Tender For Repair/ Maint Of W/S Distribution Pipes And Joints Control Valves,Repai/Maint Of Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Pedestal Fan,Fitting And Fixtures And Allied Maint Works At Sion,Cotton Green, Pavanika Area At Afs Mumbai Under, thane-Maharashtra

Military Engineer Services-MES has published Tender For Repair/ Maint Of W/S Distribution Pipes And Joints Control Valves,Repai/Maint Of Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Pedestal Fan,Fitting And Fixtures And Allied Maint Works At Sion,Cotton Green, Pavanika Area At Afs Mumbai Under. Submission Date for this Tender is 06-04-2023. Control Valves Tenders in thane Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36723284
Corrigendum : Tender For Repair/ Maint Of W/S Distribution Pipes And Joints Control Valves,Repai/Maint Of Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Pedestal Fan,Fitting And Fixtures And Allied Maint Works At Sion,Cotton Green, Pavanika Area At Afs Mumbai Under
Open Tender
Indian
Maharashtra
thane
06-04-2023

Tender Details

Repair / Maintenance Of W / S Distribution Pipes And Joints Control Valves, Repai / Maint Of Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Pedestal Fan, Fitting And Fixtures And Allied Maint Works At Sion, Cotton Green, Pavanika Area At Afs Mumbai Under Ge Af Thane

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-04-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINT OF WATER SUPPLY DISTRIBUTION PIPESAND JOINTS CONTROL VALVES,REPAI, MAINT OF CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN, PEDESTAL FAN,FITTING AND FIXTURES AND ALLIED WORKS,REPAIRS/ REPLACEMENT OF INTERNAL WIRING, DISTRIBUTION BOARDS, LIGHT FITTINGS, SUBMAIN WIRING INCLUDING FITTINGS AND FIXTURES,REPAIRS/ MAINTENANCE OFHEATING AND COOLING APPLIANCES,REPAIR/MAINTENANCE OF LT CABLES, LT PANELS, & SWITCH GEARS CONNECTED WORKS AT DIFFERENTSUBSTATIONS AT SION,COTTON GREEN, PAVANIKA AREA ATAF STATION MUMBAI UNDER GE (AF) THANE
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out,in soft/loose Soil complete all as specified and directed by Engineer-in-charge..
2Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge..
3Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge..
4Disconnecting ,dismantling and taking down of unserviceable rusted GI water tubing of size 100/ 80 mm from existing place in trenches/wall/floors/ceilings complete all as specified and directed.of the following sizes:-
5All as per item No 4.00 here-in-before but of size 50 mm complete aii as specified and directed.
6All as per item No 4.00 here-in-before but of size 40 mm complete aii as specified and directed.
7All as per item No 4.00 here-in-before but of size 25 mm complete aii as specified and directed.
8All as per item No 4.00 here-in-before but of size 20 mm complete aii as specified and directed.
9All as per item No 4.00 here-in-before but of size 15 mm complete aii as specified and directed.
10Supplying & Laying, connecting and testing GI water tubing pipe 100 mm bore medium grade including all necessary fittings, in trenches complete all as specified and directed.
11All as per item No 10.00 here-in-before but of size 80 mm bore complete all as specified and directed.
12All as per item No 10.00 here-in-before but of size 50 mm bore complete all as specified and directed.
13All as per item No 10.00here-in-before but of size 40 mm bore complete all as specified and directed.
14All as per item No 10.00 here-in-before but of size 25 mm bore complete all as specified and directed.
15All as per item No 10.00 here-in-before but of size 20 mm bore complete all as specified and directed.
16All as per item No 10.00 here-in-before but of size 15 mm bore complete all as specified and directed.
17Supplying & Laying, connecting and testing GI Pipe 100 mm bore medium grade including necessary fittings to walls and ceiling or laid in floorincluding all fixing accessories complete all as specified and directed.
18All as per item No 17.00 here-in-before but of size 80 mm bore complete all as specified and directed.
19All as per item No 17.00 here-in-before but of size 50 mm bore complete all as specified and directed.
20All as per item No 17.00 here-in-before but of size 40 mm bore complete all as specified and directed.
21All as per item No 17.00 here-in-before but of size 25 mm bore complete all as specified and directed.
22All as per item No 17.00 here-in-before but of size 20 mm bore complete all as specified and directed.
23All as per item No 17.00 here-in-before but of size 15 mm bore complete all as specified and directed.
24Supply, laying, and fixing of Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" of size 150mm with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed.
25Dismantling and taking out unserviceable Sluice Valveof size 80 mmbore from line complete all as directed.
26Dismantling and taking out unserviceable Sluice Valveof size100 mm bore from line complete all as directed.
27Supply and fix in repairs Sluice Valve Class PN 1.6,80 mm dia with iron wheel head, gaskets nuts, bolts,washerscomplete all as directed.
28Supply and fix in repairs Sluice Valve Class PN 1.6,100 mm dia with iron wheel head, gaskets nuts, bolts,washerscomplete all as directed.
29Dismantling and taking out unserviceable gun metal gate valve of size 50 mm to 40 mm bore from line complete all as specified and as directed.
30Dismantling and taking out unserviceable gun metal gate valve/stop valve of size 25 mm to 20 mm complete all as specified and as directed.
31Supply and fixgun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsize 50 mm dia complete all as specified and as directed.
32Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsize 40 mm dia complete all as specified and as directed.
33Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsize 25 mm dia complete all as specified and as directed.
34Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsizes 20 mm dia complete all as specified and as directed.
35Dismantling damage and broken valve chamber of size 1200x1200x900mm including unserviceable rusted MS cover complete without disturbingthe existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 502x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed.
36All as per item no 35.00 here-in-before but of size 900 mm X 900 mm X 900 mm internal complete all as specified and directed.
37Material and Labour for PCC (1:2:4) type B-1 for supporting pillar posts for pipes/flooring/pavings / foundation for motor etc complete all as specified and directed.
38Material and Labour for brick work with subclass B bricks in cement mortar 1 : 4 , straight or curved on plan exc 6m mean radius built in including taking down unserviceable bricks complete all as specified and directed.
39Material and Labour for cutting bituminous surfaces road to a depth of n exc 60cm and not exceeding 60cm in width for taking out or laying of GI tubing and refilling the same with necessary making good works complete all as specified and as directed.
40Demolition and dismantling of Cement concrete of any description and in any position and removing the materials to a distance not exceeding 100 m complete all as specified and as directed.
41Material. fabricated, and errection for base frame / Iron Ladder/Duct coversofUG Tank / OH Tank for centrufugal pumpset fabricated out of structural steel sections such as joint, hannel, angle, or tee sections including grouting nuts bolts, washers , checknuts etc and painting the frame with two coats of rust proof paint over a coat of zinc primerincluding dismantling and taking down rusted steel items from existing places complete all as specified and as directed.
42Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation towork shop of3 to 5 HP pumping setfor repairs/ rewinding.Dismantling the pumpset complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts,dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enameled copper winding wire of same guage varnishing the stator & drying in oven reassembling the pumpset complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing complete all as directed.
43All as per item No 42.00 herein but for motor of capacity7.5 HP complete all as directed.
44Supply and fixing in repairs fully automatic DOL starter suitable for 3 to 5 HP Pumping set415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T or eqvivalent”
45Supply and fixing in repairs fully automatic DOL starter suitable for 7.5 HP Pumping set415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T / or eqvivalent ”
46Supply and fixingin repairsContactor ML-33 Pole with DC Coilsuitable for 3 to 5 HP415 volts 3 phase motor including taking down existing contactos complete all as directed.
47Supply and fixingin repairsContactor ML-33 Pole with DC Coilsuitable for 7.5 HP415 volts 3 phase motor including taking down existing contactos complete all as directed.
48S & FSingle Phase Preventerfor motor protection Circuit Breaker up to 7.5 HP Motor including taking down existing all as specified & directed.
49Supply and Fix in repairs foot valve of Brass of Size 80 MM Dia complete all as specified and directed.
50Supply and fixing in repair of Ductile Iron pipe bends (any type, radius and angle) tapers any type (Straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross (socket and spigot type) for dia of pipe 150 mm bore all as directed.
51M&L for Cleaning of RCC UG sumps of 7000 Gallon capacities by involvingof the followings 08(Eight) stage of cleaning process complete all as specified and directed (i)De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii)Cleaning of walls, floors, ceiling etc complete (iv)Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Tratment of inside of tank which effective againstall pathogens all complete. (vi) Applying one coat of white wash internal surfaces. (vii)Replacenylon net for vent pipes &man hole cover (viii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :-The tendere shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 1000/- per day.
52Ditto as per Srl Item No 51.00 above but UG sumps of 10000 Gallon capacity
53Ditto as per Srl Item No 51.00 above but UG sumps of20000/35000 Gallon capacity
54M&L for Cleaning ofRCC Over Head Tanks of 15000/20000 Gallon capacities by involvingof the followings 07(SEVEN) stage of cleaning process complete all as specified and directed (i)De-watering by all complete (ii) Removal of sludge fromRCC Over Head Tanks (iii)Cleaning of walls, floors, ceiling etc all complete (iv)Removing dirt and sludge by vacuum pump (v) Applying one coat of white wash internaL surfaces. (vi)Replacenylon net for vent pipes &man hole cover (vii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etcNote :-The tendere shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :- (i) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (ii) Material removed from the tank shall be disposed off at out side. (iii) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 1000/- per day. (iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots,Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.
55Monthly Visit for checking any defects for automotion of water pumping installation and kept it in 100% serviceable condition at all times. And carry out under mentioned works at pump house of AF station Sion & Cotttongreen a) Testing, Checking and setting if required duty cycle for operation of pumps and set cycles as per pumping timings of installation b) Check of PLC Panels display, for in auto manual operation of Pumps, Actuators c) Checking of Push button, ON -OFF switches, Selector switches on PLC Panels for various mode of operation d) Checking all the connection of communication cables inside the PLC Panels and at end termination for any damge or Loose connection. e) Checking of Preesure switches, Solenoid valves, Magnetic water level sensors for their healty operation of Automation system f) Checking of MIMIC Panels for proper display of water level indication of water level in sump and over head tank. g) Checking of all butterfly valves for smooth operation and water lekage h) Chekcing of PLC realy for healty operation and carry necessary setting if required i) Cheking of moter for smooth operation of actuator and operating mechanisum of motorised butterfly valves j) Checking auto Priming system operation for priming of Pumps, all as specified and directed.
56M & L for chemical analysis of water from OHT & UG Sump from govt approved testing lab all as specified and directed.
57Servicing of Pressure Switch i.e. disconnecting of electrical connections, removing, cleaning, greasing, oiling, refixing, reconnecting of electrical connections and testing. Note: Spares shall be paid seperately as supply only under relevent item Sch A.
58Servicing of Solenoid Valve of size 10mm/15mm dia. i.e. disconnecting of electrical connections, removing, cleaning, greasing, oiling, refixing, reconnecting of electrical connections and testing. Note: Spares shall be paid seperately as supply only under relevent item Sch A.
59Servicing of Magnetic Level Sensor i.e. disconnecting of electrical connections, removing, cleaning, refixing, reconnecting of electrical connections and testing all as specified and directed. Note: Spares shall be paid seperately as supply only under relevent item Sch A
60Servicing of Motorized valve of size 50/80/100/150mm dia. i.e. disconnecting of electrical connections, removing, cleaning, greasing, oiling, refixing, reconnecting of electrical connections and testing, all as specified and directed. Note: Spares shall be paid seperately as supply only under relevent item Sch A.
61Servicing of Butterfly valve of size 50/80/100/150mm dia. i.e. disconnecting of electrical connections, removing, cleaning, greasing, oiling, refixing, reconnecting of electrical connections and testing. all as specified and directed. Note: Spares shall be paid seperately as supply only under relevent item Sch A.
62Suppy & Fixing on repairof Single Phasing Preventor all as specified and directed. Model: VSP D2 Make: Minilec or eqvivalent
63Supply & Fixing in repair of Magnetic Level Sensor all as specified and directed.
64Supply & Fixing in repair of Push Button with LED indicator - 240V AC. Color: Red/Yellow/Green. all as specified and directed. Make: Telemecanique/Schneider/ or eqvivalent
65Supply & Fixing in repair of LED indicator - 240V AC. Color: Blue. all as specified and directed. Make: Telemecanique/Schneider/ or eqvivalent
66Supply & Fixing in repair of 100mm dia. Aquaseal Wafer Type C. I. Butterfly Valve PN 10 with Flow Control Lever having Nylon Coated C.I. Disc & Nitrile Rubber Lining IBR including rubber/champion packing, Nut-Bolts, etc. all as specified and directed. Make: L&T/Audco or equivalent
67Supply & Fixing in repair of Single Phase Electric Actuator suitable for 100mm. dia. Butterfly valve . limit switches for Open/Close condition with valve position indicatorall as specified and directed.. Make: Marsh/SD Tork/Rotork/ or eqvivalent
68Supply & Fixing in repair of Relay with Base - 4 C/O, 240V ACall as specified and directed.. Make : Idec/Leon/ or eqvivalent
69Supply & Fixing in repair of 2/3 Position Selector Switchall as specified and directed.. Make : Telemecanique/Schneider/Esbee/or eqvivalent
70Supply & Fixing in repairof NO/NC Contact - 240V AC, 3A. all as specified and directed. Make : Telemecanique/Schneider/Esbee/ or eqvivalent
71Supply & Fixing in repair of Water Level Controller Relay Card (05 levels)all as specified and directed. Make: ME/RDS or equivalent
72Supply & Fixing in reapir of Coil for Solenoid Valve - 10mm/15mm 230V ACall as specified and directed.. Make : Avcon/Johnson Control/ or eqvivalent
73Supply & Fixing in reapirof Pressure Switch, Range1-10 Kg/cm2all as specified and directed.
74Supply & Fixing in repairof Pressure Guage, Range 0-10 Kg/cm2all as specified and directed.
75Supply & Fixing in repair of Capacitor for Actuator suitable for 50mm/80mm/100mm/150mm dia. Butterfly Valveall as specified and directed.
76Supply & Fixing in repair of Aluminium Housed Power Resistor for Actuator suitable for 50mm/80mm/100mm/150mm dia Butterfly Valveall as specified and directed.
77Supply & Fixing in repair of Limit Switch for Actuator suitable for 50mm/80mm/100mm/150mm dia Butterfly Valveall as specified and directed.
78Supply & Fixing in repair of Switch Mode Power Supply (SMPS) 24V DC 5Aall as specified and directed.. Make:Telemecanique/NHP/Schneider/ or eqvivalent
79Supply & Fixing in repair of Programmable Logic Controller (PLC) with Digital Input, Transistor Output, RS 232/485 Communication Port. Model: M91-2-T1/M91-2-T38all as specified and directed.Make: Unitronics/Mitsubishi or equivalent
80Supply & Fixing in repair of 5 pair 0.5 mm dia. Telephone copper armoured cable for sensorall as specified and directed.
81Supply & Fixing in repair of 6 Core 1.5 sq. mm PVC sheathed PVC insulated copper armoured cableall as specified and directed.
82Supply & Fixing in repair of 4 Core 1.5sq.mm. PVC sheath PVC insulated copper armoured cableall as specified and directed.
83Supply & Fixing in repair of 2 Core 1.5sq.mm. PVC sheath PVC insulated copper armoured cableall as specified and directed..
84M&L for checking Serviceability ofceiling fan/ exhaust fan/wall fan/pedestal fanfor smooth &safe functioning at site, including checking of nut bolt & washer, quarter pin & tightening up, replacment as requiredcomplete all as directed by Engineer-in-Chargeat site Note: 1. Record shall be maintained for fan checked at siteand be submitted to the AGE E/M. 2. In case fan shall be not found to be safe & smoot then it has to be taken down immediately. Taking down & repair to be measured & paid separately.
85Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades, canopy, down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector complete all as specified and directed.
86Material and labourfor Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge.of the following:-
87Ceiling fan 1200 / 1400 mm Sweepcomplete all as specified and directed.
88Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweepcomplete all as specified and directed..
89Exhaust Fan, Pedastal fan,wall fan, 380 / 450 mm Sweepcomplete all as specified and directed.
90Material and labour Painting onlyof ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, scraping out of old paint filling of cavities with filler preparationof body and clearing of dust etc Painting by Spray with first Quality Paint includingrewriting ofMES number complete for allas directed
91Material and labour Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep Oiling, Greasing including removing all dust and replacement of Split Pin and Bolts, Nuts and Screwscomplete all as specified and directed.. Note : Spares shall be measured & paidin respectiveitem of this sch.
92Supply & fix in Repairfollowing spare parts for repairing of fans :-
93Capacitor up to 2.5 mfd 230 volts ACcomplete all as specified and directed.
94Capacitor4.0 mfd, 230 volts, AC complete all as specified and directed.
95Capacitor Clamp with Connector As Par Sample complete all as specified and directed.
96Rubber Insulator sutiablefor any type ofCeiling Fancomplete all as specified and directed..
97Mild steel Down Rod with Clamp nut bolts & split pin for 600 mm Longas par samplecomplete all as specified and directed.
98Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par samplecomplete all as specified and directed.
99Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete 300 mm sweep as par samplecomplete all as specified and directed.
100Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete380/ 450 mm sweep as par samplecomplete all as specified and directed.
101Ball bearing sutiable for any type of fanscomplete all as specified and directed.
102Gun Metal bush as per sample sutiable for any type of fanscomplete all as specified and directed.
103Mild steel shaft as per sample for any fancomplete all as specified and directed.
104Ceiling Fan Blade suitable for 1200/1400 mm sweep as per samplecomplete all as specified and directed..
105Exhaust Fan Blade suitable for 300 mm sweep as per samplecomplete all as specified and directed..
106Exhaust Fan Blade suitable for 450 mm sweep as per samplecomplete all as specified and directed..
107Ceiling fan Canopy Set of Two as par sample complete all as specified and directed.
108Supply & Fix in Repair wall fan regulator as per samplecomplete all as specified and directed.
109Supply & Fix in RepairExhaust fan louvers with Wire mesh of size 450mm sweepcomplete all as specified and directed.
110Supply & Fix in RepairExhaust fan louvers with wire mesh of size 300 mm sweepcomplete all as specified and directed.
111Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose"s lamp holder from existing batten PVCconduit/steel conduit / PVC casing and capping wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match all as specified and directed by Engr-in-Charge.
112Taking down main Switches,MCB DB with MCBs complete all as specified and directed.
113Taking down sub main wiring ofany sizes complete all as specified and directed.
114M & L for point wiring withFRLS insulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable ofsize 1.5 Sqmm green colour Connected to common earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers all as specified for the following :-
115(i) One light / fan/bell point controlled by one way switch
116(ii) One socket outlet 5 Amps on independent board
117(iii) One socket outlet 5 Amps on the same board
118M & L for point wiring with FRLSinsulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC conduit and accessories, concealed in wall conduit on ceiling (for fan/downlighter only) etc with necessary fixing accessories and earth continuity conductor cable ofsize 1.5 Sqmm green colour Connected to common earth and earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers including making good the disturbed surface and painting the surface with color matching to the wall color all as specified for the following :-
119(i) One light / fan/bell point controlled by one way switch
120(ii) One socket outlet 5 Amps on independent board
121(iii) One socket outlet 5 Amps on the same board
122All as per Sl item No 100herein before butwith 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed
123All as per Sl item No 100herein before butwith 4 Sqmm for phase & neutral and 4 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed
124Supply and Fix in repairsofSwitch piano flush type single pole one way 5 Amp complete all as specified and directed .
125Supply and Fix in repairs ofCeiling rose surface bakelitetwo to three terminal complete all as specified and directed .
126Supply and Fix in repairs of Fan regulator electronic step type 240 V complete all as specified and directed .
127Supply and Fix in repairs of Bell push flush type 5 Amps complete all as specified and directed .
128Supply and Fix in repairsof Electronic CallBell 230 volts single pole AC complete all as specified and directed .
129Supply and Fix in repairs of Switch socket combined two in one 06 pin 5/15 Amps flush type universal complete all as specified and directed .
130Supply and Fix in repairsofSwitch Socket multipurpose 5 pin 5 Amps 240 V flush type complete all as specified and directed .
131Supply and Fix in repairs ofLamp holder,insulated body with back plate complete all as specified and directed
132M&L MCCB DB verticle type made of sheet steel , powder painted with neutal bus bar 200 A, neutral link,IP-30-IK08 protection grade , 415Volts TPN with 8 way Double door complete all as specified and directed.
133M&L MCCB DB verticle type made of sheet steel , powder painted with neutralbus bar 200 A, neutral link,IP-30-IK08 protection grade , 415Volts TPN with 4 way Double door complete all as specified and directed
134M&L MCCB TPN 100 Amps , 415Volts, 25KA ,3 Polecomplete all as specified and directed
135M&L MCCB TPN 160 Amps , 415Volts, 25KA ,3 pole complete all as specified and directed
136Supply and Fix in repairsof MCB DB SPN 8 Way Double door type 240 Volts complete all as specified and directed. NOTE FOR ITEM NO 115 to 122 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB tobe fixed on wall including framemade out of MS flat 40x5mm(2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. .
137Supply and Fix in repairs of MCB DB TPN 4 Waydouble door type 415 V with bus bar complete all as specified and directed
138Supply and Fix in repairs single pole and neutral enclouser with a two pin and earth and metal clad plug socket complete with one single pole MCB 25 Amp 240 Volts complete all as specified and directed.
139Supply and Fix in repairsofMCB TPN 63 Amps 415 Volts complete all as specified and directed .
140Supply and Fix in repairs of MCB SP 06 to 32 Amps 240 Volts complete all as specified and directed .
141Supply and Fix in repairsof SPN 6- 32 Amps 240 Volts complete all as specified and directed .
142Supply and Fix in repairs of MCB SPN 40 Amps 240 Volts complete all as specified and directed
143Supply and Fix in repairs of MCB SPN 63 Amps 240 Volts complete all as specified and directed .
144M&L for Sub Mainwiring with two single core 2.5 SqmmFRLS insulated multistranded flexible copper conductor cable 660/1100 volts gradedrawn in through rigid flexible PVC casing -n- caping/PVC conduit with and including PVC insulated 2.5 Sqmm single core multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly all as specified and as directed. Note:- 1. Two runs of cable and one run of earth wire incl PVC conduit will be measured and paid one unit. 2. Separate sub main wiring will be run for each accn
145M&L for Sub Main wiring complete with 4.0 Sqmm FRLS insulated1100 Volt grade with multistranded copper conductor cable with and including drawn through PVC casing -n- caping/PVC conduitwith all accessories fixed on Walls/floors/roofs with and including pressed steel terminal sunken boxes fixed on the existing sunken portion (Where the old boxes are removed under respective item) with 3 mm laminated bakelite sheet top cover fixed with cadmium plated screws,cup washer for housing metal clad plug socket for ACPoint including provision of 4 sqmm PVC insulated copper wire as earth continuity conductor and connecting to common earth dolly all as specified.
146All as per item No. 124.00 herein before but with 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable drawn in through PVC casing -n- caping/PVC conduitcomplete with all accessories including provision of 6.0 sq mm FRLS insulated copper wire as earth continuity conductor all as specified and as directed.
147M & L for maintenance free chemical Gel based earthing, Pure Copper typehaving 50 mm dia 3 mtr long GI pipe(Wall thickness of 3.2 mm) and 7.50 m long Copper strip earthing electrode of size 25 x 3 mm with 60 Kg ENNOV back fill compound , Model No ELE-350-CU of INNOV Infra Solution Ltd including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade, PCC Chamber 1: 3 :6 type C1 ( for even finish on both the faces ) and RCC cover 1:2:4 type B1, 550 x 550 x 50 mm thick with 8 mm dia TMT bars 150 mm c/cboth ways with 2 Nos ofhandles of 10 mm dia all as required at siteincluding testing on completion and taking down of old earthing all as directed by Engr in-Charge Note : (1) 7.50 RM GI earth strip including GI pipe light grade isdeemed to be included in the quoted rates, beyond 7.50 RMshall be measured and paid separately. (2) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost.
148Supply and fixing in repair building security light LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
149S & F LED retrofit lamp B-22 holder based with polycarbonate bodyand aluminium heat sink with warm white, 9W LED Lamp,all as specified and as directed by Engr-in-Charge at site
150S&F energy efficient light emmitting LED light fitting 1x 18/20 watt, four feet , white fittings with LED rod complete with all accessories & Provn ofthree core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed
151S&F for energy efficient light emmitting LED light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories& Provn ofthree core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed
152S&F in Repairs LED Light luminariesSquare type 36W suitable suitable for Modular/pop/Gypsum ceiling with starter, connector block, etc,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible conductor of copper withPVC square blocks of size 600mmX600mm for fixing the fitting complete all as specified and directed.
153Material and labour Modular white cover plate with frame of following types complete all as specified and directed
154White cover plate with frame, 1 module
155White cover plate with frame 2 module
156White cover plate with frame 4 module
157White cover plate with frame 6 module
158White cover plate with frame 8 module
159Material and labour Modular switch 1 way 6A, 1 module complete all as specified and directed.
160Material and labour Modular Bell push, flush type, 5 ampcomplete all as specified and directed.
161Material and labour Fan step regulator, 120W - 2 module complete all as specified and directed.
162Material and labour Mouduler metal box flushtype 1 /2/3 module complete all as pecified and directed.
163Material and labour Mouduler metal box flushtype 4 module complete all as specified and directed.
164Material and labour Mouduler metal box flushtype 6 module complete all as specified and directed.
165Material and labour Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 16 Amps complete all as specified and directed.
166M&L for periodical Servicing of Air conditioner Splittype of capacities 1.5 to 2.0 TR complete with dismantlinginternal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectificationto wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories,reallignment of the fan coil unit and replacement of drain / condense pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job all as specified and directed.
167All as per Item No 140.00 here in before but for Airconditioner window type of capacity 1.5 TR all as specified and directed.
168Supply and fix only the followingspares incorporated during the repairs to Air conditioner Split / Window type vide Sl Item No 140.00 here- in- before but Supply and fix only Capacitor for AC 1.5 TR - 2.0 TR all as specified and directed.
169Supply and fix in repairs only Capacitor for Condensing Fan Motor all as specified and directed.
170Supply and fix in repairs only Starting Relayall as specified and directed.
171Supply and fix in repairs only Evaporator Fan / Blower for for WindowAC all as specified and directed.
172Supply and fix in repairs only Printed Circuit board for inverter split AC as per sample all as specified and directed.
173Supply and fix in repairs only Filter Drier all as specified and directed.
174Supply and fix in repairs only Condenser Fan Motor for split AC 1.5 TR all as specified and directed.
175Supply and fix in repairs only Condenser Fan Motor for split AC 2 .0 TR
176Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 2.0 TR all as specified and directed.
177Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 1.5 TR all as specified and directed.
178Supply and fix in repairs only Condensor Unit for air conditioner all as specified and directed.
179Supply and fix in repairs only Blower motor for Split type AC as per sample all as specified and directed.
180Supply and fix in repairs only Condenser Fan Motor for Window ACAs per Sample all as specified and directed.
181Supply and fix in repairs only Thermostat Switch all as specified and directed.
182Supply and fix in repairs only Swing motor for Split AC all as specified and directed.
183Supply and fix in repairs only Evaporator Fan / Blower for for Split AC all as specified and directed.
184Supply and fix in repairs only Cooling Coil all as specified and directed.
185Supply and fix in repairs only Over Load Protection Coil all as specified and directed.
186Supply and fix in repairs only Copper Capillary tube of Air Conditioner all as specified and directed.
187Supply& fix in repair including taking down old one out door unitcabinets with out compressor for split type AC ofcapacity for AC 1.5 TR all as specified and directed.
188Supply& fix in repair including taking down old one out door unitcabinets with out compressor for split type AC ofcapacity for AC 2.0 TR all as specified and directed.
189Supply& fix in repair including taking down old one indoor unit for split type AC ofcapacity for AC 1.5 TR all as specified and directed.
190Supply& fix in repair including taking down old one indoor unit for split type AC ofcapacity for AC 2.0 TR all as specified and directed.
191M&L for periodical repairs and maintenance of water cooler of cooling capacity upto40 /60 Ltrs / Hr and storage capacity upto 80 /120 Ltrs complete with disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc.Checking up and rectificationto wiring and connections, replacement of necessary parts and accessories, cleaning of the cold water tank, piping, refrigerant lines, reallignment of the fan coil unit and replacement of drain pipe , connecting to water mains and testing to make the unit in fully functional condition. Note: 1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labor Charge for On site repairs is deemed to be included in the quoted rate of the job.all as specified and directed.
192Supply and fix in repairs onlythe spares incorporated during the repairs to Water Cooler vide Sl Item No.165.00 herein before but Thermostatswitch with knob
193Supply and fix in repairs only Push tap inner / outer thread chromimum plated of size 1/2 ".all as specified and directed.
194Supply and fix in repairs only Rubber gasket with PVC sheet for Top Lid all as specified and directed.
195Supply and fix in repairs only Condenser fan motor for water cooler.all as specified and directed.
196Supply and fix in repairs only Capacitor for water cooler all as specified and directed.
197Supply and fix in repairs only Starting Relay as per Sample all as specified and directed.
198Supply and fix in repairs only PVC Hose Pipe size 3/4 " to 1 " all as specified and directed.
199Supply and fix in repairs only Waste water tray as per sample all as specified and directed.
200Supply and fix in repairs only Compressor Sealed unit for water cooler of capacity upto 120Ltrs all as specified and directed.
201Supply and fix in repairs only Condenser unit for water cooler all as specified and directed.
202Supply and fix in repairs only Overload protection for Water cooler all as specified and directed.
203Supply and fix in repairs only Capillary tube of water cooler all as specified and directed.
204S & Fix in repairs ball brass valves, high pressure with Polyethylene float and flynut complete screwed for Iron pipe on or brass ferrule and fixed of size 15 mm dia all as specified and directed.
205Supply and fixing in repairsSheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 32 Amps 240 Volts all as specified and directed.
206S&F in repairs stop gun metal gate or globe valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia.all as specified and directed.
207Taking down geyser of capacity 25 to 50 Ltrs from the location after disconnecting electric and water connection carefully and sealing cable ends and water pipe for repair or removing to store for safe custody & stripping down, testing of tank, and connecting up carrying out repairs complete all as directed by EIC at site. Note: 1. Equipment Shall be serviced once ina Month and no repeat maintenance shall be measured. 2. Spare replaced during the process of repair shall be measured and paid separatelyas a supply only under relevant item here-in after.all as specified and directed.
208Supply and installin repair including taking down old one water heater storage type of capacity 25 liters glass lined coated inner tank, suitable for high pressure and pressure pump installation 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed.
209Supply and install in repairincluding taking down old one water heater storage type of capacity 50 liters glass lined coated inner tank, suitable for high pressure and pressure pump installatrion 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC.
210Supply and fix only the sparesincorporated during the repair to geysers vide Sl Item no 184.00 herein before for Heating Coil 2 KW all as specified and directed.
211Supply and fix in repairs only Heating Coil 1.5 KW all as specified and directed.
212Supply and fix in repairs onlyThermostat all as specified and directed.
213Supply and fix in repairs only Copper Water tank for Geyser of capacity upto 25 Ltrs all as specified and directed.
214Supply and fix in repairs only Non return valve Brass Chromium plated 15 mm / 20 mm all as specified and directed.
215Supply and fix in repairs only Safety valve with anti vacuum pressure reducing HPRV all as specified and directed.
216Supply and fixing of PVC Cable entry tray of size 100 MM X 75 MM for entry of copper capillary tube and PVC hose pipe of water all as specified and directed. .
217S & F in repair ac stand outdoor unit as per sample all as directed all as specified and directed..
218M & L for refrigent charging /Top up to Air conditioners/water coolers complete all as directed and specified.
219Supply and fixing in repairs of insulation over and aroundcopper tubing to be fitted across the whole length of copper tubing incl all fixing arrangements and checking for insulation leakages if any all as directed
220M&L for periodical Servicing ofRefrigerator of any capacities complete with dismantlinginternal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectificationto wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories,reallignment of the fan coil unit and replacement of drain / condensate pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job
221S & F in repair of freezer basket as per sample all as directed.
222S & F in repair of refrigerator locks as per sample all as directed.
223S & F in repair of refrigerator bulb as per sample all as directed.
224S & F in repair of handle as per sample all as directed.
225S & F in repair of defrost heater as per sample all as directed.
226S & F in repair of condensor coil of refrigerator as per sample.all as directed.
227S & F in repair of evaporator of refrigerator as per sampleall as directed.
228Supply and fix copper pipe of size 5/8 all as directed.
229Supply and fix copper pipe of size 1/4 all as directed.
230Supply and fix copper pipe of size 1/2 all as directed.
231Supply and fix NRV copper of size 1/4 and 1/2 all as directed.
232Supply and fix NRV Copper of size 5/8 all as directed.
233Supply and fix PVC Drain pipe of suitable Size all as directed.
234Supply and fix remote control for Splt AC all as directed.
235M&L for providing crushed stone sand cushioning to UG cable including punning down of sand in layers complete all as specified and directed
236Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mmduring excation of trenches and relaying after cable laying in trenches all asspecified and directed
237Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches complete all as specified and directed
238Taking downGI pipelaying in trenches for UG cable protectionof any sizes pipe complete all as specified and as diercted.
239Supply and lay in trenches / along the wall / floorpipes GI light grade of size 50 mm with and including all fittings and accessories for cable protectioncomplete all as specified and directed
240Supply and lay in trenches / along the wall / floorpipes GI light grade of size 80 mm with and including all fittings and accessoriesfor cable protection complete all as specified and directed
241Taking downany sizes ofof LT UG cable XLPE with aluminum conductor multistranded ,PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable complete all as specified and as directed.
242Supply and lay cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed.
243Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed.
244Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sq mm 3.5 Core complete all as specified and directed.
245Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sq mm 3.5 Core complete all as specified and directed.
246Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sq mm 3.5 Core complete all as specified and directed.
247Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 70 sq mm 3.5 Core complete all as specified and directed.
248S&F Cable jointing kit for 1100V (Earthed) grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
249M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6 including removal of surplus soil complete all as specified and directed.
250Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA,etcincluding suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directed.
251Demolation of Cement concrete in ground floor and paving exc 15 cm thickness but aboveground level including removal all as specified.
252M&L for PCC (1:3:6)type B1 (using 20 mm graded stone aggregate as in sub base to floor 100 mm thick finished even and smooth without using extra cement complete all as specified and directed.
253Supply andin repairs MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door all as specified and directed by engr in charge
254Supply in repair MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door ,all as specified and directed by engr in charge
255Taking down any type any breaking capacity MCCB complete all as specified and as directed as Engineer-in-charge.
256S & F in replacement MCCB 415 volts grade with adjustable short circuit and over load of following rating :-
25763 Amps, 25 KA, 3 Pole
258100 Amps, 25 KA, 3 Pole
259125 Amps, 25 KA, 3Pole
260160 Amps, 36 KA, 3 Pole
261200 Amps, 36KA, 3 Pole
262250 Amps, 36 KA, 3 Pole
263400 Amps, 36 KA, 3 Pole
264M&L for MS chequered plates Fe 410-W (Gde E- 250) Quality "A" of not less than 6 mm thick ofsizes as per site requirement incl cutting , welding of strip on the edges for proper fixing and provn ofhandles for lifting & fixing arrangementas shown & directed.incltaking out the old & unserviceble chequered plates all as directed.
265Material and Labour scrapping to existing LT Panels/ Feeder pillar boxes of out side surfaces and applying two coats of synthetic enamelled paint on out side/ exposed surfaces of LT panels and LT feeder pillar boxes and including cleaning of Metering equipement system,Indication lamps,selector switches etc complete all as specified and directed by Engineer-in-Charge
266Material and Labour for repairing of LT Panelof not exc of sizes 2.5 Mtr x 2 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge
267Material and Labour for repairing of LT Panelof not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
268Material and Labour for repairing of feeder pillar boxof not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
269Supply in repair LED indication lamp for indication of (R,Y,B) 230 Volts includingconnections and taking out unserviceable indication Lamp complete all as specified and directed.
270Supply in repair Volt meter 0-500 Voltdigital type includingconnections and taking out unserviceable Volt meter complete all as specified and directed
271Supply in repair Ampere meter 0-400Amps digital type includingconnections and taking out unserviceable Ampere meter complete all as specified and directed
272Supply in repair Selector switch for Volt meter4 way Knob type (0FF, RB,RY,BY) includingconnections and taking out unserviceable selector switch complete all as specified and directed
273Supply in repair Selector switch for Amp meter 4 way (0FF,R,Y,B) Knob type includingconnections and taking out unserviceable selector switch complete all as specified and directed
274S&F copper cable flexiblePVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engr-in-Charge
275Supply in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr in charge.
276Supply in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.all as specified and directed by Engr in charge.
277Supply in repair garden bollardLED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.all as specified and directed by Engr in charge.