Tender For Renovation And Redevelopment Of Swimming Pool At Kamla Nehru Park Near Sadar Bazaar, Gurugram, Haryana. Recall, gurugram-Haryana

Urban Local Bodies has published Tender For Renovation And Redevelopment Of Swimming Pool At Kamla Nehru Park Near Sadar Bazaar, Gurugram, Haryana. Recall. Submission Date for this Tender is 24-04-2023. Swimming Pool Construction Tenders in gurugram Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

36523427
Corrigendum : Tender For Renovation And Redevelopment Of Swimming Pool At Kamla Nehru Park Near Sadar Bazaar, Gurugram, Haryana. Recall
Open Tender
Indian
Haryana
gurugram
24-04-2023

Tender Details

Renovation And Redevelopment Of Swimming Pool At Kamla Nehru Park Near Sadar Bazaar, Gurugram, Haryana. Recall

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Mar-2023 2023_HRY_261686_1 Date 31-03-2023
2 29-Mar-2023 2023_HRY_261686_1 s Date 07-04-2023
3 04-Apr-2023 2023_HRY_261686_1 n Date 12-04-2023
4 12-Apr-2023 2023_HRY_261686_1 d Date 24-04-2023

Key Value

Document Fees
INR 20000 /-
EMD
INR 2322000.0 /-
Tender Value
INR 11.60 Crore /-

BOQ Items

Name of Work:- Renovation and Redevelopment of Swimming Pool at Kamla Nehru Park Near Sadar Bazaar, Gurugram, Haryana.
Sl. No. Item Description
1Supply and Fixing of 1200 mm sweepMake High Speed Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials required.as per ECBCandGRIHAcompliance
2Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).White sand stone
3Providing and applying back coat sealer of approved make (as per drawing or as directed by project In charge)on back side and four edges of the stone and allowing it to cure for 24 hours before laying stone for flooring, application as per manufacture’s installation methodology. The sealer should be applied at the rate of 2 ltr per 150 sqft of surface area complete as per direction of Engineer in Charge.
4Providing and applying High performance top coat sealer of approved make (as per drawing or as directed by project incharge) on the exposed surface on stone to form invisible barrier by allowing vapour to escape for resistance against water alklies, acid staining and freeze thaw damages. The sealer should be applied at the rate of 2 ltr per 285 sqft of surface area complete as per direction of Engineer in Charge.
5Providing and fixing normal keys, 5 Pins Euro Profile cylinder with key to knob operation standard length 60mm in SS/ gold finish with 3 keys of approved quality with necessary screws and Master key .
6Providing and fixing normal keys, Euro Profile half cylinder 45mm length of gold finish with 5 normal keys of approved quality with necessary screws.
7Providing and fixing mortice sash lock with 45mm backset, 23mm square forend and 8mm follower with 72mm centers and prepared for euro profile cylinder including strike plate in SSS with latch bolt projection of 15mm and double bolt throw dead bolt of 18mm projection of approved quality with necessary screws.
8Providing and fixingfloor stop half dome with 50mm dia with fixing accessories, in satin stainless steel of approved quality
9Providing and fixing lever handle suit to 8mm follower with rosettes and escutcheonof approved quality with all necessary fixing accessories
10providing and fixing Pull Handle (425X 25) with Extended Spindle of Material-SS-304 of approved quality with all necessary fixing accessories
11Providing and fixing Tower Bolt( 6`) -SS304 of approved make with all fixing accessories
12Providing and fixing Glass Reinforced Concrete (G.R.C) Screens casted with `Spray Mix` concrete design in approved size, pattern, thickness of 50mm on the outer Border and 25-30mm for Internal member and shade. The Screens should be made from ‘53 grade’ White Portland Cement , White Quartz fine graded sieved Silica Sand, Alkali Resistant Glass Fiber , Owen Corning, Super Plasticizers , Polymersand U.V resistant Synthetic inorganic pigments should be used for pigmentation . The Screens casting shall take place with layering methodology using- Direct Power Spray machines. The GRC Screens flexural strength average L.O.P should be above or equivalent to 6 N/mm2 and M.O.R should be above or equivalent to 12 N/mm2 for tests done on 28 days cured samples. The fixing of Screens should be done using ‘Dry fixing’ method onto structural support members i.e. R.C.C, Brick work, MS Framework. SS / MS Galvanized CLAMPS and PINS also if required fasteners . ALL CAST IN SOCKET TO BE EPOXY PRIMER COATED. ELECTRODES . Vendor shall submit shop drawings of same, the drawings to be duly approved from Engineer in charge at site.
13Providing and fixing18 mm thickPolished Granite stone in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.
14Providing and fixing18 mm thick flamed finish Granite stone in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.
15Providing and fixing/laying swimming pool porcelene tiles 6mm of 4`x4` over cement mortar of 1:3, with filling of epoxy of reputed make such as Pidilite, Laticreto, ferrouscrete etc. as per IS specification 15477-2004 in joints with color pigment of matching shade,as per approved shade by architect, complete in all respects as per satisfaction of engineer in charge.
16Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.
17Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25Amodular socket outlet and 25A modular SP MCB,`C` cruve including connection etc. as required
18Supplying,installation,testing and commissioning of Astronomical time switch of followingconfigurationtobe mounted in feeder pillars/Lighting DBs for automatic switching On and OFF of street lights at sun set and sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required 1 output per phase and suitable for single phase supply
19Supplying,installation,testing and commissioning of Astronomical time switch of followingconfigurationtobe mounted in feeder pillars/Lighting DBs for automatic switching On and OFF of street lights at sun set and sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 2 output per phase and suitable for single phase supply
20Supply, Installation, testing and commissioning of Recess mounted 9W LED downlighterwill give nominal system lumen output of 990lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI)80,with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD ( 10% , High PF )0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range :100-300Vhaving High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
21Supply, Installation, testing and commissioning of Recess mounted 12W LED downlighterwill give nominal system lumen output of 1320lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI)80,with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD ( 10% , High PF )0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range :100-300Vhaving High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
22Supply, Installation, testing and commissioning of surface mounted 15W LED downlighterwill give nominal system lumen output of 1140lm and a system efficacy of 75lm/W. The luminare should have beam angle of 120Deg with a color temperature of 6000K and CRI)80. The luminaire shall meet IP20 rating with THD ( 10% , High PF )0.9,IK 05 and housing made of die cast Al with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range :100-275Vhaving High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be integral isolated.
23Supply, Installation, testing and commissioning of Recess mounted 15W LED downlighterwill give nominal system lumen output of 1650lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI)80,with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD ( 10% , High PF )0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range :100-300Vhaving High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
24Supply, Installation, testing and commissioning of surface and recessed mounting type Led light fixture, LED of 1 to 3 W each assembled on single MCPCB, having color temperature 5700 to 6500K and having 50000 burninghrs life with minimum @ L70, system lumen output should be minimum with efficacy) 80lm/W. LED driver, PF 0.95 and THD (20%. The colour rendering index of LED light should be more than70. HousingmadeofCRCA with glare free diffused polycarbonate cover. Submission LM 80-08 Form LEDSource Manufacturerand LM79-08 /IS16106 fromNABLapprovedLab. Manufacturer manadatoryi/cconnection wire, testing etc. tocompletethejob.2YrsGuaranteecertificatefrommanufacturer. 20W LED Hanging Light.
25Supply, Installation, testing and commissioning of 20W LED Batten will give nominal system lumen output of 2400lm and a minimum system efficacy of 120lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 5700K ,CRI)80. The luminaire shall meet IP20having CRCA housing powder coated and high efficient polycarbonate diffuser for better light distribution. The luminaire has the features of Input Voltage : 240V, 50/60Hz,p.f)0.95,THD(10% , with High Surge Protection : 4KV, Operating temperature : -10Deg to 45Deg ,IK05,Driver shall be integral and isolated.
26Supply, Installation, testing and commissioning ofrecess mounted square 2X2 36W LED luminariewill give nominal system lumen output of 3600 lm and a system efficacy of 100lm/W.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120 Deg with a color temperature of 5700K and CRI)80. The luminaire shall meet IP20 rating with High PF )0.95 and THD(10% . The luminaire housing should made of CRCA powder coated finish, high efficienctanti glare PMMA diffuser for better light distribution. The luminaire have separate energy efficent isolated driver and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with surge protection 2.5KV : Operating Temperature : 0 Deg to 45 Deg
27Supply, Installation, testing and commissioning ofrecess mounted square 2X2 20W LED luminariewill give nominal system lumen output of 2500 lm and a system efficacy of 125lm/W.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120 Deg with a color temperature of 5700K and CRI)80. The luminaire shall meet IP20 rating with High PF )0.95 and THD(10% . The luminaire housing should made of CRCA powder coated finish, high efficienctanti glare PMMA diffuser for better light distribution. The luminaire have separate energy efficent isolated driver and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with surge protection 2.5KV : Operating Temperature : 0 Deg to 45 Deg
28Supply, Installation, testing and commissioning of surface and recessed mounting type Led light fixture, LED of 1 to 3 W each assembled on single MCPCB, having color temperature 5700 to 6500K and having 50000 burninghrs life with minimum @ L70, system lumen output should be minimum with efficacy) 80lm/W. LED driver, PF 0.95 and THD (20%. The colour rendering index of LED light should be more than70. HousingmadeofCRCA with glare free diffused polycarbonate cover. Submission LM 80-08 Form LEDSource Manufacturerand LM79-08 /IS16106 fromNABLapprovedLab. Manufacturer manadatoryi/cconnection wire, testing etc. tocompletethejob.2YrsGuaranteecertificatefrommanufacturer. 12W bracket light
29Supply, Installation, testing and commissioning of 10W LED Bulkhead will give nominal system lumen output of 850lm and a minimum system efficacy of 85lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 6500K ,CRI)80. The luminaire shall meet IP65 with polycarbonate housingand high efficient polycarbonate diffuser for better light distribution. The luminaire has the features of Input Voltage : 240V, 50/60Hz,p.f)0.9,THD(10% , Operating Voltage 140-275with High Surge Protection : 4KV, Operating temperature : -10Deg to 45Deg ,IK05,Driver shall be integral and isolated.
30Supply, Installation, testing and commissioning of 10W LED ultraslim polycarbonate decorative LED batten (Mirror light) with inbuilt heat sink,anti glare polycarbonate diffuser with energy efficient electronic driver.The luminare should have beam angle of 120 Deg with a color temperature of 6500K .The luminaire has the features of Input Voltage :220- 240V,CRI )80 50/60Hz,p.f)0.9, Operating Voltage 90-305 .
31Supply, Installation, testing and commissioning ofWall Fan
32Supply, Installation, testing and commissioning of 18W under water light
33Supply, Installation, testing and commissioning of 70W Flood light
34Supply, Installation, Testing and Commissioning of Micro processor based 1 loop panel with optional redundant network module ,each loop shall have the capability of connecting 255 detectors and devices. The fire alarm control panel shall have built in degrade mode function. The panel should have inbuilt TCP/IP communication for Panel Program and Remote monitoring option through LAN or WAN communication. The panel shall be able to givelocation ofall fire and more Fire /fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 3000 events. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have a 320 x 240 dots monochrome LCD display with resolution and analog output. The Panel Should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The panel shall have a built in power supply and battery charger along withmaintenance free28AH, 2x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And as per specifications Panel shall be capable of integrating with BMS/ CCTV/PA system through Modbus/OPC. The panel shall be complied withEN 54/ Vds approved, CE certification. 1 Loop Panel
35Supply, Installation, Testing and Commissioning ofof Micro processor based 1 loop panel with optional redunadant network module ,each loop shall have the capability of connecting 255 detectors and devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote monitoring option through LAN or WAN communication.The panel shall be able to givelocation ofall fire and more Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 3000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have a 320 x 240 dots monochrome LCD display with resolution and analog output.The Panel Should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The panel shall have a built in power supply and battery charger along withmaintenance free28AH, 2x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications Panel shall be capable of integrating with BMS/ CCTV/PA system through Modbus/OPC. The panel shall be complied withEN 54/ Vds approved, CE certifcation. Graphical User Interface
36Supply, Installation, Testing and Commissioning of of Active Repeater Panel to be integrated with Fire Alarm Control Panel,larger LCD or LED display with resistive touch screen or function keys and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels,Panel should compliant with EN54.
37Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable Photoelectric Type Smoke Detector for Above and below ceiling and integral response indicator with 360 degree viewing angle. Detector shall communicate 4 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40. Detector shall comply with EN 54/ Vds, CE certified .
38Supply, Installation, Testing and Commissioning of Intelligent Analog Supply of Intelligent Analog Addressable Heat Detector (StaticplusROR)and integral indicator with 360 degree viewing angle. Detector shall communicate 4 danger levels for differentiated alarm activation. Detector should have unquie address for communication and assigned through panel with mounting base as required with the protection category of IP51 and duly approved by EN 54/Vds/CE certified .
39Supply, Installation, Testing and Commissioning of Response Indicator with matching screws complete with GI Junction box, Cable lugs at cable end and ferruling.
40`Supply, Installation, Testing and Commissioning of addressable short-circuit isolator Base for all types of detectors , fast connectorterminals for easy installation of any cable type One External Indicator (LED) can be connected to the base, Cable entry from top or side. Duly approved with to EN54-17/VdS/ CE certified Make: Panasonic/Bosch/Hochiki`
41Supply, Installation, Testing and Commissioning of Addressable Relay Module with Address Switch and all mounting accessories complete as required.Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts , MS Powder coated Junction Box and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
42Supply, Installation, Testing and Commissioning of Addressable Manual Call Station(Break Glass Type) with Adddress Switch and all mounting accessories , complete with MS Powder coated Junction Box for and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed
43Supply, Installation, Testing and Commissioning of Addressable Control /Relay Module with Address Switch and all mounting accessories, complete with MS Powder coated Junction Box and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
44Supply, Installation, Testing and Commissioning of Ceiling/ Wall Mounted Muli-Candela Strobe cum Hooter with all required accessories for mounting complete as required.
45Supply, Installation, Testing and Commissioning of Optical Beam Smoke Detector with Allows for 2 Detectors per System Controller. Range 5 to 100 metres, Allows for 2 Detectors per System Controller.Each Detector configurable from 8m to 100m. Separate Fire and Fault relays per Detector. Integral LASER alignment. Auto-Align Fast Automatic Beam Alignment. Building Movement and Contamination Compensation Low Level System Controller Tested and approved according to EN54 and VdS approval.
46SITC of addressable Monitor Module with built in isolator for monitoring inputs for flow switch or gas release in electrical panels or server rooms as applicable and as per specifications. Complete as required.Module shall comply with EN 54/ Vds, CE certified
47Supply, Installation, Testing and Commissioning of Power Supply Unit - 240VAC to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery Backup suitable for total Strobe cum hooter connection complete with all accessories as required.
48Supply and Laying of following sizes ofPVC sheathed Copper conductor armouredcable of 1.1 KV grade on surface including saddle, clamps, terminationetc. complete as required. 2CX 1.5 Sq mm 2core 1.5 Sqmm Fire survivalArmoured Cable
49Supply and Laying of following sizes ofPVC sheathed Copper conductor armouredcable of 1.1 KV grade on surface including saddle, clamps, terminationetc. complete as required. 2CX 2.5 Sq mm FRLSAr. Copper Cable
50Supply, Installation, testing and commissioningof 6W Recessed Ceiling speakers with following features:-Speaker Drive 4`, Complete metal grille and line matching transformer 100/70V line. Variable wattage tapings of 6 / 3 / 1.5 at 100v, Effective frequency range 90-18kHz (BS6840), SPL@1m/1W=90dB,Peak SPL 98dB complete with necessary mounting hardware and accessories.
51Supply, Installation, testing and commissioningof 6W wall mount speakers with following features:-component 7.5`, Complete metal grille and line matching transformer 100/70V line. Variable wattage tapings of 5/10W, Effective frequency range 150-15kHz (BS6840), SPL@1m/1W=90dB,Peak SPL 98dB complete with necessary mounting hardware and accessories.
52Supply, Installation, testing and commissioning of 6 zone Digital Voice Evacuation Master controllerwith built in 500watt Amplifier. The System shall meet the standards of BS EN54 - 32 and EN 60849. The System Shall have Built in 500W Class-D Amplifier and it should be capable for the EVAC, Paging, PA and BGM functions. The Controller shall have SD card option to store the EVAC and Alert Voice Message. The Controller shall have Speaker line supervision record out and amplifier auto changeover. The Controller shall have following features: Separate Zone volume control at the front side of panel, Status indications on the Panel for EVAC,Fault ,AC,DC ,Fault, ALERT and Fireman mic, Zone capacity up to 96 Zones, 8 programmable Control Input and output, Fireman Microphone with High Priority, THD(1%, Frequency response 80Hz - 20kHz, Up to 1000 Record files, 100V Class-AB Speaker Output.
53Supply, Installation, testing and commissioningof Remote Paging microphone with minimum 6 buttons and Busy/Hole Indication. The Microphone Should be suitable for Desktop mounting.
54Supply, Installation, Testing and Commissioning of (3 phase-3 wire INPUT and 3 phase 4 wire OUTPUT) Online UPS system suitable for input and output parameters. The UPS shall have inbuilt Isolation Transformer. UPS operated in PRS Mode. Parallel Kit required. The UPS shall be provided in powder coated fan cooled enclosure painted in color. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode through isolation transformer.The UPS shall have a microprocessor based display and control panel.UPS shall have own batteries with 15 minute battery back-up including MS Rack. Input voltage : 385V to 480V,3phaseplus /- 10% Output voltage : 415 V,3 phaseplus /- 2% Battery charger Auto / Manual float cum Boost .The rate shall include overvoltage cutoff , under voltage trip. Online UPS System with 15 minutes battery back-up. 10KVA UPS
55Supply, installation, testing and commissioningof IP Indoor dome styleDeliver 2MP Resolution ,1/2.8 `` 2.13 MPCMOS Sensor Progessive with effective 1945 (H) x 1097(V)pixels ,Video Compresion H.264/H.265/M-JPEG, (Color)/F1.2, 0 Lux (IR On),motorized varifocal lens 2.8 to 12mm , , IR Distance upto 40 mtr, Auto Iris ,Dual Streaming ,Fram rate 25 FPS , motion detection , Ethernet Standard 10/100 Mbps,ONVIF compliance and support 3rd Party NVR/VMS,Power input 12 V DC /POEWall mount,metal body, P66 wheather proff housing with dust proff cable connectors cap as per specification. IK10 Environmental Housing.
56Supply, installation, testing and commissioningofIP outdoor bullet style diliver 2MP resolution, 1/2.8 `` 2.3MPCMOS Sensor Progessive with effective 1920 (H) x 1080(V)pixels,I R megapixel Fixed ,Video Compresion H.264/H.265/M-JPEG, (Color)0.03Lux/F1.2, 0 Lux IR on, ,motorized varifocal lens 2.8 to 12mm ,Advanced Smart IR- Distance upto 50 mtr, WDR minimum )100dB,Auto Iris ,Dual Streaming support ,Fram rate 25 FPS on 1080 MP resolution ,Shutter Speed Auto/Manual, 1/25 - 1/10000, 3D DNR , Motion detection On/Off 4 Zone Polygon , Ethernet port 10/100 Base -T ,ONVIFsupport v2.4,Power input 12 V DC and Power over Ethernet ( No need of additional power cable ) ,Wall mount ,heavy duty metal body, IP66 wheather proff housing with dust proff cable connectors cap as per specification. IK10 Environmental Housing.
57Supply, installation, testing and commissioningof 16 channel NVR with 2 sata connectivity ,support video compression H.264,H.265 and H.265 plus,Support up to 5 MP cameras ,Support Recording resolution 5 MP/4 MP/3MP/1080p/UXGA/720p/VGA/4CIF/DCIF, 16 Ch. live output , Support Audio input , Support upto 25 FPS @ 2 MP and all other resultion also, HDD Support 6 TB each port ,both MPEG 4 and H.264/H.265 recording formats. PTZ support,Tour support ,manual/motion smart recording options, Buzzer ,alaram input/output, Auto maintanace features ,2 Usb 2.0 ports, Remote monitoring software ,Motion detection , power consumoption less than 30 w on full load ,Support all ONVIF cameras . HDMI,VGA Output The NVR with IP connectivity, CMS/WebSoftware with all necessary software .
58Supply Installation of 4 TB HDD complete with all accessories as required Approved Make : Seagate/WD
59Supply and installation of 32` inch LED colour Full HD TV monitor for Live View and Replay of Recorded View
60Supply and installationof 8 port 10/100/100mbps POE switch.
61Supply, Installation, Testing, Commissioning of Intelligent Access Management Softwareshall be designed and configured in such a way so that single point failure will have no degradation in overall functionality,shall have distributed Architecture, shall have both Access and Time Attendance system in single interface and the one database only, ACS software must be integrated with Multiple OEMs Access Controllers and Smart Card Readers, shall support elevator access management
62Supply, Installation, Testing, Commissioning of 10/100 based IP based network access controller shall support integration with Open architecture based software, Capabale to integrate upto 32 nos two (2) reader interface module via RS485 Shall support Card holder capacity: 250000 as minimum and Event buffer in offline mode: 99000 as minimum, UL294, EN 301 489-3 EN 55022 EN 50130-4 (EU), FCC and as per technical specification and with all necessary power supply, battery back-up and Enclosure.
63Supply, Installation, Testing, Commissioning of two reader interface module shall support integration with network based access controller via RS486, can be program as either to protect two doors with a single reader, or in/out reading on a single door, built-in 4 input and 2 output for Door position switch, Request to exit and door lock as minimum, UL294, EN 301 489-3 EN 55022 EN 50130-4 (EU), FCC and as per technical specification and with all necessary power supply, battery back-up and Enclosure.
64Supply, Installation, Testing, Commissioning ofmulti-technology biometric fingerprint, contactless smart card keypad reader with display shall be designed to securely read, interpret, and authenticate access control data from 13.56 MHz contactless smart card credentials and process biometric data from an integrated biometric sensor shall utilize Secure Element Technology to protect keys and cryptographic functions to the international standard Evaluation Assurance Level (EAL) 5 plus . The biometric data encoding, that is protected by, but not limited to, encryption schemas associated with DES, 3DES, or AES-128 methods to provide high security assurance of data integrity, UL294,FCC, CE (EU), WPC (India) certified and specification as per technical specification.
65Supply, Installation, Testing, Commissioning of High Security 8K Contactless smart card can store data for multiple application, shall support multi-layered trusted management of secure identities using the portable Secure Identity Object data model, shall supporttraceable identifiers exchanged during card sessions, preventing data associated to a card from being divulged or cloned. badge must be available under the same technology both for passive 13.56 MHz contactless badges and for virtual badges hosted in smartphones operation via Bluetooth low energy or NFC interface. Support AES-128 bits cryptographic algorithms for data protection and specification as per technical specification.
66Supply, Installation, Testing, Commissioning of door lock suitable for doubleleaf door with holding force of 600lbsspecification.
67`Supply, Installation, Testing, Commissioning of manual call point (green colour) for emergency opening the door.
68`Supply, Laying, connecting and testing of 6 core, 0.75sq.mm multi strand cable to connecting readers to controller . Make : Polycab/RR/Finloex`
69`Supply, Laying, connecting and testing of 2 core, 1 sq.mm multi strand cable to connecting door lock and door sensor to controller Make : Polycab/RR/Finloex`
70Supplying, fixing, testing and commissioning of following patch cord including connections, ferruling etc. as required. Cat 6 Patch Cord 1m -Blue for both end for data and voice
71Supplying, installation, termination, testing and commissioning of following items including connection, numbering, painting etc. as required. Cat 6 24 Port Patch Panel - Loaded
72Supplying, installation, terminations, Testing and commissioning of following server instruments as per technical specification including MS box having Glass door with locking facility at the front with ventilation fans, suitable arrangement forconnectionetc. as required. 12U Rack with Key Board Trey, Mounting Hardware, Cable Manager.
73Supplying, laying, terminations, testing and commissioning of HDMI Cable PVC insulated complete with HDMI female and maleConnector of both side woth suitable size as per site requirment in existing surface / recessedconduit / Racewayas required. 5 Meter
74Supplying, laying, terminations, testing and commissioning of HDMI Cable PVC insulated complete with HDMI female and maleConnector of both side woth suitable size as per site requirment in existing surface / recessedconduit / Racewayas required. 10 Meter
75Supplying, laying, terminations, testing and commissioning of HDMI Cable PVC insulated complete with HDMI female and maleConnector of both side woth suitable size as per site requirment in existing surface / recessedconduit / Racewayas required. 15 Meter
76Supplying, laying, terminations, testing and commissioning of VGA Cable PVC insulated complete with VGA female and maleConnector of both side woth suitable size as per site requirment in existing surface / recessedconduit / Racewayas required. 5 Meter
77Supplying, laying, terminations, testing and commissioning of VGA Cable PVC insulated complete with VGA female and maleConnector of both side woth suitable size as per site requirement in existing surface / recessedconduit / Racewayas required. 10 Meter
78Supplying, laying, terminations, testing and commissioning of VGA Cable PVC insulated complete with VGA female and maleConnector of both side woth suitable size as per site requirement in existing surface / recessedconduit / Racewayas required. 15 Meter
79Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged and lockable door including supply and fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 10 Pair Krone Tag Block
80Supplying, fixing, testing and commissioning of 20 pair telephone MDF consisting of tagblocks in groups of 10pair krone, disconnector type, complete withmetal enclosure powder coated, krone tag block mountingarrangement, telephone distribution chart and locking arrangement (for EPABX).
81Supply, Laying, testing and commissioning of the following multi core 0.60 mm annealed tinned copper conductor PVC insulated and PVC sheathed and overall PVC sheathed armoured telephone cables complete with termination, joints etc complete with all accessories as required. 10 pair armoured riser cable
82Supply Installation Testing and Commissioning of 15` Two-WaySystem in a Trapezoidal Enclosure: 600W @ 8 ohm Continues Power Frequency 45Hz to 20KHzsensitivity 100dB
83Side Wall Speaker Mounting Bracket
84Supply Installation Testing and Commissioning of Two-Way Monitor System 70 Hz - 18 kHz(-10dB) frequency response, 95 dB SPL sensitivity @ 1W / 1m, long term power handling200W, max sensitivity 115dB.
85Supply Installation Testing and Commissioning of Power amplifier, Dual channel 1600plus1600 Watts RMS @ 8 ohms,Sterio powerTHD(0.1%, S/N Ratio 112dB Front-to-rear air ow, temperature controlled speed, Short circuit,open circuit,direct voltage,high temperature, radiofrequency, ultralow frequency, current peak limitery input connector 3-pin XLR, electronically balanced (Loc: Projector Room)
86Supply Installation Testing and Commissioning of24 channels Mixing console with Mono Input 16 Channel, Stereo Input 4 group, Mono Insertion Channel 16 Channel, Phantom power 48V, Frequency Response 20Hz - 20kHz, Channel Crosstalk less than 90dB, S/N Ratio 83 dB, Gain difference between Channel less than 2 dB, Distortion degree less than 0.02%, 21 Kind of DSP Effects.
87Supply Installation Testing and Commissioning of8-channel Phantom Power Microphone/Line input, 8- channel circuit Output: Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD (0.003%, Channel Separation )92dB,Seperate Mute Control each channel, CMRR)80dB, 8 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC, High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable. Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing.
88Supply Installation Testing and Commissioning of 50cm gooseneck cardioid Microphone, table top type polar pattern super heart-shape sensitivity -35dB frequency 60-14Khz output impedance (200Ohm operating Voltage DC9V(At podium)
89Supply, Installation,Testing and Commissioningof handheldWireless Mic system setwith two transmitters dynamic microphone, Frequency Response40Hz-15,000 Hz, Surge mode PLL Phase lock, Dynamic Range )90dB, THD ( 0.5%, S/N ratio ) 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption ( 85mA.
90Microphone Tripod stand with Long Arms of Aluminum
91Supply Installation Testing and Commissioning of Professional DVDplayer make Philips or equivalent
92Supply Installation Testing and Commissioning ofWiring for Speaker 2x1.5sqmm shielded cablesystem including miscellaneous connectors in PVC conduits.
93Supply Installation Testing and Commissioning of Connector accessories.
94Supply Installation Testing and Commissioning of19` Rack Mount 24U Enclosure for Installing all sound reinforcement System and Video Project System
95Supply and fixing 2C x 1.5 Sq.mm shielded Microphone cable
96Supplying, installation, testing and commissioning of Indoor type floor mounted matel clad, 11KV VCB Panel made up of 2.5 mm thick CRCA Sheet with 2Nos. VCB,s (1 Incomingplus1 outgoings) totally enclosed and fully interlocked horizental isolation, draw out type breaker as perIS 13118, as amended up to date and as per additional specifications, having capacities as mentioned below, single break trip free mechanism, manually charged and manullay closing breaker suitable for use on 11KV, 3-Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained fully interlocked, rack out mechanism, air insulated but encapsulated copper bus bar of 630 Amp, capacity , breaker featured with mechanical ON/OF indicator with hand trip device, spring release coil shunt trip coil and auxiliary switch of 4 NOplus4 NC and equipped with following switchgear and accessories i/c connections suitable for 3C x 50 Sq. mm, XLPE 11 KV grade cable (cable entry from bottom), end terminations with heat shrinkable jointing material etc. as required other details shall be as per Technical Specification and SLD.(Extra NO and NC shall be provided through multiplication relay OR through auxiliary contactor). Incoming :- 1Nos. 11 KV, 630 A, VCB , 350 MVA , 18.4 KA for 1 sec. Spring charging Motor voltage 230 V AC tripping /closing coil voltage, 24 /30V/110V DC Current Transformers 3 Nos. - 50/5/5, Core I - 15VA, CL. 1.0 (CT-1) 3 Nos. - 50/5/5, Core II - 15VA, 5P10 (CT-2) Breaker operated auxiliary switch N/O and N/C 1 No. Cast resin type Single Phase PT 11kV /v3 / 110Vv3 , 100 VA , C1.1 Ammeter ( 0-150 Amp) with ASS (96 sqmm) Voltmeter (96 sq.mm)plusVSS 2xO/C plus 1xE/F Relay typeCDG 31 O/C 50%-200%, E/F 20-80% Master Trip Relay VAJH 13 Trip circuit supervision relay –VAX-31 IDMT Relay Control Switch (TNC) Lamps (ON/OFF/ TCH/ Auto trip/ RYB Indication) Spring charged electrical indication lamp. Hooter Trivector meter Emergency push button 1 No. Surge suppressor as per standard fitment of panel manufacturer. 1 No. Grid phase relay to indicate correct phase sequance and trip incoming supply in case of phase reversal. All metering and protection devices, interconnections, necssary control wiring, cabling and all other accessories shall be provided as required as per specifications and technical particulars. Outgoings:- 1Nos. 11 KV, 630 A, VCB , 350 MVA , 18.4 KA for 1 sec. Current Transformers 3 Nos. - 100/5/5, Core I - 15VA, CL. 1.0 CT 3 Nos. - 100/5/5, Core II - 15VA, 5P10CT Breaker operated auxiliary switch N/O and N/C 2 Nos. Auxillary relay for transformer IDMT Relay 2xO/C plus 1xE/F Relay typeCDG 31 O/C 50%-200%, E/F 20-80% Ammeter ( 0-150 Amp) with ASS (96 sqmm) Voltmeter (96 sq.mm)plusVSS Master Trip Relay VAJH 13 Trip circuit supervision relay –VAX-31 Control Switch (TNC) Lamps (ON/OFF/ TCH/ Auto trip/ RYB Indication) Spring charged electrical indication lamp. Emergency push button All metering and protection devices, interconnections, necssary control wiring, cabling and all other accessories shall be provided as required as per specifications and technical particulars. Power pack unit SITC of power pack with 220V AC input and 24V DC continuous output suitable for closing / tripping / indication of HT panel boards with 2 nos. 12V each maintenance free batteries ofsuitable of 100AH each, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter and Voltmeter including connections with 2.5 Sq. mm FR PVC insulated copper conductor cable etc as required.
97250 KVA OIL TYPE TRANSFORMER WITH OLTC Supplying, Installation, Testing and Commissioning of 250 KVA 11/0.433 KV, 3 Phase, 50Hz, Outdoor type copper wound, Oil type step down transformer Dyn11 vector group, oil immersed, natural air cooled, double core type, Class F insulation, connected Delta on HV side and Star on LV side, approximately 4.5 % impedence complete with all modern fittings as given in the specifications including, lifting lugs, wheels, winding temperature indication and alarm, bucholz relay, earthing terminals, diagram and rating plate, explosion vent,ON load tap changer ( plus 5% and -15%) with R.T.C.C. in steps of 1.25% etc. having cable end boxes on HV side suitable for 3 x 50 Sqmm XLPE cable of 11KV grade and cable end box for LT cale arrangement on LV side including supplying and laying of copper conductor multicore armoured control cable from transformer to HT breaker and from transformer to R.T.C. for safety tripping ,suitably mounted on M. S. channel and suitable size foundation as required at sitei/c supplying and grouting of suitable M.S. channelwith all accessories and confirming to IS 11171:1985 and as per specification attached complete in all respects as required at site. Accessories 1. Rating and Diagram Plate 2. Earthing Terminals 3. Earthing Lugs 4. Lifting Lugs 5. OLTC / RTCC / AVR 6. Separate Neutral Bushing 7. HV Cable Box 8. LV Cable Box 9. Winding Temperature Indicator (Scanner Type) 10. Bi - Directional Rollers 11. Marshalling Box 12. M.S Enclousure 13. Surge Arrestors etc.
98HT Cables:- Supply of following sizes of 11kV grade multicore aluminum conductor XLPE armored power cable as per IS: 7098amended up to date as per the following size. 3C x 70 (E) Sq. mm
99MAIN LT PANEL Supplying, Installation, Testing and Commissioning of cubical type LT. panel for415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main LT Panel compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing and Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. Incommers : 2 Nos. 400 A415V, (Ics=Icu=Icw =35 KA for 1 second), 4 Pole, MCCB , Electrically and mechanically interlocked, Micro-processor based release (for over current and Earth fault protections) suitable for communication with RS485 portwith all indications, metering of energy parametrs, push buttons and frame earthing contact, confirming to IS : 13947/3, 1993 as amended upto date complete in all respects as mentioned in specifications / drawing as required:- 96X96MM door mounted front display module showing V, A,PF,KVAR , KWH, Frequencyetc. directly connected to release of ACB with combined accuracy as per IEC61557-12. 8 nos NO/NC contacts for remote opening and closing. Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. 2 set of three phase indicating lamps along with 2A SP MCB backup protection. Spring chargeand DC supply healthy indicating lamp with 2A SP MCB backup protection. 24 V DC Shunt trip coil. Motor wound spring closing mechanism. Control MCB, control terminalsand wiring as required. One Breaker Control Switch Restricted Earth fault relay with 3 Nos. current transformers of 400/5 ratio, 15VA CL.1.0 . Undervoltage, Overvoltage and phase reversal relay for persisted voltage of 105-180% and 20-95% of rated voltage. Bus Couplers: 400 A 415V(Ics=Icu 35 KA for 1 second), 4 Pole, MCCB with inbuilt micro processor based, Electrically interlock with ON / OFF indicating lampsand frame earthing contact, confirming to IS : 13947/3, 1993 as amended upto date complete in all respects as mentioned in specifications / drawing as required:- Each Bus Couplers have 1 Set of ON/OFF indicating lamps . Interlocking: Electrical and Mechanical Interlocking through advance contacts / contactorsin MCCB/ACB`s (Incomers and Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed. Bus bar: 2 Sets of 500 Amp. TPN 35KAaluminum bus bars of suitable length. Bus barshall be insulated by heat shrinkable sleeves and clip on shrounds for joints. Outgoings : (Section-1) Following rated 415V, ACB / MCCB`s shall be microprocessor based with adjustable over current, short circuit and earth fault with time delay and instantaneous protection, all indication, front operatinghandle and door interlock etc. complete in all respects as mentioned in specifications and as required. For each outgoing: 260A, 4P, MCCBwith 35KA breaking capacity - 3Nos. 125A, 4P, MCCBwith 25KA breaking capacity - 2Nos. 63A, 4P, MCCBwith 16KA breaking capacity - 2Nos. 63A, 4P, MCBwith 10KA breaking capacity - 1Nos. Outgoings : (Section-2) 200A, 4P, MCCBwith 25KA breaking capacity - 2Nos. 100A, 4P, MCCBwith 25KA breaking capacity - 3Nos. 63A, 4P, MCCBwith 16KA breaking capacity - 1Nos. 63A, 4P, MCBwith 10KA breaking capacity - 2Nos.
100Supplying, Installation, testing and Commissioning of Automatic Capacitor Control Panel with 100 KVAr capacitors comprising of (1 x 5 KVArplus1 x 10 KVArplus1 x 15 KVArplus 1 x 20 KVArplus 1 x 50 KVAr) unit in a bank formation to achieve Automatic operation. The Panel shall be fabricated out of 2 mm thick sheet steel, dust and vermin proof and channel iron frame work of cubicle construction suitable at 415 volts, 3 phase, 50 HZ AC supply including interconnection, wiring, painting, earthing, labeling and providing danger plates etc. as per specifications Incomer :- 1 No. 260 Amps TPN MCCB 35kA with static release for overload and short circuit protection with fault indication on the release Bas bar : 1 set of 315 Amps TP strips AL. conductorbus bar and links.(BPTM type Heat-shrinkable busbar insulation) One set of (3 Nos.) LED type RYB phase indicating lamps with 2 A SP MCBs for protection. Power factor meter with Automatic P.F.C.R. and CT for unbalanced load - 1 Set. Outgoings. 1 nos 20 amp TP 10 KA MCCB for 5 KVAr 1 nos 25 amp TP 10 KA MCCB for 10 KVAr 1 nos 32 amp TP 10 KA MCCB for 15 KVAr 1 no 63 amp TP 16 KA MCCB for 20KVAr 1 no 100 amp TP 25 KA MCCB for 40 KVAr 1 no 125 amp TP 25 KA MCCB for 50 KVAr Capacitor Duty Contactor 1 no MO C X 5 ,with 1NO plus 1NC Auxilary contacts ,3 ph,400 V ,50Hz for 5 kVAR Rating 1 no MO C X 10 ,with 1NO plus 1NC Auxilary contacts ,3 ph,400 V ,50Hz for 10 kVAR Rating 1 no MO C X 15 ,with 1NO plus 1NC Auxilary contacts ,3 ph,400 V ,50Hz for 15 kVAR Rating 1 no MO C X 20 ,with 1NOplus 1NC Auxilary contacts ,3 ph,400 V ,50Hz for 20 kVAR Rating 1 no MO CX 50 ,with 1NO plus 1NC Auxilary contacts ,3 ph,400 V ,50Hz for 40 kVAR Rating Detuned Harmonic Filters 1 nos. 5 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor 1 nos. 10 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor 2 nos. 15 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor 1 nos. 20 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor 1 nos. 50 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor Miscellaneous items 4nos door switch 4 nos illumination lights with 6 A,10kA MCB ILLUMINATION LED WITH HOLDER and DOOR SWITCH 4 nos 6` dia exhaust fan with thermostat and suitable canopy Internal illumination in Cable alleys with Door operated switch.
101Fabrication supply, installing,testing and commissionand connecting with main LT Panel of indoor type dustand verminproof hingedand lockable doorsatback side made out of 14 SWG CRCA MS Sheet including painting and complete with interconnections,Top entry, cable glands,removableglandplate, plugs, bondingtoearthwith2independent earth connections having2nos 25x6mm GI strip at bottomofpanel as earth bus,theconstruction of panel shall becompartmentalised, very compact, easy in maintenance .provision ofventilation shall be through axial flow fanssystem Legendplate of suitable size of showingpanel no. and name of panel for outgoing feeder and as per the following and as per drawing. LIGHT and POWER PANEL / MDB INCOMER :- 1 No. 125 Amps 4P MCCB 25kA with overload and short circuit protection with fault indication on the release Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set Digital flush type class-1.0 accuracy multifunction meter showing V, A,PF, KWH etc. with 3 Nos. current transformers of 125/5A ratio, 15 VA Class-1.0 metering. - 1 set BUS BSR : 1 set of 160 Amps TPN strips AL. conductorbus bar and links.(BPTM type Heat-shrinkable busbar insulation) OUTGOINGS : 40A, 4P, MCBwith 10KA breaking capacity - 5Nos. 63A, 4P, MCBwith 10KA breaking capacity - 5Nos.
102UPS PANEL / MDB INCOMER :- 1 No. 63 Amps 4P MCB 10kA with overload and short circuit protection with fault indication on the release Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set Digital flush type class-1.0 accuracy multifunction meter showing V, A,PF, KWH etc. with 3 Nos. current transformers of 63/5A ratio, 15 VA Class-1.0 metering. - 1 set BUS BSR : 1 set of 100 Amps TPN strips AL. conductorbus bar and links.(BPTM type Heat-shrinkable busbar insulation) OUTGOINGS : 32A, DP, MCBwith 10KA breaking capacity - 4Nos. 25A, DP, MCBwith 10KA breaking capacity - 1Nos.
103PUMP PANEL INCOMER :- 1 No. 63 Amps 4P MCCB 16kA with overload and short circuit protection with fault indication on the release Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set Digital flush type class-1.0 accuracy multifunction meter showing V, A,PF, KWH etc. with 3 Nos. current transformers of 100/5A ratio, 15 VA Class-1.0 metering. - 1 set BUS BSR : 1 set of 100 Amps TPN strips AL. conductorbus bar and links.(BPTM type Heat-shrinkable busbar insulation) OUTGOINGS : 20A, TPN, MCBwith 10KA breaking capacity - 3Nos. 63A, TPN, MCBwith 10KA breaking capacity - 8Nos.
104ISOLATOR BOX WITH MCCB 400, 4P MCCB, 35KA
105ISOLATOR BOX WITH MCCB 63, 4P MCB, 10KA
106EXTERNAL LIGHT PANEL Design,Manufacture, Supply, Installation,Testing and CommissioningofPanelFabricated out of 16 SWG CRCA sheet steel,IP 54, wall / floor mounting type with rain canopyThe sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. Incoming 1 no. 63 A, 16KA 4P MCCB with Thermal Magnetic based releases, ON indication, 1 no. multifunction meter without RS-485, with selector switch, matching cast resin CT`s. Busbars TPN Aluminium bus bar with heat Shrink Sleeve rated for 100A. Outgoing 3nos 32A DP MCBON indication lamps with 15 nos astronimical time swtich for automaitc switching of landscape light fixtures at sun set and sun rise or twillight ( auto on/ auto off and auto mode)with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 32 A DP MCB - 3 Nos. (Guard room plus Spare) 10 to 16A SP MCB - 20 Nos. (Ex. LightplusSecurity checkplus Boom Barrier) 25 A DP MCB - 2 Nos. 1 Set of control wiring 1 Set of designation plates Danger notice plate 1 no.
107Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx4 sq.mm
108Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx10 sq.mm
109Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx16 sq.mm
110Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx25 sq.mm
111Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx35 sq.mm
112Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx50 sq.mm
113Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx120 sq.mm
114Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx185 sq.mm
115Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx240 sq.mm
116Supplying of following sizes of 1.1 KV grade multicorealuminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 1Cx16 sq.mm CU Un. Ar.
117Supply of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects. Control cable 10 core 2.5 Sq.mm
118Supply of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects. Control cable 12 core 2.5 Sq.mm
119`Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required` Upto 35 sq. mm (clamped with 1mm thick saddle)
120`Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required` `Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)`
121`Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required` `Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)`
122`Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required` Upto 35 sq. mm
123`Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required` Above 35 sq. mm and upto 95 sq. mm
124`Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required` Above 95 sq. mm and upto 185 sq. mm
125`Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required` Above 185 sq. mm and upto 400 sq. mm
126Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / cable trench as required. Upto 35 sq. mm
127Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / cable trench as required. Above 35 sq. mm and upto 95 sq. mm
128Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / cable trench as required. Above 95 sq. mm and upto 185 sq. mm
129Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / cable trench as required. Above 185 sq. mm and upto 400 sq. mm
130Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4Cx4 sq. mm (25mm)
131Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4 X 10 sq. mm (25mm)
132Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4 X 16 sq. mm (28mm)
133Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4 X 25 sq. mm (28mm)
134Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 35 sq. mm (32mm)
135Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 50 sq. mm (35mm)
136Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 120 sq. mm (45mm)
137Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 185 sq. mm (57mm)
138Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 240 sq. mm (62mm)
139Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 1Cx16 sq.mm
140Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 150 mm width X 50 mm depth X 1.6 mm thickness
141Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 300 mm width X 50 mm depth X 1.6 mm thickness
142Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 600 mm width X 75 mm depth X 2.0 mm thickness
143Supplying, Installing, Testing and Commissioning at site of automatic mains failure control including auto by-pass panel, suitable for 250 KVA silent type Dg set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH and provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the folloewing and as per specification.:
144SUB HEAD VII : SUPPLY OF EXTERNALLIGHTINGSYSTEM Supplying and fixing integral post top lantern with 40 watt LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3 W each assembled on single MCPCB, having color temp 6500K and having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy)80lm/W. LED driver PF 0.95 and surge protection 2KV.The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer and LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.
145Supplying, fixing and testing of approved make of integral type bollard cyclindrical shape housing cast aluminium dome shape top cover fixed with cylindrical shape poly carbonate cover having base plate with holes for direct mounting complete with all accessories and control gear box (with 1x 10watt LED lamp) including preparatoion of foundation including fixing with connection and all required material as require
146Supply, Installation, Testing and Commissioning of 45 Watt Solar Street Light luminaire with inbuilt SCC made IP66 and with MPPT (Maximum Power Point Tracking) which provides about 25% more charging efficiency by utilizing maximum energy harvested by solar PV modules. System should designed to withstand highly corrosive atmosphere and heavy wind loads. The modules are certified for industry standards IEC61215, IEC61730 (safety class 1 and 11), IEC61701 along with 8 Mtr. octagonal pole with 200 (100x2) AH lead acid battery and 240 (120x2) Wp solar panel Total lumen output should not less than 6300 lumen Complete with all Accessories and Control Gears etc.
147Supply, Installation, Testing and Commissioning of 202x238x111 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with cable hinged cover of approved design complete having gasket of internally embedded and made of polyeutherene and should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes and provision for mounting din rail. with 2 Nos cable gland including supplying and fixing crimping 2 nos lugs and 1 nos 32A connector 6 way for looping the incoming and outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required
148Supplying of 8 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 135 mm dia (A/F) made out of 3mm sheet with MS base plate of size 225mm (NS) x 225mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size openinginside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB and neutral link4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing and laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement and J typefoundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required.
149Supplying, Drawing, Connecting and Testing of Following Size of PVC Insulated FRLS Copper Conductor (as per IS : 694) flexible Multicore Wire in the existing poles and bracket from cable termination connector / MCB to the fitting i/c providing suitable connectors 3 core 2.5 sq.mm
150Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required 300 mm dia
151Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 63 mm dia (OD-63 mm and ID-51 mm nominal)
152Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 90 mm dia (OD-90 mm and ID-76 mm nominal)
153Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 120 mm dia (OD-120 mm and ID-103 mm nominal)
154Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 4.5 meter and upto 8.5 meter
155Supplying , fixing, testing and commissioing of Upvc Rain water water pipesSWR Type - A to IS : 13592 ringfit `O` ring with Polypropelene ring co-moulded with Termo Plastic Elastomer (TPE) technology providing 100% leak proof joints inclusive of all necessary specials manufactured fittings selfit/ringfit conforming to IS:14735, likes bends, tee, offsets, door bends or tees, bends, junctions, cowls, threaded type cleanout, etc. Laid under floor/ fixed on walls and in pipe shaft with proper pipe support like brackets, hangers, GI grip bolts, etc. complete. The support shall be painted with two coats of enamel paint. 160 mm dia Pipe
156Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on gyeser and solar water pipesuitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm
157Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-16). 15 mm dia nominal bore
158Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-16). 20 mm dia nominal bore
159Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-16). 25 mm dia nominal bore
160Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in iverhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. 50 mm dia NB Float Valve
161Solar Water Heaters Supply, erection, testing and commissioning of solar water heating system with following details : System temperature output : 60 degree C (during clear sunny days) System type : Thermo syphon System : Non Pressurised Application : Bathing / Washing / Cooking Type of Solar Collectors : Copper tube Flat Plate Collectors as per BIS with following specifications - Size of Collector : 2080 x 1070 x 100 mm Number of Collector : To suit system requirement. Absorber area : 2 sq M Type : Cu - Cu Weight : 46 Kg (Dry) Absorber Coating : Selective - NALSUN Absorbivity : ) 0.95 Emissivity : ( 0.2 Frame Material : 16 SWG extruded Aluminium Glazing : Toughened Glass Glass beeding : EPDM Finish : Painted by approved shade Eelectrical element and control panel Hot water return pump Hardware : SS 304 Insulation : PUF Collector Stand : 35x35x3 mm MS angle `Hot Water Tank : Cylindrical - vertical / horizontal, Stainless steel 304 grade with 100 mm thick Rock Wool insulation including 22 SWG aluminium cladding. ` The entire system should be complete with internal piping in G.I. (class B) with 50 mm rock wool insulation of density 48 kg/m3with 26 SWG Al cladding, necessary isolation valves, Y type CI strainer, hardwares, temperature gauge of range 0 - 120oC, water meter, MS angle iron structure of min thickness 3 mm duly paintedetc as required to complete the system in all respects. The entire system should be approved by BIS as per IS : 12933 and as per local regulations. System Capacity : 600 liters ( storage tank of 600 litres ) per day (LPD) having 6.0 collectors.
162Domestic WaterTransfer Pump set Providing, fixing, commissioning and testing package vertical Domestic water transfer pumps, comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects. Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C supply and shall be having the following requirement complete with foundation and associated civil works. Suction and Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Suction and delivery header including all pipes, suction and delivery sides valves, NRV, Pressure gauges and accessories complete. Flow Rate: 2.0 LPS (1 workingplus1 stand by) Head :40 M Min. Motor HP :2.5 H.P. (Each) INCOMER 32 A TP MCCB with heavy duty solid neutral link with (0-32A) ammeter with 3 CT and selector switch, (0 - 500 V) voltmeter with selector switch, phase indication light withprotection fuse. - 01 Set OUTGOINGS For 2 x 2.5 HP Filter Feed Pumps 25 A TP MCB with 12 A DOL starter, overload relay, 96 mm (0-25A) ammeter with single CT, start / stop push buttons, on / off / trip indication lights with protection fuse, single phase preventer. - 01 set.
163Sump Pumps Supply and Installation, testing and commissioning of centrifugal non clogging submersible sump pumps for plant room drainage. Pump capable capable of handling 25 mm dia soft solids. Motor suitable for 415plus10% volts, 3 phase, 50 Hz AC Power supply. Pumps shall be suitable for automatic/manual operation (Overall depth of sump – 1.5 M). Submersible sump pump shall be provided with dry running protection. Inclusive of supporting arrangement for stationary type. Two nos. of pump installed in one sump pit 1 working and 1 standby with automatic/manual opration as requireds and panel. Waste Water Drainage Sump Pump (PLANT ROOM ) Flow rate:2.0 LPS Head : 10 Mtrs. Min. Motor HP : 1.5 (Each) INCOMER 32 A TP MCCB with heavy duty solid neutral link with (0-32A) ammeter with 3 CT and selector switch, (0 - 500 V) voltmeter with selector switch, phase indication light withprotection fuse. - 01 Set OUTGOINGS For 2 x 2.5 HP Filter Feed Pumps 25 A TP MCB with 12 A DOL starter, overload relay, 96 mm (0-25A) ammeter with single CT, start / stop push buttons, on / off / trip indication lights with protection fuse, single phase preventer. - 01 set.
164Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required.
165Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
166Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required.
167Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required. Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam)
168Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 5C x 1.5 Sq. mm
169Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
170Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 30 m
171Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
172Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Providing and fixing of standard short size GM branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked and TAC approved.
173Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
174`Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.`
175Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm dia.pipe
176Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia
177Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
178Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 nominal bore (class C)
179Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm nominal bore (class C)
180Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (class C)
181Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm nominal bore (class C)
182Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm nominal bore (class C)
183Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm nominal bore (class C)
184Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm nominal bore (class C)
185Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming toIS 15683, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 4.5 kg
186Providing and fixing (ABC Dry Chemical Powder ) type Fire Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket complete with internal charges. Capacity 6 Kg.
187Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings and accessories. The door shall have a front glass with lock and key arrangement and shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor).
188Providing and fixing of TAC approved 1.6mm thickM.S. fire hose cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings and accessories. The box shall have a front glass door with lock and key arrangement and shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
189Providing and fixing of Fire Axe
190OUTDOOR UNITS (HEAT PUMP TYPE) `Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSite basis)` Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto49°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: Cost of R 410 A Gas should be inclusive The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with oxycoat (Epoxy coating followed by oxycoat(PU /Polysiloxine) Coating. The Vendor should considere the deration on ODU election as per Greater Noida Ambient conditions 24 HP Outdoor unit VRV/VRF Zone-01
191Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSite basis) Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto49°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: Cost of R 410 A Gas should be inclusive The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with oxycoat (Epoxy coating followed by oxycoat(PU /Polysiloxine) Coating. The Vendor should considere the deration on ODU election as per Greater Noida Ambient conditions 18 HP Outdoor unit VRV/VRF Zone-02
192Supply, installation, testing and commissioning of following Wall Mounted /Cassette type units with panel and inbuilt drain pump/slim Ceiling Mounted duct type/Ceiling Mounted Built in type/Ceiling Mounted Ductable type units VRF Air Conditioners with cordless/corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within theIDU (evaporator unit) shall be coated with polysiloxane based coating, The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. Ceiling Mounted HSP Ductable Unit 2542-2825 CFM / 8.0-8.02 TR
193Supply, installation, testing and commissioning of following Wall Mounted /Cassette type units with panel and inbuilt drain pump/slim Ceiling Mounted duct type/Ceiling Mounted Built in type/Ceiling Mounted Ductable type units VRF Air Conditioners with cordless/corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within theIDU (evaporator unit) shall be coated with polysiloxane based coating, The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. Wall Mounted Unit 300-310 CFM / 1.0-1.02 TR
194INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted /Cassette type units with panel and inbuilt drain pump/slim Ceiling Mounted duct type/Ceiling Mounted Built in type/Ceiling Mounted Ductable type units VRF Air Conditioners with cordless/corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within theIDU (evaporator unit) shall be coated with polysiloxane based coating, The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. Wall Mounted Unit 400-425 CFM / 1.28-1.30 TR
195REMOTE CONTROLLERS Supply, installation, testing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHU`s.
196Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of touch screen controller (Which is controlled 110 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. Supply, installation, testing and commissioning of touch screen controller (Which is controlled 20 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.
197REFNUTS / Y-JOINTS Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints withpolysiloxane based coating
198REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 06.35 mm with 13 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
199REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 09.52 mm with 13 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
200REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 12.70 mm with 13 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
201REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 15.88 mm with 13 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
202REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 19.05 mm with 13 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
203REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 22.22 mm with 19 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
204REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 28.58 mm with 19 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
205REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation betweeneach setofindoor andoutdoorunits asper specifications,all piping inside the room shall be properly supported with hangersand? All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 34.92 mm with 19 mm thick cross linked closed cell XLPE/Nitrile Rubber insulation
206TRANSMISSION and CONTROL WIRING Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM
207TRANSMISSION and CONTROL WIRING Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. Perforated GITray with hangers and supports for copper piping (250 mm wide)
208CONDENSATE DRAIN PIPE Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with kinny foam and vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 40mm dia
209Refrigerant-410a Supply , charging and Leackage testing of refrigerant -410a in additionalcopper piping circuit.
210CONDENSATE DRAIN PIPE Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with kinny foam and vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 30mm dia
211CONDENSATE DRAIN PIPE Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with kinny foam and vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 25 mm dia
212Propeller fan Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver and bird screen and Speed Regulator. 200 mmdia propeller fan,with single phase motor
213Propeller fan Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver and bird screen and Speed Regulator. 300 mmdia propeller fan,with single phase motor
214Propeller fan Supply, installation, testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver and bird screen and Speed Regulator. 450 mmdia propeller fan ,with single phase motor
215Inline fan Supply, installation, testing and commissioning ofCertified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulatorof the following capacity of approved make and specification. 300-500 CFM,5-7 mm SP WG with Single phase motor
216Tube Axial Flow fans SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 1450 RPM respectively Normal/Smoke case. SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model and AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H` insulation. Motor shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs. Fan shall be EN 12101-3 Certified and CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule ). 3500 CFM, 30 mmwg SP For Smoke extract
217Tube Axial Flow fans SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 1450 RPM respectively Normal/Smoke case. SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model and AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H` insulation. Motor shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs. Fan shall be EN 12101-3 Certified and CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule ). 4000 CFM, 30 mm wg SP For Smoke extract
218Tube Axial Flow fans SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 1450 RPM respectively Normal/Smoke case. SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model and AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H` insulation. Motor shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs. Fan shall be EN 12101-3 Certified and CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule ). 11500 CFM, 30 mmwg SP For Smoke extract
219PHI Cell Supply, installation, testing and commissioning of duct mounted air purification system. PHI Cell based on advanced oxidation technology with broad spectrumUV Lamp ( 100-380 NM) enhanced on the quad metalic compound target /hydratedcatalytic matrix cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions and duly enclosed by a poly casing tube that should prevent glass or mercuryleakage into the conditioned/served space.The PHI cell should be capable to reduce microbial, viral and spores contamination and VOC’ and odors. The UV lamp must be enclosed in a poly casing to prevent accidental spill of mercury in HVAC duct. The PHI cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed. Length selection should be per duct piece in which is to be installed.Detailed selection chart to be furnished indicating the model number for each unit. Cells Should be complete with Transformers, control cabling and Plug Top and necessary power cable vendor to comply all Tender Specifications. Suitable for various ranges. 1,000 to 3000 CFM,24 VAC, 0.6 amps, 14 watts ,9” probe, 5.5” dia. Plate
220AIR CURTAIN Supply,installation testing and commissioning of AIR CURTAIN of following size as per approved make and with Door limit switch/sensor with multi speed regulator .(At ground entrance) 1500 mm long (High flow type)
221AIR CURTAIN Supply,installation testing and commissioning of AIR CURTAIN of following size as per approved make and with Door limit switch/sensor with multi speed regulator .(At ground entrance) 2100 mm long (High flow type)
222SITC of Dehumidifier (Portable)with Rotary compressor and suitable R-410a and reqd. control accessories of 60 ltr capacity for Swimming Pool
223Site Fabricated Duct - GI duct Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing shall be adequately secured and supported in an approved manner, with Threaded Rod and RapidStrut Slotted channel formed of Pre-galvanized steel support method under ducts at no greater than 2 meter span. All vertical duct work shall be supported by suitable RapidStrut Slotted Channel along with BIS 2x1 hole 90deg connector and BIS wall plate and anchor fastener at structural members on each floor slab. For Non Fire Rated Duct support shall be through anchor fastener driven into the concrete slab by electrically operated gun. Rigid support must be used in conjunction with Threaded Rod and RapidStrut Slotted channel supports with duct work at each change of direction or connection. All Support System shall be in accordance with the approved shop drawings and as required by the specifications 0.63mm (24 gauge) GSS
224Site Fabricated Duct - GI duct Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing shall be adequately secured and supported in an approved manner, with Threaded Rod and RapidStrut Slotted channel formed of Pre-galvanized steel support method under ducts at no greater than 2 meter span. All vertical duct work shall be supported by suitable RapidStrut Slotted Channel along with BIS 2x1 hole 90deg connector and BIS wall plate and anchor fastener at structural members on each floor slab. For Non Fire Rated Duct support shall be through anchor fastener driven into the concrete slab by electrically operated gun. Rigid support must be used in conjunction with Threaded Rod and RapidStrut Slotted channel supports with duct work at each change of direction or connection. All Support System shall be in accordance with the approved shop drawings and as required by the specifications 0.8 mm (22 gauge)GSS
225Factory Fabricated Duct - GI duct Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing shall be adequately secured and supported in an approved manner, with Threaded Rod and RapidStrut Slotted channel formed of Pre-galvanized steel support method under ducts at no greater than 2 meter span. All vertical duct work shall be supported by suitable RapidStrut Slotted Channel along with BIS 2x1 hole 90deg connector and BIS wall plate and anchor fastener at structural members on each floor slab. For Non Fire Rated Duct support shall be through anchor fastener driven into the concrete slab by electrically operated gun. Rigid support must be used in conjunction with Threaded Rod and RapidStrut Slotted channel supports with duct work at each change of direction or connection. All Support System shall be in accordance with the approved shop drawings and as required by the specifications 0.63mm (24 gauge) GSS
226Factory Fabricated Duct - GI duct Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing shall be adequately secured and supported in an approved manner, with Threaded Rod and RapidStrut Slotted channel formed of Pre-galvanized steel support method under ducts at no greater than 2 meter span. All vertical duct work shall be supported by suitable RapidStrut Slotted Channel along with BIS 2x1 hole 90deg connector and BIS wall plate and anchor fastener at structural members on each floor slab. For Non Fire Rated Duct support shall be through anchor fastener driven into the concrete slab by electrically operated gun. Rigid support must be used in conjunction with Threaded Rod and RapidStrut Slotted channel supports with duct work at each change of direction or connection. All Support System shall be in accordance with the approved shop drawings and as required by the specifications 0.8 mm (22 gauge)GSS
227Grilles/Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium supply air grilles with damper.
228Grilles/Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium return air grilles without damper.
229Grilles/Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium return/exhaust airValve circular/squirell diffuser without damper.
230Fresh Air/Exhaust Air Louvers Supplying and fixing ofextruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. Fresh Air/Exhaust Louvers
231MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in supply air duct/main branch andreturn air path as and where required of required size i/c control wiring ,the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of at least 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections. The fire damper shall be complete with electronic temperature sensor and electrically operated actuator .The fire dampers shall be located in the supply/return air ducts, at all fire rated crossovers (shafts/walls etc.) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection / HVAC and shall trip/close in the event of fire / smoke in the respective zone . Bare Fire Dampers with 400 mm sleeve
232MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/main branch andreturn air path as and where required of required size i/c control wiring ,the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections.The fire damper shall be complete with electronic temperature sensor and electrically operated actuator .The fire dampers shall be located in the supply/return air ducts, at all fire rated crossovers (shafts/walls etc.) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection / HVAC and shall trip/close in the event of fire / smoke in the respective zone . Control panel actuator , including Electrical, spring type actuator, remote indication of the fire damper position.
233MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/main branch andreturn air path as and where required of required size i/c control wiring ,the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections.The fire damper shall be complete with electronic temperature sensor and electrically operated actuator .The fire dampers shall be located in the supply/return air ducts, at all fire rated crossovers (shafts/walls etc.) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection / HVAC and shall trip/close in the event of fire / smoke in the respective zone . Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers.
234MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/main branch andreturn air path as and where required of required size i/c control wiring ,the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections.The fire damper shall be complete with electronic temperature sensor and electrically operated actuator .The fire dampers shall be located in the supply/return air ducts, at all fire rated crossovers (shafts/walls etc.) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection / HVAC and shall trip/close in the event of fire / smoke in the respective zone . Sealing the openings around the sleeve of thefire dampers with approved fire sealant, as per the recommendations of the manufacturer and specifications.
235Supply, Installation, Testing and commissioning of doble layer canvas connection (Fire retardent) asper specification.
236MECHANICAL INSULATION DUCT LINE ACOUSTIC TREATMENT `Supply and installation of cross linked open cellFoam/XLPE/Nitrile Rubber Acoustic insulation on ducts having density of 30 to 60Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C toplus 100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke and Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 15mm thickAcoustic open cell insulation on one side for Duct acoustic insulation
237DUCT LINE THERMAL INSULATION `Supply and installation of cross linked closed cell Foam/XLPE/Nitrile RubberThermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C toplus 100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke and Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. ` 25 mm thick insulation with Two layer 7 mile cloths with adhesive onsupply/Return/Exh.air duct on exposed area
238DUCT LINE THERMAL INSULATION `Supply and installation of cross linked closed cell Foam/XLPE/Nitrile RubberThermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C toplus 100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke and Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. ` 13 mm thick insulation
239DUCT LINE THERMAL INSULATION `Supply and installation of cross linked closed cell Foam/XLPE/Nitrile RubberThermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C toplus 100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke and Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 9mm thick insulation
240EXPOSED ROOF INSULATION Supply and installation of cross linked closed cell Foam/XLPE/Nitrile RubberThermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C toplus 100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke and Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 19mmthick oxide acetate insulation for underceck plain
241ASSOCIATED ELECTRICAL WORKS `Therates for the distribution boards from the Breakers and instrumentsshall also include the following :` Wiring forlight / Fan points with 1.5 sq. mm PVC insulatedcopper conductor1100 Volt grade strandedflexible FRLS wiresofapproved makein1.6mmthick25mmdiaMS conduitincluding costof providing and fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a6 amp240Volt ModularPlatetypeswitchesof approved quality,colour, makeanddesign with mouldedcover platein zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete `TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.` All MCB’s shall be of minimum 10 KA breaking capacity and MCCB `s shall be not lessthan 25KA `The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermalmagnetic microprocessorreleasesas per BOQ and following :` i.MCCB rating upto 250 Amps with thermal magnetic releases. ii. MCCB above 250 Amps with microprocessor releases. `All MCB’s used for protection ofresistiveand lightlyinductive loadshallbetype “B”characteristic and inductive(motor)load shall be of type “C” characteristic.` `Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.` i.IP 42 for indoor panels. ii. IP 55 for ODU panel. `AllMCCB’sshall beprovidedwithoperatingmechanismfordoor interlock.` `All hinged door shall be earthedthrough2.5 sq mm tinnedbraided copper wire.` `Providing cableclamps/ supportswithin distributionboardscable alley.` `Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.` `Model, current capacity location and frame size of switchgear shall be writteninside of thepanel doors with paint / permanent marker as approved shop drawings / site requirment.` All meter shall be digital type and all starter shall be as per Type-2 Coordination chart Current Transfomer shall be resin cast. All Panel Shall be BMS Compitable Spcl. Note: All Panels, Cable tray,Power Cable etc.Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes andHangers, Supports and Modular system – Wire rope Supports(double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications Floor Mounted Panels with base frame (Min. 75 mm ) Plant/AHU/Fan Panel Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire.All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. ODU`s Panel-MCC-01 (Terrace) Same as above item but outdoor Panel with following accessories. INCOMING: 1 No. 100 amps, 415VTPN MCCB with overcurrent and short circuit releases, all indication, push button etc. Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set (0 - 100 A) CT operated Ammeter with selector switchand 3 nos. CTs ratio 100/5A , 15VA burden and accuracy class of 1.0 - 1 set 0-500 V Voltmeter with selector switch - 1 set BUSBAR: 125 Amp. TPN, 35 kA Al. Bus Bar OUTGOINGS: 80A, TPN ELCB with 100mA- 2 Nos. (Incl. 1No. Spare) 40A, TPN ELCB with 100mA -03 Nos. (Incl. 1No. Spare) ODU Panel Described as above/As per Manufacturer ODU Configuration.
242Ventilation and Smoke Fan Panel HVAC Fan Panel MCC-02 to 03 (GF and 1st) Incoming 1 no. 20 amp MCB Phase indicating lights with control fuses. Breaker ON/OFF/TRIP indicating lights. Bus Bars 32 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. Outgoings 2 nos. 2.5-4.0 A,TP MPCB (with DOL starter ) Panel as described above and in drawings.
243HVAC Fan Panel MCC-01 (Terrace) Incoming 1 no. 125 amp MCCB Phase indicating lights with control fuses. Breaker ON/OFF/TRIP indicating lights. Bus Bars 150 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. Outgoings 6 nos. 9-14.0 A,TP MPCB (with DOL starter ) Panel as described above and in drawings.
244CABLING (POWER ) Power Cabling and Earthing: Spcl. All Cables Should be fire survival Cables Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 3Cx 06 Sqmm
245CABLING (POWER ) Power Cabling and Earthing: Spcl. All Cables Should be fire survival Cables Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 3Cx04 Sqmm
246CABLING (POWER ) Power Cabling and Earthing: Spcl. All Cables Should be fire survival Cables Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 2Cx04 Sqmm (Cu Conductor)
247CABLING (POWER ) Power Cabling and Earthing: Spcl. All Cables Should be fire survival Cables Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 4Cx06 Sqmm
248CABLING (POWER ) Power Cabling and Earthing: Spcl. All Cables Should be fire survival Cables Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 4Cx04 Sqmm
249Control Cabling Supply, installation, testing and commisioning ofCopper conductor , PVC insulated, Fire survival cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU toPanel). 8C x 1.5 Sqmm
250Sand Filter Supply Sand Filter manufactured with fiber glass and polyester resin,UV resistance surface, Non Corrosive material,complete with 6-way multiport valve with filter connection / Inter-Connecting Piping, Pressure gauge, water drain/empty drain for filter and Required Sand Media. Connection 160 mm Design @140000 ltrs/per /hr. Filter Area: 33 Sqf. Diameter2000mm ( Side Mounted ) Filter Velocity :35 Cum/mtr. Working Pressure : 2.5 Kg Bar
251Front Line Valve Battery Support Supply of valve Battery Manifold made in PVC with flanges for connecting to filters as per DIN 2501 standards. Consists of set of 5 - buttterfly valves for carrying out filtration, back-washing, rinsing and shut down of the filters. Size : 150mm 5 x Butterfly valve and pipe fittings 200mm VB with 2nos pipe support
252ValvebatterysupportsmadeinZincPlatedSteel.Height:2.30m,EasyAssemblyValve Manifold Brackets from63mm dia - 225mm for all filter types
253Supply Of silica sand media for filter with granulometry between 0.4 to 0.8 mm i/c filling it into the filtration plant etc. Complete a required.
254Supply Of gravel for filter with granulometry between 1-2 mm i/c filling it into the filtration plant etc. Complete a required.
255Commercial SeriesRecirculation Pump 10 HP Horizontal multistage self priming centrifugal pumping set each of capacity 125 cum/hr of10 HP, Single Phase, ofwith prefilter, glass filled thermoplastic protection and automatic reset A.C. electric supply complete with enclosed fan cooled motor, barrel union 100/65 mm, suction stainers and necessary valves complete for drawing water from raw water tank and supply to treatment plant. complete in all respect. Head 15mtr Hp10.0, ( Three Phase )
256Supply of Chemical dosing pump, 20LPH@5Bar Capacity0-10 litres/hr. Head35 M
257500 Ltr Plastic Round Chemical dosing tank
258Stirrer 900mm Long 900 Manual stirrerfor chemical dilution
259UV Disinfection Advantage: UV pool sanitizers are popular for more than just their ease of use. They also kill off harmful microorganisms and parasites,reduce your dependence on pool chemicals,eliminate harmful chlorine by-products and use very little electricity.All of this comes together to make a pool that`s simply healthier. Scientists know that chlorine and other chemicals used in pools can exacerbate allergies.
260Stainless Steel Drain Chanel 9` Supply ofStainless steel drain grating plate made out of 304 quality sswith suitable supporting Chanel and of following sizesof required size for drainout chamber.
261Inlet Nozzle Supply of Flow adjastable ABS inlet nozzles UV treated with S.S. screws to fit in the 2` PVC pipes
262Wall Conduit Supply of 2” wall conduit of pvc for concrete pools, 300 mm long, rear side 2“ external thread, color: grey/ White
263Overflow ABS Grating Supply ofSupply ofStainless steel drain grating plate made out of 304 quality sswith suitable supporting Overflow Chanel and of following sizesGrating, width:400 mm ( 16` )
264uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 63 mm dia
265uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 75 mm dia
266uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 90 mm dia
267uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 110 mm dia
268uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 160 mm dia
269uPVC pipes All the pipes and fittings For main pool are PVCu. These pipes are designed to handle a pressure of 10 bar and the fittings are capable of handling a pressure of 16/10 bar. These all are high rated to handle burst pressures even though the system works at 2.5 bar. 200 mm dia
270NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Ball Valve 110mm (4`)
271NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Butterfly Valve 160mm (6`)
272NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Butterfly Valve 200mm (8`)
273NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Foot Valve 200mm (8`)
274NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Sluice Valve 200mm (8`)
275NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Check Valve 160mm (6`)
276NecessaryBall Valve and Butterfly Valve , Non return valve Providing and fixing Pvc lever operated ball valve of full flow with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 with union, flanges where as required. Flanges and Nut-blot
2775.Cleaning and Maintenance Equipment`s `Moveable Trolley for Vacuum System.Features : Durable SS304 Easily moveable with required cleaning kit. Low cost`
2785.Cleaning and Maintanance Equipments Self priming centrifugal pumping set each of capacity 11 cum/hr of 3 HP, Single Phase, of with prefilter, glass filled thermoplastic protection and automatic reset A.C. electric supply complete with enclosed fan cooled motor, barrel union 50 mm, suction stainers and necessary valves complete for drawing water from raw water tank and supply to treatment plant. complete in all respect.
2795.Cleaning and Maintanance Equipments Supply ofMetallic Suction Head 800mm with 2` Connection and trailing cable,
2805.Cleaning and Maintanance Equipments Supply of30 mtr Vac Hose, EVA, doudle grip flexible with standard cufff link, 38 mm.
2815.Cleaning and Maintanance Equipments Supplying of Heavy duty deep net with 5 Micron net, clip in fastening- Dark Blue
2825.Cleaning and Maintanance Equipments Supplying of9Mtr. Telescopic pole with Economy handgrip and clipin fastening- Ribbed- Silver colour
2835.Cleaning and Maintanance Equipments `Supplying of 3 way Test kit ( PH/ CL/ BR)`
2845.Cleaning and Maintanance Equipments 450mm deluxe curved type nylon wall brush,clip in fastening- Light Blue
285Supply Of Necessary fixing accessories with electrical equipments required for system installation.
286Underwater Lights Warm White Warm White Single Colour Microprocessorbased Under Water LED Lights 12 V, 32 Watt , IP 68, Size :- dia 266.mm, height 12` ABS Body, with Stainless steel Gland for double insulated 2.5mm dia cable Light should be fully waterproof when immersed in water with Excellent Finishing . Complete in all respects.
287Light Niche Body `Large stainless steel niches are formed with brass fittings. All niches have internal and external grounding lugs for use with either metal or PVC conduit.`
288Power Supplyfor the required capacityof LED Light . Completein all respect
289Deck Box Supply of ABS white plastic deck.
290ELECTRICAL CONTROL PANEL Design, Manufacture, Supply of Control panel constructed out of 2mm thick MS sheet steel fabricated cubicle type panel, dust and vermin proof complete with hinged and lockable doors. The MS sheet steel shall undergo a rigorous 7 tank sheet metal treatment process and duly powder coated as per specifcation. The panel shall be complete incoming MCCB/ MCB,suitable size Aluminium busbars, bus link complete with direct on line starter/ star delta starter with` hand `` off ` automaticmode selection switch with Ammeter for each motor, timer, Auto manual switch, earthing connector etc as required.Panel CPRI approved .
2917. Pool Equipment Overflow Ladder - 3Steps With Anti slip SS Threads SS 304, 42mm ( ASOFF4)
2927. Pool Equipment Overflow Ladder - 5 Steps With Anti slip SS Threads SS 304, 42mm ( ASOFF5 )
293Anchor Cup SS 304 Grade Totally Rust proof Anchor Cup
2949. Supervision and Installation Designing, installation, testing and commissioning of equipment
2951. Competition Equipments Starting Block `Made of Stainless Steel Sheet with non slip top of size 50 cm X 50 cm with Stainless steel hand grips for back stroke. As per FINA specification height of the Starting block is 400 mm . Starting blockweight is 25 kg approx and Sheet Thickness is 2.5 mm.`
2961. Competition Equipments Rope Tightner SS Rope Tightner For Racing Lane
2971. Competition Equipment`s Snap Hook SS Snap Hook For Racing Lane
2981. Competition Equipments Racing Lane Lane Rope in 25 M length - with 5.5” diameter Anti wave floats with floating supports tied in a SS rope 3mm
2991. Competition Equipments Lane Roller Heavy-duty swim racing lane storage reels are made from SS-304 stainless steel and feature zinc plated locking casters that swivel 360 degree. They are alsoavailable with all stainless steel casters.
300False Stoke MARKER
301Backstroke turn indicators Supply of Back stroke indicator post of SS316 with installation kit
302GBB, 123.7 kW,Three Phase,380-415V/50Hz/3ph Tropical Heat/chill pump `A Real Commercial Sized Heat Pump that Heats and Cools Large Commercial Swimming Pools Up to a Half Million BTUs in One Single Unit ThermoLink® Titanium Heat Exchanger Patented counter-flow water management system Heats water faster and more efficiently Impervious to chemical corrosion Durability without sacrificing performance Lifetime warranty Microprocessor Controlled with LCD Digital Display New SMART control panel with 24 character full-text display provides easy-to-read menu options and unit status On-board self-diagnostics Microprocessor controlled defrost cycle Corrosion Resistant Cabinet Rust resistant, heavy gauge G90 Galvanneal steel with 7 step Powder Coat process ElectroFin® epoxy polymer coated evaporator coils Polymer condensate drain system Polymer coated fan guards ICEBREAKER® Heat and Cool`
303PoolLife Safety Equipment`s `LIFE BUOY (RING ) : Color : Red Material : PVC Water Rescue Life Saving The floating ring is specially for life saving rope, to form a complete set of life-saving equipment`
304PoolLife Safety Equipment`s `Life Guard Chair : Stands 6` From Deck Surface. 100% Non-corrosive Deck and Steps. Portable For Easy Storage and Better Visibility. Life Ring Hook and Umbrella Holder Included. 38 Mm Od. Constructed In Stainless Steel-304. Diameter: 38 mm.`
305PoolLife Safety Equipment`s Shepherd`s Crook (Hook ) andTele Pole4.8m :The double hook shepherd`s crook is excellent for poolside and beachfront rescues. Mounts to standard straight rescue poles. And telescoping reaching pole is made from anodized aluminum and can be used at any length between 6` and 12` due to the locking cam
306PoolLife Safety Equipment`s `Life Jacket ( Adult ) : Adult Safety Life Jacket Vest Weight Capacity Up to 75Kg BuoyancyPolyester water resistant material. Long lasting nature`
307PoolLife Safety Equipment`s `Trolly With Oxygen Cylinder Portable : Specifications: Made out of full stainless steel. Holds B Type cylinders. Mounted on 4” wheels. Mobile on 2 units 75 mm castors. Finishing: Epoxy powder coated. `
308PoolLife Safety Equipment`s Artifical Respirator : Specifications. The resuscitator ... Silicone rubber: inner bag, outer bag, valve disc, supporting strap, mask rim (cuff). ... for instructions). Manufacturer: Ambu®.
309PoolLife Safety Equipment`s Blanket
310PoolLife Safety Equipment`s Life Rescue rope8mm ( 25m. ) : Floating Lifesaving Rope 8mm Above Water Emergency Survival Rescue Rope Line Diving Snorkeling Camping Swimming Accessory
311PoolLife Safety Equipment`s `Stretcher : Folding(2 Fold)Stretcher with Grip and carry case included Washable, water proof and anti-fungus fabric top with safety belts Supplied with carry bag`
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail