Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | A) CIVIL Works |
| 2 | A-1) Construction of Enterance Ramp (Plinth Height 300mm)Type-III (2 Nos) |
| 3 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 4 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
| 5 | Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type |
| 6 | 12.5mm thick cement plaster 1:4. |
| 7 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 8 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 9 | Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurrycontainingpigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 10 | Providing and Laying Tactile Flooringfull body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between jointswith WhiteCement containingpigment to match the shade complete in all respect. (Tile design and patternwill be as per guidelines issued for persons with disability) |
| 11 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 12 | Finishing walls with exterior decorative cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 13 | A-2) Construction of Enterance Plinth(1 Nos) |
| 14 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 15 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
| 16 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 17 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 18 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. |
| 19 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 20 | 12.5 mm thick cement plaster 1:4. |
| 21 | 20 mm thick cement plaster 1:4. |
| 22 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 23 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 24 | A-3) Construction of Lift Well (for Ground + 1 Story Building(1 Nos) |
| 25 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 26 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 27 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.Footing |
| 28 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 29 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.LintelGround Floor |
| 30 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.First Floor |
| 31 | Extra Rat for First Floor |
| 32 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.Beams |
| 33 | Ground Floor |
| 34 | First Floor |
| 35 | Extra rate for First Floor |
| 36 | SlabGround Floor |
| 37 | FirstFloor |
| 38 | Extra rate for First Floor |
| 39 | WallGround Floor |
| 40 | First Floor |
| 41 | Extra rate for First Floor |
| 42 | ColumnsGround Floor |
| 43 | First Floor |
| 44 | Extra rate for Second Floor |
| 45 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain)Ground Floor |
| 46 | First Floor |
| 47 | Extra for First Floor |
| 48 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.Ground Floor |
| 49 | First Floor |
| 50 | Extra for First Floor |
| 51 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.Ground Floor |
| 52 | First Floor |
| 53 | Extra for First Floor |
| 54 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintelsGround Floor |
| 55 | First Floor |
| 56 | Extra for First Floor |
| 57 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 58 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 59 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..Ground Floor |
| 60 | First Floor |
| 61 | Extra rate for First Floor |
| 62 | Second Floor |
| 63 | Extra rate for Second Floor |
| 64 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs completeDoors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 65 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mmhaving thickness of1.25mm (18 gauge), shash bar MS Tee 25mm x 3mmwhere required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primercomplete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 66 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 67 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 68 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect |
| 69 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 70 | 12.5mm thick cement plaster 1:5. |
| 71 | 20 mm thick cement plaster 1:5 in two coats work. |
| 72 | 12.5 mm thick cement plaster 1:4. |
| 73 | 20 mm thick cement plaster 1:4. |
| 74 | Extra rate for Smooth Surface of Ceiling. |
| 75 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia. |
| 76 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend |
| 77 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 78 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 79 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 80 | Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating |
| 81 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushingThird Floor |
| 82 | Extra rate for Second Floor |
| 83 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 84 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 85 | Conglomerate floor 50mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material). |
| 86 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of materialFirst Floor |
| 87 | Extra rate for First Floor |
| 88 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.Basement & Ground Floor |
| 89 | First Floor |
| 90 | Extra rate for First Floor |
| 91 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishingGround Floor |
| 92 | First Floor |
| 93 | Extra rate for First Floor |
| 94 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. Ground Floor |
| 95 | First Floor |
| 96 | Extra rate for First Floor |
| 97 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 98 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position completeFoundation |
| 99 | Basement & Ground Floor |
| 100 | First Floor |
| 101 | Extra rate for First Floor |
| 102 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 103 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one sidefixed and one side fixed with slotted holesto allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 104 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 105 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to getrequired finish |
| 106 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 107 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 108 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 109 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 110 | Construction ofPlinth protection complete as per drawing. |
| 111 | Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer-In-Charge. |
| 112 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. |
| 113 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 114 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying inplinthin 15 cm layers including ramming, watering and consolidating including all leads. |
| 115 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 116 | Conglomerate floor 40mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material). |
| 117 | 12.5 mm thick cement plaster 1:5complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer-In-Charge. |
| 118 | A-4) Parking Facility and Tactile/Guide Path outside building for PwD (1 Nos) |
| 119 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 120 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 121 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.Footing |
| 122 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 123 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 124 | Steel work in hip & jack rafters common rafters purlins etc. with angle cleats and other connecting plates |
| 125 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing(size, shape and pitch of corrugation as approved by Engineer-in-charge)The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick |
| 126 | Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colourfixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge. |
| 127 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 128 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 129 | Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications |
| 130 | Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 131 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 132 | Providing and Laying Tactile Flooringfull body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between jointswith WhiteCement containingpigment to match the shade complete in all respect. (Tile design and patternwill be as per guidelines issued for persons with disability) |
| 133 | Cutting of floor topping of concrete / Kota Stone / any kind of marble/ tile floor depth up to 50mm with the help of mechanical cutter and chisel (with due care so that surrounding floor should not be damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm to 28mm thick cement concrete 1:2:4 as per requirement complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge. |
| 134 | A-5) Toilets for PwD (G+Storey)(1 Nos) |
| 135 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 136 | Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 137 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.Door LintelGround floor |
| 138 | First Floor |
| 139 | Extra Rate for First Floor |
| 140 | SlabGround Floor (Ist level) |
| 141 | Extra Rate for First Floor |
| 142 | Extra Rate for First Floor |
| 143 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.Ground Floor |
| 144 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.First Floor |
| 145 | Extra Rate For First Floor |
| 146 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintelsGround Floor |
| 147 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintelsFirst Floor |
| 148 | Extra Rate For First Floor |
| 149 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 150 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 151 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..Ground Floor |
| 152 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..First Floor |
| 153 | Extra Rate For First Floor |
| 154 | 12.5mm thick cement plaster 1:5. |
| 155 | 20 mm thick cement plaster 1:5 in two coats work. |
| 156 | 12.5 mm thick cement plaster 1:4. |
| 157 | 20mm thick cement plaster 1:4 in two coat work. |
| 158 | Extra for Smooth Surface of Ceiling. |
| 159 | Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams. |
| 160 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia. |
| 161 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend |
| 162 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 163 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 164 | Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating |
| 165 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 166 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushingSecond Floor |
| 167 | Extra rate for Second Floor |
| 168 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 169 | Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 170 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 171 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of materialFirst Floor |
| 172 | Extra rate for First Floor |
| 173 | Providing and laying Rectified Porcelinfloor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved makeIS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., completeGround Floor |
| 174 | Providing and laying Rectified Porcelinfloor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved makeIS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., completeFirst Floor |
| 175 | Extra rate for First Floor |
| 176 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.Ground Floor |
| 177 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.First Floor |
| 178 | Extra rate for First Floor |
| 179 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishingGround Floor |
| 180 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishingFirst Floor |
| 181 | Extra rate for First Floor |
| 182 | Providing and Laying Tactile Flooringfull body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between jointswith WhiteCement containingpigment to match the shade complete in all respect. (Tile design and patternwill be as per guidelines issued for persons with disability) |
| 183 | Providing and fixing 1st quality ceramic glazed wall tilesMatt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.Ground Floor |
| 184 | Providing and fixing 1st quality ceramic glazed wall tilesMatt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.First Floor |
| 185 | Extra rate for First Floor |
| 186 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion & Chaukhat |
| 187 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 188 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Pre-laminated particle board with decorative lamination on one side. |
| 189 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 190 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 191 | Providing an fixing MS of Double action spring hinges with necessary screws etc. complete100mm |
| 192 | Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications,Harmonised guidelines for PwD and as desired by engineer-in-charge. |
| 193 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position completeGround Floor |
| 194 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position completeFirst Floor |
| 195 | Extra rate for First Floor |
| 196 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 197 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 198 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 199 | A-6) Providing SS Railing along wall to ExistingStair case |
| 200 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 matt finish duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 201 | Providing and fixing acrylic Braile indicators of size 170mm x 35mm to be fixed on handrails of the the approved design and make having Braile dots raised 0.5mm above base plate, to the installed at the specified locations as per the directions of the Engineer-in-Charge complete s per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-Charge |
| 202 | A-7) Upgradation of Information, Safety Sinage & Emergency Exit for Person with Disability |
| 203 | Providing and Installation of Safety signage as per guideline for person with disability made ofretro reflectivesheeting as per colour specified and writing matter will be ofsame material in whitefixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washercomplete as per specification and as desired by engineer in charge. |
| 204 | Informatory sign board 800x600mm rectangular as per IRC 67- 2012withhighintensityMicroprismaticgrade retroreflective Sheetingas per ASTM D 4956 – 09 and as per IRC 67 – 2012.fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angleiron supportedonasquare hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical postcompleteasper clause 801 ofMORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting& a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .Using highintensityMicroprismaticgrade retroreflective SheetingType IVas per ASTM D 4956 09 and as per IRC 67 2012 |
| 205 | Providing and laying 50 mm wide antiskid tape made of slip resistant material colour contrast, edge strip, self adhesive to be fixed onfront edge of Stair treads to help people with visual disabliity and elderly even in dim light conditions &reduce the risk of slipping Make 3M or equivalent brand complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge. |
| 206 | Providing and laying 25 mm to 50mm wide high intensitiy reflective conspicuity tape colour contrast, edge strip, self adhesive to be fixed onfront edge of Stair riser to help people with visual disabliity and elderly even in dim light conditions &reduce the risk of slipping Make 3M or equivalent brand complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge. |
| 207 | A-8) Upgradation of doors hardware, Resting facilities & Tactile/Guide path inside buildingetc for PwD |
| 208 | Providing and Laying Tactile Flooringfull body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between jointswith WhiteCement containingpigment to match the shade complete in all respect. (Tile design and patternwill be as per guidelines issued for persons with disability) |
| 209 | Cutting of floor topping of concrete / Kota Stone / any kind of marble/ tile floor depth up to 50mm with the help of mechanical cutter and chisel (with due care so that surrounding floor should not be damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm to 28mm thick cement concrete 1:2:4 as per requirement complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge. |
| 210 | Removal of Door Shutter (Panneled/Glazed), for providing vision panel, repairing and refixing the same in original position as per specification and as desired by engineer in charge. (including Cost of new hinges, Screw, class, bidding & providing vision panel not exceeding 0.1 sqm complete as per specifications) in square/rectangle |
| 211 | Providing & Installation of Sitting Benches 3 Seater made of S.S matt finishing 1800mm in length, 900mm width, 500mm sitting height, without arm, seat & back shall be made of 10strip M.S pipe 63mm x 25mm of 18 guage to be fixed in floor bymeans of rawl metal plug incorridor for resting purpose complete as per specification & as desired by Engineer-in-Charge. (wt not be less than 25kg) |
| 212 | B) PUBLIC HEALTH WORKS:- |
| 213 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation |
| 214 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B |
| 215 | b) 110mm o/d SWR UPVC pipe lines laid complete |
| 216 | c) 75mm o/d SWR UPVC pipe line laid complete |
| 217 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm i/d pipes |
| 218 | Elbow 90 Degree (All side socket) |
| 219 | Single Tee With Door |
| 220 | For 75mm i/d pipes |
| 221 | Elbow 90 degree (all side socket) |
| 222 | Single Tee With Door |
| 223 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm.100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 224 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 225 | Estate Sewerage System |
| 226 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.110 mm o/d pipes |
| 227 | 160 mm o/d pipes |
| 228 | Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer- in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.a) For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky |
| 229 | For Sewer Line 110 mm dia as per Detail attached |
| 230 | For Sewer Line 160 mm dia as per Detail attached |
| 231 | Internal Water Supply System |
| 232 | EXTERNAL IN THE GROUND : Providingand fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.c) CPVC SDR 11 pipe & Fittings 25mm o/d |
| 233 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.a) SDR 11 CPVC pipes & fittings 16mm o/d |
| 234 | b) SDR 11 CPVC pipes & fittings 20mm o/d |
| 235 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75mm x 75mmC PVC P 16mm +20mm |
| 236 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.a) Through wall 11.43 cm thick |
| 237 | b) Through wall 22.86 cm thick |
| 238 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.20mm i/d Brass Ball valves |
| 239 | 25mm i/d Brass Ball valves |
| 240 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets oropen area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.I) All classes of soil except rocky Earth work upto 1.5 m Depth for |
| 241 | Sanitary Installation |
| 242 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.Ground + First Floor |
| 243 | Providing and fixing jet spray with 2\"-6\" long PVC pipe.With C.P. Brass nut |
| 244 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.. |
| 245 | Providing and fixing in position C.P. brass soap dish of approved make (tothe approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 246 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.(e) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut |
| 247 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.i) C.P. brass Bib cock long nose/ long body foam flow withoutflange |
| 248 | ii) C.P. brass Bib cock foam flow without flange |
| 249 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.b) C.P.brass 15mm Concealed stop cock with flange. |
| 250 | d) C.P.brass 20mm concealed stop cock with flange |
| 251 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 252 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. i) C.P. Brass extension piece, 25mm long to 50mm long |
| 253 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.i) Triple Layer Tanks |
| 254 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)a) Size 600mmx450mm |
| 255 | Providing and fixing in position paperholders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.a) C.P. brass toilet paper holder |
| 256 | Providing and fixing in position automatic brass Ball Cock in tanks.b) Brass Ball Cock with rod and Plastic Ball25mm i/d |
| 257 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d |
| 258 | Construction of Platform complete as per Specification & as desired by Engineer-in charge |
| 259 | C) ELECTRICAL SERVICES :- |
| 260 | D-1, Providing Internal Electrical Installationsfor Toilet |
| 261 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):-Wiring light point |
| 262 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materialsetc., as per PWD General Specifications:-Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 263 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 264 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 265 | MINIATURE CIRCUIT BREAKERS:-Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 266 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 267 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 268 | Providing Emergency alarm system consisting of following devices & accessories:-Electronic emergency Unit to Installed inside of outside Toilet, Moisture proof Micro-switching unit to be installed One at height of 300mm from the floor & second at height of 900mm from the floor level inside Toilet for activating alarm the over door outside indicator provides an audible & visual signal to indicate the area where assistance is required complete as per specification & requirement defined in Harmonised guidelines & space standards for barrier free built environment for PwD& Elderly persons. |
| 269 | D2) Providing LIFTS(1No.13 Passengers for G+1 Storey) |
| 270 | *Supply, Installation, Testing and Commissioning of 1 Nos. Lift of 13 Passengers Machine Room Less.*Type and Capacity :Approximately 884 Kg , 13 Passengers *Speed:1.0 Meter per second*Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.*Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way*Travel: Approximately 4 meter________*Serving: 2 Floors 2 Stops 2 Openings 2 Levels (All on the same side)*Hoist way Required : 2600mm (Wide) x 1900mm (Deep) Clear dimensions*Headroom Height (HR): 5000 mm beyond finished floor level of last landing *Pit Depth : 1600mm below the finish floor level of first landing *Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter *Car Enclosure : Constructed out of stainless steelScratch proof Finish (Vandal Proof).*Car Entrance: Center Opening Automatic Doors with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) *Door operation : Automatic DC Door operation with adjustable door opening and closing timings *Control: Simplex full selective collective control with and without attentdent*Operation: Automatic *Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current*Flooring: Floor Skid - Resistant as per standard*Fan: Blower Fan in Car for ventilation with Auto cut off*Lighting: LED for Car Lighting*Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings *Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) *Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level *Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level *All std. Govt. features. |
| 271 | Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication9. Steel items, door frames sill angle\"s, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level\"s in english language only and indication of door for entrance / exit is .either Open or Close19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. |
| 272 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:-Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):- |
| 273 | Wiring light point |
| 274 | Wiring 6Amp.wall socket point |
| 275 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 276 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 277 | COPPER EARTHING :-(8 SWG COPPER EARTHING :):-Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 278 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 279 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 280 | MS SHEET ENCLOSURE FOR MCCB\"s:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shallbe made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/topwith cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 281 | Supply and erection ofLEDBulk Head 9/10 wattIP65 surface mounted, pressure die cast housing complete in all respects as approved. and desired by the Engineer in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 282 | D-3, PA System,Fire /Emergency Evacuation System |
| 283 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push,6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material and painting as required:-Wiring 3 pin 6 Amp. wall socket point (for hooter cum strobe/exit signage/emergency lights/eco LED lights) |
| 284 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1sq.mm (Un-sheathed) |
| 285 | Overall size 1.5sq.mm (Un-sheathed) |
| 286 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 287 | Supply, Erection, Testing & commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. UL Listed and FM Approved, with erection of the same with connections, testing etc.Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 288 | Supply, Erection, Testing & commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.Project specific OEM authorization required for executing agency.complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 289 | Supply, Erection, Testing and Commisioning of of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel (01-loop - With Digital Voice Command Center)with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition. Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 290 | Supply, Erection, Testing and Commisioning of same OEM make Cloud based service through universal gateway, which shall be enabled through internet. Remote health monitoring solution shall utilize cloud based software-as-a-service web application & supplementary network gateway hardware. System shall provide secure web access to cloud based web application using any of the web browsers like Google Chrome (preferable), Internet Explorer etc. from any computer/ tablet/ smartphone connected over internet via defined credentials – username and password. It shall also have the facility to monitor the cloud service over the mobile apps. The cloud based web application shall capture all fire alarm system data points as received from the system via supplementary gateway hardware of the same make as Fire Alarm Panel. The software shall display real time view of fire system effectiveness, multi-location unified view, custom dashboard, device level information, scheduled reporting, e-mail of critical alarms. The cloud service shall be capable of monitoring 250000 datapoints scattered accross multiple install bases spread accross multiple geographical locations. Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 291 | Supply, Erection, Testing & commissioning of Inbuilt automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH with Emergency evacuation Control Panel & Digital Voice command system with Battery Dress Panel .Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 292 | Supply, Erection, Testing and Commisioning of Addressable Manual Call Point (Pull down / Break Glass Type),The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. UL Listed and FM Approved including cost of petty material required to complete the work. Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 293 | Supply, Erection, Testing and Commisioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed with 24V DC power supply . including cost of petty material required to complete the work . Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 294 | Supply, Erection, Testing & commissioning of2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of the same make as that of theControl Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed.Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 295 | Supply, Erection, ofPlastic moldedback box forSpeakers.. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 296 | Supply, Installation, Testing and Commissioning ofDigital Audio Amplifier. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessaryenclosures with local FFT Raiser.TheDigital Audio Amplifiershallbefully monitored for fault and alarmreporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. The Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power). Project specific OEM authorization required for executing agency.. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 297 | Supply, Installation, Testing and Commissioning of Remote Paging Station for Zone selection & paging to selected area in case of emergency.Project specific OEM authorization required for executing agency. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 298 | Supply, Installation, Testing and Commissioning ofExiLED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code, |
| 299 | Supply, Installation, Testing and Commissioning ofEmergency Light AgoraLED NM LED IP42 230V 2X6W 1h/3h/8h . The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP42/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED > 100 000 hoursluminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) >100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP65, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting, |
| 300 | Supply, Installation, Testing and Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter,Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No\"s, Rated Input Voltage208/220/230/240 Vac, Maximumworkinginput voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity,Rated kVA 1000 VA, Rated kW800 Watts, Load typeResistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio3:1, Online Efficiency 88%,Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available,Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available,IntelligentFans Speed control Available, Auto restart function Available, Cold start Available. |
| 301 | Providing, laying & fixing of fire resistance cable(Colour Red) (at 950° C for 180 minutes) of BS6387/BS7846 armourded Cable, 2C X 1.5 sqmm, BS6387 & BS7846, annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanized steel wire armour, low smoke & zero halogen (LSZH) red outer sheath. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3), |
| 302 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy