Tender For Repair Maintenance Of Certain Summer Appliances Walking Cooler Mortuary Body Cabinet And Rep Repl Of Lt Panel Lt Cable Oh Lines At Bairagarh Under Ge Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Certain Summer Appliances Walking Cooler Mortuary Body Cabinet And Rep Repl Of Lt Panel Lt Cable Oh Lines At Bairagarh Under Ge Bhopal. Submission Date for this Tender is 01-04-2023. LT Cable Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36579764
Corrigendum : Tender For Repair Maintenance Of Certain Summer Appliances Walking Cooler Mortuary Body Cabinet And Rep Repl Of Lt Panel Lt Cable Oh Lines At Bairagarh Under Ge Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
01-04-2023

Tender Details

Tender For Repair Maintenance Of Certain Summer Appliances Walking Cooler Mortuary Body Cabinet And Rep Repl Of Lt Panel Lt Cable Oh Lines At Bairagarh Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-03-2023
2 27-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-04-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES, WALKING COOLER, MORTUARY BODY CABINET AT NEW MH AND REPAIR/ REPLACEMENT OF LT PANEL, LT CABLE, OH LINES AND ALLIED WORKS AT BAIRAGARH UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
2REPAIR AND MAINT OF LT PANELS, LT CABLES, OH LINES AND ALLIED WORKS AT BAIRAGARH BHOPAL
3Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out insoft/loose soil complete all as specified and directed.
4Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
5Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
6Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
7M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:- Compacted/punned thickness shall be measured & paid.
8Supplying and laying sub class "B" bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
9Dismantling cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete.
10Fixing only Cross arms, bracing, supports, clamps and back plate, obtained from demolition with & including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
11S&F Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
12M&L Earthing complete with GI strip as earth lead and MS galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32 x 6 mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40 x 3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame including plastering and white wash, charcoal, common salt 15cm at round the earth plate, watering pipe 20mm med grade/galvanized and 40mm dia GI pipe medium grade for GI strip protectionwith GI funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009. Notes: (i) The unit rate includes for 40mm diam medium grade protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured & paid seperately separately. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe, bends, elbow etc shall be deemed to be included in the unit rate.
13S&F Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed
14M&L for painting ofsteel pole (swan neck type or straight type) up to 9 mtr heightwith cross arms, clamp of any length and shape for LT overhead line/street light with two coats of aluminium paint after scratching out old paint, cleaning the existing surface rust free, preparation of the surface including marking pole numbers in a 20 cm dia yellow circle with number writing with blacksynthetic paint & painting strips in alternate from bottom to top with three strips of black syntheticpaint & two strips of white fluorescentpaint (up to 1.5 mtr height) throughout the circumference of pole ( width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole complete all as specified and directed.
15M&L for Painting the cross arms, clamps etcofLT PCCpoles of 9 Mtrs heightafter preparation of surface, making the surface smoothwith two coat of aluminium paint & providing alternative bend of 30 cm width ( 3 black and 2 white) from bottom of pole to 1.5 Mtr Height with two coat painting with synthetic enameled paint , writing of polenumbers in yellow circle 15 cm with black paint onpoles complete all as specified and directed.
16Supply, spreading and levelling 40 mm -80 mm size graded crushed coarse aggregate around transformer plinth/four pole and two pole structures all as specified and directed.
17M&L for Maint and cleaning of surrounding area of sub station near LT panels, transformer etc by cutting seasonal grass, bushes etc, by employing skilled mazdoor including using own T&P as required to do the job and taking all precaution while men on working in sub station being dange zone.
18Cutting & trimming tree branches along HT/LT over head lines after arranging shut down and by taking all precautions while working on lines, etc including all T & P required for the purpose and removal of rubbish complete all as specified and directed by Engineer-in-Charge. Note:- Number of trees & their branches cut under this item shall be entered in MB with location as “NOT TO BE ABSTRACTED”.
19M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
20M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed.
21M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed.
22M&L for tighteningand re stringing of existingACSR over head conductor of any size/type on LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and as directed. NOTE:- Each conductor to be measured seperatly
23Dismantling of ACSR conductor of any type and size complete all as specified and directed.
24S&Faluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete all as specified and directed.(Type of new conductors:- weasel/ rabbit/ Mink) Note : Measurements for the purpose of payments shall be made by measuring horinzontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.)
25S&F in replacemnt cradle guard hexagonal/rectangular, fabricated with galvanized steel wire 3.15mm dia complete all as specified and directed.
26S&F Steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC, numbering of poles in 100mm diameter yellow circle with black paint including 15 cm wide alternate black & yellow bands upto 1.5m height from ground level, type 410-SP-31 (9 meter long) including dismantling after disconnecting existing damaged LT PCC or steel poles, any length long and demolition of cement concrete complete. Note - Excavation, earth work and PCC shall be measured and paid separately.
27S&F MCCB, 630 Amp, 4 Pole, 50 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 500-630 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : L&T (d - sine) Cat No. CM94106OOT1OG or equivelent in Schinder/ Seimens as approved by GE.
28S&F MCCB, 400/320 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 250-320 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : L&T (d - sine) Cat No. CM98403OOQOOG or equivelent in Schinder/ Seimens as approved by GE.
29S&F MCCB, 250 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting, with thermal release range 200-250 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : L&T (d - sine) Cat No. CM92109OOP1OG or equivelent in Schinder/Seimens as approved by GE.
30S&F MCCB, 200 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting, with thermal release range 160-200 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : L&T (d - sine) Cat No. CM92109OON10G or equivelent in Schinder/Seimens as approved by GE.
31S&F MCCB, 160 Amp, 3 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting, with thermal release range 125-160 Amp including spreader terminals and phase barriersincluding taking down old unserviciable burnt MCCB, complete all as specified and directed. Make L&T (d - sine) Cat No. CM90638OOMO or equivelent in Schinder/ Seimens as approved by GE.
32S&F MCCB, 100 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 100-125 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : L&T (d - sine) Cat No. CM90642OOLO or equivelent in Schinder/ Seimens as approved by GE.
33Dismantling of LT insulator of any type any size complete all as specified and directed
34S&F Pin type, polymer insulator, 100mm height, 65 mm diameter for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, complete all as specified and directed.
35S&F Shackle type, polymer insulators 90mm diameter and 75mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 12mm diameter insulator bolts, washers & nuts complete all as specified and directed.
36M&L for servicing/ repairing of LT panel of any sizes,consisting of MCCB, bus bar ampere meter, volt meter,selector switch and phase indication neon lamp, all parts should be cleaning and removing the carbon, tighting the bolts, nuts and washer , lugs of cables, replacement of old rusted/damaged hardwares with new Galvanised bolts, nuts and washers,tapping/ insulating all exposed cables in LT panel with PVC insulation tape,as per site requirement completeall as directed by EIC.
37M&L for fixing MS slidinglocking doorbolt of size not less then 12 mm dia, 250 mm length bolt, stove enameled black with bright boltwith staple plateon LT panel doors (forlocking of doors) with min sixnuts, bolts and washersincluding drilling and fixing on site complete all as specified and directed.
38S&F Butt hinges, heavy weight, cold rolled mild steel, 100mm size duly welded to doors of LT panel board, etc complete all as specified and directed.
39S&F in repairs LED indication lamps (RGY) (set of three) complete all as specified and as directed.
40Supply, installation, test and commissioning of 3 Phasedigital electronic volt meterwith accuracyclass 1.0 , suitablefor LT 1.1KV panel flush pattern, square type (96 x96 mm) with built-in selector switch with making electrical connections including taking out old unserviciable voltmeter complete all as specified and directed. (Make : L&T Model Vega or equivelent in Seimens/ Schinder as approved by GE.)
41Supply, installation, test and commissioning of 3 Phasedigital electronic amper meter, 5A,with accuracyclass 1.0 , suitablefor LT 1.1KV panel flush pattern, square type (96 x96 mm) with built-in selector switch with making electrical connections including taking out old unserviciable amper meter complete all as specified and directed. (Make L&T Model Vega or equivelent in Seimens/ Schinder as approved by GE.)
42M&L in repair of LT cable straight through joint/ End joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size16 Sqmm to 35 Sqmmx 3.5 core complete all as specified and directed.
43M&L in repair of HT End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 95 Sqmmx 3 core complete all as specified and directed.
44M&L in repair of LT cable straight through joint/ End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size50 Sqmm to 95 Sqmmx 3.5 core complete all as specified and directed.
45M&L in repair of LT cable straight through joint/ End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size120 Sqmm to 185 Sqmmx 3.5 core complete all as specified and directed.
46M&L in repair of LT cable straight through joint/End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size240 Sqmm to 400 Sqmmx 3.5 core complete all as specified and directed.
47S&F in repairs LT line PVC spacers (Strip type) for the following complete all as specified and directed:-
48Spacers for two wire
49Spacers for three wire
50Spacers for four wire
51Spacers for five wire
52Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel striparmoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 10 Sqmm nominal cross section x 2 core complete all as specified and directed.
53All as per item No. 46.00 above but Size 16 Sqmm X 4 core complete all as specified and directed.
54All as per item No. 46.00 above but Size 25 Sqmm X 3.5 core complete all as specified and directed.
55All as per item No. 46.00 above but Size 35 Sqmm X 3.5 core complete all as specified and directed.
56All as per item No. 46.00 above but Size 50 Sqmm X 3.5 core complete all as specified and directed.
57All as per item No. 46.00 above but Size 70 Sqmm X 3.5 core complete all as specified and directed.
58All as per item No. 46.00 above but Size 95 Sqmm X 3.5 core complete all as specified and directed.
59All as per item No. 46.00 above but Size 120 Sqmm X 3.5 core complete all as specified and directed.
60All as per item No. 46.00 above but Size 150 Sqmm X 3.5 core complete all as specified and directed.
61All as per item No. 46.00 above but Size 185 Sqmm X 3.5 core complete all as specified and directed.
62All as per item No. 46.00 above but Size 240 Sqmm X 3.5 core complete all as specified and directed.
63All as per item No. 46.00 above but Size 300 Sqmm X 3.5 core complete all as specified and directed.
64S&F 40mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed.
65S&F 50mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed.
66S&F 80mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed.
67S&F 100mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed.
68S&F in repairs aluminium lugs of any type for the following complete all as specified and directed:-
6916 sqmm
7025 sqmm
7150 sqmm
7270 sqmm
7395 sqmm
74120 sqmm
75150 sqmm
76240 sqmm
77300 sqmm
78M&L for painting of extistingout door LTcubical panel from outer side with two coats of siemens grey paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface,complete all as specified and directed. ( Max size of LT cubical panel 1700 X1500 X 250 mm)
79M&L for Dismantling of overhead conductor of any size and type from any type of pole and lowering down safely (to avoid conductor to be damaged during tree cutting of tall branches or for replacement of pole) and refixing and tighteningand stringing of existing conductor after cutting of tree on pole with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and as directed. (each conductor to be measured seperatly, tree cutting to be paid seperately under relevent item).
80M&L for servicing/repairing of capacitor panel, any type and size upto 75 KVAR for making them functional, removing and cleaning of dusts, checking control wiring and connections, replacement of any damaged control wire, checking o capacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc, replacement of defective unserviceable parts to make the panel fuly functional complete all as specified and all as directed by Engineer-in-charge. NOTE:- Spares required shall be paid separately as supply only
81Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 15 KVAR complete all as specified and directed. [Make:-Legrand (Apican)/ Shreem / Neptune as approved by GE]
82Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 10 KVAR complete all as specified and directed. [Make:-Legrand (Apican)/ Shreem / Neptune as approved by GE]
83Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 5 KVAR complete all as specified and directed. [Make:-Legrand (Apican)/ Shreem / Neptune as approved by GE]
84Supply only power factor controller of 8 step controller, complete all as specified and directed. (Make : Legrand Cat part No. 415042 or equivalent inShreem/ Neptune as approved by GE.)
85Supply only MCB SP, 6 to 32 Amp, 240 V, 10 KA "C" curve,IP 20, Conf to IS, complete all as specified and directed.
86Supply only control coil 230 V suitable for4 Pole contactor, complete all as specified and directed. (Make : Legrand / Schinder/ seimens as approved by GE.)
87Supply only add on auxiliary contact block front mounting, 2 NO + 2 NC for4 Pole contactor 25 Amp, complete all as specified and directed. (Make : Legrand / Schinder/ seimens as approved by GE.)
88Supply , fabricating and fixing of LT panel door made up of CRCA sheet min3.15 mm thick duly painted with powder coated Siemens Grey paint, factory made, door of size suitable for existing LT panel and fixed , welded on site with panel body with havey duty hinges, with locking arrangement complete all as specified and directed.
89Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. Note:-GI pipe shall be measured & paidseparately under relevant items of this schedule.
90M&L for Painting of 33 KV MRS Bairagarh Power house Chainlink fencing including barber wire , Angle iron, (65 Mtr length X 65 Mtr width & 1.5 Mtrs height approx) including Main gate,after preparation of surface, making the surface smoothand applyingtwo coat of aluminium paint over a coat of red oxide primer from bottom of fencing upto top includingwhite wash of main gate pillar etc complete all as specified and directed.
91REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES AND CONNECTED WORKS UNDER AGE E/M BAIRAGARH
92WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any type and any make including removed of all other unserviceableparts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , startingcapacitor, over load relay complete all as specifid and directed.
93Supply and Fixing new company compressor of defective compressor to water cooler of 150 ltr capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed.
94All as per Srl No. 67 above but of capacity 60/120 Ltr. complete all as specifid and directed.
95All as per srl No. 67 above but of capacity 40/80 ltr. complete all as specifid and directed.
96M & L for servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condersor coil withanti scaling solution complete all as specified and directed.
97M&L for Charging of water cooler with R-22/134a gas complete including replacement/filling of compressor oil of Make KAPILA "B" after leakage test and testingof water cooler on full load for 24 hrs continuously at site of any type and any Make of capacity upto 150/150 ltr complete all as specifid and directed.
98M & L for shifting of airconditioner split type of any make from its original position to another position with andincluding any B & R work reqd and electric work requiredfor it complete all as specified and directed.
99M & L for shifting of air conditioner window type of anymake from its original position to another position with andincluding any B& R work and electric work requiredfor it complete all as specified and directed.
100Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing "E" class insulation material complete including replacement of unserviceable pad MS clamps, nut and bolt, varnishing & refixing the motor in the watercooler and testing of water cooler complete all as specified and directed.
101Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed.
102S&F in replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 ltr made out of GI Sheet complete all as per existing shape and size complete all as specified and directed
103Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specifid and directed.
104All as per srl item 77 above but Starting capacitor 80-100 MFD complete all as specifid and directed.
105All as per srl item 77 above butOver load protector as per sample complete all as specifid and directed.
106All as per srl item 77 above but Starting relay 1/8 HP as per sample complete all as specifid and directed.
107All as per srl item 77 above but Plunger type relay as per sample complete all as specifid and directed.
108All as per srl item 77 above but Thermostat switch for water cooler as per sample complete all as specifid and directed.
109All as per srl item 77 above but float valve 15mm/ ½” dia, brass with ball. complete all as specifid and directed.
110All as per srl item 77 above but Rubber hose pipe/ for 1 ½” dia and 1.5 m longdrain pipe. complete all as specifid and directed.
111All as per srl item 77 above but Over load/relay complete box type Y-412 complete all as specifid and directed.
112REFRIGIRATOR 310/165 LTR & DEEP FREEZER 300/400 LTR Taking outexisting compressor unit from the Refrigerator of any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
113Taking outexisting compressor unit from the deep freezerof any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
114Supply & Fixing only new compressor in lieu of defective compressor to refrigerator of 310/280/180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected.
115Supply & Fixing new compressor to deep freezer of 500 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected.
116Supply and fixing new compressor to Deep freezer of capacity 310 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment.
117Charging of Deepfreezer/refrigerator with R-22/R-32/R-134a gas of capacity 400/200/310/165 Ltr or any sizeof any make complete including replacement of compressor oil of make capila "B" and testing complete all as specified and directed.
118Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
119All as per srl item No 92 above butOver load protector 1/6 HP. Make Hitachi or other equvilent makes as approved by GE complete all as specified and directed.
120All as per srl item No 92 above butThermostat switch with knob - u-50-1018 complete all as specified and directed.
121All as per srl item No 92 above butFreezer door for whirlpool Refrigerator of Cap 310 ltr. complete all as specified and directed.
122All as per srl item No 92 above but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap 310 Ltr of any Make . complete all as specified and directed.
123All as per srl item No 92 above but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap180/190/165 Ltr of any Make. complete all as specified and directed.
124Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
125Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motorcomplete all as specified and directed.
126AIR CONDITIONER WINDOW & SPLIT TYPE 1.5 /2 TON CAPACITY Dismantling/Taking out existing unserviceable window typeAir conditioner of capacity 1.5/2 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc complete all as specified and directed.
127All as per Srl item No 100 above but split type AC of Cap 1.5 /2 Ton. complete all as specifid and directed.
128Supply and fixingNew compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton/2.0 capacity window AC including jointing compressor,capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specifid and directed.. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment.
129Supply and fixing New compressor in lieu of defective compressor to Air Conditioner split type of 1.5 Ton/2.0 capacity including jointing compressor,capillary, copper tubing as required and testing the compressor complete all as specifid and directed.
130Supply and fix in replacement of copper tubing for split type Air conmditioner of 3/8inch or any size required at site all as specified and directed.
131M&L for Charging of Air conditioner of capacity 1.5 TR/2.0TR with R-22 gas/as on site complete including replacement/ filling of compressor oil of make. Kapila "B" connecting lead tin coated thumble and installation of AC at site testing on full load for 24 hrs continuously complete all as specified and directed.
132Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enameled copper winding wire of make. HTP/Devidayal after providing"E" class insulation material complete includingreplacement of unsv rubber pad MS clamp nut bolt varnishing and refixing themotor in the A/C and testing of Air conditioner complete all as specified and directed.
133S&F in repairs switch piano type, 240 volts, singe pole, one ways, 5 Amps, fixed in desert coolers complete all as specified and as directed.
134S&F in repairs single pole and neutral enclosure with two pin and earth,plugand socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA andindustial plug top complete all as specified and directed. [MAKE:-Legrand (Cat no. 607841) or equivalent in Siemens/ Schinder/L&T/ ABB/Havells]
135Supply & fixing PCB unit of spilt type AC of exsting make complete all as specified and directed.
136M&L for repair of existing unserviceablePCB unit of spilt type AC of exsting make complete all as specified and directed.
137Supply & fixing in replacement of condensor coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed.
138Supply & fixing in replacement of condensor coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed
139Supply, fixing and connecting Running capacitor 36 MFD complete all as specified and directed.
140All as per srl item No 113 above but Over Load protector No SR-1622 complete all as specified and directed.
141All as per srl item No 113 above butStarting capacitor 100-120MFD.
142All as per srl item No 113 above butStarting Relay box type 1/8 HP SR-1622complete all as specified and directed.
143All as per srl item No 113above butFront show grill Made of Plastic complete including Air filter complete all as specifid and directed.
144DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
145Taking out existing unserviceable tulu pump (water pump) from the desert cooler supply and fixing connecting new tulu pump 1/20 HP 230 Volt 50 C/S single phase of Make - MIE/Khaitan complete all as specifid and directed.
146Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber padcomplete all as specified and directed.
147S&F in replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly spray paining complete all as specifid and directed.
148S&F in replacement of Desert Cooler sides Shutters set of 3 made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specifid and directed.
149S&F in replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed.
150S&F in replacement of 3 wayPVC distributer complete all as specifid and directed.
151S&F in replacement of selector switch with knob complete all as specifid and directed.
152Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specifid and directed.
153Taking out existing serviceable fan motor and tulu pump from the unserviceablebody of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly spray painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump and testing complete all as specified and directed.
154M&L for painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust/ complete removal of existing treatment and preparation of surface both inside and out side surfacing complete all as specified and directed.
155Supply and fixing PVC pipe 15mm dia 3 mtr in each cooler complete all as specifid and directed.
156Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed
157S&F in replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler complete all as specifid and directed.
158Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
159Repair/Maint of walk in cooler, mortuary body cabinate and misc items at New MH Bhopal Bairagarh
160M&L in replacementfor sub main wiring with PVC insulate unsheathed 2 x 4 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into PVC rigid conduit/casing caping on surface with 4 sqm PVC insulated green copper cable for continuos earth PVC pipe not less than 20 mm dia/width med gradewith all accessories complete
161M&L in replacement for sub main wiring with PVC insulate unsheathed 2 x 6 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into PVC rigid conduit/casing caping on surface with 6 sqm PVC insulated green copper cable for continuos earth PVC pipe not less than 20 mm dia/width med grade with all accessories complete
162Supply and fix in replacement sheet metal enclosures with socket plug top and MCB"s with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp.
163S&F sheet metal enclosure factory fabricated for Multiphase Out going suitable for Mounting MCCB as Incomer of rating 100 AmpVertical distribution board 4 way with suitable Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified. Cat No - DBVDD04160TAB -MCCB of HPL or Equivalent Model Havells/Legrand/ABB as Approved by GE. ( Note : MCCB & MCB Shall be Measured and Paid Separately )
164S&F for MCCB 100 Amp, 16 KA 3 Poleincluding complete electricalconnection by appropriate size of copper lugs complete all as specified and directed by the Engr-in-Charge.
165M&L for Repair/maint of UPS for 30 min back up three phase AC input 3 phase, 4 wire voltage range (V AC) 310 to 480 V, 55 HZ, phase out put 3 phase, 4 wire, battery voltage(V DC) 360 V, battery charging current 10A, operating tempeature (celcius) 0 to 45 degree C, operating port RS-232 server and client, IP20 of DSP based double conversion online system with True Galvanised isolation technology with out put power 8000W and out put voltage415 V ± 1% of capacity 7.5 to10. KVAincluding repair of mother board and spare parts if required of Make :- Su-Kam
166M&L for AMC for Aqua Guard of(quaterly basis) including servicing, repair, renewal/ replacement of all filters, defective spare partsif required complete all as specified and directed by Engr-in-Charge. .
167M&L for Periodical maintenance(Quarterlybasis)walk in cooler of size 8" x 8" x 8"for preserving life saving medicine and medical stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 1 TR/12000 BT U/Hr (one working and other standby)including repair of short circuit/damaged wiring , Servicing of Indoor/outdoor unit including gas charging complete. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shall quote the rate including oiling, greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately under relevant items as supply only.
168Supply only following broken/burnt out spare part ( only if required):-
169Compressor for outdoor unit no 1 Modle RUAHOP1514
170PCB Componant
171Blower fan heavy duty of size 450mm sweep or as per site requirement
172M&L for Periodical maintenance(Quarterlybasis)of walk in cooler of size 15" x 12" x 10"for preserving vegetable/meat stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 5 TR/60000 BT U/Hr (one working and other standby)including repair of short circuit/damaged wiring ,Servicing of Indoor/outdoor unit including gas charging complete. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shuold quote the rate including oiling,greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately as supply only.
173Supply only following broken/burnt out spare part ( only if required):-
174Compressor for outdoor unit no 1 Model RUAHO6024CS
175PCB Componant
176Blower fan heavy duty of size 650mm sweep or as per site requirement.
177M&L for Periodical maintenance(Quarterlybasis)of Mortuary cabinate for two body ,230 volt single phase, 50 hz with roof mounted refrigeration system of cp 6000 BTU/H, temperature range from 2 degree C to 6 degree C , complete with 1 piece stainless steel tray with handle including repair of short circuit/damaged wiring ,Servising of Indoor/outdoor unit including gas charging complete. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shuold quote the rate including oiling,greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately.
178Repair/Maintof Air Curtain with adjustable loures with electric motor single phase 230 volts AC, 50 hz with maximum velocity 10-11 Amps (1000mm width). Air speed 20M/S of Make Cecon modle No C1-042 including repair of short circuit/damaged wiring,servicing, repair/replacement of defective parts if required complete all as specified and directed.
179Removing the unserviceable compressor sealed unit of any make from water cooler capacity 60 / 120 liters after cutting copper tubing without any damage to existing parts and S & F for replacing new compressor with reconditioned compressor of same make with erection of compressor on base with suitable capillary, filter, etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing, etc including testing for smooth functioning complete all as specified and as directed..
180All as per BOQ serial item No. 146.00 above but for water cooler capacity 40/80 Ltrs complete all as specified and as directed.
181All as per BOQ serial item No. 146.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and as directed.
182M&L for removing the condenser fan motor from water cooler of 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
183All as per BOQ serial item No. 149.00 above but for water cooler capacity 60/120 Ltrs complete all as specified and as directed.
184All as per BOQ serial item No. 149.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and as directed.
185S&F in repairs Plastic fan blade suitable for water cooler of capacity 40/80 Litres complete all as specified and as directed.
186S&F in repairs Plastic fan blade suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and as directed.
187S&F in repairs Plastic fan blade suitable for water cooler of capacity 150/150 Litrs complete all as specified and as directed.
188S&F in repairs starting capacitor 2.5MFD, suitable for water cooler of any capacity complete all as specified and as directed. [Make:-EPCOS / USHA / ASIAN or equivalent as approved by GE]
189S&F in repairs running capacitor 2.5/10MFD suitable for water cooler of any capacity complete all as specified and as directed. [Make:-EPCOS / USHA / ASAIN or equivalent as approved by GE]
190S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and as directed. [Make: Danfoss / Indfoss or equivalent as approved by GE]
191M&L for servicing of Deep freezer of capacity 265 / 320 / 492 ltrs of any make, checking / testing all parts for its serviceability, oiling / greasing of condenser motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and as directed.
192Removing the unserviceable compressor sealed unit of Deep freezer of capacity 310 liters of any make and M&L for replacing the new compressor with reconditioned compressor of the same make of model complete re-installing in original position withal accessories like relay with over load protector & recharging of refrigerant complete including testing for smooth functioning complete all as specified and as directed.
193S&F in repair condensing coil suitable for Deep freezer of capacity 320 Liters complete all as specified and as directed.
194M&L for shifting of airconditioner split type of any make from its original position to another position with andincluding any B & R work reqd and electric work requiredfor it complete all as specified and directed.
195M&L for Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note:- (a)Sealed unit compressor shall be measured and paid separately as supply only (b)If any item required to made equipment functional like capillary tube, copper pipe, etc is deemed to be included in quoted unit rate.
196Taking out window/split type Air conditioner of any make and capacity from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
197Supply only New hermitically sealed / Rotary type compressor of Capacity 1.5 TR Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
198Supply only New hermitically sealed / Rotary type compressor of Capacity 2.0 TR Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
199Supply onlyFHP motor of capacity 1/5 to 1/18 HP, single phase, 920 RPM with starting and running capacitor suitable for window type AC. Make : AUE/Air master or equivalent as approved by GE.
200Supply only Starting capacitor 80-100 MFD /100-120 MFD /120-150 MFD. Make: Keltronor/Epcos as per recommanded by manufacturer or equivalent as approved by GE.
201Supply onlyRunning Capacitor 45/50 MFD. Make : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.
202Supply onlyStarting relay suitable for 1.0 /1.5 /2.0 TR compressorMake: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.
203Supply only Rotary/Push type selector switch suitable for 1.5/2.0 TR window type AC.
204Supply onlyThermostat suitable for window / Split type A/C Make : INDFOSS/Godrej or as per recommanded by manufacturer or equivalent as approved by GE.
205Supply onlyCondenser/cooling coil suitable for window/Split type AC 1.5 TR of any make & capacity.
206Supply onlyCondenser/cooling coil suitable for window/Split type AC 2 TR of any make & capacity.
207Supply only Blower fan Motor suitable for split AC /window AC of any capacity & make.
208M&L in repair of Remote PCB for a split type AC of any capacity & make.
209S&F in repair of Remote PCB for a split type AC of any capacity & make.
210M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing sizewith varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed.
211M&L for Charging of refrigerant gas R-22/R-32 in window / split type air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
212Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/MES store yard after repairing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
213M&L for cutting and removing unserviceable freezer unit of refrigerator capacity 165 / 170 / 175 litres of any make, and S&F new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and as directed.
214All as per BOQ serial item No. 180.00 above but for refrigerator capacity 286/300/310 Ltrs complete all as specified and as directed.
215S&F in repairs thermostat suitable for refrigerator 165 to 310 liters capacity complete all as specified and as directed. [Make: Danfoss / Indfoss or equivalent as approved by GE]
216M&L for finding out the leakage with the pressure test of the condenser or cooling coil ofRerigerator of capacity 286/310 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging thegas R-22/R-134 and testing the water cooler complete all as specified and as directed.
217All as per BOQ serial item No. 183.00 above but for refrigerator capacity 165/170/175 Ltrs complete all as specified and as directed.
218Removing the unserviceable compressor sealed unit of refrigerator of capacity 286 / 300 / 310 liters of any make and M&L for replacing the compressor with new compressor of same make & model complete, installing in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including testing for smooth functioning complete all as specified and as directed.
219All as per BOQ serial item No. 185.00 above but for refrigerator capacity 165/175 Ltrs complete all as specified and as directed.
220M&L for Charging of refrigerant gas R-134a for deep freezer /refrigerator/water cooler at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
221M&L for cleaning down complete body including fitting and fixtures of desert cooler of capacity 4000 / 5000 Cum per hours of any makeincluding removal of all sludges, loose paint dust, dirt, etc and preparing the surface for painting and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank including rewriting of MES No. etc complete all as specified and as directed.
222M&L for taking out fan motor single phase 230 Volts, 1400 RPM, 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and as directed.
223S&F in repairs desert cooler motor of three speed, ISI marked, 1400 RPM, single phase,copper winding motor with ring, side legs, necessary bolts and nuts of capacity 1/8 HP complete all as specified and as directed. [Make : Usha/ C&G/ Khaithan or equivalent as approved by GE]
224S&F body of 22 gauge suitable for coolers of capacity 18 Guage with water tank complete all as specified and as directed.
225S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 4000 Cum / hrs capacity desert cooler complete all as specified and as directed.
226S&F in repairs front grill / louvers to desert cooler made out from 0.8 mm thick GI sheet suitable for 5000 /4000 Cum / hrs capacity desert cooler of any make complete all as specified and as directed..
227S&F in repairs PVC flexible pipe 16 mm outer dia with bends for desert cooler complete with PVC elbow complete all as specified and as directed.
228S&F in repairs selector switches three way, 230 Volts single phase of standard quality fixed in desert coolers complete all as specified and as directed.
229S&F in repairs wood pad (Set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as specified and as directed.
230S&F in repairs sumbesable pump 230 Volts, 1/60 HP, ISI Marked for desert cooler including pump support plate fabricated with 0.4 mm thick GI sheet with fixing screws, nuts and bolts complete all as specified and as directed. [Make : Khaitan/Polar/GEC or equivalent as approved by GE]
231S&F in repairs capacitor 4 MFD for fan motor of desert cooler complete all as specified and as directed. [Make:-EPCOS / SYSCAP / ASIAN or equivalent as approved by GE]
232S&F in repairs iron fan blade powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and as directed.
233Deduct Schedule of credit (calculation will be done off line) Rs. 183191.00