Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #36534045

Tender For Renovation Of Gymnasium And Student Activity Centre At Nsut East Campus, Geeta Colony During The Year 2022-23 ( Composite

Issued by Boards / Undertakings / PSU · Shahdara, Delhi
Tender Value
39.66 Lakhs
Estimated cost
Bid Submission
06 Mar 2023
0 days left
EMD
79326
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shahdara → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Of Gymnasium And Student Activity Centre At Nsut East Campus, Geeta Colony During The Year 2022-23 ( Composite

BOQ

Name of work:- Renovation of gymnasium and student activity centre at NSUT East Campus, Geeta Colony during the year 2022-23 ( Composite work).
Sl. No. Item Description
1Civil Work (Part-I)1 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
22 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
33 Providing and fixing mirror of superior glass (of approved quality) and of required size and thicknessof approved make and shade with 6 mm thick hard board backing :Rectangular shape any size as per requirement
44 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987,Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
55 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level :Cement mortar 1:4 (1 cement :4 coarse sand)
66 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
77 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
88 Providing and fixing soil, waste and vent pipes :100 mm dia Sand cast iron S&S as per IS - 1729
99 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe
1010 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : For 100 mm dia pipe
1111 Providing and fixing plain bend of required degree 100 mm dia Sand cast iron S&S as per IS - 1729
1212 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet and cast iron S&S as per IS: 3989
1313 Providing and fixing collar :100 mm Sand cast iron S&S as per IS - 1729
1414 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good thesame with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia
1515 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete
1616 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cementconcrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
1717 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls25 mm nominal dia Pipes
1815 mm nominal dia Pipes
1918 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charg
2019 Providing and fixing toilet paper holder C.P. Brass
2120 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
2221 Providing and fixing to existing door frames.30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
2322 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
2423 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
25Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete
2625 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mm Sand cast iron S&S as per IS - 3989
2726 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.For door/ window/ clerestory window
2827 Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.300 mm wide.
2928 Providing and laying in floorssuperior class 20 mm thick v groove Synthetic rubber tiles using good quality reputed make synthetic rubber adhesive @ 150 ml/sqm all completein required color and sizes as per complete satisfaction of theEngineer-In-chrge.Note: The rubber tile samples will be approved by the Engineer-in-Charge before the start of the work.
3029 Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms
3130 Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gms
3231 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
3332 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
3433 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Twin rubber stopper
3534 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
3635 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
3736 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer
3837 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.Two or more coats on new work
3938 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
40Electrical Work (Part-II)SH-01 (WIRING AND ACCESSORIES)1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a Group A
412 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a Group A
423 Supply and fixing suitable sizeGI box with modular plateand coverinfrontonsurfaceorinrecess includingprovidingandfixing6pin,5/6 A, 15/16Amps modular socket outlet and 15/16 Amps modular switch , connection etc. as required .
434 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/recessedsteelconduitasrequired a) 3 x 1.5 sq. mm
44b) 3 x 2.5 sq. Mm
45c) 3 x 4 sqmm
465 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
476 Supplying and fixing following modular switch/ socketontheexistingmodularplate&switchbox including connectionsbutexcludingmodularplate etc. as required.a) 5/6 A switch
48b) 3 pin 5/6 A socket outlet
49c) 15/16 A switch
50d) 6 pin 15/16 A socket outlet
51e) 2 way 5/6 A switch
527 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
538 Supplying and fixing following Modular base & coverplateonexistingmodularmetalboxesetc.as required.a) 1 or 2 Module
54b) 3 Module
55c) 6 Module
56d) 8 Module
57e) 12 Module
589 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole
59b) Single pole and neutral
6010 Supplying and fixing TPN MCB 63 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
6111 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
6212 Dismantling the existing worn out / defective fittings from the ceiling andSITC ofLED surface/wallbatten fitting minimum 20 watt with Aluminium housing and integrated electronic driver system efficacy minimum 100 lumen/watt LM79, color temp 6500 deg K as per required.
6313 Dismantling the existing worn out / defective fittings from the ceiling andSITC of minimum 36 watt Aluminium slim energy efficient LED Panel light fitting having system efficacy minimum 100 lumen/watt LM79, color temp 6500 deg K, recess mounting suitable for fitting in the 600mm x 600mm square existing space having symmetric glare free illumination in the false ceiling,complete with all standard accessories including drivers etc. complete as required
6414 Suppling and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess inculding cutting the wall and making good the same in case of recessed conduit as required.25MM PVC Conduit
65AIR CONDITIONING SupplyInstallation,Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating,having all hermetically sealed inverter type Scroll Compressor(s),minimum two compressors for above 14HP modules, microprocessor based Controller,top discharge type condensing unit(s),with R410A Refrigerant,vibration isolators,with suitable foundation etc. complete as required.The unit shall deliver the ratedcapacity at AHRI Conditions and work even at 50°C ambient temperature without tripping.The unit shall be suitable to work on 400V+/-10%,3Phase,50Hz AC power supply.The unit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .(ODU Unit should be anti corrosive coated from factory)30
6616 Supply,installation,testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc. suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.a) 2 TR
67b) 1.45 TR
68c) 1 TR
6917 Supply,Installation,testing & commissioning of Y Joints forIDU\"s
7018 Supply,Installation,Testing & commissioning of Central Remote Controller for controlling the all IDU\"s & ODU\"s
7119 Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete withfittings,with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometricnitrile rubbe rtubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required :a) 28.58 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
72b) 25.4mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mm thick insulation
73c) 22.2 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
74d) 19 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
75e) 15.86 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
76f) 12.7 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
77g) 9.5 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
78h) 6.4 mm dia(OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
7920 Supply Installation Testing and Commissioning Providing and fixing rigid PVC piping complete withfittings, supportsas perspecifications anddulyinsulatedwith9 mmthick closed cell nitrile rubber insulation.a) 25 mm
8021 Cutting holes of required size in brick masonry wall for passing of copper pipes, Drain pipes, cable removing of false ceiling and re-fixing/placing back if required etc. and making good the same etc. complete as per direction of Engineer-in-charge.(The hole shall be made by core cutter)
8122 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8223 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.a) 300 mm width X 50 mm depth X 1.6 mm thickness
8324 Supply ofXLPE insulated Copper conductor, armoured 1.1 KVgrade cable of following size complete as required.a) 4C x 6sqmm
84b) 4C x 10sqmm
85c) 4C x 25sqmm
8625 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
8726 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle)
8827 Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 4 X 10 sq. mm (25mm) or 4 X 6 sq. mm
89b) 4 X 25 sq. mm (28mm)
9028 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCBTPDB is normally used where 3 phase outlets are required.)a) 8 Way (4+24),Double door
9129 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 125 A, 16 KA,TPMCCB (Incomer to Vertical DB)
9230 SITC of 2.0 Tr capacity Split type air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supplywith ecofriendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.)
9331 SITC of 1.5 Tr capacity Split type air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10 % volt, 50 HZ, A.C supplywith eco friendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification..(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.)
9432 Supplying, Installation and welding the copper pipe with the existing pipe of 1.5/2 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping insidethe room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required.
9533 SITC of 2 TR /1.5 TR AC Outdoor unit powder coated stand with required as per site condition wall mounted / Floor Mounted.
9634 Supplying and Laying of one number 3 core 1.5/2.5 sqmm pvc insulated and pvc sheathed round wire on wall/surface/with refrigerant pipe etc for AC.
9735 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.
9836 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for looparthing as required.
9937 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
10038 Comprehensive Annual Maintenance of2/1.5 Tr capacity Inverter type/Non Inverter Type Split AC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging , replacement of compressor, motor,wiring,etc complete with all parts required for healthy and proper functioning of the Air Conditioning.(Nothing will be provided by the department during the period)a) Year 1 (after Defect Liability Period of One Year)
101b) Year 2
102c) Year 3
103d) Year 4
104e) Year 5
10539 Comprehensive Annual maintenance of VRV/VRF Air conditioning system provided and installed under this contract with all parts/components i.e compressor,gas charging,fan motor etc(one year free defect liability period and thereafter paid)a) For 1st Year (During defect liability period)
106b) For 2nd Year
107c) For 3rd Year
108d) For 4th Year
109e) For 5th Year
110f) For 6th Year
11140 Dismantling & Buy Back of old & defective following items as per required. a) 4 x 1 Light fitting.
112b) Ceiling Fans
113c) Fluorescent Tube light
114d) 2X2 Recess Fluorescent light

AI Tender Summary

OUR REF NO 36534045
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 39.66 Lakhs
LAST DATE 06-03-2023
Authority
Authority Name Netaji Subhas Institute Of Technology
Work Description Renovation Of Gymnasium And Student Activity Centre At Nsut East Campus, Geeta Colony During The Year 2022-23 ( Composite
Basic Detail
Tender No NIT No.65/EE/2022-23/NSUT
Bidding Type Tender
Location
City Shahdara
State Delhi
Key Dates
Publish Date 28 Feb 2023
Submission Date 06 Mar 2023
Open Date 06 Mar 2023
Finance
Tender Value 39.66 Lakhs
Tender Fee Ref. Documents
EMD 79326
Exemption Not Available
Document List
74021a31-7d97-4c24-a8c9-bfeed3a404ed.html
4324.pdf
BOQ_309305.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 28, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 06, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 06, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

74021a31-7d97-4c24-a8c9-bfeed3a404ed.html

pdf

4324.pdf

xls

BOQ_309305.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders