Tender For Electrical Works Of Makeshift Dcj Studio At Cuk, Tulmulla, Ganderbal, Ganderbal-Jammu And Kashmir

Central University Of Kashmir-CUK has published Tender For Electrical Works Of Makeshift Dcj Studio At Cuk, Tulmulla, Ganderbal. Submission Date for this Tender is 30-03-2023. Electrical Maintenance Tenders in Ganderbal Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

36847190
Tender For Electrical Works Of Makeshift Dcj Studio At Cuk, Tulmulla, Ganderbal
Open Tender
Indian
Jammu And Kashmir
Ganderbal
30-03-2023

Tender Details

E-Tender For Electrical Works Of Makeshift Dcj Studio At Cuk, Tulmulla, Ganderbal

Key Value

Document Fees
INR 1000 /-
EMD
INR 26000.0 /-
Tender Value
INR 13 Lakhs /-

BOQ Items

Name of Work: e-Tender for Electrical works of makeshift DCJ Studio at CUK, Tulmulla, Ganderbal
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Computer/UPS )
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire(for AC"s)
7Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required (for AC"s)..
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 25 mm dia and 2mm thick.
9Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB) :6 way (4 + 18), Double door
10Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):12 way, Double door
11Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (Single Pole)
12Supplying and fixing 32 A rating, 240V 10 kA, “C” curve, Doublepole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
13Supplying and fixing 40 rating Triple pole and neutral, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (Triple pole and neutral)
14Providing Installation Testing and Commissioning of Chemical ear thing with 03 meter Galvanised Electrode etcas required.
15Providing and Fixing of Testing Terminal Brass Type
16Providingand Fixing 25mmX 5mm GI Stripon surface or in recesses for connections etc. as required
17Supply,installation and Testing of LED Surface /concealed square Panel Light with 20-30W complete assembly as required as per specifications. Size (12"/12")
18Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(1 run of cable)
19Supplying and fixing Computer socket outletRJ45 modular switch/ socket on the modular plate & switch box including connections including modular plate etc(MS box). as required.
20Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required with25 mm dia ,2mm thick.
22Supply and installation, testing and commissioning of fire alarm system having inteligent state of art control panel, 230V, UPS power source,6Nos integent smoke detectors, 2Manual Call Points 250W ampplifier, hooter,remote information system, intercommunication ports(2nos),conforming to IEC-268-3 complte with all accessories and indication including wiring complete inall respect
23Providing installation of AirConditioner 5 Star 1.5Ton Spilit type including both indoor and outdoor units, Control Cable, Copper pipe, etc complete job.The ducts to be covered with 10mm open cell nitril, both from inside and outside to attenuate noise
2424 Port Network switch manageable 10/100/1000 GB 24 port network switch in 20+4 mode with 1000BASE-X SEP uplink ports.
25SITC of STUDIO PANEL. (INDOOR PANEL-IP:42) (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry. INCOMER 1 Nos. 200A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended Complete with Lock & sealing arrangement BUSBARS 250Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar Complete with Lock & sealing arrangement METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class-1.0 accuracy for all incomer feeder. Refer to Cat no. - Trinity-NF29 E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB OUTGOINGS 2 Nos. 100A TPN MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. 1 Nos. 63A, TPN, MCB, 16kA 2 Nos. 63A, DP, MCB, 16kA 2 Nos. 32A,DP, MCB, 10kA
26Design SITC of out door cubical type LT Panel suitable for 415V, 3P 4wire 50 HZ AC Supply system fabricated in compartmentized design from CRCA sheet of 21 mm thickness including cleaning and finishing complete with 7 tank process for powder coating in approved shade having 200 Amp Capacity TPNAluminium Bus bar of high mounting 40x40x6mm angle frame dully painted.Incomming 200Amp, 4P,25KA MCCBwith thermalmagnetic release based trip unit speader terminals and phase barriers.
27SITC of 100AMP TPN Copper Busbars on 20x20x4mm, angle frame dully painted.
28Supply, installation testing commissiong of 3.5 core 16 sqmm Aluminium armored cable
29Supply, installation testing commissiong of 3.5 core 120 sqmm,XLPE Aluminium armored cable