}

Tender For Shifting Of 11 Kv Line By Laying Of Ug Cable With Rmu Of Feeder-1 And Vss Nagar From Arss Chhowk To Odcl Chhowk Due To Construction Of Railway Over Bridge Bhubaneswar For The Year 2022-2023, khurdha-Odisha

Civil Engineering Department has published Tender For Shifting Of 11 Kv Line By Laying Of Ug Cable With Rmu Of Feeder-1 And Vss Nagar From Arss Chhowk To Odcl Chhowk Due To Construction Of Railway Over Bridge Bhubaneswar For The Year 2022-2023. Submission Date for this Tender is 16-03-2023. Feeder Pillar Tenders in khurdha Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

36603591
Tender For Shifting Of 11 Kv Line By Laying Of Ug Cable With Rmu Of Feeder-1 And Vss Nagar From Arss Chhowk To Odcl Chhowk Due To Construction Of Railway Over Bridge Bhubaneswar For The Year 2022-2023
Open Tender
Indian
Odisha
khurdha
16-03-2023

Tender Details

Shifting Of 11 Kv Line By Laying Of Ug Cable With Rmu Of Feeder-1 And Vss Nagar From Arss Chhowk To Odcl Chhowk Due To Construction Of Railway Over Bridge Bhubaneswar For The Year 2022-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 120800.0 /-
Tender Value
INR 1.20 Crore /-

BOQ Items

Name of Work: Shifting of 11 KV Line by laying of UG Cable with RMU of Feeder-1 & VSS Nagar from ARSS Chhowk to ODCL Chhowk due to construction of Railway over Bridge Bhubaneswar for the year 2022-2023
Sl. No. Item Description
1Part- A (1)Laying of 3Core, 400sqmm, UG cable with spare cable(0.72KmX2)= 1.44Km Installation of 11KV 4way RMU-1No. Supply of 11kV, 3Core, 400sqmm, XLPE insulation armoured UG cable (SC rating of cable in kA- 37.7kA and SC rating of Armour in kA- 15kA)
2Supply of Straight through jointing kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, Aluminium UG cable for 3Core (Set)
3Supply of Indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, HT UG cable for 3Core (Set)
4Supply of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, HT UG cable for 3Core (Set)
5Supply of HDPE PE 80-PN8 pipe of 160mm diameter (for 400sqmm HT cable laying)
6Supply of 11kV RMU 4 Way, 2 Iso & 2 Brk 630A (LLVV)
7Earthing Conductor: 50X6 mm (2.4kg./mtr.) GI Flat for equipment, structure etc.)
8Pipe Earthing 40mm. GI Pipe
9Supply of End Connector
10Supply of standard FRTU
11Earth work excavation of soil
12Earth work excavation of hard rock
13Back filling with excavated soil outside and above the trench
14Damage of asphalt/tar road and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr. width)
15Prefabricated RCC foundation of 11kV RMU
16Supply of GI Fencing with Gate around each RMU
17Installation ofEarthPit, Charcoal, Salt etc. including construction of earthing chamber (Size: 2"x2") and RCC slab cover
18Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)
19Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works
20Installation of 11KV 4way RMU-1No. Description of itemsLaying, Commissioning, Testing of 11kV, 3core, 400sqmm, aluminium, XLPE insulation armoured (extruded type) UG cable by open trench method.
21Erection of Straight through jointing kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set)
22Erection of Indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set)
23Erection of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set)
24Laying of 160mm dia PE 80-PN8, HDPE pipe inside open trench.
25Erection of 11kV RMU 4 Way, 2 Iso & 2 Brk 630A (LLVV)
26Erection of RMU 3W 11kV 630A with metering unit (LLV+M)
27Erection of RMU 4W 11kV 630A with metering unit (LLVV+M)
28Part- B (2) Construction of 11KV Line DP with AB Switch -8Nos Description of Materials WPB 160x152 (11Mtr. Long, 30.44KG/Mtr.)
29Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no"s channel required =( 2x9.56x3)
30Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no"s required = (6x2.36x0.280)
31AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no"s channel required =( 7.14x3x2)
32AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no"s channel required =( 9.56x2x0.35)
33Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no"s channel required =( 7.14x0.8x1)
34Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no"s channel required =( 7.14x3x4)
3550x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)
36Danger Plate, 2 no"s.
37Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no"s = (2x0.59x0.510)
38H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no"s qty. required ( 1 Pair)
39H.T. Stay set (Complete )
40H.T. Stay Insulator Type-C
417/10 SWG Stay Wire 15kg /stay
42Gi Pipe Earthing 40mm. 3 Mtr. Long
4350x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36
44GI barbed wire anticlimbing device 3 Kg. Per support, 2 no"s qty. required=(2x3kg)
45Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no"s = (8x0.59x0.510)
46Lightning Arrester(12KV,10KA) (Station Class,class-2)
47AB Switch (11KV,400A.3pole,50Hz)
4811 KV pin insulator polymer
49H W fitting(B&S) 70KN, 3Bolt
50Disc insulator (B&S) 70 KN polymer
51PG Clamp for 55 sq.mm AAA conductor
52GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)
53Black Paint
54Yellow Colour Paint for Background
55Part-B(3) Dismantling of 11KV RS joist Pole-10Nos. Dismantling of 11KV Line- 400Mtr. Dismantling 11KV Line DP-2No. Description of MaterialsDismantalling of RS Joist Pole
56Dismantalling of V Cross Arm
57Dismantalling of conductor
58Dismantalling of Existing Line DP
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail