Rural Development Government Departments Closing in 0 days TDR #36658906

Tender For The Proposed Repair, Renovation And Upgradation Of Existing Anusuchit Janjati Boys Hostel Building With Toilet At Tapkara, Torpa Block, District Khunti.

Issued by Government Departments · torpa, Jharkhand
Tender Value
25.44 Lakhs
Estimated cost
Bid Submission
14 Mar 2023
0 days left
EMD
51000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
torpa → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

The Proposed Repair, Renovation And Upgradation Of Existing Anusuchit Janjati Boys Hostel Building With Toilet At Tapkara, Torpa Block, District Khunti.

BOQ

Name of Work: The Proposed Repair, Renovation and Upgradation of Existing Anusuchit Janjati Boy\"s Hostel Building with Toilet at Tapkara, Torpa block, district Khunti.
Sl. No. Item Description
1Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
2Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
4Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level - 1:3:6 (1 cement : 3 coarse sand (zone - III): 6 graded stone aggregate 20mm nominal zie)
6Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
7Top, bottom and lock rails shall be provided eigher side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer\"s specificatio n& drawing (for W.C. and bathroom door shutter).
8Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinfoorced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Enginner-in-Charge.
9Providing & fixing pressed steel door frames manufacturedfromcommercialmild steelsheet of 1.25mm thickness including hinges ,jamb,lockjamb,beadand if requiredangle threshold of mild steel angle section 50 X 25mm, orangle threshold of mild steel angle section 50 X 25mm, orbase ties of1.25mm pressedmild steel welded or rigidlyfixed together by mechanical means, adjustable lugs withsplitendtailto eachjambincludingsteelbutt hinges splitendtailto eachjambincludingsteelbutt hinges 2.5mmthickwithmortarguards,lockstrike-plate and 2.5mmthickwithmortarguards,lockstrike-plate andshockabsorbersasspecifiedandapplyinga coatof approvedsteelprimerafterpre-treatment of the surface as directed by the Engineer Incharge - Profile - B- Fixing with adjustable lugs with split end tail to each jamb
10Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
11For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required inlcluding the cost of EPDM rubber/neoprene gasket required (fittings shall be paid for separately) ---Powder coated aluminium (minimum thickness of powder coating 50 micron)
12Providing and fixing glazing in aluminium door, window, ventilator, shutters and partitions etc, with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (cost of aluminium snap beading shall be paid in basic item)With float glass panes of 4mm thickness (weight not less than 10kg/sqm.)
13Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
14Providing and laying Doublecharge Vitrified floor tiles in different sizes (thickness to be specificed by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete size of tiel 600X600mm
15Providing and laying rectified glazed ceramic floor tiles 300x300mm or more (thickness to be specified by manufacturer) of 1st quality conforming to IS:15622 with approved make in all colours,shades,except white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/sqm. including pointing the joints with white cement and matching pigments, etc.complete.
16Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
17Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete as per building specification and direciton of E/l.With \"A\" grade white 15 x 15 cm tiles.
18Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
19Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
20Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
21Extra for clean the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I.
22Providing two coats of oil bound distemper of approved shade and make over old surface including washing, cealning sand papering the wall, scaffolding washing of floors and taxes all complete as per building specification of and direction of E/I.
23Providing two coats of oil bound distemper ofapproved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
24Finishing walls with premium acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm
25Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I.
26Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
27Providing two coats of synthetic enamel paint over a coat of primer of approved shade and make over new wooden surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.
28Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt, scales, smokes, greas and sand papering, including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
29d. Protection of treated surfaces with PCC ;The treated syrface shound be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt X 2 mtr. Keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (Paid separately for this items)All corners shall be chamfered with 150mm X 150mm fillet.The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - peripherial gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete nd the peripherial mouth to be sealed with mosture insensitive epoxy putty of sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/Fosroc.For purpose of measurement the entire treated surfaces will be measurede,Grooves of PCC surface should be filled with polysulphide sealant.Brand - Sika India Pvt. Ltd. /MYK Schomberg/Dr. Fixit/Foscroc warranty for five years.
30Covering of treated surface with PCC - Providing 25mm thickCement Concrete M-20 (1:1.5:3) maintaining slope in alternte 2 mt X 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with adminxture of integral water proofing and placing in position striking curing, taxes and royalty all complete as per building specificastion and direction of E/I.Panels that has been left should be casted next day.There should be 6mm gap between panels brand - Sika-Plastocrate plus, MYK proof WP 10, Fosroc - Conplast X 421ic,Dr. Fixit pidiproof LW+
31Providing and filling 6mm thick groove between 25mm PCC panelswith polysulphide sealant (Poring Grade) as per drawings and technical specifications and direction of E/C (with 18%GST) brand - Sika-Polysulphide, Fosroc-Thioflex 600, Dr. Fixit Piddiseal PS (42P) MYK seal PS or equvalent
32Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
33Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.Bend 87.5 degree - 110X110X110mm
34Shoe plain -110mm
35Providing and fixing to the inlet mouth of rain water pipe cast iron grating15 cm diameter and weighing not less thaN 440 grams.
36Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete -110mm
37Carriage of materails Bricks- Lead-7 + 1km.
38Sand- Lead10km
39Chips - Lead45km
40Metal - Lead45km.
41Cement- Lead9km.
42PLUMBING WORK Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flushpipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (A) 580 mm longwith 12.5 litre low level PVC cistern
43supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
44Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.20mmdia.
4525mmdia.
4632mmdia
4740mm dia
48Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I.… 15mm dia.
49Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
50Making holes in wall for laying PVC pipes and restoring the same all cost complete (PVC pipe 110mm dia)
51Supplying all tolls and labour and cutting chajja cornice for laying PVC pipes and making good the same as per specification and direction of E/I. (110mm dia PVC pipe)
52Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I.(all rates have been adopted from the basic rate from SOR + 30% for labour and Contractors profit) Pillar cock (long neck)
53Bib cock - long thread
5432mm dia. PVC waste pipe 750mm long with coupling
5515mm C.P. nipple with coupling
56Steel jali- 100mm dia.
57Providing Solvent cement
58Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.600 X 450mm
59Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container
60Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
61Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
62Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
63Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931,15mm dia nominal bore of approved brand C.P. fittings
64Providing and fixing PTMT extension nipple 15mm size with 12\" BSP thread 70mm length and 30mm breadth and weighing not less than 18gms of approved make
65Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittingsi.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc. 20mm nominal bore
6625mm nominal bore
6732mm nominal bore
68External work -40mm nominal bore
69Providing & fixing on wall face unplasticised -Rigid P.V.C.pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
70Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.Single Tee with door-110x110x110 ,mm
71Bend 87.5 degree-110 mm bend
72Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
73Providing and fixing Pressure adjustable shower with revolving joint
74Supplying, fititng and fixing stainless steel A ISI 304 (18/8 Kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets cutting and making good the walls wherever required- Kitchen sink without drain board - 610X510mm bwl depth 200mm
75Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I.PVC cowl - 100mm dia.
76Floor trap - 100mm dia.
77Single pushfit coupler
78Dismantling GI pipes including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 mtrs. Lead as per direction of E/I.-15mm to 40mm nominal bore
79Dismantling of flushing cistern of all types (C.I./PVC/Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 mtrs. Lead (IWC)
80ELECTRCIAL WORKPoint Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
81Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
82Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
83Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x1.5 Sqmm + 1x1.5 sqmm earth wire
842x2.5 Sqmm + 1x2.5 sq mm earth wire
852x4 Sqmm + 1x4 sq mm earth wire
86S/F TP MCB DB:-Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623)4 Ways (4+12 ways) double door
87S/F \"C\" series MCB:-Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.6/32A Single Pole
886/32A TPN MCB
89S/F Ceiling Rose: Supplying andfixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
90S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
91ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage,including connection, testing, commissioningetc as required.
92S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required.
93S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required- 20/22W. LED tube light
94Bulk head fitting with 9/10Watt CFL/LED
95Supplying, 15/16 Watt LED bulb of approved make
96SupplyingExhaustfan of 12\" (300mm) of aproved make
97Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. -1400mm (56\") ceiling fan
98S.I.T.C. of following rating LED street lighting luminarie die cast housing and toughened glass cover (IP-66 portion) in existing pole/pipe for supply voltage 100-270V. AC, 50Hz.Luminaire shall be confirm to IS:10322 part - 5/section 3 and shall be complete with all necessary accessories as required- 60W LED street light
99GST @ 18%
100Labour Cess @ 1%

AI Tender Summary

OUR REF NO 36658906
AUTHORITY Government Departments
TENDER VALUE 25.44 Lakhs
LAST DATE 14-03-2023
Authority
Authority Name Rural Development Department
Work Description The Proposed Repair, Renovation And Upgradation Of Existing Anusuchit Janjati Boys Hostel Building With Toilet At Tapkara, Torpa Block, District Khunti.
Basic Detail
Tender No RDD/SD/KHN/43/2022-23
Bidding Type Tender
Location
City torpa
State Jharkhand
Key Dates
Publish Date 07 Mar 2023
Submission Date 14 Mar 2023
Open Date 16 Mar 2023
Finance
Tender Value 25.44 Lakhs
Tender Fee 5000
EMD 51000
Exemption Not Available
Document List
34becff8-fff7-42f4-9d4d-412830eb19f8.html
BOQ_90956.xls
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 07, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 14, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

34becff8-fff7-42f4-9d4d-412830eb19f8.html

xls

BOQ_90956.xls

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail