Tender For Water Supply Arrangement Under Urban Water Supply Scheme Of Dws Division Ambassa During The Year 2021-22/ Sh: Repairing In/C. Rewinding Of Existing Vt Pump With Motor Sets, Starter Main Switch Electrical Panel Boards, Suction Line Etc And Other, dhalai-Tripura

Public Works Department-PWD has published Tender For Water Supply Arrangement Under Urban Water Supply Scheme Of Dws Division Ambassa During The Year 2021-22/ Sh: Repairing In/C. Rewinding Of Existing Vt Pump With Motor Sets, Starter Main Switch Electrical Panel Boards, Suction Line Etc And Other. Submission Date for this Tender is 27-03-2023. Water Supply Project Tenders in dhalai Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

36603926
Tender For Water Supply Arrangement Under Urban Water Supply Scheme Of Dws Division Ambassa During The Year 2021-22/ Sh: Repairing In/C. Rewinding Of Existing Vt Pump With Motor Sets, Starter Main Switch Electrical Panel Boards, Suction Line Etc And Other
Open Tender
Indian
Tripura
dhalai
27-03-2023

Tender Details

Water Supply Arrangement Under Urban Water Supply Scheme Of Dws Division Ambassa During The Year 2021-22 / Sh: Repairing In / C. Rewinding Of Existing Vt Pump With Motor Sets, Starter Main Switch Electrical Panel Boards, Suction Line Etc And Other Works Of 0.55 Mgd Capacity Surface Water Treatment Plant At Kulai Under Dws Sub-Division Ambassa

Key Value

Document Fees
INR 1000 /-
EMD
INR 19401.0 /-
Tender Value
INR 9.70 Lakhs /-

BOQ Items

Name of Work: Water supply arrangement under Urban Water Supply Scheme of DWS Division Ambassa during the year 2021-22/ SH: Repairing in/c. rewinding of existing VT pump with motor sets, starter main switch electrical panel boards, suction line etc and other works of 0.55 MGD capacity Surface Water Treatment Plant at Kulai under DWS Sub-Division Ambassa.
Sl. No. Item Description
1Charges for lifting of pump, motor, column pipe etc. from intake well and stacking the same at suitable place as per specification and the direction of the Engineer-in-charge.
2Rewinding of Horizontal Motor suitable forcentrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-incharge.
3A) 1-1.5 HP pump motor set
4Rewinding of Motor suitable V.T. pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-incharge.
5a) 50-65 HP
6Providing and fitting fixing of Fully Automatic star Delta type motor starter (3 ph, 50 HZ, 415v, 50 HP/37 kw Relay range within 28-42 + 10% ) in steel sheet enclosures with contractors and timer etc. complete suitable for submersible pump L&T, BCH, ABB make as per specification and direction of the Engineer-incharge.(i) 50 HP/37 kw Relay range within 45-70 + 10%
7Providing & fitting fixing with pvc insulated single core multistand copper cable conforming to IS: 694 for inter connection with all electrical equipments of the panel board as per specification & direction of the Engineer-in-charge.
8i) 10 sqmm
9Providing for fitting-fixing CI sluice valve (with cap) complete with bolts, nuts, ruber insertions etc ( the tail pieces if require will be paid seperately) as per specification & direction of the Engineer-in-charge.
10i) 200 mm dia A. PN-1.6
11Repairing of V.T. pumps by providing and replacing of G.M. bush for bowel ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
12i. for 40000 / 50000 GPH capacity V.T. pump
13Repairing of V.T. pumps by providing and replacing of G.M. bush for suction case / discharge case ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
14i. for 40000 / 50000 GPH capacity V.T. pump
15Repairing of V.T. pumps by providing and replacing of Rubber bush for bowel ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
16i. for 40000 / 50000 GPH capacity V.T. pump
17Repairing of V.T. pumps by providing and replacing of bronze impeller ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
18i.for 45000 / 50000 GPH capacity V.T. pump
19Repairing of V.T. pumps by providing and replacing of MS lock ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
20(i) For 40000 / 50000 GPH capacity V.T. pump
21Providing and fitting fixing of stainless steel pmp shaft (SS-410 IS: 1570 part-v)for 40000 / 50000 GPH capacity V.T. pump
22Providing and fitting fixing of column shaft 25mm dia 5 ft length (FN-8).
23Providing and fitting fixing of column shaft 25mm dia 10 ft length (FN-8).
24Providing and fitting fixing of Top shaft 25mm dia 8 ft length (FN-8).
25Labour charge for lowering ofV. T. pump motor with a column pipes of required depthin/c. fitting fixing of nuts & bolt and rubber insertionwith making satisfactory trial run of pump motor etc complete as per direction of the Engineering-in-charge.
26Providing and fitting fixing with PVC insulated 3 coreflat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. (a) 6 sqmm
27Providing and fitting fixing Single phasing preventor +selectable under voltage +selectable over voltage on delay 5 sec & off delay 15 sec phase asymmetry 10% L & T /BCH/HAVELS/Siemens etc. make complete as per specification and direction of the Engineer-in-charge.
28Providing and fitting fixing low voltage AC TEFC squiral cage induction motor suitable for415V(+)(-)10% , 3 phase supply, foot mounted (B3 construction) continuous rated (S1 delay) with bare shaft & key as per IS:12615/IEC:60034-1 LNT/BCH/HAVELS/Siemens etc. make complete as per specification and direction of the Engineer-in-charge.
29(i) For 0.5 HP/0.37 Kw
30(ii) For 1.00 HP/0.75Kw
31(iii)For 1.5 HP/1.10Kw
32Providing and fitting fixing Worm Reduction Gearbox suitable to thelow voltage AC TEFC squiral cage induction motor complete LNT/BCH/HAVELS/Siemens etc. makeas per specification and direction of the Engineer-in-charge.
33(i) Type 200A, Ratio 70/1
34(ii) Type 237A, Ratio 60/1
Disclaimer :