Housing Urban and Rular Development Government Departments Closing in 0 days TDR #36590460

Tender For Nabard-Infrastructure Work In Taluk Hospital(Phase2)At Vaikom, Kottayam-Installation Ofadditional Split Air-Conditioner Unitsand Its Allied Electrical Works -Electrical Ac Work

Issued by Government Departments · vaikom, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Mar 2023
0 days left
EMD
23992
Bank guarantee accepted
Document Fee
2120
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vaikom → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Nabard-Infrastructure Work In Taluk Hospital ( Phase2 ) At Vaikom, Kottayam-Installation Ofadditional Split Air-Conditioner Unitsand Its Allied Electrical Works -Electrical Ac Work

BOQ

Work Name:NABARD-Infrastructure Work in Taluk hospital(Phase2)at Vaikom, Kottayam-Installation ofadditional Split Air-Conditioner unitsand its allied electrical works -Electrical AC Work
Sl. No. Item Description
1Air conditioning
2OD244278/2022-2023:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 1.5 TR 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Carrier/Mistubishi)--
3OD244279/2022-2023:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 2 Tr 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Carrier/Mistubishi)--
4OD231476/2022-2023: Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 1 Tr 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Mitsubishi/carrier)--
5OD237101/2022-2023:Supply ,providing and fixing ISO wall panel (PUF panel) for covering indoor unit duct able split AC and return air box for ducting
6OD249068/2022-2023:Providing and fixing false ceiling at all height including providing and fixing of frame workmade of special sections, power pressed from M.S. sheets and galvanized with zinc coating of120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, oneflange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts& bolts of required size and other end of angle hanger fixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at everyjunction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered andsquare edges of the board with recommended jointing compound, jointing tapes, finishing withjointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also including the cost ofmaking openings for light fittings, grills, diffusers, cutouts made with frame of perimeterchannels suitably fixed, all complete as per drawings, specification and direction of theEngineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
7OD231468/2022-2023: Supply and providing stand/frame set for the outdoor unit on the wall with necessary screws etc: as required,
8OD244280/2022-2023:upply & drawing drain piping for the condensate drain water to the nearest drain point with 25 mm PVC pipe with nitrile rubber tube insulation.
9OD244281/2022-2023:Supply, fixing & giving connection of 4 KVA voltage stabilizer with voltage range of 175-275V and out put range of 210 - 240V suitable for 1.5 TR split type A/C unit
10OD244282/2022-2023:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent) -
11OD244283/2022-2023:Supply and providing the following size soft drawn copper pipe for connecting Indoor and Out Door unit using rubberized foam sleeve 10 mm thick, brazing, leak testing etc. 9 mm (3/8 inch) , 16 mm (5/8 inch) dia, 22g -
12OD244284/2022-2023:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.1/4\"(6.35mm) and 1/2\"(12.7mm) 22 gauge.--
131.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1490.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1590.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
1690.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1790.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1890.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
1990.6.5.20:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm
201.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
211.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
221.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
231.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
241.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
251.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2690.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
279.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
282.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
29OD250631/2022-2023:supply & installation of dust and vermin proof, wall mounting, Sintex SMC box of following size suitable for fixing 4 pole Isolator (GSJB 2014) or equivalent
302.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

AI Tender Summary

OUR REF NO 36590460
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-03-2023
Authority
Authority Name Public Works Department
Work Description Nabard-Infrastructure Work In Taluk Hospital ( Phase2 ) At Vaikom, Kottayam-Installation Ofadditional Split Air-Conditioner Unitsand Its Allied Electrical Works -Electrical Ac Work
Basic Detail
Tender No ESDK_ET_174_2022_2023
Bidding Type Tender
Location
City vaikom
State Kerala
Key Dates
Publish Date 03 Mar 2023
Submission Date 13 Mar 2023
Open Date 15 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 2120
EMD 23992
Exemption Not Available
Document List
fe1861fb-6a80-4306-97a1-8f089203718c.html
BOQ_830643.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf
viewnit.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 03, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 13, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 15, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

fe1861fb-6a80-4306-97a1-8f089203718c.html

xls

BOQ_830643.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

pdf

viewnit.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender