}

Tender For Repair Maintenance Of Summer Appliances And Other Allied Works At Af Stn Memaura, Lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Summer Appliances And Other Allied Works At Af Stn Memaura. Submission Date for this Tender is 28-03-2023. Air Conditioner Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36581487
Corrigendum : Tender For Repair Maintenance Of Summer Appliances And Other Allied Works At Af Stn Memaura
Open Tender
Indian
Uttar Pradesh
Lucknow
28-03-2023

Tender Details

Tender For Repair Maintenance Of Summer Appliances And Other Allied Works At Af Stn Memaura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
INR 8 Lakhs /-

BOQ Items

Name of Work: Repair/maint of Summer appliences and other allied works at AFS Memaura.
Sl. No. Item Description
1Maintenance, servicing cleaning of window /split /Cassette type air conditioner 1.5/2.0/3.0 Ton capacity at site, cleaning of equipment by applyingblower to remove the complete dust, cleaning all the components with suitable cleaning agent, combing the condenser coil for betterefficiancy,checking the wiring, starting/running capacitor, staring relay, overload relay, thermostat switches condensor motor,blower motor,swing motor ,blower/condensor fan rectification of fault, connecting and testing on load.Replacement of spare or gas shall be measured and paid separately under respective item
2Dismantling / taking out unserviceable burnt sealed compressor unit 1.5/2.0 TR from air conditioner and fixing only hermetically sealed rotary type compressor unit of any capacity including necessary brazing the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer incharge Note: (i) Hermetically Sealedcompressor shall be measured and paid separately under supply only. (ii) The cost of Refrigerant gas is deemded to be included in quoted rate.
3Supply only hermetically sealed rotary type compressor unit of capacity 1.5 TR complete all as specified and directed.
4Supply only hermetically sealed rotary type compressor unit of capacity 2.0 TR complete all as specified and directed.
5Supply onlyFHP (Frictional Horse Power) motor of capacity 1/5 to 1/18 single phase 920 RMP with starting and running capacitor suitable for window type AC complete all as specified and directed.
6Supply only starting capacitor 80-120 MFD all as specified and directed
7Supply onlyrunning capacitor 36-60 MFD all as specified and directed
8supply and fix condenser fan motor capacitor of capacity 4.0 mfd / 6.0 mfd suitable for existing window type/ outdoor unit of split type air conditioner of capacity upto 2.0 TR complete all as specified and as directed.Make:Sarda/Unistar/Tibcon/Asian/Epcos.
9Supply only starting relay suitable for 1.0/1.5/2.0TR compressor all as specified and directed. ( Make: HI-tech/Classic or as per recommended by manufacture or equivalent as approved by GE.)
10Supply only condenser/cooling fan blade suitable for window type AC of any make & capacityall as specified and directed.
11Supply only of blower fan motor suitable for split AC of any capacity & make all as specified and directed.
12Taking down the unserviceable thermal insulating puf from the copper tubes, supply and fix and new thermal insulating puf for suction and discharge copper tubes of split type air conditioner of capacity upto 2.0 TR, neatly tying the ends with PVC insulation tape complete all as specified and directed.
13supply only new Remote and PCB sensor unit assembly suitable for existingmake of window / split type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed.
14Repair/Maintanence of Cuircuit board PCB suitable for existingmake of window / split type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed.
15Supply only indoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C and complete all as specified and directed.
16Supply only outdoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C and complete all as specified and directed.
17Supply only ML-1 contactor 240 volt, 25 Amp for split type AC 1.5/2.0 TR complete all as specified and directed
18Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for window / split type AC of capacity of 1.5 TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing on all as specified and directed. Note : The cost of refrigerant is deemed to be included in quoted rate.
19Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for window / split type AC of capacity of 2.0TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing on all as specified and directed. Note : The cost of refrigerant is deemed to be included in quoted rate.
20Supply only copper tube 3/4"" as per site requirement and all as directed
21Supply only copper tube 1/4"" as per site requirement and all as directed
22M & L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled back paint complete all as specified and directed.
23M&L for detecting leakage of refrigerant from cooling appliance by leakage test with provision of all T&P items as required at site and charging the refrigerant as required,making good leakage portion by brazing complete all as specified and directed. Note : The cost of Refrigerant as required on site will be Paid seperately.
24Material & labour for charging of R-22 refrigerant to the cooling appliancesall as specified and directed.
25Material & labour for charging of R-32A refrigerant to the cooling appliancesall as specified and directed.
26Material & labour for charging of R-410A refrigerant to the cooling appliancesall as specified and directed.
27Material & labour for charging of R-134A refrigerant to the cooling appliancesall as specified and directed.
28Pumping down the AC, taking carefully the indoor and outdoor units along with voltage stablizer of split type air conditioner of capacity upto 2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and shifting to another location where directed and installingthe indoor and outdoorunits alongwith stablizer at specified location and connecting all the electrical, suction and discharge lines, topping up the gas as required and testing on completion for proper function ing complete all as specified and directed.Note: Gas as required shall be measured under relevant item.
29Taking out old U/S voltage stabilizers of capacity 1 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, thesame shall be re-winded in the workshop of contractor as directed.
30S&F main relay 24 volts 25 Amps etc complete all as specified and directed.
31S&F main control circuit (PCB) etc all as specified and directed.
32S & F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
33S & F in replacement of MCB SP 06 to 32 Amps, "C" curve, 10 KA breaking capacity, 230 Volts & making connections by using suitable copper lugs complete all as specified and directed.
34Taking out unserviceable plug top of any description and supply and fix new plug top 3 pin 15 Amps single phase 230 volts complete all as specified and directed.Make: Legrand/Anchor/Cona/Havells.
35Taking out old unserviceable burnt sealed compressor from refrigerator/Deep freezer and fixing only new hermetically sealed complressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified and directed. Note: (i)Hermetically sealedcompressor shall be measured and paid separately under supply only item. (ii) The cost of Refrigerant gas is deemded to be included in quoted rate.
36Supply only hermetically sealed compressor suitable for refrigerator/Deep freezer of capacity upto 310 Ltrs.
37Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for Refrigerator/ Deepfridgerof capacity upto 310 Ltrs,as per existing model,including brazing the suction /discharge line and filling the suitable refrigerant gas.complete all as specified and directed. Note : The cost of refrigerant is deemed to be included in quoted rate.
38S&F in replacement of relay suitable for refrigerator/Deep freezer upto 310 Ltr capacityall as specified and directed.(Make: Indfos/Godrej/Whirlpool or equivalent)
39S&F in replacement of over load protector suitable for refrigerator/Deep freezer upto 310 ltr capacity all as specified and directed.( Make:Indfos/Godrej or equivalent.)
40S&F in replacement of thermostat suitable for refrigerator/Deep freezer upto 310 Ltr capacity (Make: Indfos/Godrej/Whirl Pool or equivalent )
41S & Fin replacement of Magnetic rubber door gasket suitable for refrigerator of any make & capacityall as specified and directed.
42Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 1.5Sqmm Copper conductor cable, heavy duty, 1100 Volts grade all as specified and as directed.
43All as per Ser item No.45 here-in-before but of size 3 core, 2.5 Sqmm complete all as specified and directed.
44S&F in replacement of fan motor suitable for deep freezer of any make and capacity complete inlcuding taking down existing unserviceable motor as directed
45Dismantling / taking out unserviceable burnt sealed unit of compressor from water coolers any make and capacity and fixing only hermetically sealed compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer incharge. Note: (i) Hermetically Sealed compressor shall be measured and paid separately under supply only.
46Supply only new sealed unit compressor suitable for water cooler 40/80 Ltr
47Supply only new sealed unit compressor suitable for water cooler 60/120 Ltr
48Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for water cooler of capacity upto 310 Ltrs,as per existing model,including brazing the suction /discharge line and filling the suitable refrigerant gas.complete all as specified and directed. Note : The cost of refrigerant is deemed to be included in quoted rate.
49Dismantling / taking out un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/8 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed.
50Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling, of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete
51S&F in replacement of starting capacitor 80-100 MFDall as specified and directed.
52S&F in replacement of Relay & OLP suitable for water cooler of any make & capacity complete all as specified and directed.
53S&F in replacement of thermostat switch suitable for water cooler complete all as specified and directed.
54S&F in repair Push tapssuitable for water cooler capacity up to 150 ltr etc complete all as specified and directed.
55S&F PVC flexible pipe heavy duty transparent 15mm/20mm dia (as per sample) etc complete all as specified and directed.
56S&F in repair ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed. (Weight min 142gms)
57S&F in replacement of running capacitor 4 MFD 230 volts 50 Hzs AC suitable for water cooler and desert cooler including taking out old capacitor complete all as specified and directed.
58M&L for painting of desert cooler"s of capcity 50 ltr external body, fan with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as directed
59S&F in replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with Gi wire for desert cooler of any make complete all as specified and directed.
60M&L for rewinding of stator of exhaust fan/kit fan 18" sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour all as specified.
61M & L for writing MES NO of window /split Type/cassette type AC with black painted minimum in 2 inch height 3 mm bold capital letter written with the synthetic enamel paint in pattern and style as specified and directed.
62M & L for writing MES NO of water cooler/ refrigerator / Deep freezer with black painted minimum in 2 inch height 3 mm bold capital letter written with the synthetic enamel paint in pattern and style as approved by the Engineer-in-chargecomplete all as specified and as directed
63Supply and fixing in replacement of submersible water lifting pump of capacity 1.25 m head, 230 Volts complete all as specified and directed.
64S&F in replacement of Kit fan motor 450 mm sweep 1350/1400 RPM.Complete all as specified and directed. ( Make: Everest/Summer Cool/Khaitan )
65Taking down old and unserviceable sub main wiring any size / type/ core including earth wire complete with batten /conduit etc and making good the disturbed surface to match the existing disturbed surface all as specified and directed .
66S&Fof submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmmcomplete drawn in PVC concealed rigid non-metallic conduit medium grade along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified.Note - (i)Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate. (ii) 2 runs of 4 sqmm wire and 01 run of earth wire to be measured as one run.
67Supply and fix 6 AC controller timer with tempreture based fully advanced LCD digital timer heavy duty,30-30-30-30 amps heavy duty relay output,time can be set I Hr to 12 Hrs as well you can set set tempreture based wall mounted,metallic body with powder coated,with isolated rugged power suplly,ISO 9001,CE certified and MSME Regd Co.complete all as specified and directed. Make : Dynamic Micro Tech,Model TT4-2018 or equivalent.
68Maintenance /Servicing /Cleaning /repair and testingof various indoor/outdoor parts for cassette type AC,3.0 Ton capacity,inverter type, 3 phase ,380-415 Volt,Gas- R410A,Make - Daikin having Model Number RR100LVVM6-E001347,cleaning of equipment by applyingblower to remove the complete dust, cleaning all the components with suitable cleaning agent, combing the condenser coil for better efficiancy checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load Note : Items required for replacement of worn out/Unserviceable parts will be measured and paid separately under respective items here-in-after.
69Supply onlyFan blade
70Supply only Indoor unit PCB assy Complete
71Supply only Outdoor unit PCB assy Complete including Noise filter & trasmission
72Supply only Outdoor Fan Motor with proper stand assembly
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail