Tender For College Of Agriculture, Susunia, Chhatna, Banklura, Bankura-West Bengal

Bidhan Chandra Krishi Viswavidyalaya has published Tender For College Of Agriculture, Susunia, Chhatna, Banklura. Submission Date for this Tender is 15-03-2023. Cutting Crimping and Punching Tools Tenders in Bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

36545420
Tender For College Of Agriculture, Susunia, Chhatna, Banklura
Open Tender
Indian
West Bengal
Bankura
15-03-2023

Tender Details

Tender For College Of Agriculture, Susunia, Chhatna, Banklura-Equipment Purchase , Environmental Shaker: Outer Ms Powder Coated , Inner Ss304 , Vetical Model , 10X250ml , 3 No Ss Ware Mesh Tray , Shaking Speed 40-370Rpm, Vfd Controlled ( With Outpully ) Temp-4-60 Degc , Humidity-45-95%, Touch Screen Hmi +Iot+ Plc+Rfid Lock Based ( Temp+Humidity+Rpmgraph, Data Analysis+History-3Yrs+Rs 485 Interface For Data Print, Software ) All Should Be In One Screen& Controlled. Product Should Be Iso9001-2015, Ce Certified , Horizontal Autoclave: Redial Locking Double Walled Outer Ss304 , Inner Ss 304, Capacity-52 Ltr, With Boiler, Automatic ( Programmable Sterilization Timmer High Temp Safety Alarm, Automatic Cycle Abortion At High Temp Limit, Computated Saturated Stem Pressure Indication, Independents Air Exhaust And Sterilization Set Points With Rs485 Interface With 21Cfr Software For Pc Recording. Product Should Be Iso9001-2015, Ce Certified , Hot Plate: Size 420 X 320 X 130 Mm Ht. Weight 9 Kg, Voltage 230V ( 50Hz ) , Temperature 250°C Maximum Uniformity + / - 2°C.Temperature Rise 6°C Per Minute , Laminar Air Flow Chamber: Design So As To Meet The Requirement Of Us Federal Staandard209b, Class 100, Ulpa Filter 99.99%, Moc-Outer Ss304, Inner Table –Ss304 ( Polish ) , Uv Light , Prefilter, Digitalmagnehilic, Size-2X2x2 Ft; Product Should Be Iso9001-2015, Ce Certified , Mechanical Soil Auger: Sample Ring Kit, Standard Set To A Depth Of 2 M For Soil Sample Rings Ø 60 Mm. Soil Sample Ring Kits Are Used For A Variety Of Tests, Including Bulk Density Determination Of Soil. Soilsampleringkits The Various Sets Are Different From Each Otherbecause Of The Ring Holder Applied, The Diameter Ofthe Rings Connection, The Selected And The Samplingmethod. The Sample Sets With The Postfix Sa Are Applied Tofill The Soil Sample Rings In Soft Soils Above Thegroundwaterlevel. The Samples Can Be Taken On The Surface, In Boreholes Or In Profile Pits. The Open Ring Holder In Thisset Is Fitted With A Bayonet Connection And Is Drivenintothesoilmanually. The Set, Among Other Items, Contains: An Open Ringholder, Anedelman-Andariversideauger, Ahandle And Extension Rods, An Aluminium Casewithsoilsamplerings, Variousaccessoriesandacarryingbag. Thesamplesetswiththepostfixsacanbeobtainedforsoilsampleringswithadiameterof 53And60mm.Themostcommonlyapplied ( Standard ) Diameteris53mm. Thesearethenusedfor, Forexample:?Themoisturecontentatvariousmoisturetensions, Fromwhichapf-Curvecanbemade.?The Waterpermeability.?Theairpermeability. ?Theweightbyvolume.?Thedensity.?Thesoil-Water-Airrelationshipatfieldcapacity.?Theporedistribution.?Theoxygendiffusion. Soilsampleringsaretransportedinspecialaluminiumcases, Strongandresistantagainsthumidityandheat. Core Cutter Method According To Dutchraw Standard 2000, Test 4.4, The Set With The Equipment For The Core Cuttermethod Is Used For Other Applications As The Soilsampleringkitsdescribedbefore.Thesetisespeciallyusedforworksofcivilengineeringconstruction.Thecorecuttermethodisusedforthedeterminationof The Density And The Soil Moisture Content Ofembankment- Or Foundation Material Accoring To Thedutchraw-Standard2000. With A Drop Weight And A Guide Cylinder A Specialstainlesssteelsamplering, Withadiameterof 95.7X102mmandaheightof81.5Mm, Ishammeredintothesoilsurface.The Sampled Material Is Transported To The Labora-Tory, Where After Weighing And Drying, The Densityandsoilmoisturecontentisdetermined. , Microwave Digestion System: Internalvolume :67L.Ofvessel : 6 Microwaveoutput : 1800W, Temperature Range: 100~250°C, Operatingpressure : 40 Bar. Operatingpressure : Ptfe-Tfm, Fluoropolymer Batchprocesspertime :Min.1Pcs-Max.14Pcs. Microwavefrequency : 2450Mhz, Display : 7Inchvgacolortouchscreen, Environmentalcondition : Temperature -15~35°C , Humidity - <85%, Insulationclass: Digestiontankmaterial:Tfm, Peek, Pom Minimumfillingvolume :0.5Ml.Minimumcapacityofvessel : 30Ml, Temperaturemeasurement :Pt100.Max.Pressure : 1000Psi ( 7Mpa ) , Max.Temperature :250°C. Powersupply :Ac220v / 50Hz, Singl.E-Phase10a - Newintelli-Systemdesignedforvirtuallyeffortlessoperation- Largecavitytodigestmaximumnumberofsampleatatime - Large7-Inchscreenwithintegratedgraphicaluleasestheprocedurefromstarttofinish- Efficientandprecisepowerdelivery Foroptimumresults- Systemprovidespre-Setmodesfor Theusersease- Fullmetallicconstructionforstructuralstrength&Rigidity- Conversionofconventionalconditionstomicrowavedigestionparametersisprovidedbythesystem---Safety / Securityandovershootwarningsfortheuser - Intelligentinternalsensorscut-Offsystemfunctioningforuserssafety - Piezoelectricpressuresensorforaccuratemonitoringofpressureinsidethevesselduringthedigestion&Helpsinacompletedigestionprocess. - Allvitalinformationsuchasreal-Timetemperature, Pressure, Digestion Graphsaredisplayed.---- Integratedstep-By-Stepguidancefordigestion - Optimizedpositionofmagnetronforlow-Trajectorymicrowaveintroduction - Dynamicadjustmentofmicrowavepowerbasedondigestionavoids Temperatureovershoots. ---Non-Pulseandcontinuousheatingcontrollablein1wattincrements - Temperaturesensorsprovideforastabletemperatureholdtime - Multilayerchemicalresistancecoatinginsidethecavityimprovestheservicelifeand Safetyofsystem - Integratedplatinum ( Pt ) Resistance Temperaturesensorforaccuratemeasurementoftemperatureinsidethevessel - Outervesselofourdigestionsystemaremadeofultrastrengthcomposite Fiberisinvincible Inanti-Explosion, Corrosionresistant, Hightemperatureandpressureresistant - The Machine Owns Self-Test Function, Automatic Judge Fault States To Prevent Accidents ( Such As Abnormal Sound Check, Abnormal Temperature Check And Equipment Running Check Etc. ) Also It Has Door State Monitoring Function, The Machinecannot Startuntilthedoorclosedcorrectly - Inner Vessel Are Made Up Of Tfm Which With Stand High Temperature & Acid Resistant Every Digestion Vessel Is Placedhorizontally In The Vessel Frame, So The Vessel Frame Has Enough Strength For Balancing Vertical. Expansive Forces Whentheinternalpressurerisescontinuously - High Power Anti-Corrosion Axial Fan Which Owns High Efficiency Cooling, Only 20 Minutes To Decreasing Temperature Of200ºcto70ºc -With Iot All Data Should Be On Mobile / Laptop Through Wifi , Precision Drier: Precision Dryer :Outer Ms Powder Coated , Inner Polish Ss304 , Tepm Range-Ambeint To 250Deg C + / -.1 Degc, Ss Wire Mesh Tray 3 Pc, Blower , Size-24X36x36, Touch Screen Hmi + Plc+Rfid Lock Based Temp. Controlled ( Temp Graph, Data Analysis+History-3Yrs+Rs 485 Interface For Data Print, Software , Refrigerator-Temperature Control: Touch Screen Hmi + Plc+Rfid Lock Based Temp. Controlled , Outer Shoud Be Ss 304 Polish 1.6Mm Thick , Inner 304 Polish, Temp Range -4 Degc To 40 Degc , ( Temp Graph, Data Analysis+History-3Yrs+Rs 485 Interface For Data Print, Software ) , Insulation-Puf Internal Capacity- 160Ltr. Product Should Be Iso9001-2015, Ce Certified , Top Loading Balance : • Capacity:220G To 6200G ( Depending On Model ) • Minimum Display:0.001G To 1G ( Depending On Model ) • Linearity:0.002G To 1G ( Depending On Model ) • Calibration Type:Manual , Vertical Autoclave: Outer Ss, Inner Ss ( Thick ) , Capacity-40 Ltr , Automatic ( Programmable Sterilization Timmer High Temp Safety Alarm, Automatic Cycle Abortion At High Temp Limit, Computated Saturated Stem Pressure Indication, Independents Air Exhaust And Sterilization Set Points With Rs485 Interface. Pressure-5-20Psi . Product Should Be Iso9001-2015, Ce Certified , Digital Room Thermometer : Measuring Parameters Relative Humidity, Temperature Elative Humidity Ands Temperature Temperature 0 To +50 °C Accuracy_1 ±0.5 °C ( At +25 °C ) Resolution_1 0.1 °C Humidity 10 To 95%Rh Accuracy_2 ±3 %Rh Resolution_2 0.1 %Rh Display Lcd Display With Size 2 Lines Operating Temperature 0 °C To +50 °C Storage Temperature -40 To +70 °C Measuring Rate 18 Seconds , Gps Machine: Standard Survey And Mapping Type Gps

Key Value

Document Fees
Refer document
EMD
INR 10000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : COLLEGE OF AGRICULTURE, SUSUNIA, CHHATNA, BANKLURA
Sl. No. Item Description
1Environmental Shaker: Outer ms powder coated , inner ss304 , vetical model ,10x250ml , 3 no ss ware mesh tray ,shaking speed 40-370rpm,vfd controlled (with outpully)temp-4-60 degc , humidity-45-95%, touch screen hmi +iot+ plc+rfid lock based (temp+humidity+rpmgraph,data analysis+history-3yrs+rs 485 interface for data print, software) all should be in one screen& controlled. Product should be iso9001-2015,ce certified
2Horizontal Autoclave: Redial locking double walled outer ss304 , inner ss 304, capacity-52 ltr,with boiler, automatic(programmable sterilization timmer high temp safety alarm, automatic cycle abortion at high temp limit, computated saturated stem pressure indication, independents air exhaust and sterilization set points with rs485 interface with 21cfr software for pc recording. Product should be iso9001-2015,ce certified
3Hot Plate: Size 420 x 320 x 130 mm Ht. Weight 9 kg, Voltage 230v (50Hz),Temperature 250°C maximum Uniformity +/- 2°C.Temperature rise 6°C per minute
4Laminar Air flow chamber: design so as to meet the requirement of us federal staandard209b, class 100, ulpa filter 99.99%, moc-outer ss304, inner table –ss304(polish), uv light , prefilter,digitalmagnehilic, size-2x2x2 ft; Product should be iso9001-2015,ce certified
5Mechanical Soil Auger: Sample ring kit, standard set to a depth of 2 m For soil sample rings Ø 60 mm. Soil sample ring kits are used for a variety of tests, including bulk density determination of soil. Soilsampleringkits The various sets are different from each otherbecause of the ring holder applied, the diameter ofthe rings connection, the selected and the samplingmethod. The sample sets with the postfix SA are applied tofill the soil sample rings in soft soils above thegroundwaterlevel. The samples can be taken on the surface, in boreholes or in profile pits. The open ring holder in thisset is fitted with a bayonet connection and is drivenintothesoilmanually. The set, among other items, contains: an open ringholder,anEdelman-andaRiversideauger,ahandle and extension rods, an aluminium casewithsoilsamplerings,variousaccessoriesandacarryingbag. ThesamplesetswiththepostfixSAcanbeobtainedforsoilsampleringswithadiameterof 53and60mm.Themostcommonlyapplied(standard)diameteris53mm. Thesearethenusedfor,forexample:?Themoisturecontentatvariousmoisturetensions,fromwhichapF-curvecanbemade.?The waterpermeability.?Theairpermeability. ?Theweightbyvolume.?Thedensity.?Thesoil-water-airrelationshipatfieldcapacity.?Theporedistribution.?Theoxygendiffusion. Soilsampleringsaretransportedinspecialaluminiumcases,strongandresistantagainsthumidityandheat. Core cutter method according to DutchRAW standard 2000,test 4.4, The set with the equipment for the core cuttermethod is used for other applications as the soilsampleringkitsdescribedbefore.Thesetisespeciallyusedforworksofcivilengineeringconstruction.Thecorecuttermethodisusedforthedeterminationof the density and the soil moisture content ofembankment- or foundation material accoring to theDutchRAW-standard2000. With a drop weight and a guide cylinder a specialstainlesssteelsamplering,withadiameterof 95.7x102mmandaheightof81.5mm,ishammeredintothesoilsurface.The sampled material is transported to the labora-tory, where after weighing and drying, the densityandsoilmoisturecontentisdetermined.
6Microwave digestion system: InternalVolume :67L.ofvessel : 6 MicrowaveOutput : 1800W,Temperature range: 100~250°C, Operatingpressure : 40 bar. Operatingpressure : PTFE-TFM,FluoroPolymer BatchProcessPerTime :min.1pcs-max.14pcs. MicrowaveFrequency : 2450MHZ, Display : 7inchVGAcolortouchscreen, EnvironmentalCondition : Temperature -15~35°C , Humidity - <85%, Insulationclass: DigestionTankMaterial:TFM,PEEK,POM Minimumfillingvolume :0.5ml.Minimumcapacityofvessel : 30ml, Temperaturemeasurement :PT100.Max.Pressure : 1000psi(7MPA), Max.Temperature :250°C. Powersupply :AC220V/50HZ,singl.e-phase10A - NewIntelli-Systemdesignedforvirtuallyeffortlessoperation- LargeCavitytodigestmaximumnumberofsampleatatime - Large7-inchscreenwithintegratedgraphicalUleasestheprocedurefromstarttofinish- Efficientandprecisepowerdelivery foroptimumresults- SystemprovidesPre-SetModesfor theuser"sease- FullMetallicConstructionforstructuralstrength&rigidity- ConversionofconventionalconditionstoMicrowavedigestionparametersisprovidedbythesystem---Safety/securityandovershootwarningsfortheuser - IntelligentInternalSensorscut-offsystemfunctioningforuser"ssafety - PiezoelectricpressuresensorforaccuratemonitoringofPressureinsidethevesselduringthedigestion&helpsinacompletedigestionprocess. - Allvitalinformationsuchasreal-timetemperature, Pressure,Digestion graphsaredisplayed.---- Integratedstep-by-stepguidancefordigestion - Optimizedpositionofmagnetronforlow-trajectoryMicrowaveintroduction - DynamicadjustmentofMicrowavepowerbasedondigestionavoids temperatureovershoots. ---Non-pulseandcontinuousheatingcontrollablein1wattincrements - Temperaturesensorsprovideforastabletemperatureholdtime - MultiLayerchemicalresistancecoatinginsidethecavityimprovestheservicelifeand safetyofsystem - IntegratedPlatinum(Pt)resistance temperaturesensorforaccuratemeasurementofTemperatureinsidethevessel - OutervesselofourdigestionsystemaremadeofUltraStrengthComposite Fiberisinvincible inanti-explosion,corrosionresistant,hightemperatureandpressureresistant - The machine owns self-test function, Automatic judge fault states to prevent accidents(such as abnormal sound check,abnormal temperature check and equipment running check etc.) Also it has door state monitoring function, the machinecannot startuntilthedoorclosedcorrectly - Inner vessel are made up of TFM which with stand High Temperature & Acid Resistant Every Digestion vessel is placedhorizontally in the vessel frame, so the vessel frame has enough strength for balancing vertical. expansive forces whentheinternalpressurerisescontinuously - High power anti-corrosion axial fan which owns high efficiency cooling, Only 20 minutes to decreasing temperature of200ºCto70ºC -With IOT all data should be on mobile/laptop through wifi
7Precision drier: Precision dryer :outer ms powder coated , inner polish ss304 ,tepm range-ambeint to 250deg c +/-.1 degc,ss wire mesh tray 3 pc, blower , size-24x36x36, touch screen hmi + plc+rfid lock based temp. Controlled (temp graph,data analysis+history-3yrs+rs 485 interface for data print, software
8Refrigerator-temperature control: Touch screen hmi + plc+rfid lock based temp. controlled ,outer shoud be ss 304 polish 1.6mm thick , inner 304 polish, temp range -4 degc to 40 degc , (temp graph,data analysis+history-3yrs+rs 485 interface for data print, software), insulation-puf internal capacity- 160ltr. Product should be iso9001-2015,ce certified
9Top loading balance : • Capacity:220g to 6200g (depending on model) • Minimum Display:0.001g to 1g (depending on model) • Linearity:0.002g to 1g (depending on model) • Calibration Type:Manual
10Vertical Autoclave: Outer SS, Inner SS(thick) , Capacity-40 Ltr , Automatic(Programmable Sterilization timmer High temp safety alarm, automatic cycle abortion at high temp limit, computated saturated stem pressure indication, independents air exhaust and sterilization set points with RS485 interface. Pressure-5-20psi . Product should be iso9001-2015,ce certified
11Digital Room Thermometer : Measuring Parameters Relative Humidity, Temperature elative Humidity ands Temperature Temperature 0 to +50 °C Accuracy_1 ±0.5 °C (at +25 °C) Resolution_1 0.1 °C Humidity 10 to 95%RH Accuracy_2 ±3 %RH Resolution_2 0.1 %RH Display LCD Display with size 2 lines Operating Temperature 0 °C to +50 °C Storage Temperature -40 to +70 °C Measuring Rate 18 Seconds
12GPS Machine: Standard Survey and Mapping type GPS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail