Water Resources Department-WRD has published Tender For Installation Commissioning And Maintenance Of 47 Nos 02 Hp Solar Pump In Birbhum Burdwan Hooghly District Under Wbadmip. Submission Date for this Tender is 13-04-2023. Irrigation System Tenders in birbhum West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Lot No: A Installation, Commissioning and Maintenance of 22 (Twenty Two) nos 02 HP open well Solar photovoltaic Submersible irrigation Pump over existing Pump Dug Well Scheme on various location ofMurarai Block in Birbhum District under WBADMIP |
2 | Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286and IEC 61853(1), 61730(1&2), 61710 certified Solar Module ofMonocrystalline PERC cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should havewarrantyfor output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied.a) For 2 HP Off-grid Solar Water Pumping System with Monocrystallinel PERCSPV modules (Total Modules area should not be more than 12 Sqm.) |
3 | Module Mounting Structure ( For 2HP Solar Water Pumping System): Supply , transportation & installation of G.I fixed structure made of MS hollow sections, pipes,plates, anglesetc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Moduleas perdrawing and specification of MNRE .The steel structure is to be protected withminimum 80 micron galvanisation(hot dip) and provided the fixed structure making most favorable angle in winter season. The weight of the Module MountingStructure shouldbe approx. 235Kgs, |
4 | Power conditioning unit with IP54 enclosure : Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifyingIEC 61683-Efficiency measurementand IEC 60068-2-Environment Standard , safety standardsuitable for 3 PhaseA.C. motor,IGBTbased high voltage switching inverter with MPPT technology, to take care of the variation of Sun light andwill be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum7 to 8 hours a day run should be possibleduring normalsunshine.condition. Inverter should have option to auto start forany short trip off due to low light/ cloudy situation except for dry run.Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system shouldstore the dataat a set interval, be capable to transfer it to external storage deviceand support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission.. a) For 2 HP capacity Pump-motor set |
5 | Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid insideHDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 20m(for 3/5 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etca) For 2 HP per structure |
6 | Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
7 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages |
8 | Lightning protection (Pole mounted): Lightning protection with1.5" G.I pipe of 3 m + 0.75 mts height with base flange inproper RCCfoundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc.Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure) |
9 | Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-Open well submersible pump setforPDW with discharge of5.0 -6.0 Lps at 16 mts. total head with , required quantity of flexible delivery pipe( 20m), clamps , cable (20m) and all other accessories to complete connection of suction and delivery side . |
10 | Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the fOllowing depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controllerlstarter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (b) 30 cub ic metre per hour capacity electro motor pumping set. (i) Length of pump assembly not exceeding 18 metre length. |
11 | Testing and commissioning of scheme after completion of all work |
12 | Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operationwithout lapse of time) For 2 HP submersible & surface pump Note:1 Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year& Comprehensive maintenance chargeswillbe released@ i) Rs 1.00 for 2 HP, ii) Rs.1.00 for 3 HP, iii) Rs.0.75 for 5 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year.In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will beforfeited |
13 | INSURANCE for a period of 5 years: Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. |
14 | Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions: a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b. Live status must indicate whether controller is ON/ OFF ? The parameter i.e. the water output, water flow rate, in fault condition, array input voltage/ current, power and motor frequency should at logged at an interval of 10 minutes c. Controller must have a back up to store the data locally ( at least for 1 year) supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. (Refer Technical Spec.) |
15 | Supply of lay flat hose of 75 mm nominal size polyester reinforced lay flat hose (the hose should have wall thickness 1.3 mm working pressure 3.0 kg/sqm & brusting pressure 9 kg /sq m. The lay flat hose should have a standard length od 100 m roll. |
16 | Earthwork in excavation of foundationtrenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete...................................................................................................................Depth of excavation not exceeding 1500 mm.(considering 50 mm clearence) |
17 | Earthwork in excavation of foundationtrenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete............................................................................................................................................................................. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
18 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. |
19 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints withlocal sand. |
20 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). |
21 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips(20mm& 10 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relavent IS codes. i) Pakur variety. |
22 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Sail/ TATA/RINL |
23 | M.S. Works in bolts and nuts of different sizes fitted and fixed in position including drilling holes and welding including cost of labour and materials. |
24 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints including throating, nosing and drip course, scaffolding/ staging where necessary ( ground floor) [ excluding cost of chipping over concrete surface]ratio 1:4, 20 mm thick plastering |
25 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. |
26 | Lot No:B Installation, Commissioning and Maintenance of 8 (Eight)no"s 2 HP Solar Pumping irrigation system over existing surface minor irrigation schemes at Kanksa Block in the district of Paschim Bardhaman under DPMU Burdwan WBADMIP |
27 | Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286and IEC 61853(1), 61730(1&2), 61710 certified Solar Module ofMonocrystalline PERC cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should havewarrantyfor output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied.a) For 2 HP Off-grid Solar Water Pumping System with Monocrystallinel PERCSPV modules (Total Modules area should not be more than 12 Sqm.) |
28 | Module Mounting Structure ( For 2HP Solar Water Pumping System): Supply , transportation & installation of G.I fixed structure made of MS hollow sections, pipes,plates, anglesetc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Moduleas perdrawing and specification of MNRE .The steel structure is to be protected withminimum 80 micron galvanisation(hot dip) and provided the fixed structure making most favorable angle in winter season. The weight of the Module MountingStructure shouldbe approx. 235Kgs, |
29 | Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concretefoundation forSPV Modulestructure as per approved drawing. |
30 | Power conditioning unit with IP54 enclosure: Supply, transport, installation and commissioning of IP 54 protected enclosure Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard, safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure.Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc.System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Output AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc.The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol.It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission. For 2 HP capacity Pump-motor set. |
31 | Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid insideHDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 20m(for 3/5 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etca) For 2 HP per structure |
32 | Earthing: (IS : 3034) Earthing with 40 mm dia GI pipe 3.64 mm thick 1 x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
33 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages |
34 | Lightning protection (Pole mounted): Lightning protection with 3"" X 1.5" G.I pipe of 3 m + 0.75 mts height with base flange inproper RCCfoundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc.Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure) |
35 | Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-a) 2 HP ISI marked as per IS 9079 surface mounted Monoblock Pump-motor setwith2.60 - 2.78 Lps discharge at 26 mts. total head suitable for 2.0 Ha CCASprinkler / Dripoperation with foot valve, required quantity of flexible suction pipe(15m), clamps, bend, footvalves and all other accessories to complete connection of suction and delivery side . |
36 | Testing and commissioning of scheme after completion of all work |
37 | Comprehensive maintenance charges for 5 years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operationwithout lapse of time) Note:-Total comprehensive maintenance charge is to be withheld in addition to Security Deposit. Security Deposit will be released after@ Rs 1.00 per year per WP at the end of each maintenance yearof 1st Year, 2nd year, 3rd year, 4th year, 5th year.In case the “Bidder” does not provide service during thecomprehensive maintenance period, the amount so held up will be forfeited. Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year& Comprehensive maintenance chargeswillbe released@ i) Rs 1.00 for 2 HP, ii) Rs.1.00 for 3 HP, iii) Rs.0.75 for 5 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year.In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will beforfeited |
38 | INSURANCE for a period of 5 years: Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. |
39 | Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic function : a) Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b) Live status must be indicate whether controller is ON / OFF , the parameter i,e the water output, water flow rate, in fault condition, array input voltage / current , power and motor frequency should at logede at an interval of 10 minutes.c)Controller must have a back up to store the data locally (at least for 1 year) supply & Installation of GSM / GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameter to central server from the solar pumping system with time stamp at user defined interval and report generation at the buyer end |
40 | Supply of lay flat hose of 75 mm nominal size polyester reinforced lay flat hose (the hose should have wall thickness 1.3 mm working pressure 3.0 kg/sqm & brusting pressure 9 kg /sq m. The lay flat hose should have a standard length od 100 m roll. |
41 | Lot No:C Installation, Commissioning and Maintenance of 17 (Seventeen) nos. of 2 HP Solar Pumping System adjacent to existing WDS, LDTW, MDTW and RLI schemes under DPMU Hooghly, WBADMIP |
42 | Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286and IEC 61853(1), 61730(1&2), 61710 certified Solar Module ofMonocrystalline PERC cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should havewarrantyfor output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied.a) For 2 HP Off-grid Solar Water Pumping System with Monocrystallinel PERCSPV modules (Total Modules area should not be more than 12 Sqm.) |
43 | Module Mounting Structure ( For 2HP Solar Water Pumping System): Supply , transportation & installation of G.I fixed structure made of MS hollow sections, pipes,plates, anglesetc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Moduleas perdrawing and specification of MNRE .The steel structure is to be protected withminimum 80 micron galvanisation(hot dip) and provided the fixed structure making most favorable angle in winter season. The weight of the Module MountingStructure shouldbe approx. 235Kgs, |
44 | Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concretefoundation forSPV Modulestructure as per approved drawing. |
45 | Power conditioning unit with IP54 enclosure: Supply, transport, installation and commissioning of IP 54 protected enclosure Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard, safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure.Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc.System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Output AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc.The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol.It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission. For 2 HP capacity Pump-motor set. |
46 | Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid insideHDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 20m(for 3/5 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etca) For 2 HP per structure |
47 | Earthing: (IS : 3034) Earthing with 40 mm dia GI pipe 3.64 mm thick 1 x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
48 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages |
49 | Lightning protection (Pole mounted): Lightning protection with 3"" X 1.5" G.I pipe of 3 m + 0.75 mts height with base flange inproper RCCfoundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc.Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure) |
50 | Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-a) 2 HP ISI marked as per IS 9079 surface mounted Monoblock Pump-motor setwith2.60 - 2.78 Lps discharge at 26 mts. total head suitable for 2.0 Ha CCASprinkler / Dripoperation with foot valve, required quantity of flexible suction pipe(15m), clamps, bend, footvalves and all other accessories to complete connection of suction and delivery side . |
51 | Testing and commissioning of scheme after completion of all work |
52 | Comprehensive maintenance charges for 5 years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operationwithout lapse of time) Note:-Total comprehensive maintenance charge is to be withheld in addition to Security Deposit. Security Deposit will be released after@ Rs 1.00 per year per WP at the end of each maintenance yearof 1st Year, 2nd year, 3rd year, 4th year, 5th year.In case the “Bidder” does not provide service during thecomprehensive maintenance period, the amount so held up will be forfeited. Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year& Comprehensive maintenance chargeswillbe released@ i) Rs 1.00 for 2 HP, ii) Rs.1.00 for 3 HP, iii) Rs.0.75 for 5 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year.In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will beforfeited |
53 | INSURANCE for a period of 5 years: Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. Note : Ist Year"s Insurance charge is to be paid on production of Original Receipt of Premium Payment. Remaining 4 Years Insurance Payment is to be withheld which will be released during 2nd , 3rd, 4th & 5th year on production of original Receipt of premium payment. |
54 | Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic function : a) Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b) Live status must be indicate whether controller is ON / OFF , the parameter i,e the water output, water flow rate, in fault condition, array input voltage / current , power and motor frequency should at logede at an interval of 10 minutes.c)Controller must have a back up to store the data locally (at least for 1 year) supply & Installation of GSM / GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameter to central server from the solar pumping system with time stamp at user defined interval and report generation at the buyer end |
55 | Supply of lay flat hose of 75 mm nominal size polyester reinforced lay flat hose (the hose should have wall thickness 1.3 mm working pressure 3.0 kg/sqm & brusting pressure 9 kg /sq m. The lay flat hose should have a standard length od 100 m roll. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail