Tender For Repair/Replacement Of Summer/Cooling Appliances In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Replacement Of Summer/Cooling Appliances In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow. Submission Date for this Tender is 29-03-2023. Air Conditioner Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36597620
Corrigendum : Tender For Repair/Replacement Of Summer/Cooling Appliances In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
29-03-2023

Tender Details

Repair / Replacement Of Summer / Cooling Appliances In The Area Of Age E / M Ext ( Ws ) Under Ge E / M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Mar-2023 Corrigendum1 BOQ 22-03-2023
2 18-Mar-2023 Corrigendum2 Other 22-03-2023
3 22-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF SUMMER/COOLING APPLIANCES IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Dismantling of existing repairable split AC 1.5TR/2.0 TRWindow AC, 1.5/2.0 TRof any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
2Supply onlyrunning capacitor ofcapacity 36 Mfd in plastic container complete all as specified and directed.
3Supply supply only running capacitor ofcapacity 50+5Mfdin plastic container complete all as specified and directed.
4Supply supply only running capacitor ofcapacity 45 Mfdin plastic container complete all as specified and directed.
5Supply only Air Censor for temperature controlfor 1.5 TR / 2 TR compressor complete all as specified and directed.
6Supply only Swing motor for 1.5 TR / 2 TR indoor unit of split type invertor/normal air conditioner complete all as specified and directed.
7Supply only Swing motor for 1.5 TR / 2 TR window AC complete all as specified and directed. (Make :- Carrier/Voltas/LG).
8Supply onlybrass suction valve size 3/8" complete all as specified and directed.
9Supply only Discharge valve size 1/2" complete all as specified and directed.
10Supply onlycharging valve 1/4" dia for carrier make split AC complete all as specified and directed.
11Supply only flare nuts size 3/8" complete all as specified and directed.
12Supply only flare nuts size 1/4" complete all as specified and directed.
13Supply only flare nuts size 1/2" complete all as specified and directed.
14Supply only flare nuts size 5/8" complete all as specified and directed.
15Supply only copper Gas filter for AC 1.5 TR / 2 TR capacity complete all as specified and directed.
16Supply only PVC insulated three core stranded copper cable of size 80/0.20 (2.5 sqmm) complete all as specified and directed.
17Supply onlyMCB SP -6 to 32 Amps ratingto be housed in DBs catered here in after complete all as specified and directed.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
18Supply onlyMettalic Plugs ( top) of AC box 20A, specified make , 2P+Eand connecting complete all as specified and directed.
19Supply only of puff insulation of size1/2" suitable for 1.5 TR/2.0 TR AC complete all as specified and directed.
20Supply only of puff insulation of size1/4" suitable for 1.5 TR/2.0 TR AC complete all as specified and directed.
21Supply only of puff insulation of size5/8" suitable for 1.5 TR/2.0 TR AC complete all as specified and directed.
22Supply and Fix in repair copper capillary of size 0.60 mm complete all as specified and directed.
23S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified and directed.
24Supply and fix PVC pipe nylon imbraided 15 mm dia forcondensed waterdrain fitted with clamps/concealed in wall complete all as specified and directed.
25Supply and fix in repairof copper tubing 3/8"dia complete all as specified and directed.
26Supply and fix in repairof copper tubing 1/2" dia complete all as specified and directed.
27Supply and fix in repairof copper tubing 1/4" dia complete all as specified and directed.
28Supply and fix remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed. (Make:- LG / Samsung / Bluestar)
29Supply and fixremote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and includingpencil cells complete all as specified and directed. (Make:- LG / Samsung / Bluestar)
30Supply and fix PVC fan blade with gun metal bush of blower , Screw complete as per complete all as specified and directed.
31Supply and fixPVC runner for window A.C. as per sample complete all as specified and directed.
32M&L for taking down of Split type AC of any capacity or model and transporting and refixing at New Location including testing of leakage and charging/top up of specified gasas per the make of the AC and make it fully functional again at new location with complete all as specified and directed.
33Taking out defective blower motor from window type AC of cap 1.5/2.0 TR oroutdoor unit of Split type AC of capacity 1.5 TR / 2 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HPblower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
34Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC double shaft ( indoor unit)and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed.
35Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC single shaft (outdoor unit)and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample completeall as specified and directed.
36Dismantling of existing window type AC. from its location andrefixingafter doing the following repairs wherever required complete all as specified and directed. (a) Servicingby oiling & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filtercomplete with cleaning of Cooling & Condensing coil complete all as specified and directed. (b) M&L for painting of outer cage and front grillwindow type A/C with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paperincluding writing SM No. / MES No. etc with front of grill complete all as specified and directed.
37Renewal ofplywood 6 mm thick, BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished complete all as specified and directed.
38Dismantling of defective indoor unit of 1.5 TR capacity split typeAC and supply & fixing indoor unit of the same capacitywith blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and directed.
39Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply & fixing new condensing unitcomplete with compressor,condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade complete all as specified and directed. (Make :- Totaline/ Bluestar/ Acent/Skoda/ Opel/LG)
40Dismantling of defective cooling coil of 1.5 TR window type AC of any make and S&Fcooling coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed.
41Dismantling of burntfan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing newfan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed.
42Dismantling of unserviceable compressors of 1.5 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make –Carrier/ Kirloskar/ Blue star
43Dismantling of unserviceable compressors of2 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make –Carrier/ Kirloskar/ Blue star
44Dismantling of unserviceable compressors of 1.5 TRcapacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make –Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
45Dismantling of unserviceable compressors of 2 TRcapacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
46Supply and fixing in repairs front grill quality for window AC of 1.5 TR/ 2 TRof Make National/ Casmo/LG/Carrier / Blue Star/Samsung complete all as specified and directed.
47M & L for servicing of Split AC,s 1.5/2.0 TR Indoor/out door unit by means of electric blower & water under pressure,cleaning & washing of cooling/condencing coilby soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete all as specified and directed.
48M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR capacity split type AC complete all as specified and directed. (Note :- The refrigerant gas will be providedby Contractor)
49M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging of refrigerant gas R-22/R-32/R-410 into the system for 2.0 TR capacity split type AC complete all as specified and directed. (Note :- The refrigerant gas will be providedby Contractor)
50M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging of refrigerant gas R-22/R-32/R-410 into the system for 1.5/2.0 TR capacity window type AC complete all as specified and directed. (Note :- The refrigerant gas will be providedby Contractor)
51Supply & Charging (Top up) the AC unit of 1.5 TR / 2 TR split type,window AC unit with refrigerant gas R-22/R-32/R-410/R-134 in required Qty complete all as specified and directed.
52S&F reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed.
53S&F in replacement New PCB for indoor unit of (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC ( hot & cold) complete all as specified and directed.
54M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC of any make &(cooling only/hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
55All as per item 54 above but for 1.5/2.0 TR WINDOW AC of any make.
56S&F in replacement New PCB for indoor unit of (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as .specified and directed.
57S&F in replacement New PCB for Outdoor unit (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as specified and directed.
58M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type of any make &(hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
59Dismantling ,desetr cooler,of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
60Supply only of PVC front grill complete all as specified and directed.
61Supply onlyof Piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. (Make :-Anchor/ABB/Havelles)
62Supply only of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler complete all as specified and directed.
63Supply onlyofPVC distributor suitable for 15 mm dia PVC Pipe, PVCelbow & connection of PVC pipe from pump to distributor suitable for 18"/24" sweep desert cooler complete all as specified and directed.
64Supply Onlyof PVC connection 15 mm dia with brass ferule both and length 600 mm complete all as specified and directed.
65Supply only of PTMT float valve , 15 mm dia complete all as specified and directed(Make Prayaga)
66Supply only of copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed.
67Supply only of copper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed.
68Supply only of PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and directed.
69Supply only of replacement submersible pump for desert cooler single phase, 1/40 HP,230volts complete all as specified and directed.
70Supply only of Exhaust fan blades 18"/20" sweep heavy duty(as per sample) complete all as specified and directed.
71Supply only of wood wool pad (As per sample) suitable for desert cooler325 mm to 500mm sweep complete all as specified and directed.
72M&L for renewal of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"sweep size suitable for desert cooler complete all as specified and directed. (Make:- Crompton /Champion /Summer Cool/Usha)
73M&L renewal of exhaust fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"/20"sweep size suitable for desert cooler complete all as specified and directed. (Make:- Champion/Crompton greaves/Khaitan/Usha)
74Taking out defective burnt exhaust fan offollowing sweep and of any makeand transporting tocontactor"s workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18"/24" size (exhaust fan) complete all as specified and directed.
75S&F in repairs worn out wiremesh rectangular / square fitted with all the three side panels of desert cooler of 15"/24" any makemade out of 24 SWG 10mm apertureincluding rivetting and renewing the cut wood pads complete all as specified and directed. (Renewal of Wood pads shall be measured and paid separately).
76Renewal of set of panels made out of PGI sheet24 gauge thick with wood wool pads, in required quantity duly filled complete all as specified and directed.
77Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan, made out of 24 gauge PGI sheet with front grill and side panel with switch regulator complete all as specified and directed. (Make :- Champion/Summerking)
78Taking out carefully 325 to 500/600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) after preparation of old painted surfaces and reassembling and fixing in positionincluding, complete all as specified and directed.
79Dismantling of existing repairablewater coolerof any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
80Supply only ofCP pipe connectorincluding flange, screw, CP nozzle of nipple, female nozzle and extentioncomplete all as specified and directed.
81Supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/10 hp capaciitescomplete all as specified and directed.
82Supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/16 hp capaciitescomplete all as specified and directed.
83Supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/8 hp capaciitescomplete all as specified and directed.
84Supply only ofblower motor with bladeAC 240 volts, 50 HZ single phase, of 25 watts capaciitescomplete all as specified and directed.
85Supply only of aluminium fan blade of blower motor of 1/16 HP complete all as specified and directed.
86Supply only ofPVC fan blade of blower motor of 1/8 HP complete all as specified and directed.
87Supply only of PVC fan blade of blower motor of 1/10 HP complete all as specified and directed.
88Supply and fix in repaircondensing coil for 150 litres Capacity water cooler of any make complete all as specified and directed.
89Supply and fix in repaircondensing coil for 60/120 litres Capacity water cooler of any make complete all as specified and directed.
90Supply onlyCP Brass push cock(inner or outer threaded) of 15 mm bore size complete all as specified and directed.
91Supply only of 32 mm PVC pipe with clip and strainer tee Elbow complete all as specified and directed.
92Supply only of starting relay for 1 TR water cooler complete all as specified and directed .
93Supply only of starting relay for 1/3 TR water cooler complete all as specified and directed .
94Supplyonly of runnuing capacitor (conforming to IS:2993 - 1975) AC 230 volts in plastic container 6 mfd complete all as specified and directed .
95Supply only ofcapacitor for blower motor of water cooler of 2.5 Mfd capacity all as specified and directed
96Supply onlyof capacitor for blower motor of water cooler of 4.00 Mfd capacity all as specified and directed
97Supply only of running capacitor(conforming to IS:2993 - 1975) AC 440 volts in plastic containerof 10 mfd capacities complete all as specified and directed.
98Supply only of running capacitor(conforming to IS:2993 - 1975) AC 440 volts in plastic containerof 36 mfd capacities complete all as specified and directed.
99Supply only of overload protector for 1.00 TR compressor complete all as specified and directed .
100Supply only of overload protector for 1/3TR compressor complete all as specified and directed .
101Supply only of Thermostat long tail for water cooler complete all as specified and directed.
102Supply only of Thermostat short tail for water cooler complete all as specified and directed.
103Supply only of gas filter, flare type, 3/"x 1/2" flare, complete all as specified and directed.complete all as specified and directed.
104Supply only offloat valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified and directed.
105M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaceswithout disturbing the components & wiring etc. complete and reconnceting complete all as specified and directed.
106All as per item No 105 above but for 40 / 80 Litres capacities of water coolers
107All as per item No 105 above but for 60 / 120 Litres capacities of water coolers
108Checking of leakage in refrigerant system of water cooler of 150 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
109Checking of leakage in refrigerant system of water cooler of 60/120 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
110Checking of leakage in refrigerant system of water cooler of 40/80 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
111Transporting defective blower motor of 1/ 16 HP capacities from AGE E/Myard to contractor"s workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wireincluding insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed.
112All as per item No 111 above but for capacity of 1/8 HP
113Dismantling of existing repairablerefrigerator any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
114Supply only starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and directed.
115Supply onlyover load protector for 1/6 HP refrigerator of capacity 165/300/310 litres complete all as specified and directed.
116Supply onlythermostat defrost type for refrigerator complete all as specified and directed.
117Supply onlys thermostat non defrost type for refrigerator complete all as specified and directed.
118S&F in reapairPCB for 300/310 ltr refrigerators, complete all as specified and directed. (Make-Samsung/LG or others as required)
119S&F in repair PCB for 300/310 ltr refrigerators (Inverter type), complete all as specified and directed. (Make-Samsung/LG or others as required)
120S&F in repair Freezer for capcity 165/180/210 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required)
121S&F in repair Freezer for capcity 300/310 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required)
122S&F condensing coilof 165/190/195 litres capacitiesrefrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging ofNon CFC gas as per required quantity and testing complete all as specified and directed.
123All as per item 122 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
124Checking of leakage in refrigerant system ofrefrigerator of 165/190/195 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
125Checking of leakage in refrigerant system ofrefrigerator of 286 /300/310 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
126Dismantling of existing repairableDeep freezer any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
127Supply onlystarting relay for 200 Ltr. Capacity deep freezer complete all as specified and directed.
128Supply only starting relay for 300 Ltr. Capacity deep freezer complete all as specified and directed.
129Supply only over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed.
130Supply only running capacitor for 200/300 Ltr capacity deep freezer complete all as specified and directed.
131Supply only thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
132Supply only starting capacitor for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
133Taking down defective compressor of following capacity of deep freezer of any Make and depositing ,supply andfixing sealed unit compressor as specified here underincluding brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and directed.
134All as per item No 133 above but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
135Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
136Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hzincluding disconnection and reconnecting and testing complete all as specified and directed.
137Taking down unserviceable voltage stablizers ofany make of following capacities and dismantling the stablizers of any size for repair of the defective parts/spares & ressembling including repairs of defective screws, rubber shose testing complete all as specified and directed Note:- Spare parts measured and paid seprately
138Supply only relay 25/30 Amps 24 volts for 4 KVA/5KVA voltage stablizers complete all as specified and directed
139Supply only main PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed
140Supply only 2 mtr long copper cable 3 core PVC insulated and sheathed 80/.20(2.5 Sqmm) size duly fitted with 3 pin top 20 Amps complete all as specified and directed.
141Supply only power transfromers suitable for voltage stablizers of capacity 4/5 KVAcomplete all as specified and directed.
142Supply only AC volt meter square/round type 0-300 volts suitable for 5/4 KVA single phase voltage stablizers complete all as specified and directed.
143Supply and fix in repair of dimmer type transfromer for 4KVa/5KVA Voltage stablizers complete all as specified and directed.
144Supply and Fix in repair copper capillary of size 0.60 mm complete all as specified and directed.
145Supply and fix in repairPolycarbonate Plug top 3 pin16 Amp complete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S .
146Supply and fix in repair Polycarbonate Plug top 3 pin 5/6 Amp complete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S