Repair And Maintenance Of Sfp Mfp Loop Box Gear Boxes And Dg Set Panel At Various Bops Of 120 Bn Bsf Under Shq Bsf Gokulnagar. Sh1 Repair And Maintenance Of Various Panels Of Bfls Repair And Maintenance Of Sfp Mfp , Loop Box , Gear Boxes And Dg Set Panel At Various Bops Of 120 Bn Bsf Under Shq Bsf Gokulnagar. Sh1 Repair And Maintenance Of Various Panels Of Bfls .
BOQ
| Sl. No. | Item Description |
| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Providing & fixing MCCB, 160 amps, 4 pole, breaking capacity 36 KA, with suitable operating mechanism extended rotary handle in existing cubicle panel board including drilling holes in cubicle panel, making connections and dismentling of existing Switch gears etc. as required. |
| 3 | Providing & fixing MCX 32, 4 pole power contactor, 160 amp in existing cubicle panel board including drilling holes in cubicle panel, making connections and dismentling of existing Switch gears etc. as required. |
| 4 | Providing & fixing of 250 amps, 415 volt, type FN(TPN) switch disconnector fuse unit open execution with suitable for Bolted fuse link, size B2, conf. to IS/IEC 60947-3for fixing in existing Sheet Steel enclosure with door inter lock & pad lock facility, drilling holes i/c 03 Nos Bolted fuse link cat. No.ST30781 and complete with connections, testing and commissioning an and complete with connections, testing and commissioning and dismentling of existing fuse switch units (disconnectors) etc. as required. |
| 5 | Providing & fixing of 125 amps, 415 volt, type FN(TPN) switch disconnector fuse unit open execution with suitable for Bolted fuse link, size A4, Fr 2, conf. to IS/IEC 60947-3 for fixing in existing Sheet Steel enclosure with door inter lock & pad lock facility, drilling holes i/c 03 Nos bolted fuse link cat. No.ST30769 and complete with connections, testing and commissioning and dismentling of existing fuse switch units (disconnectors) etc. as required. |
| 6 | Providing & fixing of 63 amps, 415 volt, type FN(TPN) switch disconnector fuse unit open execution with suitable for Bolted fuse link, size A1L, Fr 1, conf. to IS/IEC 60947-3 for fixing in existing Sheet Steel enclosure with door inter lock & pad lock facility, drilling holes i/c 03 Nos bolted fuse link cat. No.SK95704 and complete with connections, testing and commissioning and dismentling of existing fuse switch units (disconnectors) etc. as required. |
| 7 | Providing & fixing of 32 amps, 415 volt, type FN(TPN) switch disconnector fuse unit open execution with suitable for Bolted fuse link, size A1L, Fr 1, conf. to IS/IEC 60947-3 for fixing in existing Sheet Steel enclosure with door inter lock & pad lock facility, drilling holes i/c 03 Nos bolted fuse link cat. No.SK95518 and complete with connections, testing and commissioning and dismentling of existing fuse switch units (disconnectors) etc. as required. |
| 8 | Providing and fixing Digital 3 phase multifunction meter in existing cubicle panel board including,making connections etc.as required. Make L&T code no.WL441010OOOO |
| 9 | Providing,Installation, Testing and commissioning of spare coils (for four pole MCX 32 contactors) 240 volt, AC, cat. No.CS94196 L& T make. Etc. as required. |
| 10 | Supplying & fixing of 3 Nos LED indicator 16 mm surface mounted low power consumption,surge & low voltage glow protection cat. no.SIL, in the Red, yellow and Blue colours, L&T make, including connections with 0.75 sqmm FR LS single core copper conductor cable etc. as reqd. |
| 11 | Providing & fixing of 125 amps, 415 volt, Bolted fuse link suitable for 125 amps disconnector fuse unit, size A4, conf. to IS/IEC 60947-3 and testing, commissioning and dismentling of existing fuse etc. as required. |
| 12 | Providing & fixing of 63 amps, 415 volt, Bolted fuse link suitable for 63 amps disconnector fuse unit, size A1L, conf. to IS/IEC 60947-3 and testing, commissioning and dismentling of existing fuse etc. as required. |
| 13 | Providing & fixing of 32 amps, 415 volt, Bolted fuse link suitable for 32 amps disconnector fuse unit, size A1L, conf. to IS/IEC 60947-3 and testing, commissioning and dismentling of existing fuse etc. as required. |
| 14 | Providing & fixing of 250 amps, 415 volt, DIN type fuse link suitable for 250amps disconnector fuse unit, size 1, conf. to IS/IEC 60947-3 and testing, commissioning and dismentling of existing fuse etc. as required. |
| 15 | Providing & fixing of spreader terminals 4P,suitable for 160 amps MCCB, 4 pole, breaking capacity 36 KA, making connections etc. as required.compitable to L&T make cat. No. CM92007OOOO (set of 8) |
| 16 | Supplying & fixing of 0-600 V, 3-phase 50 Hz Voltmeter including connections and dismantelling of existing voltmeter etc. as reqd. |
| 17 | Supplying & fixing of 0-200 A, 3-phase 50 Hz Ampere meter including connections and dismantlling of existing ampere meter etc. as reqd. |
| 18 | Add Labour cess@ 1% on total |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender