Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #36579081

Tender For Sitc Of Lt Distribution & Protection System 1X60 Hp & 2X75 Hp At Motibagh Bps In R.K Puram Ac-44.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Mar 2023
0 days left
EMD
16800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Installation Testing And Commissioning Of Lt Distribution And Protection System At Sec-4 In R.K. Puram Ac-44. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipment’S Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminum. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire, Size 1500Mm X1800x375mm. Having Following Components Of Approved Make. , Mccb 415V, Four Pole High Breaking Capacity 50Ka 50Hz, 630Amp With Spreader & Handle - Make L&T / Siemens , Mccb 415V, Tp 3Phase High Breaking Capacity 36Ka 50Hz, 200Amp With Spreader& Handle - Make L&T / Siemens , Mcb Single Pole 6Amp. Make L&T / Havells , Mcb Triple Pole 63Amp. Make L&T / Havells , Mcb Triple Pole 32Amp. Make L&T / Havells , Over Load Relay 66-110Make: L&T / Siemens , Over Load Relay 6-10 Make: L&T / Siemens , Digital Amp. Meter Make Ae / L&T , Digital Volt Meter-Make Ae / L&T , Motor Protection Relay Make: L&T / Siemens , Power Contactor 220V 3Phase140amp. Make L&T / Siemens , Power Contactor 220V 3Phase110amp. Make L&T / Siemens , Power Contactor 220V 3Phase18amp. Make L&T / Siemens , Star Delta Timer On Delay Make: L&T / Siemens , Indicating Lights Led Type Ryb & On / Off. Make: L&T / Havells , Current Transformer 600 / 5, 200 / 5 , 30 / 5Make Ae / Advance , On Load Change Over Switch 400Amp. Open Execution Type Make:L&T , Supply Of Single Corecopper Cable. Make :Havells. , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares Complete In All Respect. , Loading, Unloading By Crane Or Heavy Labor And Cartage Up To Site Cleaning & Dressing The Surface Forinstallation Of The Panel At Site On Base Frame , Laying Of Cable , Termination Of Cable Both Incoming &Out Going Side , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow I ) Continuity And Earth Testing Ii ) Meagering Of All Equipment’S For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. Iii ) Checking For All Tightness Of Nut And Bolts Iv ) Alignments Of Doors Etc. Interlocking Tests. All Function Tests

BOQ

Name of Work: RSITC of LT Distribution & Protection System 1x60 HP & 2X75 HP at MotiBagh BPS in R.K Puram AC-44.
Sl. No. Item Description
1LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1500MM x1800x375mm. Having following components of approved make.
2MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,630Amp with spreader & Handle - Make L&T/Siemens
3MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,200Amp with spreader& Handle - Make L&T/Siemens
4MCB Single pole 6Amp. Make L&T/Havells
5MCB Triple pole 63Amp. Make L&T/Havells
6MCB Triple pole 32Amp. Make L&T/Havells
7Over load relay 66-110Make: L&T/siemens
8Over load relay 6-10 Make: L&T/siemens
9Digital Amp. Meter Make AE/L&T
10Digital Volt Meter-Make AE/L&T
11Motor protection Relay Make: L&T/Siemens
12Power contactor 220V 3phase140Amp. Make L&T/siemens
13Power contactor 220V 3phase110Amp. Make L&T/siemens
14Power contactor 220V 3phase18Amp. Make L&T/siemens
15Star delta timer on delay make: L&T/Siemens
16Indicating lights LED type RYB & On/OFF. Make: L&T /Havells
17Current Transformer 600/5,200/5 ,30/5Make AE /Advance
18On load change over switch 400Amp. Open execution type Make:L&T
19Supply of Single coreCopper Cable. Make :Havells.
20Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect.
21Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface forInstallation of the panel at site on base frame ,laying of cable ,termination of cable both incoming &out going side
22Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as followi) Continuity and earth testingii) Meagering of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth.iii)checking for all tightness of nut and bolts iv) Alignments of doors etc. Interlocking tests. All function tests

AI Tender Summary

OUR REF NO 36579081
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 07-03-2023
Authority
Authority Name Delhi Jal Board
Work Description Supply Installation Testing And Commissioning Of Lt Distribution And Protection System At Sec-4 In R.K. Puram Ac-44. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipment’S Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminum. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire, Size 1500Mm X1800x375mm. Having Following Components Of Approved Make. , Mccb 415V, Four Pole High Breaking Capacity 50Ka 50Hz, 630Amp With Spreader & Handle - Make L&T / Siemens , Mccb 415V, Tp 3Phase High Breaking Capacity 36Ka 50Hz, 200Amp With Spreader& Handle - Make L&T / Siemens , Mcb Single Pole 6Amp. Make L&T / Havells , Mcb Triple Pole 63Amp. Make L&T / Havells , Mcb Triple Pole 32Amp. Make L&T / Havells , Over Load Relay 66-110Make: L&T / Siemens , Over Load Relay 6-10 Make: L&T / Siemens , Digital Amp. Meter Make Ae / L&T , Digital Volt Meter-Make Ae / L&T , Motor Protection Relay Make: L&T / Siemens , Power Contactor 220V 3Phase140amp. Make L&T / Siemens , Power Contactor 220V 3Phase110amp. Make L&T / Siemens , Power Contactor 220V 3Phase18amp. Make L&T / Siemens , Star Delta Timer On Delay Make: L&T / Siemens , Indicating Lights Led Type Ryb & On / Off. Make: L&T / Havells , Current Transformer 600 / 5, 200 / 5 , 30 / 5Make Ae / Advance , On Load Change Over Switch 400Amp. Open Execution Type Make:L&T , Supply Of Single Corecopper Cable. Make :Havells. , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares Complete In All Respect. , Loading, Unloading By Crane Or Heavy Labor And Cartage Up To Site Cleaning & Dressing The Surface Forinstallation Of The Panel At Site On Base Frame , Laying Of Cable , Termination Of Cable Both Incoming &Out Going Side , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow I ) Continuity And Earth Testing Ii ) Meagering Of All Equipment’S For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. Iii ) Checking For All Tightness Of Nut And Bolts Iv ) Alignments Of Doors Etc. Interlocking Tests. All Function Tests
Basic Detail
Tender No NIT No. 31/EE(EM)M-10/(22-23)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 02 Mar 2023
Submission Date 07 Mar 2023
Open Date 07 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 16800
Exemption Not Available
Document List
0e9b7726-69bc-464d-b090-61fd3f2f645a.html
BOQ_309567.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 02, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 07, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 07, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0e9b7726-69bc-464d-b090-61fd3f2f645a.html

xls

BOQ_309567.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender