Tender For Supply Of 6 Kva Online Ups
Tender Overview
Project Description
Supply Of 6 Kva Online Ups Supply Of 6 Kva Online Ups For Mech Department , 6 Kva Online Ups: , 6 Kva Online Ups 6 Kva Online Double Conversion Igbt Based H-Bridge Pwm Technology Using Micro Controller Under Low Supersonic Frequency 12 Khz Switching 120 Vdc Operated Ups With Wide Range Individual Step Down And Step Up Transformers For Converting And Inverting 1 Hour Backup Using 12 V, 42 Ah Smf Battery – 10 Nos. Input Parameters: Input Supply: 1F Input, 230 Vac + 10% Input Frequency : 50 Hz + 1% Dc Converter: Bridge Rectifier Using 96 Amps Thyristor Module With Lc Filters Dc Volt At Charging: 135 Vdc Floating Dc Current Control: Using 75 Amps Dc Shunt Dc Fuse Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link Input Fuse Protection:Using 63 Amps Black Lite Carrier With Hrc Fuse Link Output Parameters: Output Supply: 1F220 Vac + 0.5% Output Frequency : 50 Hz + 0.1% Inverter Bank: H-Bridge Using Two Nos. Of 150 Amps Igbt Module Inverter Transformer: Step Up Transformer Primary : 0-65 Vac, 60 Amps Secondary: 0-230 Vac, 30 Amps Inverter Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link Output Fuse Protection: Using 63 Amps Black Lite Carrier With Hrc Fuse Link By-Pass Switch Provision Provided By 40 Amps Rotary Switch Display: Lcd / Led Display For Output Volt, Dc Volt Led Indication: Mains On / Input On, Inverter / Ups On, Dc Low, Over Load
BOQ
| Sl. No. | Item Description |
| 1 | 6 kVA online UPS: |
| 2 | 6 kVA online UPS6 kVA online double conversion IGBT based H-bridge PWM Technology using micro controller under low supersonic frequency 12 kHZ switching 120 VDC operated UPS with wide range individual step down and step up transformers for converting and inverting 1 hour backup using 12 V, 42 AH SMF Battery – 10 Nos.Input Parameters:Input supply: 1F input, 230 VAC + 10%Input frequency : 50 HZ + 1%DC Converter: Bridge rectifier using 96 Amps Thyristor module with LC filtersDC Volt at charging: 135 VDC floatingDC current control: using 75 Amps DC shuntDC Fuse protection: using 63 Amps black lite carrier with HRC fuse linkInput Fuse protection:using 63 Amps black lite carrier with HRC fuse linkOutput Parameters:Output supply: 1F220 VAC + 0.5%Output frequency : 50 HZ + 0.1%Inverter Bank: H-bridge using two nos. of 150 Amps IGBT moduleInverter Transformer: Step up transformerPrimary : 0-65 VAC, 60 AmpsSecondary: 0-230 VAC, 30 AmpsInverter Protection: using 63 Amps black lite carrier with HRC fuse linkOutput Fuse protection: using 63 Amps black lite carrier with HRC fuse linkBy-pass switch provision provided by 40 Amps rotary switch Display: LCD / LED display for output volt, DC voltLED indication: Mains on / Input on, Inverter / UPS on, DC low, over load |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender