Tender For Repair To Summer Appliances And Certain Em Works Under Ge (West) Ferozepur Cantt, ferozepur-Punjab

Military Engineer Services-MES has published Tender For Repair To Summer Appliances And Certain Em Works Under Ge (West) Ferozepur Cantt. Submission Date for this Tender is 22-03-2023. Air Conditioner Tenders in ferozepur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36583377
Corrigendum : Tender For Repair To Summer Appliances And Certain Em Works Under Ge (West) Ferozepur Cantt
Open Tender
Indian
Punjab
ferozepur
22-03-2023

Tender Details

Repair To Summer Appliances And Certain Em Works Under Ge ( West ) Ferozepur Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work:REPAIR TO SUMMER APPLIANCES AND CERTAIN E/M WORKS UNDER GE (WEST) FEROZEPUR CANTT
Sl. No. Item Description
1WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any make including removed of all other unserviceableparts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , startingcapacitor, over load relay complete all as specified and directed
2Supply and Fixing company repaired compressor in lieu of defective compressor to water cooler of 150 Ltr/Hr cooling capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed
3All as per Srl No. 2 here-in-before but of cooling capacity 60 Ltr/Hr.
4All as per srl no. 2 here-in-before but of cooling capacity 40 Ltr/Hr.
5Supply and fixing new compressor to water cooler of 150 Ltr/Hr cooling capacity including,jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
6Supply and fixing new compressor to water cooler of60 Ltr/Hr cooling capacity including,jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
7Supply and fixing new compressor to water cooler of 40 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
8M & L for servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condersor coil withanti scaling solution complete all as specified and directed.
9Charging of water cooler with F-22/134a gas complete including replacement/filling of compressor oil of Make KAPILA "B" after leakage test and testingof water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as directed
10Repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
11Spray painting of water cooler of any make of capacity 150/120 ltrs with two coats synthetic enamelled paint of approved colour as approved by Engineer-in-Charge over a coat of red oxide primer complete including removing / scraping old paint, dust, preparation of surface, filling of metal putty and writing of MES No/ SM No of water cooler with Black paint complete all as specified as directed.
12Spray painting of water cooler of any make of capacity 80/40 ltrs with two coats synthetic enamelled paint of approved colour as approved by Engineer-in-Charge over a coat of red oxide primer complete including removing / scraping old paint, dust, preparation of surface, filling of metal putty and writing of MES No/ SM No of water cooler with Black paint complete all as specified as directed.
13Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing "E" class insulation material complete including replacement of unsv pad MS clamps, nut and bolt, varnishing & refixing the motor in the watercooler and testing of water cooler complete all as specified and directed.
14Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed
15Replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 ltr made out of GI Sheet complete all as per existing shape and size.
16Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specified as directed.Make – USHA/UNISTAR/TIBCON or equivalent.
17All as per srl item 16 here in before but Starting capacitor 80-100 MFD
18All as per srl item 16 here in before butOver load protector as per sample
19All as per srl item 16 here in before but Starting relay 1/8 HP as per sample
20All as per srl item 16 here in before but Plunger type relay as per sample
21All as per srl item 16 here in before but Thermostat switch for water cooler as per sample
22All as per srl item 16 here in before Push cock brass HD chromium plated
23All as per srl item 16 here in before but float valve ½” dia, brass with ball.
24All as per srl item 16 here in before but Rubber hose pipe/ for 1 ½” dia and 1.5 m longdrain pipe.
25All as per srl item 16 here in before but Over load/relay complete box type Y-412
26REFRIGIRATOR 310 LTR Taking outexisting compressor unit from the refrigerator of any capacity, of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
27Taking outexisting compressor unit from the deep freezerof any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
28Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected
29Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected
30Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 200/250 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected
31Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 300/400 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected
32Supply and fixing new compressor to refrigerator ofcapacity 310 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
33Supply and fixing new compressor to Deep freezer of capacity 320 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
34Supply and fixing new compressor to Deep freezer of capacity 250 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
35Charging of Deepfreezer/refrigerator with HC/R-12 gas of any sizeof any make complete including replacement of compressor oil of make capila "B" and testing complete all as specified and directed
36Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
37All as per srl item No 36 here in before butOver load protector 1/6 HP. Make Hitachi
38All as per srl item No 36 here in before butThermostat switch with knob - u-50-1018
39All as per srl item No 36 here in before butGlass cover heavy duty of Refrigeratorcapacity 310 ltrs
40All as per srl item No 36 here in before butFreezer door for whirlpool Refrigerator of Cap 310 ltr
41All as per srl item No 36 here in before but Butter box / any try any type and size as per sample complete suitable for whirlpool/Samsungrefrigarater of Cap 310 Ltr
42All as per srl item No 36 here in before butCrisper tray forany make and size Refrigerater as per sample
43All as per srl item No 36 here in before but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap 310 Ltr of any Make
44All as per srl item No 36 here in before but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap 165 Ltr of any Make
45Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
46Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motorcomplete all as specified and directed.
47AIR CONDITIONER WINDOW TYPE 1.5 TON CAP Dismantling/Taking out existing unserviceable window typeAir conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc complete all as specified and directed by Engineer-in-Charge.
48All as per Srl item No 47 here in before but split type AC of Cap 1.5 Ton.
49Supply and fixing company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specified and as directed
50Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specified and as directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
51Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary, copper tubing as required and testing the compressor complete all as specified and as directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
52Supply and fix in replacement of copper tubing for split type Air conmditioner of 3/8inch or nay size required at site all as specified and directed by Enge-in-chrage
53Charging of Air conditioner of capacity 1.5 TR with R-22 gas/as on site complete including replacement/ filling of compressor oil of make. Kapila "B" connecting lead tin coated thumble and installation of AC at site testing on full load for 24 hrs continuously complete all as specified and directed
54Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enameled copper winding wire of make. HTP/Devidayal after providing"E" class insulation material complete includingreplacement of unsv rubber pad MS clamp nut bolt varnishing and refixing themotor in the A/C and testing of Air conditioner complete all as specified and directed.
55Supply & fixing outer unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed
56Supply & fixing inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed
57Supply & fixing PCB unit of spilt type AC of exsting make complete all as specified and directed
58M&L for repair of existing UNSV PCB unit of spilt type AC of exsting make complete all as specified and directed
59Supply & fixing in replacement of condensor coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed
60Supply & fixing in replacement of condensor coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed
61Supply,fixing and connecting Running capacitor 36 MFD complete all as specified and directed
62All as per srl item No 61 here in before but Over Load protector No SR-1622 complete all as specified and directed
63All as per srl item No 61 here in before butStarting capacitor 100-120MFD.
64All as per srl item No 61 here in before butStarting Relay box type 1/8 HP SR-1622complete all as specified and directed
65Taking out existing unserviceable fan motor from the Air conditionor supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber padcomplete all as specified and directed.
66M & L for shifting of airconditioner split type of any make from its original position to another position including dismantling brick work/making hole in wall, 10mm thick plastering with cement mortar 1:4and 2 way DB with 32amp MCB requiredfor it complete all as specified and directed.
67M & L for shifting of air conditioner window type of anymake from its original position to another position including dismantling brick work/making hole in wall, 10mm thick plastering with cement mortar 1:4and 2 way DB with 32amp MCB requiredfor it complete all as specified and directed.
68DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
69Taking out existing unserviceable tulu pump (water pump) from the desert cooler supply and fixing connecting new tulu pump 1/20 HP 230 Volt 50 C/S single phase of Make - MIE/Khaitan all as specified and directed
70Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber padcomplete all as specified and directed.
71Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed.
72Replacement of Desert Cooler sides Shutters made of PGI sheet 20 gauge with pad sporting frame of size duly painted all as specified and directed. (Set of 3)
73Replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed
74Replacement of 3 wayPVC distributer
75Replacement of selector switch with knob
76Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specified.
77Taking out existing serviceable fan motor and tulu pump from the unsv body of desert cooler carefully and supply of complete desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump and testing complete all as specified and directed
78Painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and 0ut side complete all as specified and directed.
79Supply and fixing PVC pipe 15mm dia 3 mtr in each cooler
80Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed
81Replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler all as specified and directed.
82REPAIR TO VOLTAGE STABILIZER OF CAPACITY5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning "E" class insulator material varnishing and refixing complete all as specified.
83Dismantling of printed circuit board complex with condenser choke pre fixer and time delay relay and supply & fixing of new printed circuit board complete.
84Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj/Crompton/GEC
85REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning"E" class insulator material varnishing and refixing complete all as specified.
86Dismantling of printed circuit board complete with condenser dioel pre fixer of time delay relay. and supply & fixing of new printed circuit board complete.
87Supply and fixing Bakelite connector in main connection lead
88Supply and fixing indicator lamp Neon type (Green Red)
89Supply and fixing volt meter 0-300 volts single phase 230 volt make Bajaj/Crompton/GEC
90REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning "E" class insulator material varnishing and refixing complete all as specified
91Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj or equivalent standard.
92REPAIR TO VOLTAGE STABILIZER OF CAPACITY 1 KVA/ 0.5 KVA MAKE - INTEG ELECTRON/ RECOLD COMPRISING THE FOLLOWING Dismantling and opening of main transformer and taking out of old burnt winding wire and rewinding of main transformer with super enameled copper winding wire of make HTP/Devidyal afer provisioning "E" class insulator material, varnishing and refixing including replacement of high and low cut of voltage relay and refixing of time relay delay condenser and testing of voltage stabilizer on full load for 8 Hrs
93Supply and fixing indication lamp neon type (Red) complete all as specified and directed.
94Supply and fixing of push type switch complete all as specified and directed.
95Supply and fix Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA . Make: Microtek/Voltas or equivalent.
96Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
97Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
98M&L for replacment of UNSV existing reverse valve copper tubing as required on site for AC all as specified and directed.
99Servicing and reairing of Aqua Guard water purifier of any cap with following replacment of Make :- Aqua guard, Kent (a) Primery filter
100(b) UV light
101(c) CarbonCandle
102(d) Spun Candle
103(e) Long Spun Candle
104(f) Long CTO Candle
105(g) Mini CTO Candle
106(h) Booster Pump 100gpd
107(j) SMPS Power Supply
108(k) SV Copper
109(l) 100 GPD membrane
110(m) Carbon stone powder
111(n) Sensor of UV light
112(o)PVC pipe gripper at Primery filter ( set of two)
113(p) Replacement of solonide switch
114(q) PVCpipe of Aqua Guard as per exiting size
115(r) Primary filter case with clamps
116(s) Repairing of power circuit board
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy