}

Bids Are Invited For 1 Supplying, Installation And Testing And Commissioning Of 80 Litre Capacity, Seamless, High Pressure, Cylinder Assembly, Conforming To Is - 7285 ( Pt-2): 2004 Or Ul - 2166 Etc. Complete As Required Including Valve, Bracket Assemb, Dharwad-Karnataka

Airports Authority Of India has published Bids Are Invited For 1 Supplying, Installation And Testing And Commissioning Of 80 Litre Capacity, Seamless, High Pressure, Cylinder Assembly, Conforming To Is - 7285 ( Pt-2): 2004 Or Ul - 2166 Etc. Complete As Required Including Valve, Bracket Assemb. Submission Date for this Tender is 22-03-2023. Tanks and Cylinders Tenders in Dharwad Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

36542689
Bids Are Invited For 1 Supplying, Installation And Testing And Commissioning Of 80 Litre Capacity, Seamless, High Pressure, Cylinder Assembly, Conforming To Is - 7285 ( Pt-2): 2004 Or Ul - 2166 Etc. Complete As Required Including Valve, Bracket Assemb
Open Tender
Indian
Karnataka
Dharwad
22-03-2023

Tender Details

Bids Are Invited For 1 Supplying, Installation And Testing And Commissioning Of 80 Litre Capacity, Seamless, High Pressure, Cylinder Assembly, Conforming To Is - 7285 ( Pt-2 ) : 2004 Or Ul - 2166 Etc. Complete As Required Including Valve, Bracket Assembly, Pressure Gauge And 2 Inch Flexible Discharge Hose Etc. Complete As Required. Each 1 2 Supplying, Installation And Testing And Commissioning Of 34 Litre Capacity, Seamless, High Pressure, Cylinder Assembly, Conforming To Is - 7285 ( Pt-2 ) : 2004 Or Ul - 2166 Etc. Complete As Required Including Valve, Bracket Assembly And 2 Inch Flexible Discharge Hose Etc. Complete As Required. Each 1 3 Supplying And Filling Of Clean, Odourless, Colour Less, Ul Listed And Suitable For Fire Class - A, B & C Fire Suppression Agent ( Novec 1230 Fire Protection Fluid ) Etc. Complete As Required. Kg 70 4 Supplying, Installation, Testing And Commissioning Of 24 V Dc, Electric Actuator And Local / Manual Pneumatic Actuator For Triggering The Cylinder Assembly Etc. Complete As Required. Set 2 5 Supplying, Installation, Testing And Commissioning Of Low Pressure Switch For The Cylinder Assembly Etc. Complete As Required. Each 2 6 Supplying, Installation, Testing And Commissioning Of Manual Gas Release Station Etc. Complete As Required. Each 2 7 Supplying, Installation, Testing And Commissioning Of Manual Gas Abort Station Etc. Complete As Required. Each 2 8 Supplying And Fixing Of Suitable Size ( As Per Hydraulic Flow Calculation ) Nozzle With Orfices Etc. Complete As Required. Each 4 9 Supply And Laying Of Ms Pipe ( M.S. Seamless To Astm A-106, Sch. 40 ) Red Painted With All Fittings & Supports, Etc. On Surface / Recess / Above False Ceiling / Concealed Space / Wall Concealed Complete As Required As Per Site Requirement. Lot 2 10 Supply, Installation, Testing & Commissioning Of Ul / En Listed ( Latest Version ) Modular Microprocessor Based Expandable Intelligent Addressable Type Fire Alarm Control Panel With Gas Release Module Of Two Loops, With Minimum 320 Character Graphics / Lcd Display With Touch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non-Volatile Memory ( Eprom ) , The Panel Should Be Equipped With Loop Capacity To Take Minimum 240 Intelligent Addressable Detectors / Devices ( In Any Combination ) In One Loop. Four Access Levels, Capable Of Taking Protocol Devices, Graphical Display, Sufficient Numbers Of Programmable Relay Controls For Controlling Ventilation Fan, Fire Pump Room, Monitoring Of Fire Sprinkler And Fire Hydrant Pump, 230 Volts, 50 Hz Ac Power Supply, Automatic Battery Charger, 24 Volts Sealed Maintenance Free Lead Acid Batteries Sufficient For 2 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During An Emergency / Fault Conditions Along With Battery Stand As Required. The Panel Shall Have Facility For Seamless Integration With Pa System ( For Giving Trigger Signal To Start Pre-Recorded Digital Voice Evacuation From Pa System In Case Of Fire ) . The Panel Shall Be Compatible For Building Management System With Open Protocol Bacnet / Modbus Etc. As Per Specification, Complete As Required. Job 1 11 Supply, Installation, Testing & Commissioning Of Ul / En Listed ( Latest Version ) Intelligent Addressable Multi Criteria Detector { Smoke + Heat } With Inbuilt Fault Isolator / Isolator Base And With Unique Optical Sensing Chamber, Visible Led, Fully Coated Circuit Board, Superior Rf / Transient Protection Suitable For 2 Wires Loop Connection, Complete With Plug Into Common Separate Base & Housing Constructed Of Lexan ( Or Polycarbonate ) Complete With Connections Etc. As Required And To Be Installed Below / Above False Ceiling Roof And Concealed Space And As Per Enclosed Specifications , Complete As Required. ( Cost Of Plug In Common Base Shall Deemed To Be Included In Cost Of Detectors ) Each 12 12 Supply, Installation, Testing And Commissioning Of Ul / En Listed ( Latest Version ) Response Indicators For Getting Fire Indications Of Detectors I / C Mounting Boxes Installed Above False Ceiling Area Interconnecting To Loop Cable Etc. As Per Specification Complete As Required. Each 6 13 Supply, Installation, Testing & Commissioning Of Ul / En Listed ( Latest Version ) Intelligent Addressable Manual Call Station ( Resettable Pull / Push Type ) Suitable For Semi Flush Mounting, Ip 54 With Inbuilt Fault Isolator / Isolator Module With Double Gang Outlet Box, Equipment For Key Operated Test-Reset Lock, Electronic Or Rotary Switches For Address Setting. Manual Pull Station Shall Be Connected With Two Wire To Slc Loop Of Fire Control Panel. Cover Shall Be Made Out Of Lexan ( Or Polycarbonate Equivalent ) With Clear Operating Instruction And The Word Fire Appearing On The Front Complete With Connections Etc. As Required And As Per Enclosed Specifications. Each 2 14 Supply, Installation, Testing And Commissioning Of Ul / En Listed ( Latest Version ) Loop Powered Addressable Hooter-Cum- Strobe With Inbuilt Fault Isolator / Isolator Module With Adjustable Sound Level In The Range Of Min. 90 Db To Max. 120 Db At 1M Distance Complete With Termination Etc. As Required And As Per Enclosed Specification. Each 2 15 Supply, Installation, Testing And Commissioning Of Conventional Fire Alarm Control Panel Having Minimum Of 2 Zones Suitable For Connecting Sensors, Manual Call Points, Hooters And Response Indicators Operation On 230 Volts, 50 Hz Power Supply, Lcd Display To Indicate Fire And Normal Operation & Power Supply Status, Push Button For Accept And Reset, Sealed Lead Acid Batteries With Minimum 24V Dc Backup On Alarm Mode & Normal Operation Mode With Battery Charger Etc., Shall Be Complete As Required. Panel Shall Have Necessary Provision For Connecting And Functioning With Auto Dialler Etc As Required. ( Make: As Per Aai Approved Makes List ) Each 1 16 Sitc Of Auto Dialler With Landline Dialler Capability Complete With All Necessary Accessories Including Connections Etc. As Required. Each 1 17 Supply & Fixing Of Indoor Manual Call Point Complete With All Accessories Including Connections Of Etc. As Required. ( As Per Approved Makes List ) Each 1 18 Sitc Of Hooter With Base Plate Etc As Required. ( As Per Approved Makes List ) Each 1 19 Supply & Fixing Of Conventional Type Photoelectric, Multi Sensor Smoke Detectors Along With Mounting Base With Unique Optical Sensing Chamber, Visible Leds Fully Coated Circuit Boards With Rf / Transient Protection, Complete With All Accessories Including Connections Etc. As Required. ( As Per Approved Makes List ) Each 2 20 Supply And Laying Of Ms Steel Conduits Isi Marked Red Painted With All Fittings And Saddles For Drawing Detector Control Cables On Surface / Recess / Above False Ceiling / Concealed Space / Wall Concealed, Etc Of Following Sizes: 20 Mm Mtr 150 21 Supply And Laying Of Following Size Pvc Insulated Frlsh 2Cx2.5Sq.Mm Copper Conductor Cable Through Conduits / Surface / Recess / Above False Ceiling / Concealed Space / Wall Concealed, Etc. For Control Cabling For Fire Detection & Alarm Devices And Interconnecting Etc As Required. ( As Per Approved Makes List ) Mtr 150 22 Supply And Installation Of Fire Bucket Stand With Canopy Consisting Of 04 No’S Of Buckets, Fire Bucket Stand Made Of Angle Iron Size 40 X 40 X 6Mm Having Arrangement For Hanging Of 04 Nos. Bucket On Suitable Hooks Made Of Ms Round Bar, The Stand Should Be Painted With Post Office Red Enamel Paint, Fire Bucket Of Size 11X40x8 High Top Bottom Duly Painted By Post Office Red Enamel Paint Outside And White Enamelled Paint In Inner Side With Mark... Total Quantity : 421

Key Value

Document Fees
Refer document
EMD
INR 19134.0 /-
Tender Value
INR 11.28 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail