Tender For Nabard-Infrastructure Work In Taluk Hospital(Phase2)At Vaikom, Kottayam-Installation Ofadditional Split Air-Conditioner Unitsand Its Allied Electrical Works -Electrical Ac Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Mar 2023
0 days left
EMD
23992
Bank guarantee accepted
Document Fee
2120
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vaikom → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Nabard-Infrastructure Work In Taluk Hospital ( Phase2 ) At Vaikom, Kottayam-Installation Ofadditional Split Air-Conditioner Unitsand Its Allied Electrical Works -Electrical Ac Work
BOQ
| Sl. No. | Item Description |
| 1 | Air conditioning |
| 2 | OD244278/2022-2023:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 1.5 TR 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Carrier/Mistubishi)-- |
| 3 | OD244279/2022-2023:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 2 Tr 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Carrier/Mistubishi)-- |
| 4 | OD231476/2022-2023: Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 1 Tr 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Mitsubishi/carrier)-- |
| 5 | OD237101/2022-2023:Supply ,providing and fixing ISO wall panel (PUF panel) for covering indoor unit duct able split AC and return air box for ducting |
| 6 | OD249068/2022-2023:Providing and fixing false ceiling at all height including providing and fixing of frame workmade of special sections, power pressed from M.S. sheets and galvanized with zinc coating of120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, oneflange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts& bolts of required size and other end of angle hanger fixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at everyjunction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered andsquare edges of the board with recommended jointing compound, jointing tapes, finishing withjointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also including the cost ofmaking openings for light fittings, grills, diffusers, cutouts made with frame of perimeterchannels suitably fixed, all complete as per drawings, specification and direction of theEngineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1 |
| 7 | OD231468/2022-2023: Supply and providing stand/frame set for the outdoor unit on the wall with necessary screws etc: as required, |
| 8 | OD244280/2022-2023:upply & drawing drain piping for the condensate drain water to the nearest drain point with 25 mm PVC pipe with nitrile rubber tube insulation. |
| 9 | OD244281/2022-2023:Supply, fixing & giving connection of 4 KVA voltage stabilizer with voltage range of 175-275V and out put range of 210 - 240V suitable for 1.5 TR split type A/C unit |
| 10 | OD244282/2022-2023:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent) - |
| 11 | OD244283/2022-2023:Supply and providing the following size soft drawn copper pipe for connecting Indoor and Out Door unit using rubberized foam sleeve 10 mm thick, brazing, leak testing etc. 9 mm (3/8 inch) , 16 mm (5/8 inch) dia, 22g - |
| 12 | OD244284/2022-2023:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.1/4\"(6.35mm) and 1/2\"(12.7mm) 22 gauge.-- |
| 13 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 14 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 15 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 16 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 17 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 18 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 19 | 90.6.5.20:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm |
| 20 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 21 | 1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm |
| 22 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 23 | 1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm |
| 24 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 25 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 26 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 27 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 28 | 2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 29 | OD250631/2022-2023:supply & installation of dust and vermin proof, wall mounting, Sintex SMC box of following size suitable for fixing 4 pole Isolator (GSJB 2014) or equivalent |
| 30 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
AI Tender Summary
Tender Timeline
Mar 03, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMar 13, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 15, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender