Housing Urban and Rular Development Government Departments Closing in 0 days TDR #36661529

Construction Of Daily Market Cum Parking Place At Kharsang

Issued by Government Departments · kharsang, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Mar 2023
0 days left
EMD
4.75 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kharsang → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Daily Market Cum Parking Place At Kharsang

BOQ

Name of Work: Construction of Daily Market cum parking place at Kharsang
Sl. No. Item Description
1Site Development
2Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)Girth from 300 mm to 600 mm
3Clearing Grass and Removal of Rubbish
4Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.)
5Excavation in ordinary rock by manual means (Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres )
6Market Shed
7Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m.
8Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
9Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :
10Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
11Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm
12Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement
13Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
14Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
15Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
16Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
17Extra for half brick masonry in superstructure above plinth level and up to floor two level.
18Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.
19Centring and shuttering including strutting proping etc. and removal of form work for:
20a) Foundations and plinth.
21b) Walls including attached buttresses, pilasters etc.
22c) Columns, pillars and piers.
23d) Beam
24e) RCC Slab
25Reinforcement of RCC work including bending, binding and placing in position complete.
2625 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.
27Chequrred terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:(a) Light shades using white cement
2812 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
29White washing with lime on new work (two or more coats) to give an even shade.
30Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade
31Hiramachi colour wash on new work (two or more coats) to give an even shade.
32Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
33Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
34Laying of G.I Pipes,i/c trenchinng,fitting,fixing etc complete.15mm dia
3560 mm dia
36Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
37Add carrying charges as per TC
38CC Pavement
39Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.
40Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) [ for grading- I Material]
41Dry Lean Cement Concrete Sub- baseConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
42Cement Concrete Pavement:-Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
43Cable Duct Across the Road:-Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. Triple Row for three utility services
44Centring and shuttering including strutting proping etc. and removal of form work for:a) Foundations and Plinth.
45Carriage of Materials
46Toilet
47Earth work in excavation in soils containing 50% or more of shingle or small size boulders upto 30 cm size including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions lead upto 50 m and lift upto1.50 m.
48Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
49Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level.
50Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :c) Independent piers, columns and pillars up to floor two level.
51Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
52Centring and shuttering including strutting proping etc. and removal of form work for:b) Walls including attached buttresses, pilasters etc.
53c) Columns, pillars and piers.
54Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
55Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
56Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38mm thick best available local wood class - B I
57Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
5825 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.
59White washing with lime on new work (two or more coats) to give an even shade.
60Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
61Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
62Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required
63Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) One urinal basin with 5 Litres CI automatic flushing cistern
64Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality.
65Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
66Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws.
67Providing and fixing of MS Grill of required pattern in woodern frames of windows etc with MS flat, or round bars etc complete.a) Plain grill.
68Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth
69Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete
70Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
71Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design.
72Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia
73Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floorsa) 100 mm inlet and 100 mm outlet
74Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). 15mm nominal bore
75Providing and fixing brass bib cock of approved quality. 15mm nominal bore
76Septic Tank
77Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
78Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
79Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
80Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floortwo level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :
81Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
82Centring and shuttering including strutting, propping etc and removal of form work for :a)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
83b)Suspended floors,
84Reinforcement of RCC work including bending, binding and placing in position complete.a) Cold twisted bars.
8515 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.
86Neat cement punning.
87Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia
88b) 75 mm dia
89Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
90Add Carrige charge
91Dustbin
92Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m
93Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
94Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :
95Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
96Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
97Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
98b) Column, pillars, posts and struts etc.
99c) Wall
10025 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.
101Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws- Ornamental grill.
10212 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
103Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
104UG Tank
105Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
106Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
107Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
108Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floortwo level including finishing and plastering the exposed surfaces with cement mortar 1a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
109Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth an
110Centring and shuttering including strutting, propping etc and removal of form work for :a)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
111b)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
112Reinforcement of RCC work including bending, binding and placing in position complete.a) Cold twisted bars.
11315 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.
114Neat cement punning.
115Add Carrige Charge
116External Electrification
117C/o 33KV HT Line on 10mtr long steel tubular pole
118STEEL TUBULAR POLES as per ISS.10 M long of 410 SP-44
119CONDUCTORS as per ISSRABBIT Conductors ACSR. (6/1/35 sqmm)
120STRINGING OF LINE CONDUCTOR & ACCESSORIESStringing of ACSR conductor as per approved sagging including installation of insulators, hardware fitting, conductors accessories, jumpering arrangement, stringing of guard wire. This shall also includes errection of PG clamp and connectors, jointing sleeves, danger plate & anticlimbing device etc. as required complete in all repsect as per TS.ACSR / AAC Conductor 6/1/3.35 Sqmm RABBIT or equivelant conductor.( HT line) (3 wire line)
121INSULATORS as per ISSDISC (Porcelain)Disc insulator 70 KN.
122HARDWARE FITTING (as per ISS)70 KN Disk Insulator (33 KV tension type hardware fitting) as required.
123PIN (Porcelain)Pin Insulator 33 KV with pin.
124CROSS ARMS (MILD STEEL)33 KV, 3 Wire, 3.05 m long cross arms made of Channel of size 125 X 50 X6 mm complete etc. as required.
12534 KV, \"\" Y\"\" - Typecross arms made of Angle of size 50 X 50 X 6 mm in radial structure of 3 arms of 0.9 m long 120* apart complete etc. as required.
126GI STAY SETGalvanized stay set complete with galvanised MS anchor plate of size 300 X 300 X 5 mm, anchor rod of length 1800 mm & 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as requried (of all size)
127CROSS BRACING (MILD STEEL)Angle bracing set 3.6 m long of size 65 X 65 X 6 mm complete with accessories nut / bolts etc. as reqiured.
128SAFETY ALERT SYSTEMManufacturing, fabrication and supply of danger plate made of mind steel sheet of atleast 1.6 mm thick and vitreous enameled white, with letters, figures and the conventional skull and cross-bones in single red colour on the front side for -Danger plate of size 250 mm x 200 mm of thickness 3 mm.
129Anti climbing devices with G.I. thorwire / Barbed wire.
130GUARD BRACKET (MILD STEEL)33 KV, 3.5 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm complete etc. as require.
131Supply & Stringing of 8 SWG G.I. Earth wire
132EARTHING SYSTEMEarthing with 40 mmdia pipe 4.5 mtr long with GI wire for pole earthing including salt charcoal etc. as reqd.
133PAINTINGS & FINISHING WORKSSupply & Painting with 2 coats of red oxide paint & 2 coats of paints on pole / equipment / metal surface on full rate basis.
134Cutting down of smaller trees of girth 300 mm and below including all types of vegetation, grass bushes, shrubs, saplings and remains of them for ease access for laying and stringing of conductors as well as to make foot path at tower locations or any construction site as may be required.
13563 KVA, 33 / 0.433 KV Distribution Sub-Station
136Three Phase Distribution Transformers33/0.433 KV Transformer as per ISS3-?, 100KVA, 33/0.433 KV Outdoor Type Transformer
137Designing, Manufacturing & Supplying of 33 KV, 50 HZ Air Break Switch conforming to IS : 9920 (Pt-I to V) with rated voltage 12 KV & rated normal current shall be 400 Amps. Provided with bimetallic connector on the incomming side to accommodate ACSR of sizes 20, 30, 50 sqmm on the outgoing side
138Designing, Manufacturing & Supplying of outdoor, drop out expulsion type of 33 KV drop out fuse suitable for insullation in 50 Hz, 33 KV distribution system conforming to IS 9385 (Pt-I to III) with rated voltage shall be 12 KV & rated current shall be 100 AMPs & also shall be provided with a suitable arrangement these on 100x50x6 mm channel cross arm.
139Insulators as per ISSDisc Insulator 70 KN
140Hardware Fittings (as per ISS)70 KN Disc Insulator (33 KV tension type hardware fittings) etc. as required
141Designing, Manufacturing & Supplying of Lightning Arrestor of different ratings as per Specification33KV lines and systems
142Steel Tubular poles as per ISS10 Mtr long of 410 SP-44
143GI Stay SetGalvanized stay set complete with galvanised MS anchor plate of size 300x300x5 mm, anchor rod of length 1800 mm & dia 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes).
144MS channel of size 100x50x4.7 mm for Air Break switch top bracket transformer mounting and Drop out fuse (8x2=16m) i/c nuts and bolts
145LT switch Gear SystemsDesigning, Manufacturing & Supply of weather proof pole mounted, LT panel Board with adequate ratings of MCCBs/RCBs/MCBs spate duly provided for mounting DT, Energy meter & service connection distribution board within the same panel
146Energy Meters without Modems3 Phase 4 wire LT whole current class 0.5 accuracy energy meter without CT TS/GTP 10-60 Amps.
147Manufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6 mm thik and vitreous enameled white, with letters, figures and conventional skull and cross bones in signal red colour on the front side for :-Anti climbing devices with GI thornwire / Birbed wire
148Designing, Manufacturing & supplying of 1.1 KV grade steel armoured Power Cable (Aluminium Conductors) of following capacities120 sqmm x 3.5 core
149Insulators as per ISSPin Insulator33 KV with Pin
150Painting & finishing worksSupply & painting with 2 coats of red oxide paint & 2 coats of paints on poles / equipment / metal surfaces on full rate basis.
151Safety Alert SystemManufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6 mm thick and viterous enameled white, with letters, figures and the conventional skull and cross - bones in signal red colour on the front side for -Danger Plate of size 250 mm x 200 mm of thickness 3 mm
152Supply & stringing of 8 SWG GI earth wire.
153Copper plate earthing of transformer CBS & Batter charger including cost of copper plate size 600x600x6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc. as required
1543Ph, 4 Wire LT Line on 7.5mtr long steel tubular pole
155STEEL TUBULAR POLES AS PER ISS7.5 M Long 410 SP-9
156CONDUCTORS as per ISSSQUIREL Conductor ACSR,(6/1/2.11 sqmm)
157STRINGING OF LINE CONDUCTOR & ACCESSORIESStringing of ACSR conductor as per approved sagging including installation of insulators, hardware fittings, conductor accessories,jumpering arrangement,stringing of guard wire. This shall also includes errection of PG damp and connectors,jointing sleeves,danger plate & anticlimbing device etc.as required complete in all respect as per TS.ACSR / AAC Conductor 6/1/2.11 Sqmm SQIRREL or equivalent Conductor. (LT or HT line (3 wire line)
158Supplying & Stringing of 8 SWG G.I Earth wire
159Manufacturing and supplying of GI earth clamps
160INSULAORS as per ISSSHACKLE (Porcelain)Shackle insulator LT with pin.
161PIN (Porcelain)Pin insulator LT with pin
162CROSS ARMS (MILD STEEL)Lt, 4 Wire cross arm made of channel of size 75 X 40 X 6 mm complete etc. as required.
163GI STAY SETGalvanized stay set complete with galvanized MS anchor plate of size 230 X 230 X 5 mm, anchor rod of length 1800 mm & dia 18mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes)
164Designning, Manufacturing & Supplying of Lighting Arrestor of different ratings as per Specification.LT 3 Phase lines and systems.
165SAFETY ALERT SYSTEMManufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6mm thik and vitreous enameled white,with letters, figures and the conventional skull and cross bones in signal red colour on the front of side for :-Danger Plate of size 250mm X 200mm with thickness 3 mm
166Anti climbing devices with G.I thronwire / Barbed wires.
167EARTHING SYSTEMEarthing with 40mm dia G.I pipe 4.5mtr. Long with GI wire for pole earthing including salt charcoal etc. as reqd.
168PAINTING AND FINISHING WORKSSupply & Painting with 2 coats of red oxide paint & 2 coats of paints on pole / equipment / metal surface on full rate basis.
169Internal Electrification
170Wiring
171Wiring for light point with 1.5 sq.mm P.V.C. insulated Aluminum cable in surface P.V.C Conduit as required[A]Short-Point
172[B]Medium-Point
173[C]Long-Point
174Wiring for fan point with 1.5 sq.mm. P.V.C. insulated Aluminum conductor cable in surfaceP.V.C. conduit including ear thing the Regulator etc. as required[A]Medium-Point
175[B]Long-Point
176Wiring for Exhaust fan point with 1.5 sq.mm. P.V.C. insulated Aluminum conductor cable insurface P.V.C. conduit including ear thing the Regulator etc. as required.[A]Medium-Point
177Wiring for 3 pin 5 Amps. Plug point with 1.5 sqmm. P.V.C. insulated Alluminium conductor inin surface P.V.C. conduit including providing and fixing 3 pin 5 Amps. Socket out let and 5 Amps. Flash Type Switch on the switch board, earthing the third pin etc. as required [A]On Board
178Wiring for 3 pin 5 Amps. Plug point with 1.5 sqmm. P.V.C. insulated Alluminium conductor inin surface P.V.C. conduit including providing and fixing 3 pin 5 Amps. Socket out let and 5 Amps. Flush Type Switch on the switch board, earthing the third pin etc. as required[A]Long-Point
179Wiring for 3 pin 15 Amps. Plug point with 4.0 sqmm. P.V.C. insulated Alluminium conductor in surface P.V.C. conduit including providing and fixing 3 pin 15 Amps. Socket out let and 15 Amps Flash type Switch, earthing the third pin etc. as required[A]Extra Long-Point-II
180[B]Extra Long-Point-III
181Wiring for circuit wiring with 2x1.5 sqmm. P.V.C. insulated Alluminium conductor single core cable in surface P.V.C. conduit etc. as required
182Wiring for circuit wiring with 2x2.5 sqmm. P.V.C. insulated Alluminium conductor single core cable in surface P.V.C. conduit etc. as required---
183Fittings & Accessories
1841x40 watt 4\"box type tube light fitting with arcylic cover complete as reqd.(Bajaj/philips make)[A]Single 1200mm 40 watt-
185Supplying of the following sizes of electric ceiling fan capacitor type complete with 30 cm. down rod, canopies, hanging shackle,blades & speed regulator suitable for use on 230/240 volts, 50 Hz single phase hanging shackle, blades & speed regulator suitable for A.C. supply confirming to I.S.S : 374/1979 : CLASS-I[A]1400 mm. Sweep-
186Supplying and fixing Socket type Moduler fan reglator complete with all accessories etc. as required
187Supplying of C.F.L /LED Lamps 11 watt to 20 wattfor use on 230/250 volts A.C. 50 Hz. Supply in different shape of following sizes[A] 8 to 20 watt-
188Supplying of following fluorescent tubular lamps[A]1200mm 40 watt-
189Supplying and Fixing of celling rose on the existing P.V.C Block/Board including connection etc.as required---
190Supplying and Fixing of Brass/P.V.C Batten/Angle holder including connection etc. as required---
191Supplying of 40mm dia. G.I. pipe for suspension of ceiling fan 1X3mtr. Only first floor etc as required---
192Supplying of half round clamps suitable for fixing of 40mm. Dia G.I pipe ( 1 set= 2 Nos. for each fan ) with necessary nails/nuts & bolts etc. as required---
193Supplying of 50W LED flood light fittings
194Supplying of fan suspension clamp of suitable size and shape as per site requirement with nuts & bolts ( 1 Nos. for each fan ) etc as required---
195Main & Sub-Main Boards
196Supplying of Miniature circuit breaker suitable for operation on 240/440 Volts, 50 Hz. ,A.C. supply confirming to I.S.S: 8828/1978 etc as required[A]Single Pole--6 Amps.-
197[B]Single Pole--10 Amps.-
198Supplying of Miniature circuit breaker suitable for operation on 240/440 Volts, 50 Hz. ,A.C. supply confirming to I.S.S: 8828/1978 etc as required[A]SP & N--16 Amps.-
199[B]SP & N--32 Amps.-
200[C]TP & N--32 Amps.-
201Supplying of single pole & neutral distribution boards suitable for incorporating single pole/ single pole &neutral M.C.B. complete with all accessories etc. as required[A] 4--Way-
202[B] 6--Way-
203[C] 8--Way-
204[D]12-Way- with TP&N Provision
205Supplying of Triple pole & neutral Bus Bar Chamber with Copper Strips Suitable for TP & N M.C.B 3 phase Bus-Bar double door with locking and earthing arrangement of I.S.I make of standard brandHavelles/MDS or equivelent properly painted with out M.C.B complete with all accessoriesetc. as required[A] 4-Pole-200 Amp.
206Providing/Fixing/Commissioning of main Pannel Board with a 4 Pole Bus Bar of 250 Amp. Complete with Volt/Ampere Meters & Selector Switch, 3 Phase L.E.D Indicator with the provision of 4 Pole Change Over and 2 Nos M.C.C.B of 250 Amp. And 1 No. 100 Amp. For D.G Set well painted all Sheet Matel work and other accessories as required
207Sub-Main & Service Connection
208Wiring for sub-main with 4sqmm./6sqmm./10sqmm./16sqmm. P.V.C Insulated Copper conductor Single Core cableinsurface P.V.C. Casing Caping etc. as required[A] 4-Sqmm.-
209[B] 6-Sqmm.-
210Providing & Laying of 1 no. P.v.C. insulated and P.V.C sheathed power cable of 1.1 kv. Grade of size not exceeding 3 1/2 X 50sq mm. in the existing R.C.C/Hume/Stone Ware/G.I pipe as required
211Laying of 1 no. P.v.C. insulated and P.V.C sheathed power cable of 1.1 kv. Grade of size not exceeding 3 1/2 X 120 sq mm. direct on ground including excavation sand cushioning protective covering andreffiling the trench etc as required
212Providing and fixing 40 mm. dia G.I. pipe with existing L.T line pole/wall etc. as required
2133 Phase 4 wire, class 1.0 accuracy suitable for connection to LT 3 phase 2x230 V syst4ems whole current static energy meter of current range 10-60A, with temper proof meter box
214Earthing
215Copper earth plate of size 600mmx600mmx3mm having not less than 10.54 Kg/plate.
216Copper strip of size 25x4mm having 1.916 Kg/mtr for earthing.
217EarthingwithG.I. Ear thingpipe 4.5 Mtr. longandof 40 mm. dia with massonary enclosure at top etc. as required---
218Extra for using salt and charcoal for pipe earth electrode etc as required---
219ProvidingandLayingearthconnectionfromearth electrode with 4.06 mm.( 8 S.W.G. ) dia G.I. wire in 15 mm. dia G.I. pipe from earth electrode etc. as required---
220Providing and Fixing .4sqmm alluminium earthing wire

AI Tender Summary

OUR REF NO 36661529
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 20-03-2023
Authority
Authority Name Urban Development And Housing Department
Work Description Construction Of Daily Market Cum Parking Place At Kharsang
Basic Detail
Tender No EE/UD/JRP/BE-01/2022-23/07
Bidding Type Tender
Location
City kharsang
State Arunachal Pradesh
Key Dates
Publish Date 07 Mar 2023
Submission Date 20 Mar 2023
Open Date 20 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 4.75 Lakhs
Exemption Not Available
Document List
7fee2ea8-082e-4a99-9f9b-fe93207ae33d.html
BOQ_1274.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 07, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 20, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 20, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

7fee2ea8-082e-4a99-9f9b-fe93207ae33d.html

xls

BOQ_1274.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders