.
1924 pole Power contactorswith following AC 1 Rating
19363 Amp
194600 Amp
195P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required. Group-1
196One day reserve (mechanical type )
197P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. Group-1.
1986.4 mm thick
199P & F lightning conductor finial made out of 25 mm dia.,300 mm long G.I. tube having single prong at top with 85 mm dia., 3 m thick G.I. base plate including holes etc. complete as required.
200P & F of Early streamer Emission type lightning arrester on GI mast with air terminal configured as spheroid which is comprised ofseparate electrically isolated 4 panels surrounding an earthed central finial, the terminal shall be tested by CPRI for impulse current of 45 kA ( 8 / 20 Sec ) with 5 positive & 5 negative impulse, the arrester having following protection radius at level 1
20160 - 79 Mtr.
20230 - 48 Mtr.
203S & Laying of down conductor of 70 Sq.mm single core insulated flexible copper cable with accessories as required.
204NON BSR
205Supply, installation, testing and commissioning of INDOOR type, 11 KV switch panel board fabricated out of minimum 2 mm thick sheet steelas per specifications. The panel shall be complete with cable termination arrangementfor incoming and outgoing with 1x 3C x 300 Sqmm XLPE 11 KV cable and required rating copper bus bar arrangement .The panel shall comprise of the following:
2064 Nos 11 KV, 25 kA for 3 sec (1 I/C and 3 O/C)630 A, horizontal drawout type VCB/SF6 breaker with motorised spring charge closing mechanism with antipumpingprotection and trip free features , motor voltage 240V AC and tripping / closing coil voltage , 24V DC and VCB /SF6 breaker complete with 3 NO + 3 NC auxillarycontact as sparecomplete with following of ( Make: ABB/ Schneider/ Siemens).
2071NOS. INCOMING , 3 Nos. 11 KV, 25 kA for 3 sec, 630 A, horizontal drawout type VCB/SF6 breaker with motorised spring charge closing mechanism with antipumpingprotection and trip free features ,motor voltage 230V AC and tripping / closing coil voltage , 24V DC and VCB /SF6 breaker complete with 3 NO + 3 NC auxillarycontact as sparecomplete with following:
2081 no. 240V AC spring charge motor.
2091 no. 24V DC shunt trip coil.
2103 set of 400-150/5-5A, core 1, class 0.5 accuracy, 5VA current transformer (cast resin) for metering, core 2 class 5P10, 5VA accuracy current transformer (cast resin) for protection.
2111 no Numerical non directional IDMT 3 O/C + 1 E/F protection relay for each breaker,1 no. master trip relay for each breaker,1 no. Trip circuit supervision relay for each breaker,1 no. Antipumping relay for each breaker.
2121 no. breaker control switch : (TNC) for each breaker,1 set of phase indication lamp (LED type) for each breaker,1 no. threepin socket + switch (240 V) for each breaker.
2131 set of circuit breaker ON/OFF/Auto trip / Spring charged/Trip circuit healthy indicating/ SF6 gas pressure indication lamp (LED type) for each breaker.
2141 no. 60W 230 V anti condensation space heater with thermostat with heater ON/Off switch for each breaker in breaker comprment & cable compartment.
2151 set of 800A 11kV rectangular electrolytic grade colour coded and sleeved copper busbars for each breaker.
216Motor On / Off togle switch for each breaker,Yellow/white Puh Button for Alarm Accept/Reset for each breaker,Black Push Button for Trip Circuit Check for each breaker.
217Suitable rating MCB for AC / DC supply control for each breaker.
218Door Lamp with Switch for each breaker.
219Electrical & mechanical interlocking of 2 nos outgoing breaker to prevent the short circuit between both breaker for 2 sets of outgoing breaker.
220HT Panel described above & as per specification.
221Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
222M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
223Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed:
224Ordinary rock
225SITC of LED batten with reliable and robust CRCA housing structure, CRI>80, System Lumen Output of 4100 lm with a System Wattage of not more than 40 Watts and a system efficacy of 100 lm/Watts, Lifetime of 50,000 burning hours @L70, Wide Operating Voltage Range of 140V-270V, Color Temperature Options of 5700K -6500K, Power Factor = 0.95, THD<10% with Short Circuit and over voltage cut off etc as required.LM 79 and LM80 report has to be submitted for documentary verification of above Specifications. (Make:- Phillips,Crompton , Wipro, Trilux, Havells)
226Supplying, installation, testing & commissioning of 9-10 watt 3000K mirror light all accessories i/c connections with 3 x 1.5 sq.mm PVC insulated FR copper conductor cable etc. as reqd. (Make Phillips, Havells, Crompton , Wipro, Trilux)
227Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
228Threephase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS
229Supply and erection of GI Octagonal / Conical pole of following length and dimension as per table E-10 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.
230Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table E - 10 for specs.) Makes :- As per BSR Grp-1
2314 mtr.
232Supply & installation of cable identification plates duly secured to cables for identification suitable for cable sizes taken in the BOQ.
233P & F of ventilating fans with thermostate and ON/OFF selector switch including making connection, testing etc. as required.
234100 mm sweep
235S & Laying following size earth wire/strip of 1.5 mtr length for connecting earth strip of DG netural terminal including riveting, soldering, saddles, making connection etc. as required.
23650mm x 6mm flexible copper strip
237SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of2 mm thick CRCA sheet , required hardware,duly powder painted in required shade after rinsing . The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel, door handle, hinged door with locking arrangement for equipment/switchgear . Side walls and cable alley compartments having bolted type doors with detachable extension type structure. (only outer area on all sides shall be measured ) Make : Engineers & Engineers /Milestone / Advance Panels /Tricolite /ZENEIA/ Adlec
238P & F of IP 65 protected LED Post-Top-Light system with complete Die casthousing, poycarbonate diffuser, Maximum 40 watt,Mininum Lumnes 3600 Watt 220-240V, 50Hz (integrated Driver), LED lamps supplied with pre-wired cable of 1 mtr. Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards (Integral with light fixture).system life of 50000 Burning Hours with 70% of initial Lumens maintained.Light output in Cool white or Warm White Colour as per engineers choice. Fixtures shall be CEcompliance.Make :- Philips/Wipro/Crompton
239Supply, Installation, Testing and balancing of powder coated /Anodised extruded aluminium construction inlet fixed single air louvers with bird screenfor Exhaust air of size upto 2.0 sqft area, Installation has been done on the Exhaust Fanof make Systemair / Ravistar / Trox/MetalJoint/Airflow.
240P & F of Surface mounting LED bulk head fitting, efficacy >=100 lumens /watt  total Lumen  output  not  less  than  1000,  CRI>80  and  CCT=4000/6500 K(as reqd.), with inbuilt LED Driver and IP-65 & IK08 and better rated with pressure die cast aluminum housing & diffused polycarbonate diffuser complete as required.Make PHILIPS, Havells, Crompton , Wipro)
241P & FDouble ball bearing and with sturdy mesh guard metal body ,3 numbers metal blales oscillating tye wall mounting Fan, including fixing with anchor bolts, adjustable upward and downward tilt mechanism, noise level should <=75 db, power consumption <=120 watts, motor protection through thermal overload protection device, 3 speed regulator making connection testing etc. as required. Make:- Havells,Wipro,Crompton,Orient
242450 mm sweep With three speed regulator
243Supply and laying in ISI marked RCC hume pipe NP 3 as per IS - 458-1988 with coller etc including excavation of trench of 1.2 mtr depth & refilling the same after covering the pipe with 300 cement concerete mixture of 50 mm below the pipe, 150 mm both side of pipe and 300 mm above the pipe complete in all respect as per specification. ( payment of CC mixture will be made in seperate CC item of the BOQ as per measurement)
244200 mm dia
245300 mm dia