| 1 | Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1 KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. |
| 2 | 4 X 16 Sq.mm |
| 3 | 4 X 10 Sq.mm |
| 4 | 3 X 10 Sq.mm |
| 5 | 3 X 6 Sq.mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 7 | upto 35 Sq.mm |
| 8 | Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required. |
| 9 | upto 35 Sq.mm(Clamped with 1 mm thick saddle) |
| 10 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 11 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 12 | 100 mm dia |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 14 | Upto 35 sq. mm |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 16 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bellnpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 18 | Group C |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 20 | 5/6 A switch |
| 21 | 3 pin 5/6 A socket outlet |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 23 | 3 x 4 sq. mm |
| 24 | 3 x 2.5 sq. mm |
| 25 | 3 x 1.5 sq. mm |
| 26 | 6 x 1.5 sq. mm |
| 27 | 9 x 1.5 sq. mm |
| 28 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 29 | 20 mm |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) |
| 31 | 6 way , Double door |
| 32 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | 4 way (4 + 12), Double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Single pole |
| 36 | Single pole and neutral |
| 37 | Triple pole and neutral |
| 38 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 39 | Supply,installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for twin T8 LED Tube etc.at the site of work.(ISI certified ) |
| 40 | Supply,installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube etc.at the site of work.(ISI certified) |
| 41 | Supply, installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire(IP 66) with polycarbonate housing and diffuser suitable for single 4 ft T8 tube etc.at the site of work.(ISI certified) |
| 42 | Supplying, installation, Testing and commissioning of 70 watt LED type Well Glass Light in pressure die-cast aluminium housing and fixing on truss /wall/pole with suitable clamps and nut bolts(ISI certified ) .. (RatingIP66,Luminare efficacy>120Lm/W,CRI>75, ). |
| 43 | Supplying, installation, Testing and commissioning of 40 watt LED type Well Glass Light in pressure die-cast aluminium housing and fixing on truss /wall/ pole with suitable clamps and nut bolts(NABL certified as per ISO/IEC specification) .. (RatingIP66,Luminare efficacy>120Lm/W,CRI>75, ). |
| 44 | Supplying, installation, Testing and commissioning of40W LED Street light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required(ISI certified). (RatingIP66,Luminare efficacy>120Lm/W,CRI>75, ). |
| 45 | Supplying, installation, Testing and commissioning of70W LED Street light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.(ISI certified) |
| 46 | Supplying, installation, Testing and commissioning of200W LED flood light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.(ISI certified) |
| 47 | Removing, Checking, installation and refixing of Phillips make 36W,0.16 A,240 V Xitanium Driver in the existing 40 W LED Well glass light fitting including giving connection etc. at site of work as required. . |
| 48 | Supplying, installation, testing andcommissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC) motor, class of insulation: B, 3 no.s blades, 30 cm long down rod, 2 no.s canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230v, 50Hz, single phase AC supply, earthing etc. complete as required. |
| 49 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 50 | Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. |
| 51 | Supplying and fixing of Hot press moulded SMC junction Box of size 140x140x95 with 6A SP MCB, 2/4 way strip connector including testing commissioning etc. as reqd. |
| 52 | Removing and Refixing of existing LED batten on Surface/truss with suitable clamps ,nut and bolts etc. including giving connections etc. at site of work as required. |
| 53 | Removing of existing LED Well glass light/LED street light from surface/truss and Refixingthem on Godowns, ancillary buildings with suitable clamps ,nut and bolts etc. including giving connections etc. at site of work as required. |
| 54 | Supplying , installation, testing and commissioning of 35Watt LED 5700K Post top Lanthern of new generation, energy saving, environmental friendly, long life astheticatly design symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etcat site of required (ISI certified) |
| 55 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 56 | 4 X 16 sq. mm (28mm) |
| 57 | 4 X 10 sq. mm (25mm) |
| 58 | 3 X 10 sq. mm (22mm) |
| 59 | 2 X 10 sq. mm (19mm) |
| 60 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 61 | Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 62 | Supplying of 7m high hot dip galvanized octagonal street light pole with 70 mm top dia, 130 mm bottom dia, 3mm thick and with a base plate of 200 mm x200 mm x 12 mm complete with 1 mtr hot dip galvanized single Arm bracket for fixing the street light and suitable foundation bolts etc. as required at the site of work. |
| 63 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 64 | Above 6.5 metre and upto 8.0 metre |
| 65 | Supplying and fixing of Hot pressed moulded SMC Junction box of size 230mm x 170mm x 105mm with 6A SP MCB, 2/4 way strip connector etc. as required at the site of work. |
| 66 | Earthing with 60mm outer dia ,2 mtr length GI earthing electrode, completely filled with conductive crystalline compound ,fitted with minimum of 40x6x2000mm GI strip including 50 kgs of eco friendly maintenance free earthing compound to enhance soil conductivity and providing masonry enclosure with cover plate having locking arrangement etc at the site of work as required. |
| 67 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 68 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 69 | Supplying and fixing of 5 KVAR Box type Heavy Duty Capacitor on existing surface/Panel including giving connection etc at site of work as required. |
| 70 | Providing and fixing following capacity Switch disconector fuse unit(with Bolted Type Fuse) in Sheet Steel enclosure with 4 Fuses,on existing panel board/wall surface including drilling holes , making connections, etc. as required. |
| 71 | 200 A, 4 pole,50 HZ,415 V |
| 72 | Supply of 16 meter HighMast shaftin two section,with base dia.360 mm and top dia 150 mm with plate thickness bottom 3 mm and top 3 mm,PCD 445 mm with the base plate of 520 mm , hot dip galvanised and suitable for wind velocity as 39-44 m / sec.as per IS:875(Part-III) with raising and lowering system comprising head frame,2 steel wire rope 6 mm dia.(AISI 304, 7/19 construction) trailing cable,( Copper 5 CORE 2.5 sq mm EPR Insulated PCP Sheathed ) double drum SWLof winch (integral Motor .75 HP-1 HP 6 Pole single speed, ) galvanised lantern carriage arrangement suitable for 8 luminaries symmetrically and its control gear boxes and lighting. The high mast shall have an integral power tool install inside the base compartment for its operation. Material Construction ASTM A572 Gr 50 / S 355 grade as per BS - EN10 025. |
| 73 | Supply and fixing of foundation bolt manufactured from special steel along with nuts, washers, anchor plate and common templates. Type /diameter/ length of foundation bolts - TS 600/24mm dia/ 850 mm long. |
| 74 | Supply installation, testing and commissioning of outdoor stand mounted feeder pillar with 32 Amp. TPN MCB incomer, single dial timer, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 nos. 9 Amp. contactors and raise lower push button, incoming 35 Sq.mm and outgoing 16 & 2.50 Sq.mm terminals etc. as reqd. Panel should be erected in min. 14 gauge CRCA sheet Box with supporting angels, self-lock, gasket and slanting top erected in CC foundation in an approved manner. |
| 75 | Supply of Singledome aviation obstruction lights with LED lamps. |
| 76 | Supply of 300 watt LED Flood light luminaries of Area lighting with energy saving Main Housing, Powder coatedpressure dia cast aluminium housing, Front Clear toughened glass, Suitable secondary lens for better light distribution Gear : Electronic constant current driver of min. 85 % effeciency Internal wiring : Teflon insulated Cu Conductor. LUMOS - 300, OperatingVoltage : 140 V - 270 V, Rated Voltage & Frequency : 240 V, 50 Hz, AC with IP 66 protection as reqd. |
| 77 | Construction of suitable shallow foundation with 1:2:4 concrete for the 16 Mtr. high mast considering the safe soil bearing capacity at size as 10 T / sq. meter at 2 meter depth with all materials and labours. |
| 78 | Erection of 16 Mtr. high mast with the help of suitable tools and tackles, wiring of luminaries with all wiring material and labour as reqd. |
| 79 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillar box suitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in chargeSize:1000mm(W)X1300mm(H)X350mm (D)Incoming4 pole MCCB, 160A, 36KA- 1 Nooutgoing4 pole MCCB, 63A, 36KA- 5 No 32A, 4 Pole MCB,10KA - 4 Nos32A, 2 Pole MCB,10KA - 2 NosMetering Panneling Digital Voltmeter - 01 Nos Digital Ammeter - 01 Nos RYB phase indication lamps-1 set 6A SP MCB for control Ckts-04 Nos200/5A Current Transformers- 03 Nos |
| 80 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillar box suitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in chargeSize:1000mm(W)X1300mm(H)X350mm (D)Incoming4 pole MCCB, 200A, 36KA- 1 Nooutgoing4 pole MCCB, 160A, 36KA- 1 No 4 pole MCCB, 63A, 36KA- 5 No 32A, 4 Pole MCB,10KA - 1 Nos32A, 2 Pole MCB,10KA - 1 NosMetering Panneling Digital Voltmeter - 01 Nos Digital Ammeter - 01 Nos RYB phase indication lamps-1 set 6A SP MCB for control Ckts-04 Nos200/5A Current Transformers- 03 Nos |
| 81 | Design, Fabrication, Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillar box suitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral(min. of 400 A), Suitable M.S Angle Base Frame, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. Size:1200mm(W)X2000mm(H)X400mm (D)Incoming4 pole MCCB, 250A, 36KA- 1 Nooutgoing4 pole MCCB, 200A, 36KA- 1 No32A, 4 Pole MCB,10KA - 4 Nos32A, 2 Pole MCB,10KA - 2 NosMetering Panneling Digital Voltmeter - 01 Nos Digital Ammeter - 01 Nos RYB phase indication lamps-1 set 6A SP MCB for control Ckts-04 Nos200/5A Current Transformers- 03 Nos |
| 82 | Providing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 83 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 84 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 85 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 86 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 87 | One or more coats on old work |
| 88 | Dismantling of existing conduit along with aluminium wire, main board, sub-main boards, switch boards and shifting to depot stores etc., as required. |
| 89 | CREDIT ITEMS |
| 90 | Dismantled MS conduit pipe of different sizes, DB’s, GI wire and clamps etc. |
| 91 | Dismantled Aluminium insulated wire |
| 92 | Dismantled 40W Box type tube light fitting |