Tender For Special Repair To Cable And Panel At Certain Location At Af Stn Thoise Under Ge(Af) Thoise
Tender Overview
Project Description
Special Repair To Cable And Panel At Certain Location At Af Stn Thoise Under Ge ( Af ) Thoise
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Apr-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-Apr-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down existing unserviceable worn out XLPE under ground cable of any size and length at any position from complete all as specified and as directed by Engr-in-Charge. |
| 2 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 120.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and as directed by Engr-in-Charge. |
| 3 | XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and as directed by Engr-in-Charge. |
| 4 | XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 70.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and as directed by Engr-in-Charge. |
| 5 | XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 4-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and as directed by Engr-in-Charge. |
| 6 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge. |
| 7 | Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soil complete all as specified and directed by Enginer-in-Charge. |
| 8 | Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for PCC cable coverClass LV, Type I,flat,size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engr-in-Charge.Note:-Excavation and earth work to be measured and paid for separately |
| 10 | Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge.Note: Punned thickness of 18 cm shall be measured for payment. |
| 11 | M&L in repair Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 3.0 mtr deep below normal ground level with top edge of earth plate not less than 2.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protectionpipe 40mm boreand earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge. Note : (i) Excavation work should be done by manpower only.(ii) Earth test should be done bycontractor and if required result is not found then entire earthing should by contractor again and no claim whatsover shall be admissible to contractor. |
| 12 | Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, outdoor, cubical type, floor mounted, factory made, CPRI approved, size 1000x1200x450mm, Al Bus Bar 800 Amps fabricated out of 3.4mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following complete all as specified and as directed by Engr-in-Charge.Incoming:-(a) Change Over Switch 200 Amps -01 Nos(b) MCCB, four pole, 360 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 01 No.(c) MFn MeterV, A, F, kW, KVA, kVAr, kWh, , PF etcMake L&T , Equivelent in Seimns and Schinider -01 Nos Outgoing:-(i)MCCB 4 pole 415 Volts of capacity 200 amps thermal magnetic release adjustable type of breaking capacity 25 KA-02 No (incoming) With addition to Amp meter-02 Nos (ii)TPN 4 pole 415 Volts of capacity 63 amps thermal magnetic release adjustable type of breaking capacity 10 KA-04 Nos (outgoing) With addition to Amp meter-04Nos |
| 13 | Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, outdoor, cubical type, floor mounted, factory made, CPRI approved, size 1000x1200x450mm, Al Bus Bar 800 Amps fabricated out of 3.4mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following complete all as specified and as directed by Engr-in-ChargeIncoming:- (a) Change Over Switch 400 Amps -01 Nos(b) MCCB, four pole, 400 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 03 No ( incl 03 Nos Amp meter).(c) MFn MeterV, A, F, kW, KVA, kVAr, kWh, , PF etcMake L&T , Equivelent in Seimns and Schinider -01 Nos (d) Bus Bar Coupler 4 Pole ACB 630 Amp, 65 KA with Microprocessor Release IPR 1+-01 Nos (e) Suitable Contacter, relay,& circuit protection device Outgoing:-(i)MCCB 4 pole 415 Volts of capacity 63 amps thermal magnetic release adjustable type of breaking capacity 10 KA-04 No (incoming) With addition to Amp meter-04(ii)MCCB 4 pole 415 Volts of capacity 100 amps thermal magnetic release adjustable type of breaking capacity 16 KA-02 Nos (outgoing) With addition to Amp meter-02 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued