Tender For Rebuild Auwss To Panniyanoor Town And Panoor Mokeri Villages, Kannur-Kerala

Kerala Water Authority-KWA has published Tender For Rebuild Auwss To Panniyanoor Town And Panoor Mokeri Villages. Submission Date for this Tender is 21-03-2023. Pump Supply Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

36824091
Tender For Rebuild Auwss To Panniyanoor Town And Panoor Mokeri Villages
Open Tender
Indian
Kerala
Kannur
21-03-2023

Tender Details

Tender For Rebuild Auwss To Panniyanoor Town And Panoor Mokeri Villages Rebuild Auwss To Panniyanoor Town And Panoor Mokeri Villages Automation Of Vertical Turbine Pumps In Kerala Water Authority Implementation Of Phase 1 Stage2 Part Under Rebuild Kerala Initiative Supply Installation Trial Run And Commissioning Of Cont

Key Value

Document Fees
INR 555 /-
EMD
INR 3178.0 /-
Tender Value
Refer document

BOQ Items

Work Name:REBUILD-AUWSS to Panniyanoor town and Panoor Mokeri villages -Automation of Vertical Turbine pumps in Kerala Water Authority- Implementation of Phase 1 (Stage2), part under Rebuild Kerala Initiative - Supply, installation, trial run and commissioning of Control Module for remote operation of 1 No -30 Hp Vertical Turbine pump sets at Raw water Pump house at pathiPalam -General Electrical Work
Sl. No. Item Description
1cost of Materials and working charges
2OD36971/2022-2023:"od88615/2022_2023 Supply, installation, trial run and commissioning of Control Module for remote operation of 30 HP VT- 1 No pumpsets at Raw Water Pump House at Pathi Palam which is required to automate the start, stop, monitor the operation of VT pump taking care of protection features in situation like over voltage, under voltage, phase changes, single phasing, overload and situations like impeller jam, air lock, foot valve blocked, sump dry. The system should suit for different type of starters like VFD, Soft starter, FCMA, Star-Delta etc*. the input supply to the drive is through 440v, 3.3kv,6.6kv or 11kv, controlled by substations and transformers. The added system shall not interfere with the working of starters negatively and should be of externally fitting type. ThecommunicationshallbebasedonGSMandremoteoperationcommunication,systemstatus communication should be made available for at least 2 users and to HMI dashboard. The pump should be controlled to start in step-by step mode in rpm increase, without causing over current flow/huge rise in ampere (Delivery valve in full open mode with NRV/reflux valve). The system may communicate the status including the number of pumps in operation under an office, running hours, idling time, error logs etc. The new system should go in hand with the future integration with PLC/SCADA and should follow standard universal protocol in communication between systems, so that the pump shall be configurable in the PLC/SCADA and operation updates shall be visible in the HMI of the SCADA System. The system should have a replacement warranty of 5 years against normal machine faults,power flash, memory flash, surge failure, lighting surge failure, harmonic failure etc. Scope of the works includes supply, installation, commissioning & testing of automation system for pumphouses and real time monitoring of the working of pumps without resorting to any manual methods. Proposed Automation system shall be designed, manufactured, installed and tested to ensure the high standards of operational reliability. Instruments mounted in field and on panels shall be suitable for continuous operation. All electronic components shall be adequately rated and circuits shall be designed so that change of component characteristics shall not affect pump operation. Control the pump (ON/OFF) from local panel as well as remotely. Pump can be programmed to start if water is below a set leveland turned Off it reached to Set level . The pump can also be operated on fixed Ptime basis Rdaily, or in oIther woCrds pumpingEhours can be set according to demand 24X7. In case of over current, Phase change and under voltage/over voltage the pump can be turned off. Monitor the pumping time Monitor the Voltage, current, frequency. The motor operation should be compatible on all mobile phone platforms, Android, iOS, Windows, even from normal phone or land phone and with semi automatic star delta. The control module should have the features like high –voltage isolation, high-voltage cut off ,machine surge protection ,software security provision, real time motor parameters without SMS or GPRS through IVRS, dynamic power fault correction, automatic reset facility, starter interlock facility, local HMI with exact error display for local troubleshooting,live local motor parameters display with at least 3 second refresh rate, non bypasse of manual ON- OFF button,dynamic waterhabitstabilization,dynamicconfigurationfacility3phasesindividualinputratedfastblown replaceable fuse control,rated fast blown replaceable fuse control for machine board protection,motor or starter power or technology up gradation facility or compatibility,true manual mode,manual Emergency off provision,auto-Manuel mode interlocks facility,etc."