}

Re E Tender ( 3Rd Call ) For Procurement Of Kits, Chemicals & Reagents For Two Yearsfrom The Date Of Award Of Contract (Aoc) And Its Extension, If Required, kolkata-West Bengal

Health And Family Welfare Department has published Re E Tender ( 3Rd Call ) For Procurement Of Kits, Chemicals & Reagents For Two Yearsfrom The Date Of Award Of Contract (Aoc) And Its Extension, If Required. Submission Date for this Tender is 19-04-2023. Cleaning and Disinfecting Solutions Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

36840962
Re E Tender ( 3Rd Call ) For Procurement Of Kits, Chemicals & Reagents For Two Yearsfrom The Date Of Award Of Contract (Aoc) And Its Extension, If Required
Open Tender
Indian
West Bengal
kolkata
19-04-2023

Tender Details

RE E TENDER ( 3rd Call ) FOR PROCUREMENT OF KITS, CHEMICALS & REAGENTS FOR TWO YEARSFROM THE DATE OF AWARD OF CONTRACT (AOC) AND ITS EXTENSION, IF REQUIRED /Kits, Chemicals And Reagents Re E Tender ( 3Rd Call ) For Procurement Of Kits, Chemicals And Reagents For Two Years From The Date Of Award Of Contract (Aoc) And Its Extension, If Required , Absolute Alcohol I.P. , Anti Nuclear Factor Rapid Test Kit , Aptt Kit (Action Fsl) , Barium Chloride Powder , Boric Acid Ip. , Barium Sulphate Powder(175Gm) , Citrosteril Disinfectant Chemical Lotion , Collodian , Conc. Sulphuric Acid , Cord Blood Processing Kit (Cbp Kit) For The Cord Blood Bank 1. The Cbp Kit Must Consist Of Three Bags Integrally Connected By Tubing, Two Of Which Are Pvc Bags-One Larger Bag & One Smaller Bag And A Third Smallest Bag Which Is The Cryo Bag / Freezing Bag. 2. The Larger Bag Should Have A Fill Volume Of 200Ml With An Attached Spike For Transferring Content From A Different Collection Bag. It Must Have One Leak Proof Access Port For Injecting Chemicals Inside Or Taking Out Sample. One Additional Entry Port To This Bag Is Preferred For Injecting Chemicals Only Through The Nozzle Of The Syringe Without Using Needle With Very Narrow Calibre Connecting Tubing For Administration Of Cryoprotectant(S). 3. Other Smaller Bag Should Have A Fill Volume Of 150Ml. It Must Have One Leak Proof Access Port For Injecting Chemicals Inside Or Taking Samples From The Bag. 4. The Third Integrally Attached Bag (Cryo Bag / Freezing Bag) Consists Of Eva Material Or Approved Material For Storing Stem Cells At Ultra Low Temperature (Minus 196°C) Of Liquid Nitrogen. It Must Be A 3D Bag (3 Dimensional) With Two Compartments Of 20Ml & 5Ml Capacity With Intercommunication. 5. Length Of This Cryo Bag/Freezing Bag Is 85-87Mm & Width 63-65Mm (However The Total Width Is 71-73Mm Including The Height Of The Two Ports (For Connecting Spike For Transplant) Of The Bag One Connected With The 20Ml Part And Other Connected With The 5Ml Part. This Cryo Bag/Freezing Bag Along With At Least 90Mm Integral Tube Segment Should Fit Inside The Metal Cassette With Dimension 91-92Mm (Length) X 84-85Mm (Width) X 8-9Mm (Thickness) For Preservation. 6. Temperature Range Of Storage Should Be Minus 196°C Plus 40°C. 7. Easily Manipulative Clamp Must Be Present On Every Connecting Tubing From Bag To Bag And From Bag To Spike And Bag To Entry Or Exit Ports. 8. The Kit Should Have An Expiry Of At Least 2 Years From The Date Of Manufacture. 9. The Kit Manufacturing Process Should Follow The National And Or International Standards Like Iso Etc. So That The Bags Are Pyrogen Free, Sterilised, Animal Pathogenicity Test Passed, Can Withstand The Shearing Force During Centrifugation Etc. 10. Should Provide Copy Of The Supply Order To Other National Or International Cord Blood Banks. 11. Should Provide Customer Satisfaction Certificate For The Product. 12. Specimen Of The Kit Must Be Provided To The Tender Committee For Precise Verification Of The Size, Shape, Measurement And Other Specifications. 13. Other Requirement (If Approved And Order Is Placed For Purchase):-Each Supply Lot/Batch Has To Be Provided With Certificate Of Analysis (Quality Assurance Certificate) Otherwise The Kit Will Not Be Accepted. 14. Should Have Icmed 13485 Certification By Qci Or Is / Iso 13485 Certification Or Ce Certificate Or Us Fda Approval Certificate. , French Chalk , Glycin Irrigation Fluid , Haemodialysis Fluid With Bi-Carb , Hamatoxyllin Eosin Stain Powder , Hscrp Test Kit , Hydrogen Peroxide Soln. (20Vol) I.P. , Indole Strip , Koh Solution 10% L , Lactate Test Kit , Liquid Paraffin I.P. (Heavy) , Magnesium Sulphate I.P. , Mb/Bact Antibiotic Suppliment Kit , Nitric Acid , Poly Sodium Citrate , Primary Antibody Er , Primary Antibody Her , Primary Antibody Pr , Pt Reagent , Pyr Reagent , Pyr Strip , Ppd Tuberculin 5Tu/0.1 Ml - 5Ml , Ceftizoxime Antibiotic Disc , Basic Fuchsin , Chloroform A.G. , E.D.T.A. Powder , Methylene Blue Powder

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:RE E TENDER ( 3rd Call ) FOR PROCUREMENT OF KITS, CHEMICALS & REAGENTS FOR TWO YEARSFROM THE DATE OF AWARD OF CONTRACT (AOC) AND ITS EXTENSION, IF REQUIRED
Sl. No. Item Description
1Absolute Alcohol I.P.
2Anti Nuclear Factor Rapid Test Kit
3APTT Kit (Action FSL)
4Barium Chloride Powder
5Boric Acid IP.
6Barium Sulphate Powder(175gm)
7Citrosteril Disinfectant Chemical Lotion
8Collodian
9Conc. Sulphuric Acid
10Cord Blood Processing Kit (CBP Kit) for the Cord Blood Bank 1. The CBP Kit must consist of three bags integrally connected by tubing, two of which are PVC bags-one larger bag & one smaller bag and a third smallest bag which is the Cryo bag / freezing bag. 2. The larger bag should have a fill volume of 200ml with an attached spike for transferring content from a different collection bag. It must have one leak proof access port for injecting chemicals inside or taking out sample. One additional entry port to this bag is preferred for injecting chemicals only through the nozzle of the syringe without using needle with very narrow calibre connecting tubing for administration of Cryoprotectant(s). 3. Other smaller bag should have a fill volume of 150ml. It must have one leak proof access port for injecting chemicals inside or taking samples from the bag. 4. The third integrally attached bag (Cryo bag / Freezing bag) consists of EVA material or approved material for storing stem cells at ultra low temperature (minus 196°C) of liquid nitrogen. It must be a 3D bag (3 dimensional) with two compartments of 20ml & 5ml capacity with intercommunication. 5. Length of this Cryo bag/Freezing bag is 85-87mm & width 63-65mm (However the total width is 71-73mm including the height of the two ports (for connecting spike for transplant) of the bag one connected with the 20ml part and other connected with the 5ml part. This Cryo bag/Freezing bag along with at least 90mm integral tube segment should fit inside the metal cassette with dimension 91-92mm (Length) X 84-85mm (Width) X 8-9mm (thickness) for preservation. 6. Temperature range of storage should be minus 196°C plus 40°C. 7. Easily manipulative clamp must be present on every connecting tubing from bag to bag and from bag to spike and bag to entry or exit ports. 8. The kit should have an expiry of at least 2 years from the date of manufacture. 9. The kit manufacturing process should follow the national and or international standards like ISO etc. so that the bags are pyrogen free, sterilised, animal pathogenicity test passed, can withstand the shearing force during centrifugation etc. 10. Should provide copy of the supply order to other national or international cord blood banks. 11. Should provide customer satisfaction certificate for the product. 12. Specimen of the kit must be provided to the tender committee for precise verification of the size, shape, measurement and other specifications. 13. Other requirement (if approved and order is placed for purchase):-Each supply lot/batch has to be provided with Certificate of Analysis (quality assurance certificate) otherwise the kit will not be accepted. 14. Should have ICMED 13485 Certification by QCI or IS / ISO 13485 Certification or CE Certificate or US FDA approval Certificate.
11French Chalk
12Glycin Irrigation Fluid
13Haemodialysis Fluid with Bi-Carb
14Hamatoxyllin Eosin Stain Powder
15HsCRP Test Kit
16Hydrogen Peroxide Soln. (20Vol) I.P.
17Indole strip
18KOH Solution 10% L
19Lactate Test Kit
20Liquid Paraffin I.P. (Heavy)
21Magnesium Sulphate I.P.
22MB/BACT Antibiotic Suppliment Kit
23Nitric Acid
24Poly Sodium Citrate
25Primary Antibody ER
26Primary Antibody HER
27Primary Antibody PR
28PT Reagent
29PYR Reagent
30PYR strip
31PPD Tuberculin 5TU/0.1 ml - 5ml
32Ceftizoxime Antibiotic Disc
33Basic Fuchsin
34Chloroform A.G.
35E.D.T.A. Powder
36METHYLENE BLUE Powder
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail