Archaeological Survey Of India -ASI has published Tender For Mw(Con.) Special Repair To The External And Internal Surfaces Of Hazarduari Palace, Murshidabad.. Submission Date for this Tender is 14-03-2023. Archaeological service Tenders in hazarduari West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Description of work to be executed |
2 | Scraping of moss, blisters etc. thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
3 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
4 | Removing old paint from blistered painted surface with application of soda, sajimati or any approved chemical paint remover and exposing the original surface including cleaning and thorough washing to remove all traces of the removing agent including taking out shutters and refixing the same where necessary. |
5 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
6 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
7 | Sand and lime plaster including rounding off or chamfering corners as directed and raking out joints where necessary. |
8 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
9 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
10 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade |
11 | Painting (on timber/steel surface) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
12 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
13 | Provision for replacing the damaged round bar reinforced elliptical cage grills at foundation basement of HDP with new one and fitting and fixing at same places |
14 | Provision for replacing the damaged round bar reinforced rectangular cage grills along the staircases of HDP with new one and fitting and fixing at same places |
15 | Provision for lime processing/mortar preparation unit made by bamboo frame & covering ploy tarpaulin (10"x10") with 5 nos. masonry chambers (9"x5" -2 nos., 6" x7", 8"x4", 7"x5") by brick masonry plastering chequred cement tiles platforms with water connection from 200 m distance from main source for conservation. |