Government Medical College-GMC has published Supply Of Consumables, Reagents And Other Items-Transfusion Medicine. Submission Date for this Tender is 16-03-2023. Uniform Tenders in kollam Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | CONSUMABLES, REAGENTS & OTHER ITEMS |
2 | LANCET - ready to use manual blood lancet; Sharp point, all sides tapered provides quick, clean puncture ribbed surface for firm grip; Typical incision depth; approximately 2mm; Single use; Sterile individually packed; Chrome-polished stainless steel; Length, approximately 40mm,Width, approximately 6mm,Thickness, approximately 0.5mm |
3 | TOURNIQUET- Elastic Arm Tourniquet with Plastic Buckle; Should have a stretchy strap that helps in easy adjustment; Adjustable cuff size from 2 inch to 5 inch diameter; Should be comfortable for the blood donor |
4 | SPOT PLASTER - should provide coverage and protection of phlebotomy site; Should besterile andbreathable; Square or round shaped. |
5 | EXERCISE BALL - soft rubber ball; 10 cm diameter; adequate grip |
6 | STORAGE VIAL AUTOCLAVABLE SV 10 - 10ml vials plastic vials; should be autoclavable durable and long lasting |
7 | MICROTIP YELLOW 2-200MICROLITRE - microtip 2-200 microlitre compatible with multi channel pipette;even liquid dispensing and a good fit on the micropipette. Autoclavable; hydrophobic, medical grade polypropylene, free of lubricants, dyes and heavy metals;Tips with good seal on micro-pipettes; More transparency for clear visualization ; High clarity and finer tip orifice |
8 | VACUUM TUBES EDTA - vacuum polyproplene tubes with EDTA; transparent and see through 13x75 mm size. |
9 | VACUUM TUBES PLAIN -vacuum polyproplene tubes; transparent and see through 13x75 mm size. |
10 | VACUUM TUBES WITH GEL - Vacuum polyproplene tubes with gel activator; transparentand see through; 13x75 mm size. |
11 | TEST TUBE RACK SV 10 - should fit 10ml vials plastic autoclavable vials; durable and long lasting |
12 | TEST TUBE RACKS - should fit20 , 13* 75 mm test tubes; durable and long lasting. |
13 | FILTER PAPER KALPI - sheets should have 0.5 m width , available as rolls; should have good absorption |
14 | SLIDES FOR MICROSCOPY - Microscope Glass Slides 75 X 25 X 1.4 mm; scratch resisitant and clear; suitable for haema agglutination tests.-50/pkt |
15 | ACDSOLUTION A ANTICOAGULANT - 500 mLANTICOAGULANT CITRATE DEXTROSE SOLUTION(ACD) SOLUTION A; should be sterile and pyrogen free solution in a polyolefin bag or bottle; Should not contain antimicrobial and bacteriostatic reagents;The bag should be nontoxic and biologically inert; The bag-solution unit should beclosed system; The bag/ bottle should beoverwrapped to provide extra protection ; Each 100 mL should contain: (%w/v) Citric Acid, Monohydrate 0.8 g; Dextrose Monohydrate 2.45 g; Sodium Citrate Dihydrate 2.2 g; and Water for Injection. |
16 | 3 CELL PANEL SCREENING CELLS - 3-cell screening for patients; should contains a set of 3 vials , 10 ml each for IAT and NaCl testing; should include two RhD positive cells (CCDee, Cw+, ccDEE) and one cell RhD negative (cc.ee) with Configuration: R1WR1, R2R2, rr; should include double dose for Fya, Fyb, Jka, Jkb, M, S and s, and at least one cell positive for K, Lea, Leb, P1 and N; Should betested by serology for HLA Class I antigens; Should have a stability of 7 weeks ; Should be supplied on standing order every 4 weeks; Should be compatible with CAT used in matrix centrifuge. |
17 | 11 CELL PANEL CELLS - a set of 11 (4 mL) vials for IAT and NaCl testing; Should have afixed Rh phenotype pattern and assured presence of cells possessing double-dose antigens throughout representing the common asian /indian blood group antigens; Should betested by serology for HLA Class I antigens; Shouldhave a stability of 7 weeks; Should be supplied on standing order every 4 weeks;Should be compatible with CAT used in matrix centrifuge. |
18 | ANTI H ANTISERA - Ready to use purified lectin extract of Ulex europaeus seeds; optically clear ; Titre: ~ 1:16 with O group cells; Specificity: Negative reacting with "O "phenotype h; Reactivity:Graded reactivity with different red cells,O>A >A B>B>A >A B ; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; Stability of1 year-5ml/pack |
19 | ANTI A1 ANTISERA - Ready to use purified lectin (phytohemagglutinin) extract of Dolichos biflorus seeds; Optically clear solution; Should have titre of 1 ~ 1:16 with A1cells and1 ~ 1:16 with A1B cells; specificity of A1 antigen shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; sta-bility of2 year.-5ml/pack |
20 | ANTI D IgG - should have aTitreupto 512 dilution by two fold serial dilution in tubes; Thereagent should bespecific for the purpose or not with Rh negative cells as it should not sensitize Rh negative cells; Should eliminate prozone phenomenon with strongly sensitized cells in DAT; should Eliminate negative reaction with weakly sensitized cells in DAT; Stableat 2-8ºC with shelf life of 2 years; Sodium azide is added to the antibodies at 0.1% concentration as preservative-10ml/pack |
21 | ANTI D (IgG+ IgM) - should contain Anti-D (IgM + IgG) Monoclonal Antibodies; should agglutinate in saline solution;Should be Active at room temperature and 37°C; Usable on glass slide as well as in the tube; Should have a shelf life of 2 years at 2-8 degree C; should have an avidity of 5-10 sec; Igm titre should be 1/256 and IgG 1/8; 10ml/pack |
22 | PAPPAIN - Stabilized ready to use papain reagent (liquid state); standardised as per AABB and FDA guidelines; Should have thiol reducing agent; stable for 2 years at 2-8degree C; Can be used in CAT compatible with matrix centrifuge-5ml/pack |
23 | BOVINE ALBUMIN (10ml)- 22% Purified Bovine Serum Albumin; pH 7.1 (± 0.2%) ; Globulin free should give single band on gel electrophoresis; Standardized as perAABB and FDA guidelines; optimum concentration of stabilisers. Stable at 2-8degree C for 2 years.-10ml/pack |
24 | ANTI C - Ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dCe/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dcE/dce) phenotype;100%Specificity to C antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines; 10ml vial |
25 | ANTI c - Ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dCe/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dcE/dce) phenotype;100%Specificity to c antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines.-2ml/pack |
26 | ANTI E - Ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dCe/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dcE/dce) phenotype;100%Specificity to E antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines--2ml/pack |
27 | ANTI e - Ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dCe/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dcE/dce) phenotype;100%Specificity to e antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines--2ml/packl |
28 | ANTI LEWIS A - 100% specificity to Anti Le a antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines--2ml/pack |
29 | ANTI DUFFY A - 100% specificity to duffy a Antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines--2ml/pack |
30 | ANTI M - 100% specificity to M antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines--2ml/pack |
31 | MONOSPECIFIC GEL CARDS - should havemicrotubes pre-filled with gel in a suitable buffer containing monospecific Anti-IgG antibodies; Should rule out anti complement activity in AHG tests performed; Card should be Photocopiable ; Shelf life of 1 year; Standardised as per FDA guidelines; Should be compatible with matrix centrifuge. |
32 | ELUTION KIT FOR AIHA - Should identifyantibodies from sensitized red cells ; ready-to-use reagents for the acid elution of most common antibodies; Should havestability;Color change to indicate end of reaction phase . |
33 | FORWARD &REVERSE ABO GROUPING CARD - Forward and Reverse CAT with Grouping Card with Autocontrol; should contain monoclonal Anti-A, Anti-B and Anti-D (IgM) (VI-)a negative control andneutral gel used for reverse grouping; Card should be Photocopiable ; Shelf life of 1 year; should be one profile/card; Standardised as per AABB guidelines; Should be compatible with matrix centrifuge.; 24/pack |
34 | RH KELL GROUPING CARDS - Forward and Reverse CAT with Grouping Card with Autocontrol; should contain monoclonal Anti-A, Anti-B and Anti-D (IgM) (VI-)a negative control andneutral gel used for reverse grouping; Card should be Photocopiable ; Shelf life of 1 year; should be one profile/card; Standardised as per AABB guidelines; Should be compatible with matrix centrifuge;24/pack |
35 | RH VIEW BOX - should have soft fluorescent, glare-free light that provides excellent uniform slide illumination; 230 V,50 hz; temperature indicator required; compact and light weight; |
36 | HAEMOGLOBINOMETER - portable hand held analyser; Light weight less than 250 gm for transportation to camp site ; interpretable results within 10 seconds; Cuvettes should be reagent free; Should have battery back up; Should have an option for software installation for easy data transmission; Should have two charging possibilities- USB and adaptor; Should be robust for mobile use; Should have minimal maintainenance and cleaning; Should have option for barcode scans. |
37 | Anti N-100% specificity toN antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; Standardised as per AABB and FDA guidelines; 2ml/pack |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail