| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 2 | A) Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). (B) Do - by fine sand |
| 3 | Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth |
| 4 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 5 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety. (PCC Work) |
| 6 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.. (i) Pakur Variety. (RCC Work) |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m. (i) Tor steel/Mild Steel. II. Other than SAIL/ TATA/RINL. |
| 8 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). |
| 9 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 10 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. c)15mm thick plaster (i) With 1:6 cement mortarWall. i) Internal Wall |
| 11 | ii) External Wall |
| 12 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 13 | White washing including cleaning and smoothening surface thoroughly. All floors : (b) Two coats (to be done on specific instruction). |
| 14 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface. Two Coats |
| 15 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor (i) Grill weighing 18 Kg./sq.mtr. |
| 16 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 17 | Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by the Agency]. (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur Pink / Udaypur green / Black Bhalsana |
| 18 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre. (iii) 80 mm dia. boring etc |
| 19 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) |
| 20 | (a) 80 mm dia P.V.C.. pipe S-40 of ASTM-D-1785 approved Brand |
| 21 | Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. Page no-52 Item No-5(iii)80mm dia. (Recomended Oriplast Brand) |
| 22 | (b) 32 mm dia PVC pipe S-80 of ASTM-D-1785 approved Brand |
| 23 | Supplying, fitting and fixing reducing socket 80mm x 40mm PVC. |
| 24 | Supplying, fitting and fixing plug of approved make conforming to I.S. specification. 40mm dia. |
| 25 | Supplying and fixing of Solvent Cement |
| 26 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). |
| 27 | (a) 25 mm dia |
| 28 | (a) 15 mm dia |
| 29 | Supplying, fitting and fixing G.I. cap at top. 100mm |
| 30 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 31 | Supplying P.V.C. water storage tank of approved quality with closed top withlid (Black) - Multilayer. |
| 32 | Supplying, fitting and fixing cast iron raised rain proof tank cover 450mm. |
| 33 | Providing and fixing Submersible pump with necessary fittings and accessories with electric line installations etc(as per approved vendor & Model). |
| 34 | Providing and fixing Water purifer , Iron Reducer(Storage capasity -150Litre/Hr) as per approved Vendor and Modelwith necessary fittings and accessoriesetc.Brand - aqua. |
| 35 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No.511 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 36 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 37 | Digging earth in any soil including mixed soil but excluding moorum, laterite sand stone or any other hard stone including spreading or stacking the spoils within a lead of 75 metres as directed bailing out water upto 1 metre depth, shoring etc., when and if required and back filling with fine sand (including cost of sand) on completion of steining works. A) R.C.C. Ring Well. i) 1.2 metre diameter of digging for 0.9 metre internal diameter of well ring. a) Upto 3 metre below G.L. |
| 38 | R.C.C. well ring made with cement concrete 1:1.5:3 with stone chips and 0.80% reinforcement (including the cost of shuttering and reinforcement) cast at site fitted and fixed in position after proper curing true to plumb in the well including jointing with cement mortar 1:2 complete as per direction. a) 65 mm thick and 0.9 metre internal dia. cement for joint filling-4 kg/meter |
| 39 | Supplying, fitting and fixing self closing C.P. water tap of approved brand and make - 15 mm dia. and make - 15 mm dia. |
| 40 | Complete Electrification as necessary |
| 41 | Complete Fitting, Fixing of Electrict Light system Fyber Display board with all necessary equipment i.e Nut, Bolt, Angel etc. Size - 2.30M X 0.450M |
| 42 | GST |
| 43 | L Cess |