Tender For Co 03 Nos Residential Quarters(Sh Type Iii 01, Type Iv 01 And Type V 01 Nos) For Shq At Bsf Campus Gokulnagar Under Tripura Ftr.( Sh Electrical Work )
Tender Overview
Project Description
Co 03 Nos Residential Quarters(Sh Type Iii 01, Type Iv 01 And Type V 01 Nos) For Shq At Bsf Campus Gokulnagar Under Tripura Ftr.( Sh Electrical Work ) Co 03 Nos Residential Quarters Sh Type Iii 01, Type Iv 01 And Type V 01 Nos For Shq At Bsf Campus Gokulnagar Under Tripura Ftr ( Sh Electrical Work )
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 2 | (i) Group \"A\" |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable M S box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | (ii) Group \"B\" |
| 6 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required |
| 7 | Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire of FRLS PVC insulated Copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 10 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 11 | (i) 180 mm X 100 mm X 60 mm deep |
| 12 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 13 | i) 5/6 Amp Switch |
| 14 | ii) 3 pin 5/6 A Socket Out let |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 Amp Switch |
| 17 | 15/16 Amp Switch |
| 18 | 3 pin 5/6 A Socket Out let |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 20 | Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6& 15/16 amp socket outlet and 15/16 amp piano type switch, connection, painting etc. as required. |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 22 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 23 | Supplying and fixing call bell / buzzer suitable for single phase, 230 volts complete as required. |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 25 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 26 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 27 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | (i) 12 wayDouble door |
| 29 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 30 | a) 6 way (4 + 18), Double door |
| 31 | b) 8 way (4 + 24), Double door |
| 32 | Supplyingand fixing 5 ampto 32 amp rating 240 volts\"C\" curve miniature circuit breaker suitable for inductive load of following poles in the existingMCB DBcomplete withconnectiontesting and commissioning etc. as required. |
| 33 | a) Single pole,6ANos,16 A |
| 34 | b) Double pole -32 amp |
| 35 | c) TPN -32 amp |
| 36 | Earthingwith GI earth pipe4.5 metre long x 40 mm dia including accessories and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. (with charcoal or coke and salt)as required |
| 37 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 38 | Providing and laying earth connection from earth electrode with 6 SWG dia G I wire in 15mm dia G I pipe from earth electrode including connection with G. I. Thimble excavation and re-filling as required. |
| 39 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 40 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 41 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 42 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 43 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 44 | Supplying and Laying of size 63 mm dia(OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket,bend,couplers etc.conforming to IS 14930, Part II completed with fitting and cutting jointing etc.direct in ground(75 cm below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required |
| 45 | Supplying, Installation, testing and commissioning of 1200 mm , ISI marked double bearingceiling fan without regulator including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 46 | Supplying and fixing of 300 mm sweep, exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making hole to suit the size& S/F of louver / shutter including connections etc. as required. |
| 47 | Supplying, Installation, testing and commissioning of20LED battencool day light complete fitting, box type etc. as required including making connection etc. as required of make Bajaj/ Havells/ Philips/ Crompton. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required |
| 48 | Supplying, Installation, testing and commissioning of9LED battencool day light complete fitting, box type etc. as required including making connection etc. as required ,directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required |
| 49 | Supplying and fixing decorative wall mounted light fitting made of polycarbonate complete suitable for 1 x 9 wattLEDlamp(B-22 base)including 1 x 9 watt LED lamp & making connections etc. as required of make |
| 50 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 2X10 sqmmdirect in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 51 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 3.5x35 sqmm sq mm direct in the existing open duct /RCC/ HUME/ METAL pipe as required. |
| 52 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 3.5x95 sqmm sq mm direct in the existing open duct /RCC/ HUME/ METAL pipe as required. |
| 53 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 3.5x150 sqmm sq mm direct in the existing open duct /RCC/ HUME/ METAL pipe as required. |
| 54 | Supplying & fixing of 5 mtr long 65 mm dia G I pipe (medium duty),with making of suitable collar and suitable size base plate etc as required at site. |
| 55 | Supplying & fixing of SMC enclosure of size (140 x 140 x 95) mm with 6 amp SP MCB, terminals and accessories etc. as required. Make Sintex or equivalent |
| 56 | Supplying & fixing of 25 watt LED street light with aluminium body and toughened glass and secondary optical lens, with IP-66 protection 5700K with suitable size bracket including wiring with 3 x 1.5 Sqmm (from Pole to LED fitting), PVC insulated & PVC sheathed, multi core, copper condoctor cable & making connection of LED street light luminaire etc. as required |
| 57 | Supplying & fixing of 6 way SPN Double Door MCB DB Glazed door, IP 43 having following DIN type energy meters & MCBs including connections, interconnections withexisting 6 sqmm cable upto DP MCB & meter includingdismentalling of existing meter box etc. as reqd.(i) Digital energy meter, 3 phase, 10 - 60 amp, DIN mounting whole current operated energy meter, accuracy class 1.0, Displays day, week, month and push to push cosumption (voltage,current,kw,kwh) |
| 58 | S/ITC of outdoor type feeder piller, double door made out of 12 mm CRCA sheet duly primed & painted with synthetic enamel black paint of size not less then 1000 mm(height) x 800 mm (width) x 300 mm deep having 200 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door, R-Y-B LED indicators and Providing & fixing of internal connection with suitable size of copper wires, following accessories & angle iron frame of size 800 mm x 300 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. i)125 Amps, 4 pole, 415 volts, MCCB braking capacity 25 KA,1 Nos ii)100 Amps, 4 pole, 415 volts, MCCB braking capacity 16 KA, 1 Noiii)63 Amps, 4 pole, 415 volts, MCCB braking capacity 16 KA,3 Nos |
| 59 | S/ITC of outdoor type feeder piller, double door made out of 12 mm CRCA sheet duly primed & painted with synthetic enamel black paint of size not less then 1000 mm(height) x 800 mm (width) x 300 mm deep having 200 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door, R-Y-B LED indicators and Providing & fixing of internal connection with suitable size of copper wires, following accessories & angle iron frame of size 800 mm x 300 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. i)160 Amps, 4 pole, 415 volts, MCCB braking capacity 25 KA,1 Nos ii)125 Amps, 4 pole, 415 volts, MCCB braking capacity 16 KA, 1 Noiii)63 Amps, 4 pole, 415 volts, MCCB braking capacity 16 KA,3 Nos |
| 60 | Supplying and fixing electronic fan regulator(socket type) on the existing switch box including connections etc.asrequired |
| 61 | Supplying & fixingof Single Phae kWh meter with LCD display push to push cosumption (voltage,current,kw,kwh) 1 phase 5-30 amp in existing meter box i/c connections and testing,commissioning etc. as reqd. |
| 62 | Add 1 % Labour Cess |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender