Tender For Construction Of Pajjee St Colony Community Hall-Madhur Gp, Kassargod
Tender Value
21.60 Lakhs
Estimated cost
Bid Submission
15 Mar 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
madhur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Pajjee St Colony Community Hall-Madhur Gp, Kassargod
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundationtrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides andramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplusexcavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared |
| 4 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cementmortar 1:6 for foundation and basement including all cost of materials, labour charges etc. |
| 5 | 4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 6 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 7 | 50.2.25.1Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layersnot exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 8 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 9 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size |
| 10 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | 13.85.3Applying priming coats with primer of approved brand and manufacture, having low VOC ( VolatileOrganic Compound) content.With water thinnable cement primer on walls surface having VOC contentless than 50 grams / litre) |
| 12 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as permanufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and includingone coat of special primer applied @ 0.75 ltr /10 sqm |
| 13 | PREFAB |
| 14 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the jointswith white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 15 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 16 | 18.65Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mmwith concealed fittings arrangements, weighing not less than 106 gms. |
| 17 | 17.7.4Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mmC.P.brasspillar taps |
| 18 | 17.28.1.1Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semirigid pipe32 mm dia |
| 19 | 50.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall |
| 20 | 50.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 21 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc.complete as per the direction of site engineer-in-charge. |
| 22 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials andlabour charges etc complete as per the direction of site Engineer-in-charge. |
| 23 | 50.10.1Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 24 | 12.4.2Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or Lhooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinccoating not less than 275 gm/m2 |
| 25 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two ormore coats on new work |
| 26 | 9.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows bywelding |
| 27 | 9.7.7.2Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters fordoors, windows and clerestory windows (Area of opening for panel inserts excluding portion insidegrooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick:5.5mm thick glass pane |
| 28 | od351832/2022_2023Providing and fixing precoated Galvanised PUF sandwich panel roof sheets (size, shape, and pitch of corrugation as approved by Engineer -in- Charge) 30 mm thick panels with U- Factor (0.24to0.28) and R Value (3.95-3.41) satisfying the specification of ECBC Code( Energy ConservationBuilding Code) prescribed by Government of India. The total coated thickness with zinc coating120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of thesheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25microns minimum to avoid scratches while transportation and should be supplied in single lengthupto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the directions of E-in-C ( Rate will be paid per square metre on superfacial area ) inclusive of all charges |
| 29 | od351833/2022_2023Providing and fixing precoated Galvanised PUF sandwich panel roof sheets (size, shape, and pitchof corrugation as approved by Engineer -in- Charge) 50 mm thick panels with U- Factor (0.24 to0.28)and R Value (3.95-3.41) satisfying the specification of ECBC Code( Energy ConservationBuilding Code) prescribed by Government of India. The total coated thickness with zinc coating120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of thesheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25microns minimum to avoid scratches while transportation and should be supplied in single lengthupto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /selftapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required as per the directions of E-in-C ( Rate will be paid persquare metre on superfacial area ) inclusive of all charges |
| 30 | 51.19.ST3Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing atthe level below ground level as specified as per the direction of engineer in charge (Provision forCC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)3. 25 to below 35 flush capacity |
| 31 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 32 | od354342/2022_2023providing and fixing good quality PVC door including frame and shutter of approved make preferablysyntax of any other approved brand with all complete works directed by Engineer-in-charge. |
| 33 | electrification |
| 34 | 1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copperconductor single core cable etc as required.Group A |
| 35 | 1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copperconductor single core cable etc as required.Group B |
| 36 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 37 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5sq.mm + 1x1.5 sq.mm earth wire |
| 38 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 39 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.5/6 amps switch |
| 40 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch |
| 41 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 42 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 43 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 44 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm) |
| 45 | 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess |
| 46 | 1.27.6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.12 Module (200mmX150mm) |
| 47 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess,including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch,connection etc. as required. (For light plugs to be used in non residentialbuildings). |
| 48 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. |
| 49 | 1.34Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 50 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduitas required1 run of Cable |
| 51 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modularswitches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 52 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plateswitch box including connections but excluding modular plate etc. as required. |
| 53 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door |
| 54 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 55 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 56 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required. |
| 57 | 90.4.5.2Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades working on 230V/240V single phase A/C |
| 58 | od354374/2022_2023Supply of 250mm sweep Light Duty Exhaust fan in a plastic body with self- opening lowers workingon 230V single phase A/C. |
| 59 | od354021/2022_2023Supply and installation of 20W LED tubelight with all accesssories as required.(Make:Crompton/Philips/Wipro) |
| 60 | od354022/2022_2023Supply and installation of 9W LED bulb.(Make:Philips/Crompton/equivalent)Standard make and ISIMarked |
| 61 | od354312/2022_2023Charges for KSEB connection including provision for meter board and paneling including all laison works |
AI Tender Summary
Tender Timeline
Mar 08, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMar 15, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 16, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender