}

Tender For Rate Assessment Study For Electro Mechanical Components Of Fstp Under Dmc, Under Dmc Area. (Only For Assessment Of Rates Of Non Schedule Items), durgapur-West Bengal

Urban Local Bodies has published Tender For Rate Assessment Study For Electro Mechanical Components Of Fstp Under Dmc, Under Dmc Area. (Only For Assessment Of Rates Of Non Schedule Items). Submission Date for this Tender is 05-04-2023. Prime Mover Tenders in durgapur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

36569276
Corrigendum : Tender For Rate Assessment Study For Electro Mechanical Components Of Fstp Under Dmc, Under Dmc Area. (Only For Assessment Of Rates Of Non Schedule Items)
Open Tender
Indian
West Bengal
Durgapur
05-04-2023

Tender Details

Rate Assessment Study For Electro Mechanical Components Of Fstp Under Dmc, Under Dmc Area. ( Only For Assessment Of Rates Of Non Schedule Items- 1 Supply, Installation Testing & Commissioning Of 1M3 / Hr, , 10 Mt.Capacity Horizontal, Centrifugal Non-Clog Open Impeller Self Priming Pump With Eff-1 Squirrel Case Induction Motor Tefc, Ip55 Flexibly Coupled With Accessories Like, Mabt / Fabt, Flexible Coupling With Surid, Nrv, Comon Base Frame Complete In All Respect & As Per Direction Of Eic. Mk: Pump:- Kirloskar / Ksb / Mbh Motor :- Abb / Marathon / Cr. Greaves 2 Supply, Installation Testing & Commissioning Of Primary Lamella Clarifier / Ips For Maxmium Flow Of 2810 Lt / Hr. With Retention Time At Max Flow Is 18 Minute As Per Technical Specification & Direction Of Eic.Flash Mixture Tank Vol. 70-120 Lit. Floculation Tank Vol. -78Lit.Pre Treatment Vol. -95-98 Lit.Effluent Pipe Connection- 2, 150 Flange Solid Discharge Connection - 2:, 150 Flange Sludge Capacity - 158.76 Lit.Plate Are- 3.62 M2liq Volume - 669.06 Lit.Retention Time On Max Flow -18 Minute Solid Removal 95+%@220 Ppm Influent Under Flow Solids-1-2% Moc - Under Lining Frp 3 Introduction Of Areation System By Using Fine Bubble Diffusers. The Air Quantity Required Shall Be Suitable To Provide Sufficient Oxygen For Aerobic Bio Degradtion Of The Inlet Organic Matter. Capacity To Handle 30Kld & 50 Kld As Per Technical Specification & Direction Of Eic. ( Mbbr-1&2 ) Min.Hrt- 3 To 4 Hrs.Free Board -0.5M 4 Supply, Installation Testing & Commissioning Of Secondary Lamella Clarifier Suitable To Handle 30Kld As Per Technical Specification & Direction Of Eic & Ready For Hocl Dozing. 5 Introduction Of Holding Sump Ms Epoxy With Underlining Frp Coating For Ozonization. 6 Supply, Installation Testing & Commissioning Of 2M3 / Hr. With Suitable Head, Centrifugal Mono-Block Filter Feed Pump. 7 Introuction Of Multi-Grade Filter Frp / Ms Epoxy With Graded Media 8 Introduction Of Activated Carbon Filter With Frp / Ms Epoxy With Carbon Media. 9 Supply, Installation Testing & Commissioning Of 10-20 M3 / Hr. Twin Lobe Air Blower With 0.3 Kg / Sq.Cm Pressure With Prime Mover Complate. Mk: Airvak / Akash / Kay / Everest 10 Supply, Installation Testing & Commissioning Of Ozonator Unit With A Dosing Capacity 5 Gm.Mk:- Oraipl / Equiv. 11 Supply, Installation Testing & Commissioning Of Dozing Pump One Working & One Stand By Capacity 0-4 Liter / Hour. Handling Liquid Hocl As Per Direction Of Eic. 12 Supply & Installation Of Dosing Tank Of Capacity 100 Ltr. Moc-To Fit With The System. 13 Supply Of Clear Water Collection Tank Suitable To Handle 52M3 / Day Moc-Sintex / Equiv. 14 Supply, Installation Testing & Commissioning Of Level Controller Unit As Per Technical Specification & Direction Of Etc. P. Supply- 230V Ac, Panel Mounted Ip-68 Protection, Handling Length Minimum 5 Mtr.Mk:- Siemens / Equivalent. 15 Supply, Installation Testing & Commissioning Of Control Panel Dust & Varmin Proof Wall Mounted With Ammeter, Voltmeter, Incoming Feder, Outgoing Feeders, Indicating Lamps Etc. 125 A Minimum Rating Complete In All Respect. L&T / Siemens / Selwin / Rnr 16 Illumination Of Plant Area With Suitable Led Fixture & Pole &Plant Building With Decorative Tubelight Fittings Including All Point Wiring & Cable Laying Termination Etc. Complete Including Supply Of Exhaust Fan & Wall Mounted Cabin Fan / Ceiling Fan As Per Direction Of Eic. 17 Inter Connection Of The Units With Necesary Piping, Valves Of Upvc / Ms / Pvc Material & Hdpe Of Approved Make Suitable Grade 63 / 80 / 100 For 6 Kg / Sq.Cm Pressure As Per Technical Specifaction & Direction Of Eic. 18 Trail Run & Commissioning Of The System As Per Direction Of Eic. 19 Operation & Maintenance Cost Including Consumables As Per Direction Of Eic For 5 Years.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-04-2023 Due Date Extended - Due to some issues in accessing portals, all the tenders due for closing on 05-April-2023 have been extended by 24 hours as per System Malfunction Procedure. Admin Corrigendum Date Extend 06-04-2023
2 18-03-2023 Due Date Extended.18Mar2023 Admin Corrigendum Date Extend 20-03-2023
3 21-03-2023 Date Extension Date 28-03-2023
4 29-03-2023 Extension Date Date 05-04-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail