Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #36872118

Tender For Purchase Of Membrane Filteration Assembly For Cwa(W&S)-I Division

Issued by Boards / Undertakings / PSU · wazirabad, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Mar 2023
0 days left
EMD
38400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
wazirabad → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Nit No.44, Item No.02 (2022-23)Cwa (W And S)-I Purchase Of Membrane Filteration Assembly For Cwa(W And S)-I Division , • Equipment Type: Benchtop • Group: Microbiology • Analysis: Water/Wastewater • Parameter:Microbiological Count/ Tss • Scope: Central/Zonal/Plant Labs/Field Analysis • Principle: Filtration Each Unit Of Stainless Steel, 3-6 Station Manifold Assembly Should Include The Following Components As Per The Mentioned Specification(S): 3-6 Station Manifold System-1No:S.S. Sterility Test Manifold System With 6 Stations, An Integrated Filtration System For Filtering Multiple Samples Off One Vacuum Source And Made Up Of Ss304 With Support Plates, Teflon Spool, Should Be Compatible With Ss Sterility Test Filter Holders 47Mm. •Ss Filter Holder 3-6 Nos: Each Of 47Mm Diameter & 300Ml Capacity, Ultra Light Weight Stainless Steel Filter Holder With Funnel For Vacuum Filter Applications; Stainless Steel 304 Funnel, Lid, Base And Support Screen Stainless Steel 304 Spring Clamp And Silicone Stopper; Unique Stainless Steel Support Screen To Avoid Rupture Of Membrane Disc During Filtration, Standard Silicone Rubber Stopper For Mounting Filtration Assembly Either On 1L Filtration Flask Or On Ss Sterility Test Manifold System; Complete Unit Can Be Autoclaved With Membrane In Place. •Stop Cork With Tube-1No: Material Of Construction: Silicon/Neoprene; Rubber Size: No #8 With Ss304 Tube All Compatible With The Receiver Flask •Receiver Flask-2Nos: Material Of Construction: Borosilicate Glass, Capacity: 1000Ml •Silicon Tube With Connector-2No: Diameter: 10 X 8 Mm; Length: 1 To 1.5 Meter •Vacuum Pump-1No: Flow – 75 Lpm (High Flow); Vacuum -550 Mm Hg; Moc- Aluminium Die Cast, Motor–1/4Hp; Power – 230V Ac; Noise Level- 50Db; Connection – 10Mm Hose •Forcep-1No: Blunt & Medium Size

BOQ

Name of Work: PURCHASE OF MEMBRANE FILTERATION ASSEMBLY FOR CWA(W&S)-I DIVISION
Sl. No. Item Description
1• Equipment Type: Benchtop• Group: Microbiology• Analysis: Water/Wastewater• Parameter:Microbiological count/ TSS• Scope: Central/Zonal/Plant labs/Field Analysis• Principle: FiltrationEach unit of Stainless Steel, 3-6 Station Manifold Assembly should include the following components as per the mentioned specification(s):3-6 Station Manifold System-1NO:S.S. Sterility Test Manifold System with 6 stations, an integrated filtration system for filtering multiple samples off one vacuum source and made up of SS304 with support plates, Teflon spool, should be compatible with SS Sterility Test Filter Holders 47mm.•SS Filter holder 3-6 NOs: each of 47mm diameter & 300ml capacity, ultra light weight stainless steel filter holder with funnel for vacuum filter applications; Stainless steel 304 funnel, lid, base and support screenStainless steel 304 spring clamp and silicone stopper; Unique stainless steel support screen to avoid rupture of membrane disc during filtration, Standard silicone rubber stopper for mounting filtration assembly either on 1L filtration flask or on SS Sterility Test Manifold System; Complete unit can be autoclaved with membrane in place.•Stop Cork with tube-1NO: Material of Construction: Silicon/Neoprene; Rubber Size: No #8 with SS304 tube all compatible with the receiver flask•Receiver flask-2NOs: Material of Construction: Borosilicate Glass, Capacity: 1000mL•Silicon Tube with Connector-2NO: Diameter: 10 x 8 mm; Length: 1 to 1.5 meter•Vacuum Pump-1NO: Flow – 75 LPM (High Flow); Vacuum -550 mm HG; MOC- Aluminium Die Cast, Motor–1/4hp; Power – 230V AC; Noise level- 50DB; Connection – 10mm Hose•Forcep-1NO: Blunt & medium size

AI Tender Summary

OUR REF NO 36872118
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 27-03-2023
Authority
Authority Name Delhi Jal Board
Work Description Nit No.44, Item No.02 (2022-23)Cwa (W And S)-I Purchase Of Membrane Filteration Assembly For Cwa(W And S)-I Division , • Equipment Type: Benchtop • Group: Microbiology • Analysis: Water/Wastewater • Parameter:Microbiological Count/ Tss • Scope: Central/Zonal/Plant Labs/Field Analysis • Principle: Filtration Each Unit Of Stainless Steel, 3-6 Station Manifold Assembly Should Include The Following Components As Per The Mentioned Specification(S): 3-6 Station Manifold System-1No:S.S. Sterility Test Manifold System With 6 Stations, An Integrated Filtration System For Filtering Multiple Samples Off One Vacuum Source And Made Up Of Ss304 With Support Plates, Teflon Spool, Should Be Compatible With Ss Sterility Test Filter Holders 47Mm. •Ss Filter Holder 3-6 Nos: Each Of 47Mm Diameter & 300Ml Capacity, Ultra Light Weight Stainless Steel Filter Holder With Funnel For Vacuum Filter Applications; Stainless Steel 304 Funnel, Lid, Base And Support Screen Stainless Steel 304 Spring Clamp And Silicone Stopper; Unique Stainless Steel Support Screen To Avoid Rupture Of Membrane Disc During Filtration, Standard Silicone Rubber Stopper For Mounting Filtration Assembly Either On 1L Filtration Flask Or On Ss Sterility Test Manifold System; Complete Unit Can Be Autoclaved With Membrane In Place. •Stop Cork With Tube-1No: Material Of Construction: Silicon/Neoprene; Rubber Size: No #8 With Ss304 Tube All Compatible With The Receiver Flask •Receiver Flask-2Nos: Material Of Construction: Borosilicate Glass, Capacity: 1000Ml •Silicon Tube With Connector-2No: Diameter: 10 X 8 Mm; Length: 1 To 1.5 Meter •Vacuum Pump-1No: Flow – 75 Lpm (High Flow); Vacuum -550 Mm Hg; Moc- Aluminium Die Cast, Motor–1/4Hp; Power – 230V Ac; Noise Level- 50Db; Connection – 10Mm Hose •Forcep-1No: Blunt & Medium Size
Basic Detail
Tender No NIT NO.44(2022-23)CWA (W and S)-I
Bidding Type Tender
Location
City wazirabad
State Delhi
Key Dates
Publish Date 18 Mar 2023
Submission Date 27 Mar 2023
Open Date 27 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 38400
Exemption Not Available
Document List
NIT44B.pdf
4c8a4d19-21f6-47c3-bd47-275195352999.html
BOQ_311209.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 27, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

NIT44B.pdf

html

4c8a4d19-21f6-47c3-bd47-275195352999.html

xls

BOQ_311209.xls

pdf

Tendernotice_1.pdf

TenderDetail