Tender For Rectification And Maintenance Of Kenduadih G.T2 Feeder 11 Kv O/H Line, Khaira Lt O/H Line, Post Office Lt O/H Line, Machhli Patti O/H Line And Hindi Bhawan New Sub-0Station Under Kenduadih Colliery.
Tender Value
2.36 Lakhs
Estimated cost
Bid Submission
23 Mar 2023
0 days left
EMD
2962
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kenduadih → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Rectification And Maintenance Of Kenduadih G.T2 Feeder 11 Kv O/H Line, Khaira Lt O/H Line, Post Office Lt O/H Line, Machhli Patti O/H Line And Hindi Bhawan New Sub-0Station Under Kenduadih Colliery.
BOQ
| Sl. No. | Item Description |
| 1 | Item Description/ Heading |
| 2 | A) FOR 3 G.T2 feeder 11 KV maintenance - Opening jumper for searching faults & after megguring re-jumpering |
| 3 | Erection of Wolf Conductor 270 meters of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR\" 2012, P-39, 12.22) @ 0.726 Kg/Mtr |
| 4 | Erection of Dog Conductor 660 meters of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR\" 2012, P-39, 12.22) @ 0.394 Kg/Mtr |
| 5 | Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for 240 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR\" 2012, P-34, 10.3.3) |
| 6 | Opening jumper for changing of faulty Disc insulator |
| 7 | Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Wolf Conductor 330 Meters) (CPWD SOR\" 2012, P-40, 12.40) @ 0.726 Kg/Mtr |
| 8 | Dismantle of disc/pin insulator for 11 KV over head lines as required. (CPWD SOR\" 2012, P-42, 13.12) |
| 9 | Supply & erection of 11 KV Disc insulator for O/H line with galvanised insulator fittings, bolts, nuts, washers etc. as required (CPWD SOR\" 2012, P-42, 13.11) |
| 10 | Supply & erection of 11 KV Pin insulator complete with large steel head G.I pin, nuts, washers etc. as required (CPWD SOR\" 2012, P - 42, 13.10) |
| 11 | Making new jumper with O/H line |
| 12 | Opening cable jumper from O/H line |
| 13 | Taking down of one no. PVC insulated power cable of 11 KV grade of 185 sq mm for making fresh lead (CPWD SOR\" 2012, P-28, 8.3.2) |
| 14 | Excavation of one number PVC insulated and PVC sheated/XLPE power cable of 11 KV grade of 185 sq mm size from ground (CPWD SOR\" 2012, P-28, 8.1.2) |
| 15 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR\" 2012, P-34, 10.2.3) |
| 16 | Laying/Hanging of one no. PVC insulated power cable of 11 KV grade of 185 sq mm after making fresh lead (CPWD SOR\" 2012, P-28, 8.3.2) |
| 17 | Making new cable jumper with O/H line |
| 18 | Repairing of AB Switch |
| 19 | B) FOR Store work - Transportaton of 2000 mtrs conductor and 1 drum Transformer oil (2 days 8+7 = 15 Heads) |
| 20 | C) FOR Khaira LT O/H line maintenance - Transportation of pole from store to site |
| 21 | Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR\" 2012, P-36, 11.3.3) |
| 22 | Fabrication & erection of bracket & clamps |
| 23 | Supply & erection of MS Nut & Bolts |
| 24 | Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Rabbit Conductor 100 Meters) (CPWD SOR\" 2012, P-40, 12.40) @ 0.214 Kg/Mtr |
| 25 | Dismantle of LV/MV shackle/pin insulators etc as required. (CPWD SOR\" 2012, P-39, 12.20) |
| 26 | Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR\" 2012, P-39, 12.17) |
| 27 | Erection/Sagging of Rabbit Conductor 100 meters of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR\" 2012, P-39, 12.21) @ 0.214 Kg/Mtr |
| 28 | D) FOR Post Office LT O/H line maintenance - Transportation of pole from store to site |
| 29 | Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR\" 2012, P-36, 11.3.3) |
| 30 | Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Rabbit Conductor 120 Meters) (CPWD SOR\" 2012, P-40, 12.40) @ 0.214 Kg/Mtr |
| 31 | Fabrication & erection of bracket & clamps |
| 32 | Supply & erection of MS Nut & Bolts |
| 33 | Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR\" 2012, P-39, 12.17) |
| 34 | Erection/Sagging of Rabbit Conductor 120 meters of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR\" 2012, P-39, 12.21) @ 0.214 Kg/Mtr |
| 35 | E) FOR Machhli Patti LT O/H line maintenance - Transportation of pole at site |
| 36 | Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR\" 2012, P-36, 11.3.3) |
| 37 | Taking down of one no. PVC insulated power cable of 1.1 KV grade of 35 sq mm for making fresh lead (CPWD SOR\" 2012, P-26, 7.5.1) |
| 38 | Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Dog Conductor 120 Meters) (CPWD SOR\" 2012, P-40, 12.40) @ 0.394 Kg/Mtr |
| 39 | Fabrication & erection of bracket & clamps |
| 40 | Supply & erection of MS Nut & Bolts |
| 41 | Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 35 sq mm after making fresh lead (CPWD SOR\" 2012, P-26, 7.5.1) |
| 42 | Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR\" 2012, P-39, 12.17) |
| 43 | Erection of Dog Conductor 120 meters of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR\" 2012, P-39, 12.22) @ 0.394 Kg/Mtr |
| 44 | F) FOR Khaira & Hindi Bhawan new S/S - Making/Erection of new Earthpit with charcoal & salt (charcoal & salt not supply by departmental) |
| 45 | Making connection of Transformer & switch with earthpit |
| 46 | G) FOR E.B Section 550V O/H line maintenance - Taking down of two nos PVC insulated power cable of 11 KV grade of 120 sq mm for making fresh lead (CPWD SOR\" 2012, P-28, 8.3.1) 25+25 = 50 Mtrs |
| 47 | Laying/Hanging of two nos PVC insulated power cable of 11 KV grade of 185 & 240 sq mm after making fresh lead (CPWD SOR\" 2012, P-28, 8.3.2) 25+25 = 50 Mtrs |
| 48 | Opening cable jumper from O/H line |
| 49 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185 & 240 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR\" 2012, P-34, 10.2.3) |
| 50 | Mechanical cable joint in switch/Transformer with HT tape & others materials |
| 51 | Making new cable jumper with O/H line |
| 52 | Total impact of GST for the purpose of CTC |
AI Tender Summary
Tender Timeline
Mar 18, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMar 23, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 24, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender