Housing Urban and Rular Development Government Departments Closing in 0 days TDR #36560691

Tender For Construction Of Health Sub Centre Jagarnathpur, Block- Narayanpur, District- Jamtara For The Year 2022- 23

Issued by Government Departments · jamtara, Jharkhand
Tender Value
55.48 Lakhs
Estimated cost
Bid Submission
11 Mar 2023
0 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jamtara → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Health Sub Centre Jagarnathpur, Block- Narayanpur, District- Jamtara For The Year 2022- 23

BOQ

Name of Work: Construction of Health Sub Centre Jagarnathpur, Block- Narayanpur, District- Jamtara for the year 2022- 23
Sl. No. Item Description
1EARTH WORK INEXCAVATION IN FOUNDATION Trenches in all kinds of OrdinarySoil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
2Extra for earth work in hard soil as per specification & dirction of E/I. (Vide classification of soil item B)
3Earthfilling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
4Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5Providing coarse clean lical sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with leads and 1.5 in
6Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building spedification and diection of E/I.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finshing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement :1.5 coarse sand (Zone-III): 3 graded stone aggregate 20mm nominal size)
10Reinforce cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, post and struts etc. Above plinth level up to floor five leve, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-III) :3 graded stone aggregate 20mm nimonal size)
11Reinforced cement concrete owrk in beams, suspended floors, roofs having slope up to 150 landing, balconies, shelves, chajjars, lintels, bands, plain window sills, staicases and spiral stair cases above plinth level up to floor five level, excluding the cost of centeri, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-III): 3 graded stone aggreagte 20 mm nominal)
12Providing Tor steel reinforcement of 8 mm, 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. {only valid for TATA (Tiscon), SAIL, JSPL, Electrosteels Ltd. Bokaro and Vizag (RINL)}
138 mm dia
1410 mm dia
1512 mm to 20 mmdia
16Centering and shuttering including struting, propping etc and removal of form for
17foundation, footings, bases for columns, etc. For mass concrete
18Suspended floors, roof, landings, balconies and access platform.
19Lintels, beams, Plinth Beams, girders, Bressumers and cantilevers
20Columns, Pillars, Piers, Abutment, Post and struts
21Providing designation 75B brick work in CM (1:6) in foundation and pling with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per buildding specification and direction of E/I.
22Providing designation 100A B/W with Fly Ash Brick (FALB) conforming to IS 12894-1990 (9\"x4.5\"x3\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints cost of screening, raking out joints to 15mm depth, curing, taxes sand royalty all complete as per building specification and direction of E/I.
23Providing designation 112mm thick reinforced designation 100A B/W with Fly Ash Brick (FALB) conforming to IS 12894-1990 (9\"x4.5\"x3\") in cement mortar (1:6) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including of screening, carriage of materials, scaffolding,raking out joints to 15mm depth, curing, taxes sand royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
24Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
25Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc.complete :Kiln seasoned and chemically treated hollock wood50x20 mm
26Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge.
27Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel.10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading
28Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
29Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(i) Single rubber stopper
30Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having band logo with ISI, IS:3564, embossed on the dody,, door weight upto 36kg to 80 kg and door width from 701mm to 1000mm with double speed adustment with necessary accessories and screws etc. complete.
31Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
32Providing and fixing pressed steel door frames conforming to IS:4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by E/I.
33Supplying, fitting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/i.
34Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20x10x2mm at 10mm centers and braced with M.S. flat diagonals 20x3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
35Providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO: 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1:4 9(1 cement: 4 coarse sand) jointing with grey cement [email protected]/sqm including grouting the joints with white cement and matching pigments etc., complete sise of tile 600x600mm
36Providing and fixing granite 18mm thick gang saw cut, mirror polished, premoulded and prpolished, machine cut for flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of requied size, approved shade, colour and txture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
37Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With \"A\" grade white 15X15cm Tiles.
38Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as white, lvory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement [email protected]/sqm including pointing the joints with white cement and matching pigment etc. complete.
39Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(iv) 600X600 mm size
40Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
41Providing single layer Naria-tiles in roof including cost of all labour and materials, taxes, all complete as per building specification and direction of E/I.
42Providing gola 75x75mm in cement concrete 1:2:4 (1 cement: 2coarse sand : 4 stone aggregate 10mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design:
43Water proofing for Old and New Roof Slab :- Providng and laying water proofing treatment on roof slab by applying tow component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofing coating as per manufacturer specification-With following steps:-(a) Suface preparation:- Providing and cleaning of concrete surface to remove dust, iol, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools, complete. Ponding test to be done after pugging all outlets and to be cheded from soffit to identify seepage, ladkage. On indentification of seepage, cement grouting to be done with non shirnk expanding admixture of Sika India Pvt. Ltd. / MYK Schombeg/Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints usch as those between the parapet wall and the roof slab etc. Shall be chamfered with \"150mmX\"150mm fillet lf mortar (Cement sand- 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or requivalent Before chamfering a prime coat shall be give with the slurry of acrylic polymer Reparing surface irregularities, damaged concretein base slab, dead cracks if any, with and acrylic polymer modified reqpair mortar including a coat of bonding agent of the same with cement slurry including all materials labour, tools, complete.(b) 1st Coat :- Apply 1st coat of two component acrylic modidied, ready to use, flexible cementitious material on surface saturated dry roof and inisde wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm oil Fibre glass cloth to lay when the fist layer is still greeb. 1st ciat sgiykd ve aookued @1.50/kg/sqmt/coat for the purpose of measurement the entire treated surface will be measured.\"(c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use flexible cementitious materials right angle to the \"1st coat over the glass fibre laid surface. 2nd coat should be applied@ 0.7kg/sqmt/coat. For the purpose lf measurment the entire treated surface will be measured.\" alter three days of drying the 2nd coat, the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, teakage from soffit and if found necessary rectification to e be done as per satisfation of E/I. The Watqrproofing Brand: *Sika Topseal 109hi/Fosroc Brushbond RFX/ Dr Fixit Pidiffine 2KI MYK Aqraiin TG Product Performance- Chemical Base Part A.Acrylic copol,mer, Part 13 Specially graded cementitious powder-Density 1.6 kg/l (mixed density) at +270 Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.) 4624) Slant-shear Bond Strength-4 N/mm2 (According to FIP 5.15) Flongation at Break- 35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTMD 2370)D Protection of treated with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in altematepanels lf 2mtx2mt keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS2645@ of 100 ml perbag of cement tobe added in the screed concrete (paid separately for this items) all corners shal be charfered with 150mmx150mm fillet. The rain water outlets shal be just leveled with the scree concrete to ensure smooth descharge of water- the perpheral gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensisive epoxy putty of Sika India Pvt.Ltd./IVIYK Schomberg/Dr Fixit / Fosroc. For the purpose of measurement the entire treated surface will be meaured.\"
44Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc. Warranty for five years.
45Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I
46Providing 6mm thick cement plaster (1:4) in ceilling with clean coarse sand of F.M. 1.5 including cost of carriage, screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
47Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
48Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
49Providing tow coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolidng washing of floors and taxes all complete as per building specification and direction of E/I.
50Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
51Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
52Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
53Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominla size) over 75mm thick bed of dry brick ballast 40mm nominal size, wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing all complete as per specification and direction of E/I.
54Providing and fixing circular/hexagonal cast iron of M.S. Sheet box for ceilling foa clamp, of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. Sheet with its top surface hacked for prper bonding, top lid shall be screwed into the coat iron/M.S sheet box by means of 3.3nn dua riybd geaded screwsm ibe kicj at tge cormers, Clamp shall be made lf 12mm dia M.S. bar bent to shape as per standard drwaing.
55Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
56Carriage of Materials from quarry site to work site.
57Bricks
58Fly Ash Bricks
59Sand
60Stone chips
61Local Sand
62Providing 12 mm Thk. cement plaster(1:3)with punning with clean course sand of FM-1.5including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I
63Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
64Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
65Supplying materials and labours for construction of I.C. of size 750mm deep, 600 × 450 internal dimension …do…. all complete as per specification and direction of E/I.
66Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.Group C
67Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
68Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
692x1.5sq mm + 1x1.5 sq mm earth wire
702x2.5sq mm + 1x2.5 sq mm earth wire (1.7.2)
714x2.5sq mm + 2x2.5 sq mm earth wire (1.7.8)
724x10 sq mm + 2x6 sq mm earth wire. (1.7.11)
73Supplyinganddrawingco-axialTVcableRG-6grade,0.7mmsolid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required.
74Supplying andfixing offollowing sizes ofPVCconduit alongwith the accessoriesinsurface/recessincludingcuttingthewallandmaking good the same in case of recessed conduit as required.
7520 mm dia
7625 mm dia
77Supplyingandfixingfollowingmodularswitch/socketontheexisting modular plate & switch box including connections but excluding modular plate etc. as required.
785/6 amps one way switch
7915/16 amp one way switch
805/6 amp 3 pin socket outlet
815/16 amp 6 pin socket outlet
82TV anteena Socket Outlet
83Supplyingandfixingsteppedtypeelectronicfanregulatoronthe existing modular plate switch box including connections but excludingmodular plate etc. as required.
84Supplyingandfixingmodularblankingplateontheexistingmodular plate & switch box excluding modular plate as required.
85(Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
861 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
874/5 Module (78mm x140mm x 50mm)
886 Module (78mmX205mmx50mm)
89Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
90Supplyingandfixingbrassbatten/angleholderincludingconnection etc. as required.
91Supplying and fixing Dingdong sound call bell single phase, 230 volts, complete as required.
92Installation of exhaust fan up 450 mm sweep in the existing openingincludingmakingtheholetosuitthesizeofabovethefan, making good the damage, connection, testing, commissioning etc. as
93Supplyingandfixing20amps,240volts,SPNindustrialtype,socket outlet,with2poleandearth,metalenclosedplugtopalongwith20 amps“C” curve,SP, MCB,in sheetsteelenclosure,onsurfaceor in recess,withchainedmetalcoverforthesocketoutletandcomplete with connections, testing and commissioning etc. as required. (JSR-2.18)
94Supplyingandfixingfollowingways,horizontaltypethreepoleand neutral,sheetsteel,MCBdistributionboard,415volts,on surface/recess, completewith tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door Horizontal Type
95Supplyingandfixing6Ampto32Amprating240volts,10KA \"C\" CurveMiniature Circuit Breaker suitable for inductive loads of followingpolesintheexistingMCBDBcompletewithconnections, testing and commissioning etc.,as required.
966 / 32 Amp Single Pole
9740 Amp TPN
98Supplying and fixingSingle pole blanking plate in the existing MCB DBcomplete etc. as required.
99Supplyingandfixingoffollowingratingdoublepole(Singlepole& neutral),240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 40 Amps (2.16.2)
100Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
101Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
102Providingandfixing6SWGdiaG.I.wireonsurfaceorinrecessfor loopearthingalongwithexistingsurface/recessedconduit/submain wiring/ cable as required.
103Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming toIS-7098. (Part-I).4 core,16 sq.mm.
104S.I.T.C offollowing ratingreccess/ surface mountedLED round/ square shape down light luminarie with pressure die cast housing for single phase Supply voltage. Luminarie shall be confirm to IS: 10322 part- 5/ Section- 2 or IEC: 62722 with all neccessary accessories as required. 18 /20 W LED Round Down Light (Surface)
105Bulk Head fitting with 9/10 Watt. LED
106S.I.T.C offollowing ratingsurface mountedLEDTubeLighting Fitting Suitablefor230V50Hz,SinglePhaseSupplyetc.completeas required.
10710/12 W LED Tube Light
10840 Amp TPN20/22 W LED Tube Light
109SITCof 300mm(12\")Exhaustfan(Metalbody)suitableforsingle phase230volts,50Hz.,ACsupplycompletewithmotor, louvers/shutters etc. complete as required.Make :- Usha/Crompton / Havells .
110Supply installation, testing and commissioning of follwing size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm. FR PVC insulated, copper wire suitable for 230V 50HZ, single phase suppy etc. complete as required.1200 mm ( 48\") BLDC 5 Star rating 32W Ceiling Fan
111Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. \"P\" trap 15 liters C.I. Pull and let go flushing cistern of names or other I.S.S.equipment make, complete with all fittings, C.I. or C.c. brackets 32mm alkathene/P.V.V. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull inlcuidng supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. dody brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificaiton and direction of E/I.(A) 580 mm. long(a) with 10lit low Level PVC Cistern
112Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With \"P\" trap of parry Hindustan or any othe approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joint spindla stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with bras coupling at both ends and white/blcok plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinger or screws etc. pain over a coat of red oxide priming all complete as per specification and direction of E/I.(b) With 10 ltr low level PVC cistern
113Providing and fixing wash basin with C.I. Rackets, 15mm C.P. Brass pillar taps, 32mm C.P. Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15mm C.P. Brass pillar tasp.
114Supplying, fitting and fixing the following items complete with all materiasl as per specification and direction of E/I. (a) glass shelf with C.P. Brass rail (i) 600x125mm glass shelf complete
115Providing and fixing PTMT Bottle Trap fow Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270mm effective length of tail pipe 260mm from the entre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less the 260 gms.
116Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the samd materials with snap fitting aof approved quality and colour wieghing not less than 105 gms.
117Providing & fixing PTMT towel ring trapezoidal shape 215mm long 200mm wide with minimun distance of 37 mm from wall face with concraled fittings arrangement of approved quality and colour weighing ont less than 88 gms.
118Providing and fixing C.P. BrassBib Cock of approved quality conrorming to IS 893115 mm. Nominal bore
119Providing and fixing C.P. Brass angle valve for basin mixer and geyser points of approved quality conrorming to IS 8931 a) 15mm nominal bore.
120Providing and fixing toilet paper holder:C.P. brass
121Providing andfixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion,
12275 mm diameter
123110 mm diameter
124Providing and fixing on wall face unplasticised-PVC moulder fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13595 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion.
125Coupler 110mm dia
126Single tee with door 110x110x110mm
127Bend 87.50 110mm dia
128Shone (Plain) 110mm dia
129Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) sand making good the wall etc. complete.
13075mm dia
131110mm dia
132Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fitting inlcuding fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittins with one step CPVC solvent cement and testing of joints complete as per direction of E/I.Internal work-Exposed on Wall
13315 mm nominal outer dia pipes
13425mm nominal outer dia pipes
13532mm nominal outer dia pipes
136Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fitting inlcuding fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittins with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of jointscomplete as per direction of E/I.Concealed work including cutting chases and mkaing good the wall ect.
13725mm nominal outer dia pipes
13832mm nominal outer dia pipes
139Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
140Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI :12701 marked with cover and suitable locking arrangement and making necessary hole for inlet, oulet and over flowpipes but without fitting and the base support for tank.
141Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well asfule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.Concealed work including cutting chases and mkaing good the wall ect.
142From 0.00 M to 50.00 M below G.L.
143From 51.0 M to125.00 M
144From126.0 M to150.00 M
145Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia.
146Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any otherapproved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
147Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
148Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
149Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable forworking on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP
150Supply fitting and fixing of standared make starter pannel Board with arrangement of all necsssury protection including all taxes, all complete job as per direction of E/I.
151Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
152Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I
153Add 18% GST (In Basic Rate must fill 0.18)
154Add 1% Labour cess (In Basic Rate must fill 0.01)

AI Tender Summary

OUR REF NO 36560691
AUTHORITY Government Departments
TENDER VALUE 55.48 Lakhs
LAST DATE 11-03-2023
Authority
Authority Name Building Construction Department
Work Description Construction Of Health Sub Centre Jagarnathpur, Block- Narayanpur, District- Jamtara For The Year 2022- 23
Basic Detail
Tender No BCD/SE,Dumka/09/Jamtara/22-23
Bidding Type Tender
Location
City jamtara
State Jharkhand
Key Dates
Publish Date 02 Mar 2023
Submission Date 11 Mar 2023
Open Date 13 Mar 2023
Finance
Tender Value 55.48 Lakhs
Tender Fee 10000
EMD 1.11 Lakhs
Exemption Not Available
Document List
3d8485f0-ed4d-437e-82b0-dbf7c84025aa.html
BOQ_90161.xls
F2-Document.pdf
Sankalp_Ltr._no._2146_S__.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 02, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 11, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 13, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3d8485f0-ed4d-437e-82b0-dbf7c84025aa.html

xls

BOQ_90161.xls

pdf

F2-Document.pdf

_no

Sankalp_Ltr._no._2146_S__.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders