Tender For Providing And Fixing Of 01 No. 500 Kva Distribution Transformer And Its Accessories At Babyal Link Drain Pump House In Syl W/S Division Ambala, ambala-Haryana

Irrigation Department has published Tender For Providing And Fixing Of 01 No. 500 Kva Distribution Transformer And Its Accessories At Babyal Link Drain Pump House In Syl W/S Division Ambala. Submission Date for this Tender is 27-03-2023. Distribution Transformer Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

36891666
Tender For Providing And Fixing Of 01 No. 500 Kva Distribution Transformer And Its Accessories At Babyal Link Drain Pump House In Syl W/S Division Ambala
Open Tender
Indian
Haryana
ambala
27-03-2023

Tender Details

Providing And Fixing Of 01 No. 500 Kva Distribution Transformer And Its Accessories At Babyal Link Drain Pump House In Syl W / S Division Ambala

Key Value

Document Fees
INR 1000 /-
EMD
INR 21740.0 /-
Tender Value
INR 10.87 Lakhs /-

BOQ Items

Name of Work:Providing and fixing of 01 No. 500 KVA distribution Transformer and its accessories at Babyal Link Drain pump house in SYL W/S Division Ambala.
Sl. No. Item Description
1[11.5.2]12 mm cement plaster of mix : 2. 1:3 (1 cement: 3 fine sand)
2[11.62.1]Colour washing such as green, blue or buff to give an even shade : 1. New work (two or more coats) with a base coat of white washing with lime
3[11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work
4[11.93.1]Finishing walls with water proofing cement paint of required shade : 1. New work (Two or more coats applied @ 3.84 kg/10 sqm)
5[13.3.1.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb
6[13.6.2]Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 2. Using flats 30x6mm for diagonal braces and central cross piece
7[2.PH098] PH098. 500 KVA Capacity Transformer ISI marked of approved make of UHBVNL i.e. Siemens India, Kirloskar Electric Company Limited, Uttam Bharat Kotsans Pvt Ltd
8[2.PH117] PH117. Installation charges for 500 KVA Capacity Transformer
9[4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
10[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
11[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
12[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform
13[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
14[7.40.1]Brick work with common burnt clay machine moulded non-modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 1. From ground level up to plinth level
15[7.40.2]Brick work with common burnt clay machine moulded non-modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 2. Above plinth level up to floor IV level
16[9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10
17[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter
18H Pole prestressed cement concrete 11 meters long as per IS:1678-1960 with G.O switch and all accessories i.e. lighting arrestor model ALPRO/ALSTEM/LEMCO make suitablefor 11 KV 3 phase 50Hz ground neutral system , stay set with stay wire , 11 KV pin insulator with pin , 11 KV gang operated switch including suitable size of copper blade erection work etc. complete in all respect as per approved specifications of UHBVN Haryana.
19H.T meter with box for 350KW as per approved make of UHBVN Haryana
20P.T with test report and inspection charges of all electric items/Transformer etc in this work in all respect ( CEI CMT Lab test) HT test LT report.
21C.T 3 phase 4 pole LT CT operated (inbuilt CTs) with its test report and inspection charges conforming to UHBVN Nigam specifications ( CT and PT , HT Meter , MCB Box ) and complete in all respect and latest amendments thereof
22H.T XLPE Cable Havells make 95sq. mm 3 core including cost of holding of cable etc with GSL wire 7/8 SWF conforming to ISS 280/1975/1963 as per approved specifications of UHBVN Haryana
23Cable box (XLPE)or cable end termination with heat shrinkable kit 95 sq. mm outdoor and indoor with all its accessories including lugs suitable for 3 core for conductor cable of 11 KV grade as per approved specifications of UHBVN Haryana.
24G.L chemical earthing with G.L earth pipe 4.5 meter long and 40 mm dia using salt and charcoal/coke and salt as per required with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including all accessories for having lock and watering arrangements, copper strip 25 mm x 3 mm G.I strip at 0.5 meter below ground as strip electrode , 25 mm x 5 mm copper strip in 40 mm dia G.I pipe from earth electrode as required, 25 mm x 5 mm copper strip on surface or in recess for connections etc. with providing necessary masonry work complete in all respect as per requirement and approved specifications of UHBVN Haryana