Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #36892363

Tender For Procurement Of Laboratory Double Beam Uv-Visible Spectrophotometer Under Cwa(W&S)Ii Division

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Mar 2023
0 days left
EMD
31200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Procurement Of Laboratory Double Beam Uv-Visible Spectrophotometer Under Cwa(Wns)Ii Division. , The Spectrophotometer Will Be Dual Beam (Viz Uv-Visible) Operation And With The Reference Cell Position For Kinetics Application. It Will Mandatorily Have 8-Cell Carousel. The Spectrophotometer Must Have Room-Light Resistance Allowing Lid-Open Operation For Improved Speed And Convenience. The Spectrophotometer Will Have Option Of Automated Cell Changers And Cell Holders, Sippers, And Fibre Optic Probes For Measurements Outside Of The Sample Compartment. It Must Accommodate High Throughput Measurements And Temperature Control. The Spectrophotometer Will Have Following Features: 1. Spectrophotometer Will Be Double Beam (Uv- Visible)/Reference Cell. 2. It Will Have High Resolution Touch Screen User Interface. The Spectrophotometer Must Be Capable Of Operating Through Computer Also. 3. There Will Be 8-Position Cell Changer With Switchable Turret. 4. It Will Have Onboard Methods, Reporting And Data Export. 5. It Will Be Networking Capable And Will Have Wi-Fi Adaptor. 6. It Is Capable Of Open-Lid Operation. 7. There Will Be Room Light Resistance. 8. It Will Have Sipper (Optional). 9. It Must Accommodate Cells Upto 100Mm Path Length. 10. It Must Have Optional Facility For 4-Position Cell Changer (Long Path Cells) And Peltier- Thermostat Single Cell Holder (20°C-60°C). Detector Type• Dual Silicon Photodiodes. Display• 7- Inch Colour Touch Screen, High Definition, 800X1280 Pixels. Photo-Metric Accuracy Instrument • ±0.002A At 0.5A • ±0.004A At 1.0A • ±0.008A At 2.0A Wavelength Accuracy • ±0.5 Nm Baseline Flatness • ±0.002A Compartments• 8-Position Cell Changer (Standard) Also Accommodates (Optional): • Peltier Thermostat Cell Holder (20-60 °C) • Sipper Accessory (Optional) Drift • (At 500 Nm After 1 Hour Warmup) <0.0005A/Hr Electrical Requirements • External Ac To Dc Converter. Voltage And Frequency (Hz) Selected Automatically, 100–240 Volts, 50–60 Hz. Keypad • Touchscreen Lamp • Xenon Flash Lamp (>5 Years Typical, 3 Years Guaranteed) Noise • (Rms At 500 Nm 60 Consecutive Measurements) • =0.00020A At 0A At 260 And 500 Nm • =0.00030A At 1A At 260 And 500 Nm • =0.00040A At 2A At 260 And 500 Nm Optical Design • Double Beam Photometric Display • -3A To +5A Photometric Range • –2A To +3.5A Photometric Repeatability • ±0.001A At 1A Measured At 1.0A At 546 Nm Spectral Bandwidth • 2 Nm Stray Light • < 1.0%T 198 Nm (Kcl) ,<0.05%T At 220 Nm (Naci), <0.03%T At 340 Nm (Nano2) Wavelength Data Interval • 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm Wavelength Range • 190 Nm – 1100 Nm Wavelength Repeatability • < ±0.2 Nm Wavelength Scan Speed • Slow, Medium And Fast - Up To 1600 Nm/Min Printer • Capable To Connect With Printer Computer Operation • The Spectrophotometer Can Be Operated From Compatible Computer And Software. Computer And Operational Software To Run Spectrophotometer Will Be A Part Of The Spectrophotometer. Connections • Single Usb-A Supports Flash Memory Devices For Method And Data Storage • Duplex Usb-A On Side Supports Connection To A Computer Running Optional Remote Control Software, Keyboard, Mouse • Export Data To Network Or Pc Via Usb, Ethernet, Or Wi-Fi Usb Adaptor, Available • Print Via Usb, Ethernet Or Wi-Fi Usb Adaptor Available Warranty • 3 Years Make:- Hach/Thermo Fisher Scientific/Agilent/Perkin Elmer/Wtw/Lovibond.

BOQ

Name of Work: Procurement of Laboratory Double Beam UV-Visible Spectrophotometer under CWA(W&S)II Division.
Sl. No. Item Description
1The Spectrophotometer will be dual beam (viz UV-Visible) operation and with the reference cell position for Kinetics application. It will mandatorily have 8-cell carousel. The Spectrophotometer must have room-light resistance allowing lid-open operation for improved speed and convenience.The Spectrophotometer will have option of automated cell changers and cell holders, sippers, and fibre optic probes for measurements outside of the sample compartment. It must accommodate high throughput measurements and temperature control.The Spectrophotometer will have following features:1. Spectrophotometer will be Double Beam (UV- Visible)/Reference Cell.2. It will have High Resolution touch screen user interface. The Spectrophotometer must be capable of operating through computer also.3. There will be 8-position cell changer with switchable turret.4. It will have onboard methods, reporting and data export.5. It will be networking capable and will have Wi-Fi adaptor.6. It is capable of open-lid operation.7. There will be room light resistance.8. It will have sipper (optional).9. It must accommodate cells upto 100mm path length.10. It must have optional facility for 4-position cell changer (long path cells) and Peltier- thermostat single cell holder (20°C-60°C).Detector Type• Dual Silicon Photodiodes.Display• 7- inch colour touch screen, high definition, 800x1280 pixels.Photo-Metric Accuracy instrument• ±0.002A at 0.5A• ±0.004A at 1.0A• ±0.008A at 2.0AWavelength Accuracy • ±0.5 nmBaseline Flatness • ±0.002ACompartments• 8-position cell changer (standard)Also accommodates (optional):• Peltier thermostat cell holder (20-60 °C)• Sipper accessory (OPTIONAL)Drift • (At 500 nm after 1 hour warmup) <0.0005A/HrElectrical Requirements • External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz.Keypad • TouchscreenLamp • Xenon Flash Lamp (>5 years typical, 3 years guaranteed)Noise • (RMS at 500 nm 60 consecutive measurements)• =0.00020A at 0A at 260 and 500 nm• =0.00030A at 1A at 260 and 500 nm• =0.00040A at 2A at 260 and 500 nmOptical Design • Double BeamPhotometric Display • -3A to +5APhotometric Range • –2A to +3.5APhotometric Repeatability • ±0.001A at 1A measured at 1.0A at 546 nmSpectral Bandwidth • 2 nmStray Light • < 1.0%T 198 nm (KCl) ,<0.05%T at 220 nm (NacI), <0.03%T at 340 nm (NaNO2)Wavelength Data Interval • 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nmWavelength Range • 190 nm – 1100 nmWavelength Repeatability • < ±0.2 nmWavelength Scan Speed • Slow, medium and fast - up to 1600 nm/minPrinter • Capable to connect with printerComputer operation • The spectrophotometer can be operated from compatible computer and software. Computer and operational software to run Spectrophotometer will be a part of the spectrophotometer.Connections • Single USB-A supports flash memory devices for method and data storage• Duplex USB-A on side supports connection to a Computer running optional remote control software, keyboard, mouse• Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available• Print via USB, Ethernet or Wi-Fi USB adaptor availableWarranty • 3 yearsMake:- Hach/Thermo fisher scientific/Agilent/Perkin Elmer/WTW/Lovibond.

AI Tender Summary

OUR REF NO 36892363
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 27-03-2023
Authority
Authority Name Delhi Jal Board
Work Description Procurement Of Laboratory Double Beam Uv-Visible Spectrophotometer Under Cwa(Wns)Ii Division. , The Spectrophotometer Will Be Dual Beam (Viz Uv-Visible) Operation And With The Reference Cell Position For Kinetics Application. It Will Mandatorily Have 8-Cell Carousel. The Spectrophotometer Must Have Room-Light Resistance Allowing Lid-Open Operation For Improved Speed And Convenience. The Spectrophotometer Will Have Option Of Automated Cell Changers And Cell Holders, Sippers, And Fibre Optic Probes For Measurements Outside Of The Sample Compartment. It Must Accommodate High Throughput Measurements And Temperature Control. The Spectrophotometer Will Have Following Features: 1. Spectrophotometer Will Be Double Beam (Uv- Visible)/Reference Cell. 2. It Will Have High Resolution Touch Screen User Interface. The Spectrophotometer Must Be Capable Of Operating Through Computer Also. 3. There Will Be 8-Position Cell Changer With Switchable Turret. 4. It Will Have Onboard Methods, Reporting And Data Export. 5. It Will Be Networking Capable And Will Have Wi-Fi Adaptor. 6. It Is Capable Of Open-Lid Operation. 7. There Will Be Room Light Resistance. 8. It Will Have Sipper (Optional). 9. It Must Accommodate Cells Upto 100Mm Path Length. 10. It Must Have Optional Facility For 4-Position Cell Changer (Long Path Cells) And Peltier- Thermostat Single Cell Holder (20°C-60°C). Detector Type• Dual Silicon Photodiodes. Display• 7- Inch Colour Touch Screen, High Definition, 800X1280 Pixels. Photo-Metric Accuracy Instrument • ±0.002A At 0.5A • ±0.004A At 1.0A • ±0.008A At 2.0A Wavelength Accuracy • ±0.5 Nm Baseline Flatness • ±0.002A Compartments• 8-Position Cell Changer (Standard) Also Accommodates (Optional): • Peltier Thermostat Cell Holder (20-60 °C) • Sipper Accessory (Optional) Drift • (At 500 Nm After 1 Hour Warmup) <0.0005A/Hr Electrical Requirements • External Ac To Dc Converter. Voltage And Frequency (Hz) Selected Automatically, 100–240 Volts, 50–60 Hz. Keypad • Touchscreen Lamp • Xenon Flash Lamp (>5 Years Typical, 3 Years Guaranteed) Noise • (Rms At 500 Nm 60 Consecutive Measurements) • =0.00020A At 0A At 260 And 500 Nm • =0.00030A At 1A At 260 And 500 Nm • =0.00040A At 2A At 260 And 500 Nm Optical Design • Double Beam Photometric Display • -3A To +5A Photometric Range • –2A To +3.5A Photometric Repeatability • ±0.001A At 1A Measured At 1.0A At 546 Nm Spectral Bandwidth • 2 Nm Stray Light • < 1.0%T 198 Nm (Kcl) ,<0.05%T At 220 Nm (Naci), <0.03%T At 340 Nm (Nano2) Wavelength Data Interval • 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm Wavelength Range • 190 Nm – 1100 Nm Wavelength Repeatability • < ±0.2 Nm Wavelength Scan Speed • Slow, Medium And Fast - Up To 1600 Nm/Min Printer • Capable To Connect With Printer Computer Operation • The Spectrophotometer Can Be Operated From Compatible Computer And Software. Computer And Operational Software To Run Spectrophotometer Will Be A Part Of The Spectrophotometer. Connections • Single Usb-A Supports Flash Memory Devices For Method And Data Storage • Duplex Usb-A On Side Supports Connection To A Computer Running Optional Remote Control Software, Keyboard, Mouse • Export Data To Network Or Pc Via Usb, Ethernet, Or Wi-Fi Usb Adaptor, Available • Print Via Usb, Ethernet Or Wi-Fi Usb Adaptor Available Warranty • 3 Years Make:- Hach/Thermo Fisher Scientific/Agilent/Perkin Elmer/Wtw/Lovibond.
Basic Detail
Tender No NIT No. 17(22-23)/CWA(WnS)II
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 20 Mar 2023
Submission Date 27 Mar 2023
Open Date 27 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 31200
Exemption Not Available
Document List
fc216a14-42ce-412b-ac58-5050a1626c4c.html
BOQ_311245.xls
NIT17doc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 20, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 27, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

fc216a14-42ce-412b-ac58-5050a1626c4c.html

xls

BOQ_311245.xls

pdf

NIT17doc.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders